<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electronica Pascual</title>
	<atom:link href="http://electronicapascual.com/blog/?feed=rss2" rel="self" type="application/rss+xml" />
	<link>http://electronicapascual.com/blog</link>
	<description>Información sobre electronica, tecnologia y telecomunicaciones</description>
	<lastBuildDate>Wed, 21 Oct 2020 17:31:37 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.5.18</generator>
	<item>
		<title>Reparación O Restauración</title>
		<link>http://electronicapascual.com/blog/?p=3525</link>
					<comments>http://electronicapascual.com/blog/?p=3525#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Wed, 21 Oct 2020 17:31:37 +0000</pubDate>
				<category><![CDATA[Sin categoría]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3525</guid>

					<description><![CDATA[Una unidad de alimentación conmutada de una maquina herramienta. Un condensador se incendia causando graves daños. Sometemos la placa a : &#8211; Limpieza en maño ultrasonico. -Verificación de los componentes. -Sustitución del condensador quemado. Se realiza la prueba con una alimentación de CA limitada en intensidad. Posteriormente la fuente es sometida a carga.]]></description>
										<content:encoded><![CDATA[<p>Una unidad de alimentación conmutada de una maquina herramienta.</p>
<p>Un condensador se incendia causando graves daños.</p>
<p><a href="https://www.flickr.com/photos/22413231@N07/50512949043/in/dateposted-public/"><img loading="lazy" src="https://live.staticflickr.com/65535/50512949043_3cb412fd1d_z.jpg" alt="F2" width="480" height="640" /></a></p>
<p>Sometemos la placa a :</p>
<p>&#8211; Limpieza en maño ultrasonico.</p>
<p>-Verificación de los componentes.</p>
<p>-Sustitución del condensador quemado.</p>
<p><a href="https://www.flickr.com/photos/22413231@N07/50512949273/in/dateposted-public/"><img loading="lazy" src="https://live.staticflickr.com/65535/50512949273_59852feda7.jpg" alt="F1" width="500" height="231" /></a></p>
<p>Se realiza la prueba con una alimentación de CA limitada en intensidad.</p>
<p>Posteriormente la fuente es sometida a carga.</p>
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3525</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>En el banco de trabajo KROHNE</title>
		<link>http://electronicapascual.com/blog/?p=3498</link>
					<comments>http://electronicapascual.com/blog/?p=3498#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 26 Aug 2020 00:16:18 +0000</pubDate>
				<category><![CDATA[Breves]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3498</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" class="decoded alignleft" src="https://live.staticflickr.com/4626/28313989009_e602b10b66_z.jpg" alt="https://live.staticflickr.com/4626/28313989009_e602b10b66_z.jpg" width="414" height="311" /></p>
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3498</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>En el banco de trabajo HP5343A</title>
		<link>http://electronicapascual.com/blog/?p=3493</link>
					<comments>http://electronicapascual.com/blog/?p=3493#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Wed, 30 Jan 2019 19:54:59 +0000</pubDate>
				<category><![CDATA[Breves]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3493</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" class="" style="-webkit-user-select: none;" src="https://c1.staticflickr.com/1/741/31748217162_b37d6c1acb_c.jpg" alt="" width="408" height="306" /></p>
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3493</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>En el banco de trabajo Reparar Liquiport 2010 CPS44</title>
		<link>http://electronicapascual.com/blog/?p=3487</link>
					<comments>http://electronicapascual.com/blog/?p=3487#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Wed, 07 Feb 2018 09:11:18 +0000</pubDate>
				<category><![CDATA[Banco de trabajo]]></category>
		<category><![CDATA[Breves]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3487</guid>

					<description><![CDATA[Reparando en nuestro laboratorio un toma muestras de la marca Hendress Hauser modelo Liquiport 2010 CPS44. Enlace de interes: Operating Instructions Liquiport 2010 CSP44 &#60; Imágenes Electrónica Pascual &#62;]]></description>
