<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" media="screen" href="/~d/styles/atom10full.xsl"?><?xml-stylesheet type="text/css" media="screen" href="http://feeds.feedburner.com/~d/styles/itemcontent.css"?><feed xmlns="http://www.w3.org/2005/Atom" xmlns:openSearch="http://a9.com/-/spec/opensearch/1.1/" xmlns:georss="http://www.georss.org/georss" xmlns:gd="http://schemas.google.com/g/2005" xmlns:feedburner="http://rssnamespace.org/feedburner/ext/1.0" gd:etag="W/&quot;D0UGSHw_eip7ImA9WxBQFE0.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317</id><updated>2010-01-13T12:53:49.242-05:00</updated><title type="text">Kinesis Inc. for Chromatography Consumables, HPLC Replacement Lamps, Vaplock, Omnifit, SGE and more!</title><subtitle type="html">Kinesis laboratory hplc equipment and spares, we specialize in deuterium detector lamps, spe products, hplc / gc, hplc instruments and vials. "keywords" = "kinesis, kinesis hplc, kinesis deuterium lamps, hplc_consumables, hplc_spares, spe products, 96 Well Plates, Filtration products, GC Accessories, GC Columns, GC Instrument Spares, HPLC Columns and Guards, HPLC Instrument Spares, LC Fittings and Accessories, Rheodyne, SGE Syringes, Solid Phase Extraction, Tablet Dissolution, Valco, vials Chromatography_Vials, sample_Vials, kinesis, Nanobaume, capillary column packing"</subtitle><link rel="http://schemas.google.com/g/2005#feed" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/posts/default" /><link rel="alternate" type="text/html" href="http://www.kinesishplc.com/" /><link rel="next" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default?start-index=26&amp;max-results=25&amp;redirect=false&amp;v=2" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email></author><generator version="7.00" uri="http://www.blogger.com">Blogger</generator><openSearch:totalResults>34</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><feedburner:info uri="chromatographyproductsfromkinesisinc" /><atom10:link xmlns:atom10="http://www.w3.org/2005/Atom" rel="hub" href="http://pubsubhubbub.appspot.com/" /><link rel="license" type="text/html" href="http://creativecommons.org/licenses/by-nc-nd/2.0/" /><logo>http://lh3.google.com/kinesis.chromatography/R_TluoqEDfI/AAAAAAAAADg/8kHlIKjLZmY/s144/Detector%20Lamps.JPG.jpg</logo><atom10:link xmlns:atom10="http://www.w3.org/2005/Atom" rel="self" type="application/atom+xml" href="www.kinesishplc.com" /><feedburner:emailServiceId>ChromatographyProductsFromKinesisInc</feedburner:emailServiceId><feedburner:feedburnerHostname>http://feedburner.google.com</feedburner:feedburnerHostname><feedburner:feedFlare href="http://add.my.yahoo.com/rss?url=www.kinesishplc.com" src="http://us.i1.yimg.com/us.yimg.com/i/us/my/addtomyyahoo4.gif">Subscribe with My Yahoo!</feedburner:feedFlare><feedburner:feedFlare href="http://fusion.google.com/add?feedurl=www.kinesishplc.com" src="http://buttons.googlesyndication.com/fusion/add.gif">Subscribe with Google</feedburner:feedFlare><feedburner:browserFriendly>Thank you for visiting the Kinesis Inc. News Feed. Vist our blog at www.kinesishplc.com.</feedburner:browserFriendly><entry gd:etag="W/&quot;CUEHRHo9fCp7ImA9WxVVEEw.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-533813473906290587</id><published>2009-03-02T11:48:00.006-05:00</published><updated>2009-03-02T12:07:15.464-05:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2009-03-02T12:07:15.464-05:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="Organic Vapor Filter" /><category scheme="http://www.blogger.com/atom/ns#" term="Stacking Units" /><category scheme="http://www.blogger.com/atom/ns#" term="promotion" /><category scheme="http://www.blogger.com/atom/ns#" term="Manifold Stack Unit" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent bottle" /><category scheme="http://www.blogger.com/atom/ns#" term="Stacking Manifolds" /><category scheme="http://www.blogger.com/atom/ns#" term="Solvent Waste Manifold" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>Closed System HPLC Solvent Containment for Nearly any Waste Container</title><content type="html">&lt;a href="http://4.bp.blogspot.com/_WC228aX0cWw/SawOJas8cpI/AAAAAAAAAQ4/zhArgz9gs64/s1600-h/VAPLOCK.JPG"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5308633615712416402" style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 317px; CURSOR: hand; HEIGHT: 400px; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SawOJas8cpI/AAAAAAAAAQ4/zhArgz9gs64/s400/VAPLOCK.JPG" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; There is far greater awareness in laboratories about the safety and security of closed solvent-using systems like HPLC stations. More and more chemists, lab managers, and EH&amp;amp;S are now aware that HPLC systems and other stations can be closed even when adding waste to the container.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;With Vaplock products, closing the waste side of the HPLC station is even more affordable with a wide range of secure manifolds for nearly any waste container including Justrite Centura, carboys, DOT containers, glass bottles, drums, and many, many more. Safety should be the prime consideration for choosing your waste container, but there is no need to go to the added expense of changing over your whole lab in order to close the system, secure waste lines, prevent leaks and spills, and scrub the organic vapor.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;span style="font-size:130%;"&gt;Vaplock manifolds are available for Methanol/ACN systems, mixed reverse phase and dilute normal phase solvents, and complete normal phase HPLC stations with materials selected to withstand the solvents employed.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;We always recommend a complimentary site evaluation prior to ordering.  This ensures that you are getting the most effective, complete, and lowest cost range of Vaplock parts to accomplish your safety  and other EH&amp;amp;S goals.  Following a site evaluation by a skilled technician and installer, customers will receive a detailed quotation and, if requested, a written proposal and installation guide.  For customers that do not have time or personnel to install Vaplock manifolds, Kinesis Inc. offers this as a service.  Ask about promotions related to products installed by Kinesis Inc. for additional savings.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;For more information and technical assistance, call us directly or send an e-mail.  More information is also available on our company website.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235 E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-533813473906290587?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?a=I2nt_POx4Yc:nNTlck8tw3E:yIl2AUoC8zA"&gt;&lt;img src="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?d=yIl2AUoC8zA" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?a=I2nt_POx4Yc:nNTlck8tw3E:63t7Ie-LG7Y"&gt;&lt;img src="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?d=63t7Ie-LG7Y" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/I2nt_POx4Yc" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock&amp;level1=Manifolds" title="Closed System HPLC Solvent Containment for Nearly any Waste Container" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/533813473906290587/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=533813473906290587" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/533813473906290587?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/533813473906290587?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/I2nt_POx4Yc/closed-system-hplc-solvent-containment.html" title="Closed System HPLC Solvent Containment for Nearly any Waste Container" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://4.bp.blogspot.com/_WC228aX0cWw/SawOJas8cpI/AAAAAAAAAQ4/zhArgz9gs64/s72-c/VAPLOCK.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2009/03/closed-system-hplc-solvent-containment.html</feedburner:origLink></entry><entry gd:etag="W/&quot;AkcGR3g8fSp7ImA9WxVWFko.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-2427719413793539220</id><published>2009-02-26T14:30:00.008-05:00</published><updated>2009-02-26T14:53:46.675-05:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2009-02-26T14:53:46.675-05:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="vial" /><category scheme="http://www.blogger.com/atom/ns#" term="extractable" /><category scheme="http://www.blogger.com/atom/ns#" term="high recovery vial" /><category scheme="http://www.blogger.com/atom/ns#" term="vial cap" /><category scheme="http://www.blogger.com/atom/ns#" term="LC-MS" /><category scheme="http://www.blogger.com/atom/ns#" term="Mass Spec" /><category scheme="http://www.blogger.com/atom/ns#" term="autosampler vial" /><category scheme="http://www.blogger.com/atom/ns#" term="picogram" /><title>LC-MS Vial &amp; Cap Kits from Kinesis Inc.</title><content type="html">&lt;div&gt;&lt;a href="http://2.bp.blogspot.com/_WC228aX0cWw/SabuV7NKWtI/AAAAAAAAAQo/7gzUrZsDJk8/s1600-h/Vials+with+pico+cap.jpg"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5307191271340268242" style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 400px; CURSOR: hand; HEIGHT: 268px; TEXT-ALIGN: center" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/SabuV7NKWtI/AAAAAAAAAQo/7gzUrZsDJk8/s400/Vials+with+pico+cap.jpg" border="0" /&gt;&lt;/span&gt;&lt;/a&gt; &lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;New from Kinesis Inc. are a range of vial and cap kits developed specifically for the LC-MS Market. These kits feature a range fo vials from standard 1.5mL autosampler vials, high recovery vials, microvolumne inserts, polypropylene vials and other combinations with an extremely pure, high-grade, low-extractable cap.&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;As the following comparison illustrates the difference between our new LC-MS Caps and standard PTFE/Silicone Caps:&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5307194260750134914" style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 400px; CURSOR: hand; HEIGHT: 110px; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SabxD7oA7oI/AAAAAAAAAQw/j1tb_t7Ksx4/s400/pico.JPG" border="0" /&gt;This comparison of MS data was done by filling each vial with methanol and inverting for one hour. The vials were then pierced three times with a direct injection electro spray quad mass spec. Extractables were below the picogram range.&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Our LC-MS vials seal just as well as a standard PTFE/Silicone septa and puncture with far less force.&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;These come kit-packed in 100/pack. Choose clear, amber, PP (300uL or 700uL), high recovery, or microvolume insert as options. Call us or e-mail for pricing and more information.&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt; &lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235 E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; &lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-2427719413793539220?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?a=-yW2P27Wcgw:cNcZ66M4qFY:yIl2AUoC8zA"&gt;&lt;img src="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?d=yIl2AUoC8zA" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?a=-yW2P27Wcgw:cNcZ66M4qFY:63t7Ie-LG7Y"&gt;&lt;img src="http://feeds.feedburner.com/~ff/ChromatographyProductsFromKinesisInc?d=63t7Ie-LG7Y" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/-yW2P27Wcgw" height="1" width="1"/&gt;</content><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/2427719413793539220/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=2427719413793539220" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2427719413793539220?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2427719413793539220?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/-yW2P27Wcgw/lc-ms-vial-cap-kits-from-kinesis-inc.html" title="LC-MS Vial &amp; Cap Kits from Kinesis Inc." /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://2.bp.blogspot.com/_WC228aX0cWw/SabuV7NKWtI/AAAAAAAAAQo/7gzUrZsDJk8/s72-c/Vials+with+pico+cap.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2009/02/lc-ms-vial-cap-kits-from-kinesis-inc.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C08CQXc4eip7ImA9WxVWFUw.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-5987207421277498430</id><published>2009-02-24T16:26:00.008-05:00</published><updated>2009-02-24T16:44:20.932-05:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2009-02-24T16:44:20.932-05:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="bottle cap" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent delivery" /><category scheme="http://www.blogger.com/atom/ns#" term="c series" /><title>Clouseout on Omnifit C-Series Solvent Bottle Caps for HPLC</title><content type="html">&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SaRozv4MvxI/AAAAAAAAAQg/l9Y0iHLmnfI/s1600-h/00938C-4V.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5306481499184086802" style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 267px; CURSOR: hand; HEIGHT: 400px; TEXT-ALIGN: center" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SaRozv4MvxI/AAAAAAAAAQg/l9Y0iHLmnfI/s400/00938C-4V.jpg" border="0" /&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Omnifit has discontinued their C-Series Bottle Cap this year. These were great bottle caps loaded with solid features including:&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Omnifit's versatile Cap Connector which allows many connections depending on pressure requirements. O-rings, PTFE cones, or connections to a 1/4-28F flat-bottom port accommodate low to high pressures.