										<content:encoded><![CDATA[<div id="allsizes-photo"><img loading="lazy" src="https://c1.staticflickr.com/5/4675/40130664851_23701cc320.jpg" alt="" width="480" height="360" /></div>
<div style="text-align: justify;">Reparando en nuestro laboratorio un toma muestras de la marca <em><strong>Hendress Hauser</strong></em> modelo <em><span style="color: #000080;">Liquiport 2010 CPS44.</span></em></div>
<div style="text-align: justify;">
<p style="text-align: justify;"><img loading="lazy" src="https://c1.staticflickr.com/5/4630/40130664091_ee858452ed.jpg" alt="" width="451" height="338" /></p>
<p style="text-align: center;">
<h3 style="text-align: left;"><span style="color: #000080;">Enlace de interes:</span></h3>
<p style="text-align: left;"><em>Operating Instructions</em></p>
<div style="font-size: 22.4px; font-family: serif; left: 185.197px; top: 109.117px; transform: scale(0.875579, 1); transform-origin: 0% 0% 0px; text-align: center;" dir="ltr"><a href="https://portal.endress.com/wa001/dla/5000758/6622/000/03/KA01166CEN_0416.pdf" target="_blank">Liquiport 2010 CSP44</a></div>
<p style="text-align: left;"><a href="https://www.flickr.com/photos/22413231@N07/" target="_blank"><em><span style="color: #000080;">&lt; Imágenes Electrónica Pascual &gt;</span></em></a></p>
</div>
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3487</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>En el banco de trabajo Fluke Ti125 Camara termica</title>
		<link>http://electronicapascual.com/blog/?p=3480</link>
					<comments>http://electronicapascual.com/blog/?p=3480#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Tue, 06 Feb 2018 11:27:22 +0000</pubDate>
				<category><![CDATA[Banco de trabajo]]></category>
		<category><![CDATA[Breves]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3480</guid>

					<description><![CDATA[En uno de los bancos de trabajo de nuestro laboratorio estamos reparando una Cámara Térmica FLUKE  Ti125. Estas imágenes son de los inicios de la  reparación. Enlace de interés: Cámara termográfica Fluke Ti20 &#60; Imágenes Electrónica Pascual &#62;]]></description>
										<content:encoded><![CDATA[<div id="allsizes-photo" style="text-align: center;"><a href="https://c1.staticflickr.com/5/4710/40114507771_99da237bbc.jpg" target="_blank"><img loading="lazy" src="https://c1.staticflickr.com/5/4710/40114507771_99da237bbc.jpg" alt="" width="450" height="338" /></a></div>
<div style="text-align: justify;">En uno de los bancos de trabajo de <em>nuestro laboratorio</em> estamos reparando una <em><strong>Cámara Térmica</strong></em> <span style="color: #000080;"> <strong><em>FLUKE  Ti125</em></strong></span>.</div>
<div style="text-align: justify;">
<p style="text-align: center;"><a href="https://c1.staticflickr.com/5/4714/40114508091_2536a2748a_b.jpg" target="_blank"><img loading="lazy" src="https://c1.staticflickr.com/5/4714/40114508091_2536a2748a.jpg" alt="" width="469" height="351" /></a></p>
<p style="text-align: justify;"><em>Estas imágenes son de los inicios de la  reparación.</em></p>
<p style="text-align: justify;">Enlace de interés:</p>
<h2 style="text-align: center;"><em><a href="http://www.fluke.com/fluke/eses/termografia/fluke-ti20-%28europe-only%29.htm?pid=56181" target="_blank">Cámara termográfica Fluke Ti20</a></em></h2>
<p style="text-align: justify;">
<p style="text-align: justify;">
<p style="text-align: justify;"><a href="https://www.flickr.com/photos/22413231@N07/" target="_blank"><em><span style="color: #000080;">&lt; Imágenes Electrónica Pascual &gt;</span></em></a></p>
<p style="text-align: center;">
</div>
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3480</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>En el banco de trabajo KROHNE IFC050</title>
		<link>http://electronicapascual.com/blog/?p=3475</link>
					<comments>http://electronicapascual.com/blog/?p=3475#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Mon, 05 Feb 2018 09:48:33 +0000</pubDate>
				<category><![CDATA[Banco de trabajo]]></category>