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Independent Valving on each connection.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Free-spinning cap collar means no tubing twist when you remove the cap from the bottle&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Inert fluid paths with PTFE and PCTFE materials.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Extra Adaptors allow connection to 0.5mm up to 4mm tubing with ease&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Optional barbed adaptors for soft-wall tubing&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Inlet check-valves and filters are also available&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;While remaining supplies last, we're offering Omnifit C-Series caps at 30% off list prices. Choose from three models to fit 38-340 bottles commonly used for HPLC reagents.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;00938C-2V - 38-340 solvent bottle cap, 2-port, with valves&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;00938-3V - 38-340 solvent bottle cap, 3-port, with valves&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;00938-4V - 38-340 solvent bottle cap, 4-port, with valves&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235 E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="color:#33ff33;"&gt; &lt;/span&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-5987207421277498430?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=kqY9CuJ0"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=4wCxHWDj"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/VeTZ4mJ2H6Y" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit" title="Clouseout on Omnifit C-Series Solvent Bottle Caps for HPLC" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/5987207421277498430/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=5987207421277498430" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5987207421277498430?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5987207421277498430?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/VeTZ4mJ2H6Y/clouseout-on-omnifit-c-series-solvent.html" title="Clouseout on Omnifit C-Series Solvent Bottle Caps for HPLC" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://1.bp.blogspot.com/_WC228aX0cWw/SaRozv4MvxI/AAAAAAAAAQg/l9Y0iHLmnfI/s72-c/00938C-4V.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2009/02/clouseout-on-omnifit-c-series-solvent.html</feedburner:origLink></entry><entry gd:etag="W/&quot;DUcFRnw8cSp7ImA9WxVWFU0.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-2800015628547235223</id><published>2009-02-24T14:24:00.003-05:00</published><updated>2009-02-24T15:23:37.279-05:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2009-02-24T15:23:37.279-05:00</app:edited><title>Ultimate Microsampling Device from Kinesis Inc.</title><content type="html">&lt;strong&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Precision 300 &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_0"&gt;uL&lt;/span&gt; glass conical insert and 12x32 mm vial are one precise integral unit. &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Compatible with the majority of &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_1"&gt;autosamplers&lt;/span&gt;. &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Available in short thread screw cap, crimp top and snap cap.&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="http://3.bp.blogspot.com/_WC228aX0cWw/SaRNITZXIVI/AAAAAAAAAQQ/18fwaH_AXmM/s1600-h/Q-Sert.JPG"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5306451065990226258" style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 400px; CURSOR: hand; HEIGHT: 364px; TEXT-ALIGN: center" alt="" src="http://3.bp.blogspot.com/_WC228aX0cWw/SaRNITZXIVI/AAAAAAAAAQQ/18fwaH_AXmM/s400/Q-Sert.JPG" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;br /&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Evaporation and cross contamination between insert and vial is eliminated with a virtual seal of insert to septa.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Higher sample recovery with either bottom loading or side loading needles. Residual dead volume can be as low as 2 &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_2"&gt;uL&lt;/span&gt;, depending on precision adjustment of instrument.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Consistent sample recovery from vial to vial because the insert is always at same precise depth within the vial.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Compatible with all &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_3"&gt;autosamplers&lt;/span&gt; that utilize 12x32mm vials&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Vials are made in the USA from Class A &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_4"&gt;Borosilicate&lt;/span&gt; Glass.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Easy sample identification on white mat finish marking panel using pen, pencil or any other type of marking device.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Wide mouth opening of vial has larger target area reducing possibility of bent needles.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Clear and Amber vials available.&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;Call us or e-mail for more product information!&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235 E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt; &lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-2800015628547235223?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=w1FUWZwt"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=5GoUaMPZ"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/Z4GM-WbW1yA" height="1" width="1"/&gt;</content><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/2800015628547235223/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=2800015628547235223" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2800015628547235223?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2800015628547235223?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/Z4GM-WbW1yA/ultimate-microsampling-device-from.html" title="Ultimate Microsampling Device from Kinesis Inc." /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://3.bp.blogspot.com/_WC228aX0cWw/SaRNITZXIVI/AAAAAAAAAQQ/18fwaH_AXmM/s72-c/Q-Sert.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2009/02/ultimate-microsampling-device-from.html</feedburner:origLink></entry><entry gd:etag="W/&quot;Dk8DQHYzeCp7ImA9WxVSF0U.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-6226308335876772171</id><published>2009-01-12T12:57:00.007-05:00</published><updated>2009-01-12T13:27:51.880-05:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2009-01-12T13:27:51.880-05:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="hplc detector lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="D2 lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="deuterium lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="HPLC lamp" /><title>New Larger Product Line of Deuterium Lamps for HPLC Detectors</title><content type="html">&lt;a href="http://4.bp.blogspot.com/_WC228aX0cWw/SWuIfWTZLDI/AAAAAAAAAPU/i7qcfON6Y7g/s1600-h/LDAGI105a.JPG"&gt;&lt;img id="BLOGGER_PHOTO_ID_5290472259421023282" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; WIDTH: 234px; CURSOR: hand; HEIGHT: 320px" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SWuIfWTZLDI/AAAAAAAAAPU/i7qcfON6Y7g/s320/LDAGI105a.JPG" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Kinesis Inc. announce a wider range of replacement lamps for HPLC detectors and UV/Vis spectrophotometers. This includes the largest number of high-quality long-life replacement lamps ever available!&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;a href="http://www.kinesis-usa.com/displaycategory.asp"&gt;Click here to see the full range of instrument models supported by Kinesis Replacement Deuterium Lamps!&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Several points differentiate Kinesis lamps from others:&lt;/span&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Each lamp type is application-matched for each instrument ensuring OEM specifications and lifetime are met or exceeded&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;High-quality long life lamps from the world's leading manufacturers&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;1000 hour warranty and 2000 hour warranty lamps available&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Kinesis manufactures/pre-aligns Deuterium lamps for end-users, independent instrument service companies and distributors. In recognizing the importance of using lamps supplied by the OEM’s, Kinesis has formed strong partnerships with manufacturers who produce the majority of the lamps fitted in today’s leading detectors, including the Agilent 1100 and Waters 2487 models. Bare lamps supplied directly to Kinesis are precision aligned and tested at our facility in accordance with our stringent ISO 9000 certified procedures.&lt;/span&gt;&lt;/p&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;All Kinesis lamps are certified recording the date of manufacture, serial number, tester’s name and the intensity counts reading for future traceability. Only lamps made to the strictest tolerances receive the Kinesis Guaranteed Lamp Seal. This means that Kinesis provides lamps without any compromise on quality compared with OEM specifications. We offer a comprehensive range including the Shimadzu SPD10A, Waters 2487 and both Agilent 1100 DAD and VWD. A range of lamps are kept in stock in the factory and our sales offices, close to our customers ensuring that when replacements are needed there is no delay.&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;To assist our customers with pre-sale information and after-sales support Kinesis technical team of experts now include detector lamp R&amp;amp;D and Applications Engineering specialist. Kinesis are able to offer a new, higher level of technical support to our customers which was previously only available to the instrument OEMs.&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Premium quality lamps, available from stock with the highest level of technical support before and after the sale. Contact us today!&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;http://www.kinesis-usa.com/&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;Toll Free 866.934.6353&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;sales@kinesis-usa.com&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-6226308335876772171?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=5Jmf6PFv"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=s78jCf68"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/BLnNNcJtPPU" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/" title="New Larger Product Line of Deuterium Lamps for HPLC Detectors" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/6226308335876772171/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=6226308335876772171" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6226308335876772171?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6226308335876772171?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/BLnNNcJtPPU/new-larger-product-line-of-deuterium.html" title="New Larger Product Line of Deuterium Lamps for HPLC Detectors" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://4.bp.blogspot.com/_WC228aX0cWw/SWuIfWTZLDI/AAAAAAAAAPU/i7qcfON6Y7g/s72-c/LDAGI105a.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2009/01/new-larger-product-line-of-deuterium.html</feedburner:origLink></entry><entry gd:etag="W/&quot;DkEAQ3w4eCp7ImA9WxRXFkU.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-8910109983658817000</id><published>2008-10-22T09:09:00.009-04:00</published><updated>2008-10-22T10:10:42.230-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-22T10:10:42.230-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE" /><category scheme="http://www.blogger.com/atom/ns#" term="promotion" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="omnifit" /><category scheme="http://www.blogger.com/atom/ns#" term="PEEK tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent delivery" /><title>View the new Omnifit Fittings Brochure Online as a Kinesis Flipbook</title><content type="html">&lt;a href="http://4.bp.blogspot.com/_WC228aX0cWw/SP8owbm9MeI/AAAAAAAAAPE/7LSXhWtCIIM/s1600-h/Omnifit+Brochure.JPG"&gt;&lt;img id="BLOGGER_PHOTO_ID_5259967702302011874" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SP8owbm9MeI/AAAAAAAAAPE/7LSXhWtCIIM/s320/Omnifit+Brochure.JPG" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Kinesis Inc. have published the new Fittings Systems brochure as a convenient to read flip book. &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/books/omnifit/omnifit_fittings/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Click here to view it online now!&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;The new brochure details specifications for fittings that can be used on 1/16" OD, 1/8" OD, and 3/16" OD tubing for connections ranging from 30 psi up to 1000 psi.&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;New highlights include:&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;An easy to read Selection Guide for choosing the correct fittings based on tubing size and pressure requirements&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;New Click-N-Seal fitting nuts that let you feel and hear when you reach the correct tightness of the fitting nut.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;New 3/16" OD tubing fittings.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Assembled custom tubing sets&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;img id="BLOGGER_PHOTO_ID_5259978374736607666" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SP8ydphpebI/AAAAAAAAAPM/lacQInDotm0/s320/tubing+sets.JPG" border="0" /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;In addition to providing assembly service using Omnifit products, Kinesis Inc. also offer installation of complex tubing assemblies on your in-house systems. Call or e-mail for details.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;a href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit&amp;amp;level1=FittingsandTubing"&gt;Click here to view the entire range of Omnifit Fittings, adaptors and other parts.  Buy online!&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="color:#33ff33;"&gt; &lt;/span&gt;&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-8910109983658817000?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=Ds9D4jMm"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=OwMHM1C9"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/6TOyoiM6reU" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/books/omnifit/omnifit%5Ffittings/" title="View the new Omnifit Fittings Brochure Online as a Kinesis Flipbook" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/8910109983658817000/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=8910109983658817000" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8910109983658817000?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8910109983658817000?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/6TOyoiM6reU/view-new-omnifit-fittings-brochure.html" title="View the new Omnifit Fittings Brochure Online as a Kinesis Flipbook" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://4.bp.blogspot.com/_WC228aX0cWw/SP8owbm9MeI/AAAAAAAAAPE/7LSXhWtCIIM/s72-c/Omnifit+Brochure.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/10/view-new-omnifit-fittings-brochure.html</feedburner:origLink></entry><entry gd:etag="W/&quot;CUcGSH4-cCp7ImA9WxRXFUw.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-2386264890926402981</id><published>2008-10-20T10:03:00.008-04:00</published><updated>2008-10-20T10:30:29.058-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-20T10:30:29.058-04:00</app:edited><title>NEW! - SPE Method Development Recommendations for Melamine from Milk</title><content type="html">&lt;a href="http://2.bp.blogspot.com/_WC228aX0cWw/SPyRwt_BoGI/AAAAAAAAAO8/HgwdtpoqaEQ/s1600-h/IST+logo.JPG"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5259238731025588322" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/SPyRwt_BoGI/AAAAAAAAAO8/HgwdtpoqaEQ/s320/IST+logo.JPG" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Biotage have released recommendations for method development for melamine from milk under document IST0413C using their Confirm HCX cartridge. Call Kinesis Inc. at (866) 934-6353 or e-mail &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; to get a copy of this method. &lt;/span&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Isolute Confirm HCX 100mg/3mL cartridges and other sizes are available from Kinesis Inc. &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=ISOLUTE&amp;amp;level1=Cartridge&amp;amp;level2=HCX"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Click here for pricing!&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; &lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-2386264890926402981?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=Aid9Sa4e"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=X7nmnelv"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/pTupDG-TueM" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/bitem2.asp?category=ISOLUTE&amp;level1=Cartridge&amp;level2=HCX" title="NEW! - SPE Method Development Recommendations for Melamine from Milk" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/2386264890926402981/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=2386264890926402981" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2386264890926402981?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2386264890926402981?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/pTupDG-TueM/new-spe-method-development.html" title="NEW! - SPE Method Development Recommendations for Melamine from Milk" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://2.bp.blogspot.com/_WC228aX0cWw/SPyRwt_BoGI/AAAAAAAAAO8/HgwdtpoqaEQ/s72-c/IST+logo.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/10/new-spe-method-development.html</feedburner:origLink></entry><entry gd:etag="W/&quot;DUcER38ycCp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-6233951968567298162</id><published>2008-10-06T13:57:00.007-04:00</published><updated>2008-10-06T14:16:46.198-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T14:16:46.198-04:00</app:edited><title>New Redesigned T-Series Bottle Cap from Omnifit</title><content type="html">&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SOpUodyjYbI/AAAAAAAAALw/sVvzIoF2fOU/s1600-h/00945T-4V.jpg"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5254104969449267634" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SOpUodyjYbI/AAAAAAAAALw/sVvzIoF2fOU/s400/00945T-4V.jpg" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Economical Omnifit T-Series Bottle caps are designed with 1/8" Luer Ports. This is a convenient method of making temporary connections, like for a syringe, or inserting 1/8" OD for HPLC supply lines.&lt;br /&gt;&lt;br /&gt;By re-designing certain features of solvent bottle caps for easier manufacturing, Omnifit reduced the list price by around 50%, making the caps more cost-effective for our laboratory end-users. Omnifit caps are now not only technically the best on the market, but they are economical too!&lt;br /&gt;&lt;br /&gt;Key to the redesign, it is now much easier to push through the 1/8" OD tubing through the Luer ports compared with the old version. It is no longer necessary to cut the tubing to a point and to pull through using pliers or a similar tool. The tubing can now be pushed through easily by hand, even with a blunt end. However, the fit is still tight enough to ensure a leak tight and vapor-proof seal.&lt;br /&gt;&lt;br /&gt;Until the end of October, get a free bottle adaptor kit with every T-Series Cap purchased. The bottle adaptor kit includes a luer plugs, a 1/16" OD tube adaptor, and a barbed tube adaptor. &lt;/span&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=Omnifit&amp;amp;level1=BottlesandCaps&amp;amp;level2=Caps"&gt;Click here&lt;/a&gt; to buy online at Kinesis Inc. or e-mail &lt;a href="mailto:sales@kinesis-usa.com"&gt;sales@kinesis-usa.com&lt;/a&gt; for more information and technical assistance.&lt;/p&gt;&lt;/span&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; &lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;br /&gt;&lt;/p&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-6233951968567298162?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=LTc23ARG"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=kjopuMrl"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/y0ej_fTvg9o" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit" title="New Redesigned T-Series Bottle Cap from Omnifit" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/6233951968567298162/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=6233951968567298162" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6233951968567298162?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6233951968567298162?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/y0ej_fTvg9o/new-redesigned-t-series-bottle-cap-from.html" title="New Redesigned T-Series Bottle Cap from Omnifit" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://1.bp.blogspot.com/_WC228aX0cWw/SOpUodyjYbI/AAAAAAAAALw/sVvzIoF2fOU/s72-c/00945T-4V.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/10/new-redesigned-t-series-bottle-cap-from.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0QESX87fCp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-7120562770692067911</id><published>2008-10-03T09:15:00.011-04:00</published><updated>2008-10-06T12:41:48.104-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:41:48.104-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="omnifit" /><category scheme="http://www.blogger.com/atom/ns#" term="PEEK tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="fitting nut" /><category scheme="http://www.blogger.com/atom/ns#" term="ferrule" /><title>Omnifit Tubing Connections Up to 1000 psi  - Lower Cost, Higher Performance</title><content type="html">&lt;p&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;a href="http://2.bp.blogspot.com/_WC228aX0cWw/SOYfaa78svI/AAAAAAAAALo/GgajevdQPEI/s1600-h/new+fitting+old+gripper+section+closeup.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5252920554142085874" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/SOYfaa78svI/AAAAAAAAALo/GgajevdQPEI/s400/new+fitting+old+gripper+section+closeup.jpg" border="0" /&gt;&lt;/a&gt; &lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Chemically inert flangeless fitting with permanently attached PTFE ferrule&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Ideal for repeat connect/disconnect Pressure rated up to 1000psi (69 bar)&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;span style="font-size:130%;"&gt;For 1⁄16”, 1⁄8” or 3⁄16” OD semi-rigid tubing e.g. PTFE, ETFE, FEP&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;For flat-bottom . 1/4”-28 UNF, M6 or 5⁄16”-24 UNF ports'&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;Glass-filled fitting nuts "bite" into port&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;No tubing twist&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;span style="font-size:130%;"&gt;The Omni-Lok™Type P fitting system uses a one-piece ferrule which fits permanently onto the outside of semi-rigid tubing. Ferrules have an inner PTFE sealing face ensuring that only PTFE is in the fluid path.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:130%;"&gt;The fitting nut can spin freely, eliminating tubing twist. A recess in the fitting houses the ferrule, allowing maximum thread engagement with the port. This ensures the system stays sealed up to 1000psi (69 bar) pressure, even in shallow PTFE ports. Note: Omni-Lok™Type P for 3⁄16” OD tubing and 5⁄16”-24 UNF flat-bottom ports is pressure rated up to 200 psi (14 bar).&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;Compact head fitting nuts, in glass-filled polypropylene, are available in a range of different colors for easy line identification. Other options are a longer length nut for applications where accessibility is an issue (1⁄8” OD tubing only) and standard head nuts in PEEK™for higher temperatures.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;Buy Online at Kinesis Inc. &lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=Omnifit&amp;amp;level1=FittingsandTubing&amp;amp;level2=Omni-Lok"&gt;Click Here!&lt;/a&gt; Call Toll Free in the USA (866) 934-6353 for more information or technical assistance.&lt;/span&gt;&lt;/span&gt; &lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;br /&gt;&lt;/p&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-7120562770692067911?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=6bCmlPEu"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=hXh2fSNL"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/RmGl8FZtsDs" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit" title="Omnifit Tubing Connections Up to 1000 psi  - Lower Cost, Higher Performance" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/7120562770692067911/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=7120562770692067911" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/7120562770692067911?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/7120562770692067911?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/RmGl8FZtsDs/omnifit-tubing-connections-up-to-1000.html" title="Omnifit Tubing Connections Up to 1000 psi  - Lower Cost, Higher Performance" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://2.bp.blogspot.com/_WC228aX0cWw/SOYfaa78svI/AAAAAAAAALo/GgajevdQPEI/s72-c/new+fitting+old+gripper+section+closeup.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/10/omnifit-tubing-connections-up-to-1000.