		<category><![CDATA[Breves]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3475</guid>

					<description><![CDATA[Inauguramos una nueva sección : En el banco de trabajo. Con la imagen de los equipos en reparación o diseños que estamos haciendo en el momento de la publicación. En este momento, entre otros equipos: KROHNE IFC 050 220V ac &#60; Imágenes Electrónica Pascual &#62;]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><img loading="lazy" src="https://c1.staticflickr.com/5/4626/28313989009_e602b10b66.jpg" alt="" width="471" height="353" /></p>
<p style="text-align: justify;">Inauguramos una nueva sección : En el banco de trabajo.</p>
<p style="text-align: justify;">Con la imagen de los <em>equipos en reparación </em>o<em> diseños que estamos haciendo</em> en el momento de la publicación.</p>
<p style="text-align: justify;">En este momento, entre otros equipos:</p>
<p style="text-align: center;"><em><strong><span style="color: #000080;">KROHNE IFC 050 220V ac</span></strong></em></p>
<p style="text-align: justify;"><a href="https://www.flickr.com/photos/22413231@N07/" target="_blank"><em><span style="color: #000080;">&lt; Imágenes Electrónica Pascual &gt;</span></em></a></p>
<p style="text-align: justify;">
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3475</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reparar SIEVERS 900 TOC analycer</title>
		<link>http://electronicapascual.com/blog/?p=3452</link>
					<comments>http://electronicapascual.com/blog/?p=3452#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Mon, 05 Feb 2018 08:35:25 +0000</pubDate>
				<category><![CDATA[Mantenimiento]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3452</guid>

					<description><![CDATA[Hemos reparado en nuestro  laboratorio un equipo SIEVERS 900 fabricado por GE Analytical Instruments. Es una analizador de TOC (Total Organic Carbon Analyzer) Analizadores de Carbono Orgánico Total. Los Analizadores de Carbono Orgánico Total de la Serie Sievers™ 900 de GE Analytical Instruments incluyen Analizadores de alta sensibilidad para medir la concentración de carbono orgánico [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" class="aligncenter" src="https://c1.staticflickr.com/5/4758/25212179497_1c6a0289fc.jpg" alt="" width="467" height="350" /></p>
<p style="text-align: justify;">Hemos reparado en nuestro  laboratorio un equipo <span style="color: #000080;"><em><strong>SIEVERS 900</strong></em></span> fabricado por <a href="https://www.laboratoryequipment.com/company-profiles/ge-analytical-instruments" target="_blank"><span style="color: #000080;"><em>GE Analytical Instruments</em></span></a>.</p>
<p style="text-align: justify;">Es una analizador de <em><strong>TOC</strong></em> (<em>Total Organic Carbon Analyzer</em>) Analizadores de Carbono Orgánico Total.</p>
<div style="font-size: 13.28px; font-family: sans-serif; left: 92.88px; top: 472.97px; transform: scale(0.856279, 1); transform-origin: 0% 0% 0px; text-align: justify;" dir="ltr">Los Analizadores de Carbono Orgánico Total de la  Serie Sievers<img src="https://s.w.org/images/core/emoji/13.0.0/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> 900 de GE Analytical Instruments incluyen Analizadores de alta sensibilidad para medir la concentración de carbono orgánico total (TOC, por sus siglas en inglés de Total Organic Carbon), carbono inorgánico total (TIC, por sus siglas en inglés de Total Inorganic Carbon),y carbono total (TC, por sus siglas en inglés de Total Carbon) (TC = TOC + TIC) en muestras de agua.</div>
<p style="text-align: justify;">En su interior nos encontramos un completo laboratorio de análisis químico controlado electrónicamente.</p>
<p><img loading="lazy" src="https://c1.staticflickr.com/5/4650/25212202207_74edd341bc.jpg" alt="" width="466" height="349" /></p>
<p style="text-align: center;"><em>Imagen general de la sección de análisis químico.</em></p>
<p style="text-align: justify;"><em>El Analizador se basa en la oxidación de los componentes de carbono para formar dióxido de Carbono (CO2) mediante radiación UV y un reactivo químico oxidante(persulfato de amonio). </em></p>