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0QNRns_eyp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-7321476839922764046</id><published>2008-09-30T09:37:00.007-04:00</published><updated>2008-10-06T12:43:17.543-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:43:17.543-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="column bleed valve" /><category scheme="http://www.blogger.com/atom/ns#" term="low pressure liquid chromatography" /><category scheme="http://www.blogger.com/atom/ns#" term="promotion" /><category scheme="http://www.blogger.com/atom/ns#" term="Omnifit Column Assembly" /><category scheme="http://www.blogger.com/atom/ns#" term="medium pressure liquid chromatography" /><category scheme="http://www.blogger.com/atom/ns#" term="omnifit" /><category scheme="http://www.blogger.com/atom/ns#" term="LC column" /><title>PROMOTION:  25% off Omnifit Column Bleed Valve 001131 with Purchase of any Omnifit Column</title><content type="html">&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SOIvNQBrCrI/AAAAAAAAALQ/jq1hFdOi8II/s1600-h/1131+iso.jpg"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5251812020154206898" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SOIvNQBrCrI/AAAAAAAAALQ/jq1hFdOi8II/s320/1131+iso.jpg" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; Until the end of the year, take 25% off the cost of Omnifit P/N 001131 Column Bleed Valve with the purchase of any Omnifit Chromatography Column Assembly. &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;All Omnifit Columns and Accessories can be viewed on the Kinesis Inc. website. &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit&amp;amp;level1=Columns"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Click here.&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;There are a number of convenient benefits offered by equipping your column assembly with a bleed valve. Installed at the top of the column, it is easy to change solvents during a run. Installed that the bottom of the column, the bleed valve allows users to divert unwanted fractions or interferences to waste.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;span style="font-size:130%;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;The bleed valve easily installs at the Omnifit Cap Connector on either end of the column with the 1/4-28 male thread and offers two Omnifit Cap Connectors for connecting fluid lines.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;No limit on the number of P/N 001131 offered at the discount price. Minimum purchase to receive the discount is one complete Omnifit Column Assembly, any size. Offer expires 12/31/2008 and may not be combined with any other offers or discounts.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Call us Toll Free in the USA at (866) 934-6353 or e-mail &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; for more information or technical assistance.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-7321476839922764046?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=RAfLGh1D"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=EF6LUDjy"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/KftZ_pHVLCw" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit&amp;level1=Columns" title="PROMOTION:  25% off Omnifit Column Bleed Valve 001131 with Purchase of any Omnifit Column" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/7321476839922764046/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=7321476839922764046" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/7321476839922764046?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/7321476839922764046?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/KftZ_pHVLCw/promotion-25-off-omnifit-column-bleed.html" title="PROMOTION:  25% off Omnifit Column Bleed Valve 001131 with Purchase of any Omnifit Column" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://1.bp.blogspot.com/_WC228aX0cWw/SOIvNQBrCrI/AAAAAAAAALQ/jq1hFdOi8II/s72-c/1131+iso.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/09/promotion-25-off-omnifit-column-bleed.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0MGQXkycCp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-8342150482930181730</id><published>2008-09-05T14:24:00.006-04:00</published><updated>2008-10-06T12:43:40.798-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:43:40.798-04:00</app:edited><title>New Click-N-Seal Fittings from Omnifit</title><content type="html">&lt;a href="http://3.bp.blogspot.com/_WC228aX0cWw/SMF6kmr1SOI/AAAAAAAAALI/7JL5f5YM0VY/s1600-h/untitled.JPG"&gt;&lt;img id="BLOGGER_PHOTO_ID_5242606210514241762" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://3.bp.blogspot.com/_WC228aX0cWw/SMF6kmr1SOI/AAAAAAAAALI/7JL5f5YM0VY/s320/untitled.JPG" border="0" /&gt;&lt;/a&gt; &lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;CLICK-N-SEAL™ &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Hand-tight fittings without the guesswork&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;For Omni-Lok™ Type P &amp;amp; Type S ferrules or inverted cones for maximum pressures up to 1,000 psi&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;For 1⁄16” or 1⁄8” OD semi-rigid tubing&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Feel and hear when the fitting is properly installed&lt;br /&gt;&lt;/span&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Click-N-Seal™ offers a unique system for hand-tight fittings. As the fitting is tightened, the resistance of the cap increases until the correct torque is reached; at which point, the cap clicks. The user is able to hand-tighten the fittings without tools or guesswork and be confident that the fitting is properly seated, creating a secure seal. The fitting can be unscrewed and reused.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-size:130%;"&gt;Call Kinesis Inc at 866.934-6353 or &lt;a href="mailto:sales@kinesis-usa.com"&gt;e-mail &lt;/a&gt;us for pricing and more technical information.&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-8342150482930181730?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=EaN3mxyD"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=mlB90QTY"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/p34y9FWVWo8" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit" title="New Click-N-Seal Fittings from Omnifit" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/8342150482930181730/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=8342150482930181730" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8342150482930181730?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8342150482930181730?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/p34y9FWVWo8/new-click-n-seal-fittings-from-omnifit.html" title="New Click-N-Seal Fittings from Omnifit" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://3.bp.blogspot.com/_WC228aX0cWw/SMF6kmr1SOI/AAAAAAAAALI/7JL5f5YM0VY/s72-c/untitled.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/09/new-click-n-seal-fittings-from-omnifit.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0MBQX0_fyp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-6455786729092747652</id><published>2008-08-25T16:05:00.005-04:00</published><updated>2008-10-06T12:44:10.347-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:44:10.347-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="Organic Vapor Filter" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="EF-100" /><category scheme="http://www.blogger.com/atom/ns#" term="bottle cap" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent bottle" /><category scheme="http://www.blogger.com/atom/ns#" term="Solvent Waste Manifold" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>SV-171 WASTE KIT FOR GL45 LAB BOTTLES</title><content type="html">&lt;ul&gt;&lt;li&gt;&lt;a href="http://2.bp.blogspot.com/_WC228aX0cWw/SLMRpZXjy_I/AAAAAAAAAKo/eDqpSZPezXs/s1600-h/SV-171.JPG"&gt;&lt;img id="BLOGGER_PHOTO_ID_5238550194444028914" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/SLMRpZXjy_I/AAAAAAAAAKo/eDqpSZPezXs/s400/SV-171.JPG" border="0" /&gt;&lt;/a&gt; &lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Capture solvent waste lines securely, from multiple effluent streams &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Activated carbon filter minimizes odor escape &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Ideal for HPLC use&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Use the SV-171 solvent waste kit to collect fluid wastes generated by HPLC or other solvent-using systems. An activated carbon filter minimizes odor escape from the collection vessel. The kit includes components to attach up to three 1/16” OD waste lines, and two 1/4” ID lines. The design will accommodate GL45 threaded bottles; GL38 bottles may be used with a purchase of an adapter, BC-151. Material components are Polypropylene, with an expanded PTFE gasket to seal against the bottle surface. The ferrules enclosed for hardwall tubing are ETFE.&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Although SV-171 is intended for use with Shimadzu HPLC instruments, and should allow for connection of most waste tubing lines typical to that system, non-standard tubing sizes may still be connected by selecting a different fitting. Connections for both hardwall and softwall tubing available. Call us at 866.934.6353 or send an &lt;a href="mailto:sales@kinesis-usa.com"&gt;e-mail&lt;/a&gt;.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-6455786729092747652?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=G52sFc5z"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=TRgHpoiv"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/7GkccsfKdC8" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock" title="SV-171 WASTE KIT FOR GL45 LAB BOTTLES" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/6455786729092747652/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=6455786729092747652" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6455786729092747652?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6455786729092747652?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/7GkccsfKdC8/sv-171-waste-kitfor-gl45-lab-bottles.html" title="SV-171 WASTE KIT FOR GL45 LAB BOTTLES" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://2.bp.blogspot.com/_WC228aX0cWw/SLMRpZXjy_I/AAAAAAAAAKo/eDqpSZPezXs/s72-c/SV-171.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/08/sv-171-waste-kitfor-gl45-lab-bottles.html</feedburner:origLink></entry><entry gd:etag="W/&quot;Dk4CSXg_fSp7ImA9WxdUFk0.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-5139632965080861236</id><published>2008-08-01T11:18:00.003-04:00</published><updated>2008-08-01T11:36:08.645-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-08-01T11:36:08.645-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="Organic Vapor Filter" /><category scheme="http://www.blogger.com/atom/ns#" term="Stacking Units" /><category scheme="http://www.blogger.com/atom/ns#" term="promotion" /><category scheme="http://www.blogger.com/atom/ns#" term="Manifold Stack Unit" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="EF-100" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent bottle" /><category scheme="http://www.blogger.com/atom/ns#" term="Stacking Manifolds" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent delivery" /><category scheme="http://www.blogger.com/atom/ns#" term="Solvent Waste Manifold" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>New Vaplock Promotion from Kinesis Inc.</title><content type="html">&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Kinesis Inc. announce a new promotion for Vaplock Closed Systems for Solvent and Vapor Containment Products! Refer to Promotion Code VPL0708 and:&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Get one (1) free EF-100 Vaplock Organic Vapor Filter Cartridge with any Vaplock manifold purchased from Kinesis Inc. Value = $16.00&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Get five (5) free EF-100 Vaplock Organic Vapor Cartridges with any Vaplock manifold purchased from and installed by Kinesis Inc. Value = $80.00&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5229569345286753410" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SJMpnLIWzII/AAAAAAAAAKg/0gHzyesKklo/s400/Vaplock+Voucher+VPL0708.JPG" border="0" /&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Call us at (866) 934-6353 for details on Vaplock manifolds and quotes for installation. In most cases, the product value of five EF-100 exceeds the cost of labor for installation!&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;a href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock"&gt;Click here&lt;/a&gt; to see all the Vaplock Closed Systems products online at &lt;a href="http://www.kinesis-usa.com/"&gt;http://www.kinesis-usa.com/&lt;/a&gt;. You may also &lt;/span&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;E-mail us&lt;/a&gt; for more information on Vaplock or our other products.&lt;/p&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-5139632965080861236?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=lsF6to1q"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=1vt8lqNC"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/uE3A4c3ehaA" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock" title="New Vaplock Promotion from Kinesis Inc." /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/5139632965080861236/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=5139632965080861236" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5139632965080861236?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5139632965080861236?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/uE3A4c3ehaA/new-vaplock-promotion-from-kinesis-inc.html" title="New Vaplock Promotion from Kinesis Inc." /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://4.bp.blogspot.com/_WC228aX0cWw/SJMpnLIWzII/AAAAAAAAAKg/0gHzyesKklo/s72-c/Vaplock+Voucher+VPL0708.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/08/new-vaplock-promotion-from-kinesis-inc.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0MDQno_fyp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-7274239946827533210</id><published>2008-07-21T09:38:00.005-04:00</published><updated>2008-10-06T12:44:33.447-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:44:33.447-04:00</app:edited><title>Bleed Valve for Omnifit Columns Provides Versatility</title><content type="html">&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;The Omnifit column bleed valve provides an easy and efficient method for connecting to the chromatography column.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SISSsOB-TeI/AAAAAAAAAKY/RLZLf94CguY/s1600-h/1131+iso.jpg"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5225462756034891234" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SISSsOB-TeI/AAAAAAAAAKY/RLZLf94CguY/s400/1131+iso.jpg" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; Simply connect the male 1/4-28 fitting directly to the column and two sections of tubing to the Omnifit Cap Connectors using inverted cones, o-rings, Omnifit Grippers, or Omnifit ferrules. If installed on the leading end of the column, the valve provides an easy way to switch solvents without disconnecting the tubing. If installed on the downstream side, the valve may be used to bleed off air, or unwanted fractions.&lt;/span&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;a href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit"&gt;Click here&lt;/a&gt; to view the entire range of Omnifit components available from Kinesis Inc. You may also &lt;a href="mailto:sales@kinesis-usa.com"&gt;e-mail us&lt;/a&gt; for more information.&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-7274239946827533210?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=BQuRQcgS"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=yxnvcZ24"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/wjHB4dSQ-_E" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=Omnifit" title="Bleed Valve for Omnifit Columns Provides Versatility" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/7274239946827533210/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=7274239946827533210" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/7274239946827533210?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/7274239946827533210?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/wjHB4dSQ-_E/bleed-valve-for-omnifit-columns.html" title="Bleed Valve for Omnifit Columns Provides Versatility" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://1.bp.blogspot.com/_WC228aX0cWw/SISSsOB-TeI/AAAAAAAAAKY/RLZLf94CguY/s72-c/1131+iso.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/07/bleed-valve-for-omnifit-columns.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0MNQ389fSp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-8635302153245169128</id><published>2008-07-17T12:35:00.005-04:00</published><updated>2008-10-06T12:44:52.165-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:44:52.165-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>Download the New Vaplock Product Catalog</title><content type="html">&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;The new Vaplock Catalog is now available listing several new products. &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/files/downloads/Vaplock-Kinesis%20USA.pdf"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Click here &lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;to download from the Kinesis Inc. website (registraiton required).&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;img id="BLOGGER_PHOTO_ID_5224026575239192002" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SH94ffpVHcI/AAAAAAAAAKQ/T7KlFgdFE3M/s400/Vaplock+Catalog.JPG" border="0" /&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-8635302153245169128?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=qoMU8JjR"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=2YPXYxCM"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/3GPPOguAEq8" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock" title="Download the New Vaplock Product Catalog" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/8635302153245169128/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=8635302153245169128" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8635302153245169128?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8635302153245169128?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/3GPPOguAEq8/download-new-vaplock-product-catalog.html" title="Download the New Vaplock Product Catalog" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://4.bp.blogspot.com/_WC228aX0cWw/SH94ffpVHcI/AAAAAAAAAKQ/T7KlFgdFE3M/s72-c/Vaplock+Catalog.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/07/download-new-vaplock-product-catalog.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0IBQ30zfSp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-2982067326830953625</id><published>2008-07-01T09:54:00.010-04:00</published><updated>2008-10-06T12:45:52.385-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:45:52.385-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="Stacking Units" /><category scheme="http://www.blogger.com/atom/ns#" term="Manifold Stack Unit" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="Stacking Manifolds" /><category scheme="http://www.blogger.com/atom/ns#" term="Solvent Waste Manifold" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>How Many Waste Lines?  Use Vaplock Manifold Stack Units</title><content type="html">&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SGpG7SgTQ_I/AAAAAAAAAKI/nCvnmIh8ucY/s1600-h/STACKED-MANIFOLD_30-LINES-W.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5218061102655685618" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SGpG7SgTQ_I/AAAAAAAAAKI/nCvnmIh8ucY/s400/STACKED-MANIFOLD_30-LINES-W.jpg" border="0" /&gt;&lt;/a&gt; &lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;8 waste lines from your HPLC? 11 HPLC waste lines? 30 HPLC Waste lines? Manifold stack units can increase the number of tubing connections almost indefinitely. Select a stack unit by your material and tubing requirements.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;The primary consideration will be the combined flow rate from all the HPLC waste lines. Under normal analytical flow rates of 1 mL to 2 mL per minute from each instrument, there isn't so too much concern. However on prep systems or other higher flow rates, consideration to the connection to the waste container and the waste container volume should be considered. &lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;/div&gt;&lt;div&gt;&lt;div&gt;&lt;a href="http://2.bp.blogspot.com/_WC228aX0cWw/SGo-CwC22gI/AAAAAAAAAJQ/0xELys3yY4U/s1600-h/MA-300-on-MA-601-closeup-we.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5218051335239686658" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/SGo-CwC22gI/AAAAAAAAAJQ/0xELys3yY4U/s400/MA-300-on-MA-601-closeup-we.jpg" border="0" /&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;A 2 gallon or 5 gallon container is sufficient for most analytical systems and quick-connect manifolds like Vaplock MA-601 may be used with a MA-300 or MA-600 Stacking unit. &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;For high flow rates, a larger waste container may be chosen with cam-lock connections. Use Vaplock PM-601 with MA-300 or MA-600 stacking units, for example.&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;There are hundreds of possibilities to combine fluid lines from your HPLC. Pictured are only a few of the options. &lt;a href="mailto:sales@kinesis-usa.com"&gt;E-mail us &lt;/a&gt;or call to discuss your specific needs. &lt;a href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock&amp;amp;level1=Manifolds"&gt;Click here &lt;/a&gt;for pricing on Manifold Stacking Units from Vaplock.&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;a href="http://4.bp.blogspot.com/_WC228aX0cWw/SGpBUsAdWWI/AAAAAAAAAJo/a9iZ8hBMRJQ/s1600-h/SV-113-eleven-lines.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5218054941928413538" style="CURSOR: hand" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SGpBUsAdWWI/AAAAAAAAAJo/a9iZ8hBMRJQ/s320/SV-113-eleven-lines.jpg" border="0" /&gt;&lt;/a&gt;&lt;a href="http://4.bp.blogspot.com/_WC228aX0cWw/SGpBVAfLp6I/AAAAAAAAAJ4/0K2xxsWd2tM/s1600-h/VT-002-shown-in-6-port-mani.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5218054947425986466" style="CURSOR: hand" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SGpBVAfLp6I/AAAAAAAAAJ4/0K2xxsWd2tM/s320/VT-002-shown-in-6-port-mani.jpg" border="0" /&gt;&lt;/a&gt;&lt;a href="http://2.bp.blogspot.com/_WC228aX0cWw/SGpBUzlemdI/AAAAAAAAAJw/yHo2rTn7NGQ/s1600-h/SV-113-stacked-eleven-lines.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5218054943962733010" style="CURSOR: hand" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/SGpBUzlemdI/AAAAAAAAAJw/yHo2rTn7NGQ/s320/SV-113-stacked-eleven-lines.jpg" border="0" /&gt;&lt;/a&gt;&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SGpC-ef_bzI/AAAAAAAAAKA/5HTrMM0ARFI/s1600-h/SV-114-eleven-lines.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5218056759368707890" style="CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SGpC-ef_bzI/AAAAAAAAAKA/5HTrMM0ARFI/s320/SV-114-eleven-lines.jpg" border="0" /&gt;&lt;/a&gt;&lt;/span&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-2982067326830953625?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=V6KLWEcx"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=2jtMKUJR"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/mnivcT86C2A" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock&amp;level1=Manifolds" title="How Many Waste Lines?  Use Vaplock Manifold Stack Units" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/2982067326830953625/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=2982067326830953625" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2982067326830953625?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/2982067326830953625?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/mnivcT86C2A/how-many-waste-lines-use-vaplock.html" title="How Many Waste Lines?  Use Vaplock Manifold Stack Units" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://1.bp.blogspot.com/_WC228aX0cWw/SGpG7SgTQ_I/AAAAAAAAAKI/nCvnmIh8ucY/s72-c/STACKED-MANIFOLD_30-LINES-W.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/07/how-many-waste-lines-use-vaplock.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0IDQXczfCp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-8412437633441825379</id><published>2008-06-16T15:41:00.012-04:00</published><updated>2008-10-06T12:46:10.984-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:46:10.984-04:00</app:edited><title>Vaplock Carboy &amp; Pail Manifolds Provide Versatile Connections to HPLC Waste Lines</title><content type="html">&lt;ul&gt;&lt;li&gt;&lt;a href="http://3.bp.blogspot.com/_WC228aX0cWw/SFbD3V1N-8I/AAAAAAAAAJA/8jJwQ0lYwbA/s1600-h/CM-PM.JPG"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5212568974248508354" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://3.bp.blogspot.com/_WC228aX0cWw/SFbD3V1N-8I/AAAAAAAAAJA/8jJwQ0lYwbA/s400/CM-PM.JPG" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; 3-Port, 6-Port and 9-port manifolds for large and small bore tubing&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Cam locks permit quick disengagement&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;Adapt to 83B and 53B 70mm, 63mm, 61mm and 100-415 carboys and pails&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-family:trebuchet ms;"&gt;Carboy and drum manifolds permit multiple waste lines of varying size and type to be connected to the container of your choice. Three-port manifolds have three 1/4” NPT ports; six-port manifolds have five 1/4” NPT ports radially, and one 1/2” NPT top port; 9-port manifolds have eight 1/4-28 ports radially, one 1/4” NPT top port. Cam locks have 1/2” or larger drain orifices.&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-family:trebuchet ms;"&gt;If more tubing lines need connecting than a manifold will permit, use of the appropriate stacking unit will increase the number of ports to suit your needs.&lt;br /&gt;The PM-305 or PM-605 panel mount manifolds may also be used if a nonstandard cap is present; drill a 1.125” diameter hole (max 1/2” depth) in the cap and thread in place for a secure seal.&lt;br /&gt;&lt;br /&gt;PLEASE NOTE THAT IT IS NOT POSSIBLE TO GROUND DRUM, PAIL, GLASS BOTTLE AND CARBOY (NON-JUSTRITE®) CONTAINERS; THIS MAY RESULT IN A SAFETY HAZARD WITH FLAMMABLE SOLVENTS.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-family:trebuchet ms;"&gt;Contact Kinesis Inc. for more information about a variety of special manifolds for your existing waste containers. &lt;/span&gt;&lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;E-mail&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; us or &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock&amp;amp;level1=Manifolds"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;"&gt; for a listing of part numbers and pricing.