<p style="text-align: justify;"><em>El dióxido de Carbono se mide utilizando una técnica de detección conductométrica sensible y selectiva por membrana, conforme a la descripción de Godec y otros. (R. Godec y otros, “Método e Instrumento Para la Determinación de Carbono Disuelto en Agua”, Patente EE.UU nº 5.132.094).</em></p>
<p style="text-align: justify;">
<p style="text-align: center;"><img loading="lazy" src="https://c1.staticflickr.com/5/4608/25212191127_f6e54702cc.jpg" alt="" width="458" height="343" /></p>
<p style="text-align: justify;"><em> Para cada medición de TOC, se determina la concentración de especies de carbono inorgánico (CO2, HCO3- y CO3-2) y, después de la oxidación de compuestos orgánicos, se mide el contenido de carbono total (TC) de la muestra.</em></p>
<p><em>La concentración de los compuestos orgánicos se calcula entonces a partir de la diferencia entre las concentraciones de TC y de carbono inorgánico total (TIC), en general, conocido simplemente como carbono inorgánico (IC, por sus siglas en inglés de Inorganic Carbon).</em></p>
<p style="text-align: center;">(TOC = TC &#8211; IC)</p>
<p style="text-align: justify;"><em>El Analizador se puede utilizar para monitorear muestras de agua con calidad de alta pureza, con un contenido de TOC menor a 0,3 partes por billón (ppb), hasta muestras de agua con un TOC de 50 partes por millón (ppm).</em></p>
<p><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4696/25212198777_34908bf706.jpg" alt="https://c1.staticflickr.com/5/4696/25212198777_34908bf706.jpg" width="446" height="334" /></p>
<p style="text-align: justify;"><em>El Analizador es fácil de operar, con un mantenimiento extremadamente bajo y no requiere ningún entrenamiento especial ni conocimientos de química. </em></p>
<p style="text-align: justify;"><em>El Analizador se calibra en fábrica y la calibración permanece estable durante aproximadamente un año.</em></p>
<p style="text-align: justify;"><em> La recalibración y validación se puede hacer fácilmente en el local del cliente.</em></p>
<div style="font-size: 10.64px; font-family: sans-serif; left: 96px; top: 956.8px; transform: scale(0.820703, 1); transform-origin: 0% 0% 0px;" dir="ltr">
<div id="allsizes-photo"><img src="https://c1.staticflickr.com/5/4710/25212193917_12aa9a77d3.jpg" alt="" /></div>
</div>
<div style="font-size: 18.64px; font-family: sans-serif; left: 96px; top: 78.88px; transform: scale(0.876225, 1); transform-origin: 0% 0% 0px;" dir="ltr"><em><br />
</em></div>
<p style="font-size: 18.64px; font-family: sans-serif; left: 96px; top: 78.88px; transform: scale(0.876225, 1); transform-origin: 0% 0% 0px;" dir="ltr"><em><span style="color: #000080;"><strong>CARACTERÍSTICAS DEL SISTEMA</strong></span></em></p>
<div style="font-size: 18.64px; font-family: sans-serif; left: 96px; top: 78.88px; transform: scale(0.876225, 1); transform-origin: 0% 0% 0px;" dir="ltr"><em><span style="color: #000080;"><strong><br />
</strong></span></em></div>
<div style="font-size: 18.64px; font-family: sans-serif; left: 96px; top: 78.88px; transform: scale(0.876225, 1); transform-origin: 0% 0% 0px;" dir="ltr">Analizador de TOC Sievers de Laboratorio</div>
<div style="font-size: 13.28px; font-family: sans-serif; left: 360.02px; top: 135.36px; transform: scale(0.863227, 1); transform-origin: 0% 0% 0px;" dir="ltr">Rango lineal: 0,03 ppb &#8211; 50 ppm TOC</div>
<div style="font-size: 13.28px; font-family: sans-serif; left: 405.57px; top: 159.357px; transform: scale(0.839394, 1); transform-origin: 0% 0% 0px;" dir="ltr">Precisión: &lt;1% de DER</div>
<div style="font-size: 13.28px; font-family: sans-serif; left: 360.139px; top: 183.354px; transform: scale(0.832563, 1); transform-origin: 0% 0% 0px;" dir="ltr">Exactitud: ±2% o ±0,5 ppb, el que sea mayor</div>
<div style="font-size: 13.28px; font-family: sans-serif; left: 360.06px; top: 207.351px; transform: scale(0.857663, 1); transform-origin: 0% 0% 0px;" dir="ltr">Tiempo de Análisis: 4 minutos</div>
<div style="font-size: 13.28px; font-family: sans-serif; left: 302.477px; top: 231.348px; transform: scale(0.82518, 1); transform-origin: 0% 0% 0px;" dir="ltr">Medida de Flujo de Muestra (nominal):                 Modo de análisis: 0,5 mL/min</div>