&lt;/span&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;span style="font-size:130%;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-8412437633441825379?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=mS3j1Qnd"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=J6ZOGkOB"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/0PUKWoGn7TQ" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock&amp;level1=Manifolds" title="Vaplock Carboy &amp; Pail Manifolds Provide Versatile Connections to HPLC Waste Lines" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/8412437633441825379/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=8412437633441825379" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8412437633441825379?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/8412437633441825379?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/0PUKWoGn7TQ/vaplock-carboy-pail-manifolds-provide.html" title="Vaplock Carboy &amp; Pail Manifolds Provide Versatile Connections to HPLC Waste Lines" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://3.bp.blogspot.com/_WC228aX0cWw/SFbD3V1N-8I/AAAAAAAAAJA/8jJwQ0lYwbA/s72-c/CM-PM.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/06/vaplock-carboy-pail-manifolds-provide.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0INSXY7eyp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-6143118716669319923</id><published>2008-06-11T14:25:00.007-04:00</published><updated>2008-10-06T12:46:38.803-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:46:38.803-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="SLE" /><category scheme="http://www.blogger.com/atom/ns#" term="sample prep" /><category scheme="http://www.blogger.com/atom/ns#" term="Forensic" /><category scheme="http://www.blogger.com/atom/ns#" term="Biotage" /><category scheme="http://www.blogger.com/atom/ns#" term="supported liquid extraction" /><category scheme="http://www.blogger.com/atom/ns#" term="SPE" /><category scheme="http://www.blogger.com/atom/ns#" term="solid phase extraction" /><title>Biotage/ISOLUTE HM-N Supported Liquid Extraction</title><content type="html">&lt;span style="font-size:130%;"&gt;&lt;span style="font-family:trebuchet ms;"&gt;A new publication has highlighted Biotage HM-N Supported Liquid Extraction for a Forensic Application. &lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;img style="DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 320px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://www.biotage.com/graphics/15107.jpg" border="0" /&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;strong&gt;&lt;a href="http://www.biotage.com/graphics/15107.jpg"&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;de Korompay, A., et al., Supported liquid–liquid extraction of the active ingredient (3, 4-methylenedioxymethylamphetamine) from ecstasy tablets for isotopic analysis. Journal of Chromatography A, 2008. 1178(1-2): p. 1-8.&lt;/span&gt; &lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;strong&gt;Abstract: &lt;/strong&gt;A method was developed for the isolation of 3,4-methylenedioxymethylamphetamine (MDMA) and other active ingredients from illicit ecstasy tablets. The method employed supported liquid extraction (SLE) with cartridges containing a modified form of diatomaceous earth. The method developed was simple and robust and the extract could be analysed directly, by GC–MS, to identify ingredients and reduced in volume for isotope ratio MS analysis of both δ13C and δ15N. The technique was shown to be highly reproducible, independent of the tablet matrix and considerably faster than existing liquid–liquid extraction methods. Crucially, no significant isotopic fractionation was observed as a result of the extraction process.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:trebuchet ms;"&gt;&lt;span style="font-size:130%;"&gt;Kinesis Inc. is the exclusive distributor of Biotage/ISOLUTE SPE products for non-pharma applications in New York and New England. Contact our office for more information on HM-N SLE or any ISOLUTE, EVOLUTE or other SPE products. &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=ISOLUTE&amp;amp;level1=Cartridge&amp;amp;level2=HM-N"&gt;&lt;span style="font-size:130%;"&gt;Click here for pricing on HM-N cartridges.&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:Trebuchet MS;"&gt;&lt;span style="font-size:130%;"&gt;A listing of other Forensic Methods using Biotage/ISOLUTE products are available for download by &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/displayapplication.asp?marketsector=Drugs%20of%20Abuse%20and%20Forensic&amp;amp;subsector=SPE"&gt;&lt;span style="font-size:130%;"&gt;clicking here&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-6143118716669319923?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=RGfGYfWh"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=A0nnLpOa"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/6gHJV8SjcaM" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/bitem2.asp?category=ISOLUTE&amp;level1=Cartridge&amp;level2=HM-N" title="Biotage/ISOLUTE HM-N Supported Liquid Extraction" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/6143118716669319923/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=6143118716669319923" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6143118716669319923?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/6143118716669319923?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/6gHJV8SjcaM/biotageisolute-hm-n-supported-liquid.html" title="Biotage/ISOLUTE HM-N Supported Liquid Extraction" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/06/biotageisolute-hm-n-supported-liquid.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0EHSH49fSp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-1450498466950714340</id><published>2008-06-04T09:10:00.010-04:00</published><updated>2008-10-06T12:47:19.065-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:47:19.065-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="Organic Vapor Filter" /><category scheme="http://www.blogger.com/atom/ns#" term="HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="EF-100" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent delivery" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>Minimize Solvent Vapors with Vaplock Filters for Closed System HPLC</title><content type="html">&lt;ul&gt;&lt;br /&gt;&lt;li&gt;&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SEaW5pme78I/AAAAAAAAAIY/k-m4yO5j91o/s1600-h/EF-100-WEB.jpg"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5208015936264531906" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SEaW5pme78I/AAAAAAAAAIY/k-m4yO5j91o/s200/EF-100-WEB.jpg" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:arial;font-size:130%;"&gt; Minimize vapors by adsorption before they enter the lab environment. &lt;/span&gt;&lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Tested for breakthrough with a variety of HPLC solvents.&lt;/span&gt;&lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Constructed of activated coconut shell carbon and silica desiccant, with Polypropylene housing&lt;/span&gt;&lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Economically priced&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;span style="font-family:arial;"&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Reduce your emissions from solvent waste containers by installing a Vaplock vapor filter, which may be adapted to a number of low pressure organic vapor sources. The filters have been tested for breakthrough with several common solvents used in HPLC. Below, the chart shows manufacturer recommended replacement periods by solvent, based on empirical data from collected gas samples analyzed on a gas chromatograph. The solvent samples were tested at 100% concentration; for HPLC use, water-solvent mixtures from gradients may have longer breakthrough periods. Spent cartridges should be disposed in accordance with local safety codes.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5208015374020559122" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SEaWY7FEwRI/AAAAAAAAAIQ/v9DLnlfFe6Q/s400/Vapor+Filters.JPG" border="0" /&gt; Organic Vapor Filters are available singly as P/N EF-100 or in convenient packs of five filters in P/N EF-100V. &lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=VapLock&amp;amp;level1=VaporFiltersandIndicators&amp;amp;level2=OrganicVaporFilter"&gt;Click here for pricing and buy online!&lt;/a&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SEaZb09poUI/AAAAAAAAAIg/GGaEGFOXAVo/s1600-h/EF-102-installed.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5208018722453299522" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SEaZb09poUI/AAAAAAAAAIg/GGaEGFOXAVo/s200/EF-102-installed.jpg" border="0" /&gt;&lt;/a&gt;Vapor Filter Breakthrough Indicators are also available. These make it convenient to monitor change out periods if you use solvent mixtures or varying flow rates. P/N EF-102 changes color from pink to magenta when solvent vapors break through the filter. &lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=VapLock&amp;amp;level1=VaporFiltersandIndicators&amp;amp;level2=VapLockColorIndicator"&gt;Click here for pricing and buy online!&lt;/a&gt;&lt;br /&gt;&lt;/p&gt;&lt;/span&gt;&lt;br /&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-1450498466950714340?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=l6SS3ZAS"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=CYp3fPjJ"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/_MkYY1sN8WM" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock" title="Minimize Solvent Vapors with Vaplock Filters for Closed System HPLC" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/1450498466950714340/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=1450498466950714340" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/1450498466950714340?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/1450498466950714340?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/_MkYY1sN8WM/solvent-vapor-filters-for-closed-system.html" title="Minimize Solvent Vapors with Vaplock Filters for Closed System HPLC" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://1.bp.blogspot.com/_WC228aX0cWw/SEaW5pme78I/AAAAAAAAAIY/k-m4yO5j91o/s72-c/EF-100-WEB.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/06/solvent-vapor-filters-for-closed-system.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0ECRX85eip7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-5717281569410661633</id><published>2008-05-23T21:12:00.006-04:00</published><updated>2008-10-06T12:47:44.122-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:47:44.122-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="tubing connection" /><category scheme="http://www.blogger.com/atom/ns#" term="low pressure liquid chromatography" /><category scheme="http://www.blogger.com/atom/ns#" term="medium pressure liquid chromatography" /><category scheme="http://www.blogger.com/atom/ns#" term="omnifit" /><title>Inert and Low Dead-Volume Tubing Connections Using Omnifit Components</title><content type="html">&lt;span style="font-family:arial;font-size:130%;"&gt;Save time and ensure a leak-free connection with pre-assembled tubing sets. Kinesis Inc. offer complete tubing sets for your convenience.&lt;/span&gt;&lt;br /&gt;&lt;img id="BLOGGER_PHOTO_ID_5203748455441009394" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SDdtpksMivI/AAAAAAAAAHw/xRHSTMlsmYY/s400/tubing+sets.JPG" border="0" /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Reduce time spent on assembly, purchasing and inventory management&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Assembled with Type S or Type P Omni-Lok™ ferrules and close-packing, glass-filled polypropylene fitting nuts&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Available with chemically-resistant PTFE, PEEK™ or Tefzel® ferrules&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Range of PTFE tubing diameters and any length available&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Color coded fitting nuts for easy line identification&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Kits to plumb complete instruments can be supplied loose or mesh-wrapped in bundles&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Single Tubing Sets&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;&lt;span style="font-family:arial;"&gt;&lt;span style="font-size:130%;"&gt;Single tubing sets consist of the Omni-Lok™ fitting system and PTFE tubing in 1/16” and 1/8” O.D. sizes. These tubing sets are assembled and cut to your desired length with one or both ends fitted. Fitting nuts are available in eight different colors for easy line identification.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:130%;"&gt;Mesh-wrapped Tubing Sets&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;Multiple single tubing sets can be bundled with a polyester mesh wrap to provide a neatly packaged one-piece assembly. This eliminates unmanageable loose tubing within an instrument. A bundled tubing set can be specified with any combination of colored fitting nuts, PTFE tubing and Omni-Lok™ ferrule types.