<p style="font-size: 13.28px; font-family: sans-serif; left: 359.993px; top: 247.35px; transform: scale(0.850735, 1); transform-origin: 0% 0% 0px;" dir="ltr">Enjuague Rápido (entre muestras): 1,0 mL/min</p>
<div style="font-size: 13.28px; font-family: sans-serif; left: 359.993px; top: 247.35px; transform: scale(0.850735, 1); transform-origin: 0% 0% 0px;" dir="ltr"><img class="decoded" src="https://c1.staticflickr.com/5/4660/25212196127_456f6f9f03.jpg" alt="https://c1.staticflickr.com/5/4660/25212196127_456f6f9f03.jpg" /></div>
<p style="font-size: 13.28px; font-family: sans-serif; left: 359.993px; top: 247.35px; transform: scale(0.850735, 1); transform-origin: 0% 0% 0px; text-align: justify;" dir="ltr">El Problema que presenta el equipo:</p>
<p style="font-size: 13.28px; left: 359.993px; top: 247.35px; transform: scale(0.850735, 1); transform-origin: 0% 0% 0px; text-align: center;" dir="ltr"><strong><span style="color: #800000;">No enciende la pantalla.</span></strong></p>
<div style="font-size: 13.28px; font-family: sans-serif; left: 359.993px; top: 247.35px; transform: scale(0.850735, 1); transform-origin: 0% 0% 0px; text-align: justify;" dir="ltr"><img class="decoded" src="https://c1.staticflickr.com/5/4716/25212188527_c5697483cc.jpg" alt="https://c1.staticflickr.com/5/4716/25212188527_c5697483cc.jpg" /></div>
<p style="text-align: justify;">En primer lugar extraemos las placas de control, que como puede verse en las imágenes están bastante sucias de polvo.</p>
<p style="text-align: justify;"><em>Por lo general el polvo no suele afectar a las placas electrónicas, pero en ocasiones puede contener partículas metálicas, o en ambientes húmedos puede volverse conductivo. </em></p>
<p style="text-align: justify;">Procedemos a limpiar las placas en un baño ultrasónico, a su revisión y al cambio de uno de los controladores.</p>
<p style="text-align: center;"><img loading="lazy" src="https://c1.staticflickr.com/5/4708/25212209757_05e81a59d8.jpg" alt="" width="451" height="338" /></p>
<p style="text-align: justify;">Imagen de la pantalla después de la reparación, que antes aparecía completamente en blanco.</p>
<p style="&lt;i"><strong><span style="color: #000080;"><span style="color: #008000;">Enlace de interés :</span></span></strong></p>
<p style="text-align: center;"><em><span style="color: #000080;"><strong>Manual de operación y mantenimiento:</strong></span></em> <a href="https://www.geinstruments.com/down-media?f_id=2004" target="_blank"><em><strong>TOC Sievers</strong></em></a></p>
<div><a href="https://www.flickr.com/photos/22413231@N07/" target="_self"><span style="color: #000080;">&lt; Imágenes Electrónica Pascual &gt;</span></a></div>
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3452</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reparar Viscosimetro Digiterm 2000</title>
		<link>http://electronicapascual.com/blog/?p=3444</link>
					<comments>http://electronicapascual.com/blog/?p=3444#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Sat, 03 Feb 2018 13:43:18 +0000</pubDate>
				<category><![CDATA[Breves]]></category>
		<category><![CDATA[Mantenimiento]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3444</guid>

					<description><![CDATA[Imágenes de la reparación en nuestro laboratorio de un viscosimetro DIGITERM 2000 Imagen de la electrónica de control y de los elementos calefactores. Presentaba un problema en el sistema de inicialización del la pantalla. &#60; Imágenes Electrónica Pascual &#62;]]></description>
										<content:encoded><![CDATA[<div style="width: 433px" class="wp-caption aligncenter"><img loading="lazy" class="decoded " title="DIGITERM 2000" src="https://c1.staticflickr.com/5/4716/28279241889_8c5bd2bf5b.jpg" alt="https://c1.staticflickr.com/5/4716/28279241889_8c5bd2bf5b.jpg" width="423" height="317" /><p class="wp-caption-text">DIGITERM 2000</p></div>
<p style="text-align: justify;">Imágenes de la reparación en nuestro laboratorio de un viscosimetro <span style="color: #000080;"><strong><em>DIGITERM 2000</em></strong></span></p>