&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;strong&gt;The Omni-Lok Fitting System&lt;/strong&gt; &lt;/span&gt;&lt;br /&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;span style="font-size:130%;"&gt;The Omni-Lok fitting system is made up of a permanently attached PTFE, PEEK™ or Tefzel® ferrule and a close-packing, glass-filled polypropylene fitting nut. This system accommodates hard wall tubing sizes of 1/16” and 1/8” O.D.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;Kinesis Inc. also offer custom tube sets using Omnifit Gripper ferrules, Inverted Cone fittings, and other custom solutions. &lt;a href="mailto:sales@kinesis-usa.com"&gt;E-mail&lt;/a&gt; us for details.&lt;/span&gt;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-5717281569410661633?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=r29rsDI5"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=Gr0lnpSY"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/19_IiU67qc8" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp" title="Inert and Low Dead-Volume Tubing Connections Using Omnifit Components" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/5717281569410661633/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=5717281569410661633" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5717281569410661633?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5717281569410661633?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/19_IiU67qc8/inert-and-low-dead-volume-tubing.html" title="Inert and Low Dead-Volume Tubing Connections Using Omnifit Components" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://4.bp.blogspot.com/_WC228aX0cWw/SDdtpksMivI/AAAAAAAAAHw/xRHSTMlsmYY/s72-c/tubing+sets.JPG" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/05/inert-and-low-dead-volume-tubing.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0EMRHg8eCp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-3526019027837662867</id><published>2008-05-12T09:20:00.009-04:00</published><updated>2008-10-06T12:48:05.670-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:48:05.670-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="Organic Vapor Filter" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="bottle cap" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent bottle" /><category scheme="http://www.blogger.com/atom/ns#" term="omnifit" /><category scheme="http://www.blogger.com/atom/ns#" term="t series" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent delivery" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><category scheme="http://www.blogger.com/atom/ns#" term="HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE" /><category scheme="http://www.blogger.com/atom/ns#" term="q series" /><category scheme="http://www.blogger.com/atom/ns#" term="c series" /><category scheme="http://www.blogger.com/atom/ns#" term="Solvent Waste Manifold" /><title>Secure HPLC Solvent Delivery with VAPLOCK™ Closed Systems</title><content type="html">&lt;span style="font-family:arial;font-size:130%;"&gt;VAPLOCK™ Closed Systems for solvent containment minimizes leaks, spills, and vapor escape from solvent waste and supply containers. Use supply kit VK-204 to provide an effective means of sealed solvent delivery, and select from the waste containment kits to collect solvent wastes with minimal vapor release. All Vaplock™ products are designed for ease of use and adaptability, and will conform to a broad array of standard laboratory solvent containers. &lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SChFustYx7I/AAAAAAAAAHY/vqRg3qtEevo/s1600-h/VK-204.jpg"&gt;&lt;/a&gt;&lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/SChIzstYx8I/AAAAAAAAAHg/XNjh2EFQ9WE/s1600-h/VK-204.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5199485822811293634" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/SChIzstYx8I/AAAAAAAAAHg/XNjh2EFQ9WE/s320/VK-204.jpg" border="0" /&gt;&lt;/a&gt;Use a Vaplock™ Solvent Delivery Kit to minimize vapor release while supplying solvents to your system. Threaded tubing connections (for 1/8” and 1.8 - 2.0mm OD) adapt to an inert PTFE bottle cap on a 2 Liter safety-coated borosilicate bottle, while a 2-way emission control valve allows air to enter the reservoir as solvent is removed. The valve also acts as a pressure relief, venting between 0.5 and 1 psi. Two 10 micron UHMWPE solvent filters, five replacement filter elements, Teflon® 1/4-28 plug and 10 feet of 1/8” OD PTFE tubing are also included. VK-204 is for Reversed Phase solvents only. Normal Phase solvent kits are available - please inquire.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;font-size:130%;"&gt;&lt;a href="mailto:sales@kinesis-usa.com?subject=VK204"&gt;E-mail us&lt;/a&gt; for more information on this kit or pricing on separate components to adapt to your existing HPLC system. &lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-3526019027837662867?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=cKXoliLZ"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=VCMTptrP"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/p96VWGoxejA" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock" title="Secure HPLC Solvent Delivery with VAPLOCK™ Closed Systems" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/3526019027837662867/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=3526019027837662867" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/3526019027837662867?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/3526019027837662867?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/p96VWGoxejA/vaplock-closed-systems-secure-solvent.html" title="Secure HPLC Solvent Delivery with VAPLOCK™ Closed Systems" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://1.bp.blogspot.com/_WC228aX0cWw/SChIzstYx8I/AAAAAAAAAHg/XNjh2EFQ9WE/s72-c/VK-204.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/05/vaplock-closed-systems-secure-solvent.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0AAR344fCp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-4537128682471891108</id><published>2008-05-09T09:35:00.009-04:00</published><updated>2008-10-06T12:49:06.034-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:49:06.034-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="hplc detector lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="D2 lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="replacement lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="deuterium lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="discount" /><title>Savings with Kinesis Long Life HPLC Replacement Deuterium Lamp X-Packs</title><content type="html">&lt;a href="http://2.bp.blogspot.com/_WC228aX0cWw/SCRVGX1-DaI/AAAAAAAAAHI/XYMc4MAYpaY/s1600-h/95E_xpacks.jpg"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5198373437860351394" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/SCRVGX1-DaI/AAAAAAAAAHI/XYMc4MAYpaY/s400/95E_xpacks.jpg" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;p&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Great Savings on Long-life Deuterium Lamps with Xtra Value Packs&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;The Kinesis range of replacement Deuterium lamps, which already offer great savings over lamps from the original equipment manufacturers (OEM’s), are now available in our X-pack multi-packs for even further savings. The X-packs are based on our long-life range – guaranteed for 2000 hrs – so not only do you get a great price you also get a lamp with the same or in many cases better lifetime than an OEM lamp.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Kinesis manufactures / pre-aligns Deuterium lamps for independent service companies, distributors and end users. The bare lamps we use are supplied by the same manufacturers used by the OEM companies and Kinesis lamps are precision aligned and tested at our facility in accordance with our stringent ISO 9000 certified procedures.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;All Kinesis lamps are certified recording the date of manufacture, serial number, tester’s name and the intensity counts reading for future traceability. Only lamps made to the strictest tolerances receive the Kinesis Guaranteed Lamp Seal. This means that Kinesis provides lamps without any compromise on quality compared with OEM specifications.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;KINESIS LONG-LIFE LAMP X-PACKS&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Based on Long-Life 2000 Hr lamps &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;No Compromise on Quality &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Multi-Lamp packs of six pieces offer great savings&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Long-life Lamps available online for &lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=HPLCInstrumentSpares!Lamps&amp;amp;level1=DetectorLampXtraValuePacks&amp;amp;level2=Agilent"&gt;Agilent&lt;/a&gt; and &lt;a href="http://www.kinesis-usa.com/bitem2.asp?category=HPLCInstrumentSpares!Lamps&amp;amp;level1=DetectorLampXtraValuePacks&amp;amp;level2=Waters"&gt;Waters&lt;/a&gt;. &lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Other lamps available on request - Shimadzu, Varian, and more!&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;p&gt;Enter PROMO CODE "USA10" on the &lt;a href="http://www.kinesis-usa.com/"&gt;Kinesis Inc. Home Page&lt;/a&gt; to get 10% off your purchase of single replacement lamps or our Long Life Lamp Xtra Value Packs.&lt;br /&gt;&lt;/p&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-4537128682471891108?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=biKVX0Yi"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=eeSNiIuZ"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/cFeXm1D7Ko4" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/product_feature_technique.asp" title="Savings with Kinesis Long Life HPLC Replacement Deuterium Lamp X-Packs" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/4537128682471891108/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=4537128682471891108" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/4537128682471891108?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/4537128682471891108?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/cFeXm1D7Ko4/kinesis-long-life-deuterium-lamp-x.html" title="Savings with Kinesis Long Life HPLC Replacement Deuterium Lamp X-Packs" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://2.bp.blogspot.com/_WC228aX0cWw/SCRVGX1-DaI/AAAAAAAAAHI/XYMc4MAYpaY/s72-c/95E_xpacks.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/05/kinesis-long-life-deuterium-lamp-x.html</feedburner:origLink></entry><entry gd:etag="W/&quot;DEAMQHszeyp7ImA9WxdTE0k.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-5554313708263850333</id><published>2008-05-06T10:01:00.007-04:00</published><updated>2008-05-09T11:26:21.583-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-05-09T11:26:21.583-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="D2 lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="promotion" /><category scheme="http://www.blogger.com/atom/ns#" term="deuterium lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="discount" /><category scheme="http://www.blogger.com/atom/ns#" term="HPLC lamp" /><category scheme="http://www.blogger.com/atom/ns#" term="omnifit" /><category scheme="http://www.blogger.com/atom/ns#" term="Solvent Waste Manifold" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>New Home on the Web for the Kinesis Chromatography Blog</title><content type="html">&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5197267012710981490" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://4.bp.blogspot.com/_WC228aX0cWw/SCBmz89-X3I/AAAAAAAAAG4/qkQyD-cIUts/s320/Kinesis_Inc_Logo_col_blog.jpg" border="0" /&gt;The Kinesis Chromatography Blog just got a new home on the web at &lt;/span&gt;&lt;a href="http://www.kinesishplc.com/"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;www.kinesishplc.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;. This new domain is an extension of services and information from our corporate site at &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-family:arial;"&gt;. The mission of our new blog site is to get our customers a fast, easy, and secure way to access technical and promotional information on our products with a key focus on our newest and most popular items.&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;"&gt;Visit our blog to find exclusive promotions that may not be available elsewhere. For example, blog visitors now have the opportunity to save $100 off any Vaplock Closed System Waste Containment Kit.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;"&gt;You'll also find technical product information that will help you make better purchase decisions for your HPLC and GC applications. Look for posts on Omnifit, Vaplock and SGE products to learn more about how they can help you improve results, increase reliability, and operate safely.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;"&gt;You can always contact us &lt;a href="mailto:sales@kinesis-usa.com?subject=kinesishplc.com"&gt;via e-mail &lt;/a&gt;at &lt;a href="mailto:sales@kinesis-usa.com"&gt;sales@kinesis-usa.com&lt;/a&gt;, or by filling out our web-based contact form by &lt;a href="http://www.kinesis-usa.com/contact.asp"&gt;clicking here&lt;/a&gt;.