<p style="text-align: center;"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4648/28279243789_51959e9501.jpg" alt="https://c1.staticflickr.com/5/4648/28279243789_51959e9501.jpg" width="415" height="311" /></p>
<p style="text-align: center;"><em>Imagen de la electrónica de control y de los elementos calefactores</em>.</p>
<p>Presentaba un problema en el sistema de inicialización del la pantalla.</p>
<p style="text-align: center;"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4663/28279239789_c10ce6f025.jpg" alt="https://c1.staticflickr.com/5/4663/28279239789_c10ce6f025.jpg" width="452" height="339" /></p>
<p style="text-align: center;">
<p style="text-align: justify;"><a href="https://www.flickr.com/photos/22413231@N07/"><span style="color: #000080;"><em>&lt; Imágenes Electrónica Pascual &gt;</em></span></a></p>
<p style="text-align: justify;">
<p style="text-align: justify;">
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3444</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reparar conductimetro AutoSigma 3000</title>
		<link>http://electronicapascual.com/blog/?p=3439</link>
					<comments>http://electronicapascual.com/blog/?p=3439#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Fri, 05 Jan 2018 17:12:36 +0000</pubDate>
				<category><![CDATA[Mantenimiento]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3439</guid>

					<description><![CDATA[Hemos reparado en nuestro laboratorio un conductímetro de la empresa GE Inspection Technologies modelo AutoSigma 3000. Sus principales características : 60 and 500kHz sinewave frequency 0.8 to 110% IACS, 0.45 to 64 MS/m conductivity range. 10 to 110% IACS, reading 10.0 to 110.0 resolution. Accuracy at 20°C ±0.1% at 10% IACS ±0.5% at 100% IACS [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4693/38624049695_0870ca9311.jpg" alt="https://c1.staticflickr.com/5/4693/38624049695_0870ca9311.jpg" width="296" height="319" /></p>
<p style="text-align: justify;">Hemos reparado en nuestro laboratorio un conductímetro de la empresa <strong><span style="color: #000080;">GE Inspection Technologies</span> </strong>modelo<strong> <span style="color: #000080;">AutoSigma 3000.</span></strong></p>
<p><strong> </strong></p>
<p style="text-align: justify;"><strong><em>Sus principales características :</em></strong></p>
<ul>
<li>60 and 500kHz sinewave frequency</li>
<li>0.8 to 110% IACS, 0.45 to 64 MS/m conductivity range.</li>
<li>10 to 110% IACS, reading 10.0 to 110.0 resolution.</li>
<li>Accuracy at 20°C
<ul>
<li>±0.1% at 10% IACS</li>
<li>±0.5% at 100% IACS</li>
</ul>
</li>
<li>Temperature compensation.</li>
<li>LCD with selectable backlight display.</li>
<li>High impact, splash proof, polycarbonate case.</li>
</ul>
<p>El problema que presenta este equipo : <span style="color: #ff0000;">No enciende.</span></p>
<p><span style="color: #ff0000;"><span style="color: #000000;">Procedemos a desmontar el equipo</span><br />
</span></p>
<p style="text-align: center;"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4594/39520146131_a5e8ba0ff3.jpg" alt="https://c1.staticflickr.com/5/4594/39520146131_a5e8ba0ff3.jpg" width="472" height="354" /></p>
<p style="text-align: center;"><em>Imagen del equipo una vez retirada la carcasa.</em></p>
<p style="text-align: center;"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4738/39520147801_33f5532545.jpg" alt="https://c1.staticflickr.com/5/4738/39520147801_33f5532545.jpg" width="446" height="334" /></p>
<p style="text-align: center;"><em>Imagen del equipo placa frontal y conexión de cinta flexible al teclado.</em></p>
<p style="text-align: justify;"><em>El problema se encuentra en la unidad de alimentación interna con algunos semiconductores dañados.</em></p>
<p style="text-align: justify;">Se sustituyen y se comienzan las pruebas de funcionamiento.</p>
<p style="text-align: justify;"><img loading="lazy" class="decoded" src="https://c1.staticflickr.com/5/4596/24652121977_f4230fd7dd.jpg" alt="https://c1.staticflickr.com/5/4596/24652121977_f4230fd7dd.jpg" width="316" height="236" /></p>
<p style="text-align: justify;">El equipo enciende correctamente.</p>
<p style="text-align: center;"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4731/24652121107_d6af5fc02d.jpg" alt="https://c1.staticflickr.com/5/4731/24652121107_d6af5fc02d.jpg" width="415" height="311" /></p>
<p style="text-align: center;"><em>Imagen de la sonda de medida.</em></p>
<p style="text-align: center;"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4733/38624039335_8bace84300.jpg" alt="https://c1.staticflickr.com/5/4733/38624039335_8bace84300.jpg" width="439" height="329" /></p>
<p style="text-align: center;"><em>Sondas de calibración incluidas en el equipo.</em></p>
<p style="text-align: center;">
<p style="text-align: justify;"><em>Enlace pagina del fabricante :   <a href="http://www.offshore-technology.com/contractors/instrumentation/ge-inspection/" target="_blank"> </a></em><strong><a href="http://www.offshore-technology.com/contractors/instrumentation/ge-inspection/" target="_blank"><span style="color: #000080;">GE Inspection Technologies</span></a> </strong></p>
<p style="text-align: center;">
<p style="text-align: justify;"><span style="color: #000080;"><em>&lt; Imágenes Electrónica Pascual &gt;</em></span></p>
<p style="text-align: center;">
<p style="text-align: center;"><em><br />
</em></p>
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3439</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reparar ISOTECH FAST CAL mod TECH SPEC</title>
		<link>http://electronicapascual.com/blog/?p=3420</link>
					<comments>http://electronicapascual.com/blog/?p=3420#respond</comments>
		
		<dc:creator><![CDATA[Juan]]></dc:creator>
		<pubDate>Thu, 04 Jan 2018 07:55:59 +0000</pubDate>
				<category><![CDATA[Mantenimiento]]></category>
		<guid isPermaLink="false">http://electronicapascual.com/blog/?p=3420</guid>

					<description><![CDATA[Hemos reparado en nuestro  laboratorio un equipo ISOTECH Fast Cal modelo TECH SPEC. Es un equipo para la calibración industrial de sondas de temperatura con un rango de -35 a 140 ° C. Una precisión de  ± 0.2 ° C  y estabilidad de 0.02 ° C Tiempo de calentamiento -30 a + 140 ° C [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><img class="aligncenter" src="https://c1.staticflickr.com/5/4595/38763829584_f84d52a2d5.jpg" alt="" /></p>
<p style="text-align: justify;">Hemos reparado en nuestro  laboratorio un equipo <span style="color: #000080;">ISOTECH</span> <span style="color: #000080;">Fast Cal modelo TECH SPEC.</span></p>
<p style="text-align: justify;"><span style="color: #000000;">Es un equipo para la calibración industrial de sondas de temperatura con un rango de -35 a 140 ° C.</span></p>
<p style="text-align: justify;"><span style="color: #000000;">Una precisión de  ± 0.2 ° C  y estabilidad de <span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px; background-color: #efefef;">0.02 ° C</span></span></p>
<p style="text-align: justify;"><span style="color: #000000;"><span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px; background-color: #efefef;">Tiempo de calentamiento -30 a + 140 ° C en 15 minutos.</span></span></p>
<p style="text-align: justify;"><span style="color: #000000;"><span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px; background-color: #efefef;">Tiempo de enfriamiento +140 a 0 ° C en 15 minutos.</span></span></p>
<p style="text-align: justify;"><span style="color: #000000;"><span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px; background-color: #efefef;"><span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px;">Capacidad de Calibración  <span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px;">145 mm de profundidad 8Ø, 6.5Ø, 3 x 4.5Ø</span></span></span></span></p>
<p style="text-align: justify;"><span style="color: #000000;"><span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px; background-color: #efefef;"><span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px;"><span style="color: #222222; font-family: 'Open Sans', 'Helvetica Neue', Helvetica, Helvetica, Arial, sans-serif; font-size: 14px; line-height: 18px;"><br />
</span></span></span></span></p>
<p style="text-align: center;"><span style="color: #000080;"><img loading="lazy" class="aligncenter" style="color: #000000; -webkit-user-select: none;" src="https://c1.staticflickr.com/5/4725/24605723807_5a10e4ed8c_n.jpg" alt="" width="426" height="320" /></span></p>