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;div&gt;&lt;span style="font-family:arial;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-5554313708263850333?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=MigxUQwQ"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=bcp15txT"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/D91qKhysDzg" height="1" width="1"/&gt;</content><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/5554313708263850333/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=5554313708263850333" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5554313708263850333?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/5554313708263850333?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/D91qKhysDzg/new-home-on-web-for-kinesis.html" title="New Home on the Web for the Kinesis Chromatography Blog" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://4.bp.blogspot.com/_WC228aX0cWw/SCBmz89-X3I/AAAAAAAAAG4/qkQyD-cIUts/s72-c/Kinesis_Inc_Logo_col_blog.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/05/new-home-on-web-for-kinesis.html</feedburner:origLink></entry><entry gd:etag="W/&quot;CEQDRXk_eSp7ImA9WxdTEE0.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-3793359062190950098</id><published>2008-04-15T10:33:00.007-04:00</published><updated>2008-05-05T11:46:14.741-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-05-05T11:46:14.741-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="promotion" /><category scheme="http://www.blogger.com/atom/ns#" term="Closed System HPLC" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent bottle" /><category scheme="http://www.blogger.com/atom/ns#" term="hplc solvent delivery" /><category scheme="http://www.blogger.com/atom/ns#" term="Solvent Waste Manifold" /><category scheme="http://www.blogger.com/atom/ns#" term="Vaplock" /><title>Vaplock™ HPLC Solvent Waste Containment Kits On Sale!</title><content type="html">&lt;div align="center"&gt;&lt;span style="font-family:arial;font-size:180%;color:#ff0000;"&gt;&lt;strong&gt;EXCLUSIVE BLOG PROMOTION!&lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;$100 Off Vaplock 2-gallon and 5-gallon Waste Containment Kits&lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;May not be combined with any other discount, offer, or promotion.&lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Expires May 31, 2008&lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;a href="http://3.bp.blogspot.com/_WC228aX0cWw/SAS90ZfvjZI/AAAAAAAAAGE/mLJP3AfBKTE/s1600-h/VK-003.jpg"&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5189481378532527506" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" height="269" alt="" src="http://3.bp.blogspot.com/_WC228aX0cWw/SAS90ZfvjZI/AAAAAAAAAGE/mLJP3AfBKTE/s320/VK-003.jpg" width="244" border="0" /&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Plumb multiple solvent lines securely to a waste container and reduce vapor emissions by using a Vaplock™ Waste Containment Kit. The heart of the system is a Justrite® Polyethylene waste can, which includes 2 quick disconnects for ease of use (choose either Polypropylene with EPDM o-rings, or Stainless Steel and Teflon® for more aggressive fluids). A 6-port waste manifold and fittings kit adapt to common HPLC tubing requirements, while a 5-pack of activated carbon and silica filters reduce vapors from the container vent. Antistatic wire grounds the system during use. 1, 2, and 5 gallon container sizes available.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:Arial;font-size:130%;"&gt;&lt;strong&gt;&lt;span style="color:#ff0000;"&gt;PROMOTIONAL PRICES&lt;/span&gt;&lt;/strong&gt; &lt;span style="font-size:85%;"&gt;(Exp. 5/31/2008)&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Vaplock™ Waste Containment Kits with Polypropylene/EPDM Connections:&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;VK-002 - VAPLOCK WASTE CONTAINMENT KIT, includes 2-gallon Justrite can with Polypropylene quick disconnects, 6-port waste manifold, fittings kit, filter adapter and filter 5-pack&lt;br /&gt;$485.00 EACH&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;VK-004 - &lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;VAPLOCK CLOSED SYSTEM WASTE CONTAINMENT KIT, includes 5-gallon Justrite can with Polypropylene quick disconnects, 6-port waste manifold, fittings kit, filter adapter and filter 5-pack&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;$505.00 EACH&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Vaplock™ Waste Containment Kits with Stainless-Steel/PTFE Connections:&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;VK-003 - VAPLOCK WASTE CONTAINMENT KIT, includes 2-gallon Justrite can with Stainless Steel quick disconnects and Teflon O-rings, 6-port waste manifold, fittings kit, filter adapter, filter 5-pack, and antistatic wires&lt;br /&gt;$865.00 EACH&lt;br /&gt;&lt;br /&gt;VK-005 - VAPLOCK WASTE CONTAINMENT KIT, includes 5-gallon Justrite can with Stainless Steel quick disconnects with Teflon O-rings, 6-port waste manifold, fittings kit, filter adapter, filter 5-pack, and anti-static wires&lt;br /&gt;$885.00 EACH&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-3793359062190950098?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=rVSS8W1w"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=Gov0Msya"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/B8rXYI9Vc98" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp?category=VapLock" title="Vaplock™ HPLC Solvent Waste Containment Kits On Sale!" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/3793359062190950098/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=3793359062190950098" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/3793359062190950098?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/3793359062190950098?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/B8rXYI9Vc98/vaplock-hplc-solvent-waste-containment.html" title="Vaplock™ HPLC Solvent Waste Containment Kits On Sale!" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://3.bp.blogspot.com/_WC228aX0cWw/SAS90ZfvjZI/AAAAAAAAAGE/mLJP3AfBKTE/s72-c/VK-003.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/04/vaplock-hplc-solvent-waste-containment.html</feedburner:origLink></entry><entry gd:etag="W/&quot;C0AMRnsyeCp7ImA9WxRQE0w.&quot;"><id>tag:blogger.com,1999:blog-3551087925725681317.post-3063783716367680186</id><published>2008-04-11T10:43:00.019-04:00</published><updated>2008-10-06T12:49:47.590-04:00</updated><app:edited xmlns:app="http://www.w3.org/2007/app">2008-10-06T12:49:47.590-04:00</app:edited><category scheme="http://www.blogger.com/atom/ns#" term="low pressure liquid chromatography" /><category scheme="http://www.blogger.com/atom/ns#" term="PTFE" /><category scheme="http://www.blogger.com/atom/ns#" term="promotion" /><category scheme="http://www.blogger.com/atom/ns#" term="discount" /><category scheme="http://www.blogger.com/atom/ns#" term="medium pressure liquid chromatography" /><category scheme="http://www.blogger.com/atom/ns#" term="omnifit" /><category scheme="http://www.blogger.com/atom/ns#" term="LC column" /><category scheme="http://www.blogger.com/atom/ns#" term="glass column" /><category scheme="http://www.blogger.com/atom/ns#" term="fow chemistry" /><title>Omnifit Precision Glass Columns for Low and Mid Pressure Chromatography</title><content type="html">&lt;ul&gt;&lt;li&gt;&lt;img id="BLOGGER_PHOTO_ID_5188002590402430786" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://2.bp.blogspot.com/_WC228aX0cWw/R_983ma-R0I/AAAAAAAAAFU/hejidxeLmvk/s400/50+AF.jpg" border="0" /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Pressure ratings to 1200 psi (80 bar)*&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;S&lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;olvent resistant&lt;/li&gt;&lt;li&gt;Biocompatible&lt;/li&gt;&lt;li&gt;Fixed or adjustable height&lt;/li&gt;&lt;li&gt;Robust and easy to use&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;/span&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Adjustable Height&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Up to 80 mm of height adjustment is possible with an adjustable end piece (plunger). Our design gives the user fine control over the adjustment, minimizing the risk of disturbance to the packed bed. &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Whether you choose a fixed or adjustable height column, you will have the following options available:&lt;/span&gt;&lt;br /&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Standard aqueous system&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Made from borosilicate glass and PTFE, and supplied with 25 μm polyethylene (PE) frits fitted, the columns are ready for use in the majority of applications.&lt;/span&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Solvent resistant system&lt;/strong&gt;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Simply replacing the PE frit fitted in each end piece, with the PTFE version supplied in the frit kit gives a totally inert system able to cope with the harshest &lt;a href="http://1.bp.blogspot.com/_WC228aX0cWw/R_971Wa-RzI/AAAAAAAAAFM/5hdx-Y4NT-c/s1600-h/10+AF.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5188001452236097330" style="FLOAT: right; MARGIN: 0px 0px 10px 10px; CURSOR: hand" alt="" src="http://1.bp.blogspot.com/_WC228aX0cWw/R_971Wa-RzI/AAAAAAAAAFM/5hdx-Y4NT-c/s400/10+AF.jpg" border="0" /&gt;&lt;/a&gt;laboratory chemicals. &lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Column Tubing Connections&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;All columns are supplied with a ready-assembled tubing set to connect into each end of the column. 1/4”-28 UNF fittings are supplied as standard and connect straight into the colored cap on each end of the column. Alternatively, M6 caps are supplied, enabling you to easily change the column over to an M6 fitting system. &lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;&lt;strong&gt;Replacement Parts and Accessories&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:arial;font-size:130%;"&gt;Replacement glass columns, fixed end pieces, adjustable end pieces, frits and ‘o’-rings are available separately. Accessories include frit tools, packing sleeves, column jackets, silicone seals, septum injectors and a bleed valve.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:Arial;font-size:130%;"&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="font-family:Arial;font-size:130%;"&gt;Contact &lt;a href="mailto:sales@kinesis-usa.com"&gt;sales@kinesis-usa.com&lt;/a&gt; for more information on Omnifit columns and accessories.&lt;/span&gt;&lt;/p&gt;&lt;br /&gt;&lt;span style="font-family:Trebuchet MS;font-size:130%;"&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;Phone Toll Free: (866) 934-6353 Fax: (518) 490-1235&lt;br /&gt;E-mail: &lt;/span&gt;&lt;a href="mailto:sales@kinesis-usa.com"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;sales@kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt; Web: &lt;/span&gt;&lt;a href="http://www.kinesis-usa.com/"&gt;&lt;span style="font-family:trebuchet ms;font-size:130%;color:#33ff33;"&gt;www.kinesis-usa.com&lt;/span&gt;&lt;/a&gt;&lt;span style="font-family:trebuchet ms;color:#33ff33;"&gt; &lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/3551087925725681317-3063783716367680186?l=www.kinesishplc.com' alt='' /&gt;&lt;/div&gt;&lt;div class="feedflare"&gt;
&lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=puTqCqmS"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=41" border="0"&gt;&lt;/img&gt;&lt;/a&gt; &lt;a href="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?a=WwnrB7sp"&gt;&lt;img src="http://feeds.feedburner.com/~f/ChromatographyProductsFromKinesisInc?d=42" border="0"&gt;&lt;/img&gt;&lt;/a&gt;
&lt;/div&gt;&lt;img src="http://feeds.feedburner.com/~r/ChromatographyProductsFromKinesisInc/~4/Vbcfu5nKRbs" height="1" width="1"/&gt;</content><link rel="related" href="http://www.kinesis-usa.com/displaycategory.asp" title="Omnifit Precision Glass Columns for Low and Mid Pressure Chromatography" /><link rel="replies" type="application/atom+xml" href="http://www.kinesishplc.com/feeds/3063783716367680186/comments/default" title="Post Comments" /><link rel="replies" type="text/html" href="https://www.blogger.com/comment.g?blogID=3551087925725681317&amp;postID=3063783716367680186" title="0 Comments" /><link rel="edit" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/3063783716367680186?v=2" /><link rel="self" type="application/atom+xml" href="http://www.blogger.com/feeds/3551087925725681317/posts/default/3063783716367680186?v=2" /><link rel="alternate" type="text/html" href="http://feedproxy.google.com/~r/ChromatographyProductsFromKinesisInc/~3/Vbcfu5nKRbs/omnifit-precision-glass-columns-for-lc.html" title="Omnifit Precision Glass Columns for Low and Mid Pressure Chromatography" /><author><name>Kinesis Inc.</name><uri>http://www.blogger.com/profile/01752552872015152621</uri><email>sales@kinesis-usa.com</email><gd:extendedProperty name="OpenSocialUserId" value="11944720025840076984" /></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="http://2.bp.blogspot.com/_WC228aX0cWw/R_983ma-R0I/AAAAAAAAAFU/hejidxeLmvk/s72-c/50+AF.jpg" height="72" width="72" /><thr:total xmlns:thr="http://purl.org/syndication/thread/1.0">0</thr:total><feedburner:origLink>http://www.kinesishplc.com/2008/04/omnifit-precision-glass-columns-for-lc.html</feedburner:origLink></entry></feed>