<p style="text-align: center;"><span style="color: #000080;"><em>En la imagen, modulo de control de temperatura,unidad de alimentación, placa de control de potencia, unidad de temperatura. </em></span></p>
<p style="text-align: justify;"><span style="color: #000080;"><span style="color: #000000;">El problema que presenta el equipo es que no varia la temperatura, quedándose a temperatura ambiente.</span></span></p>
<p style="text-align: justify;"><a href="https://c1.staticflickr.com/5/4689/38593936655_a63124327b.jpg" target="_blank"><img loading="lazy" class="decoded" src="https://c1.staticflickr.com/5/4689/38593936655_a63124327b.jpg" alt="https://c1.staticflickr.com/5/4689/38593936655_a63124327b.jpg" width="462" height="347" /></a></p>
<p style="text-align: justify;">
<p style="text-align: justify;">Extraemos la unidad de control con puente MosFet en H, es el encargado de suministrar la energía al conjunto de células Peltier.</p>
<p style="text-align: justify;">Se usa un <span style="color: #000080;"><strong>puente en H</strong></span> para poder cambiar la polaridad de la tensión suministrada al Peltier y pasar de enfriar a calentar.</p>
<p style="text-align: justify;">
<p style="text-align: justify;">La energía suministrada a las células, se regula mediante <span style="color: #000080;">PWM</span> y un control <span style="color: #000080;">PID</span> y se compara con una sonda de referencia de precisión situada en el interior de la cavidad de temperatura.</p>
<p style="text-align: justify;">
<p style="text-align: justify;"><a href="https://c1.staticflickr.com/5/4600/38763837044_35b04cbaff.jpg" target="_blank"><img loading="lazy" class="decoded" src="https://c1.staticflickr.com/5/4600/38763837044_35b04cbaff.jpg" alt="https://c1.staticflickr.com/5/4600/38763837044_35b04cbaff.jpg" width="466" height="349" /></a></p>
<p style="text-align: center;"><em>Establecemos un rango de temperatura en el limite inferior del equipo</em>.</p>
<p style="text-align: justify;">Reparada la unidad de potencia (puente en H) iniciamos las pruebas.</p>
<p style="text-align: justify;">
<p style="text-align: justify;">Como norma general, los rangos inferiores de temperatura dependen de la temperatura ambiente de la sala.</p>
<p style="text-align: justify;">Es indicado por el fabricante, para este equipo:</p>
<p style="text-align: justify;"><span style="color: #000000;">Rango de -35ºC  a  140 ° C   para una temperatura ambiente de 20ºC.</span></p>
<p style="text-align: justify;">
<p style="text-align: justify;"><em><span style="color: #000000;">Si la temperatura ambiente es superior a la indicada,<strong> no se alcanzaran</strong> los -35ºC , ya que el conjunto de enfriamiento <strong>no sera capaz</strong> de enfriarlo hasta ese rango.</span></em></p>
<p style="text-align: center;"><a href="https://c1.staticflickr.com/5/4738/25602447398_d17a513499.jpg" target="_blank"><img loading="lazy" class="decoded aligncenter" src="https://c1.staticflickr.com/5/4738/25602447398_d17a513499.jpg" alt="https://c1.staticflickr.com/5/4738/25602447398_d17a513499.jpg" width="470" height="352" /></a></p>
<p style="text-align: justify;"><span style="color: #000000;">Enlace de interés : <span style="color: #000080;"><strong><em><a href="http://www.isotech.co.uk/industrial-calibration/fast-calibrators/fastcal-industrial-temperature-calibrators" target="_blank">ISOTECH</a></em></strong></span></span></p>
<p style="text-align: justify;">
<p style="text-align: justify;"><span style="color: #000000;"><span style="color: #000080;"><strong><em><br />
</em></strong></span></span></p>
<p style="text-align: justify;">
<p style="text-align: justify;"><span style="color: #000000;"><em><span style="color: #000080;">&lt; Imágenes Electrónica Pascual &gt;</span></em><br />
</span></p>
<p style="text-align: justify;">
<p style="text-align: justify;">
<p style="text-align: justify;">
]]></content:encoded>
					
					<wfw:commentRss>http://electronicapascual.com/blog/?feed=rss2&#038;p=3420</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
