<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:blogger='http://schemas.google.com/blogger/2008' xmlns:georss='http://www.georss.org/georss' xmlns:gd="http://schemas.google.com/g/2005" xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-7270936414242968939</id><updated>2024-09-06T19:05:03.942-07:00</updated><title type='text'>Elektrotechnik von A - Z</title><subtitle type='html'>Hier findest du Alles rund ums Anklemmen - Anschliessen von E-Herd , Lampen , Steckdosen , Ventilatoren , und Schaltungen Aller Art.</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default?redirect=false'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>22</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-33947206199841729</id><published>2023-06-13T11:12:00.005-07:00</published><updated>2023-06-13T11:12:58.199-07:00</updated><title type='text'>Fachbegriffe Elektrotechnik</title><content type='html'>&lt;h2&gt;Elektrotechnik-ABC: Grundlagen und Begriffe&lt;/h2&gt;
&lt;p&gt;Hier sind einige optimierte Fachbegriffe aus der Elektrotechnik mit einfachen Erklärungen. Diese Liste wird kontinuierlich erweitert.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Sicherung:&lt;/strong&gt;&lt;br /&gt;Schutzeinrichtung zum Unterbrechen des Stromflusses bei Überlast oder Kurzschluss.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leistung:&lt;/strong&gt;&lt;br /&gt;die in einer bestimmten Zeit umgesetzte elektrische Energie.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Spannung:&lt;/strong&gt;&lt;br /&gt;elektrische Potenzialdifferenz zwischen zwei Punkten.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Strom:&lt;/strong&gt;&lt;br /&gt;elektrische Ladungsmenge, die pro Zeiteinheit durch einen Leiter fließt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Widerstand:&lt;/strong&gt;&lt;br /&gt;Maß für die Behinderung des Stromflusses in einem elektrischen Leiter.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Ohm&#39;sches Gesetz:&lt;/strong&gt;&lt;br /&gt;Beziehung zwischen Stromstärke, Spannung und Widerstand in einem elektrischen Stromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Kapazität:&lt;/strong&gt;&lt;br /&gt;Fähigkeit eines Bauelements, elektrische Ladung zu speichern.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Induktivität:&lt;/strong&gt;&lt;br /&gt;Fähigkeit eines Bauelements, elektrische Energie in magnetische Energie umzuwandeln und umgekehrt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Transformator:&lt;/strong&gt;&lt;br /&gt;elektrisches Gerät zum Umwandeln von Wechselspannungen in andere Spannungen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Generator:&lt;/strong&gt;&lt;br /&gt;Gerät zur Erzeugung von elektrischer Energie. &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Transistor:&lt;/strong&gt;&lt;br /&gt;elektronisches Bauelement zur Verstärkung und Schaltung von elektrischen Signalen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Diode:&lt;/strong&gt;&lt;br /&gt;elektronisches Bauelement, das den Strom nur in einer Richtung passieren lässt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Kondensator:&lt;/strong&gt;&lt;br /&gt;elektrisches Bauelement zur Speicherung von elektrischer Energie.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Spule:&lt;/strong&gt;&lt;br /&gt;elektrisches Bauelement zur Erzeugung eines magnetischen Feldes.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Relais:&lt;/strong&gt;&lt;br /&gt;elektromechanisches Schaltelement zur Steuerung größerer Ströme oder Spannungen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Potentiometer:&lt;/strong&gt;&lt;br /&gt;regelbarer Widerstand zur Einstellung von elektrischen Spannungen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Steckverbinder:&lt;/strong&gt;&lt;br /&gt;elektrisches Bauteil zum Verbinden von Leitungen und Geräten.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schalter:&lt;/strong&gt;&lt;br /&gt;elektrisches Bauteil zum Unterbrechen oder Herstellen des Stromflusses.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leistungsfaktor:&lt;/strong&gt;&lt;br /&gt;Verhältnis von Wirkleistung zur Scheinleistung in einem Wechselstromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Wirkleistung:&lt;/strong&gt;&lt;br /&gt;elektrische Leistung, die tatsächlich in einer Schaltung genutzt wird.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Blindleistung:&lt;/strong&gt;&lt;br /&gt;elektrische Leistung, die zwischen Spannungsquelle und Verbraucher hin und her fließt, ohne tatsächlich genutzt zu werden.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Scheinleistung:&lt;/strong&gt;&lt;br /&gt;mathematische Kombination von Wirkleistung und Blindleistung in einem Wechselstromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Drehstrom:&lt;/strong&gt;&lt;br /&gt;elektrischer Strom, bei dem drei Wechselströme mit gleicher Frequenz, aber phasenverschoben zueinander, fließen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schaltplan:&lt;/strong&gt;&lt;br /&gt;grafische Darstellung eines elektrischen Schaltkreises.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzklasse:&lt;/strong&gt;&lt;br /&gt;Klassifizierung von elektrischen Geräten nach ihrem Schutz gegen Berührungsspannung.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Erdung:&lt;/strong&gt;&lt;br /&gt;Verbindung eines leitfähigen Teils mit der Erde, um einen sicheren elektrischen Bezugspunkt herzustellen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;EMV:&lt;/strong&gt;&lt;br /&gt;Elektromagnetische Verträglichkeit - Maß für die Fähigkeit eines Geräts, störungsfrei in einer elektromagnetischen Umgebung zu arbeiten.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Frequenz:&lt;/strong&gt;&lt;br /&gt;Anzahl der Schwingungen pro Sekunde in einem Wechselstromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schwingung:&lt;/strong&gt;&lt;br /&gt;periodische Bewegung zwischen zwei Grenzpunkten.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Sicherheitstransformator:&lt;/strong&gt;&lt;br /&gt;Transformator, der die elektrische Sicherheit erhöht, indem er die Spannung herabsetzt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Photovoltaik:&lt;/strong&gt;&lt;br /&gt;direkte Umwandlung von Lichtenergie in elektrische Energie mithilfe von Solarzellen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Gleichstrom:&lt;/strong&gt;&lt;br /&gt;Strom, bei dem die Ladungsträger in eine Richtung fließen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Wechselstrom:&lt;/strong&gt;&lt;br /&gt;Strom, bei dem die Richtung der Ladungsträger periodisch wechselt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Niederspannung:&lt;/strong&gt;&lt;br /&gt;elektrische Spannung, die geringer ist als eine bestimmte festgelegte Grenze.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Hochspannung:&lt;/strong&gt;&lt;br /&gt;elektrische Spannung, die höher ist als eine bestimmte festgelegte Grenze.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzart:&lt;/strong&gt;&lt;br /&gt;Klassifizierung von elektrischen Geräten nach ihrem Schutz gegen das Eindringen von Fremdkörpern und Feuchtigkeit.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Durchgangsprüfung:&lt;/strong&gt;&lt;br /&gt;Prüfverfahren zur Überprüfung der Leitfähigkeit eines elektrischen Leiters.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Isolationsprüfung:&lt;/strong&gt;&lt;br /&gt;Prüfverfahren zur Überprüfung der Isolationsfestigkeit eines elektrischen Betriebsmittels.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;EMV-Prüfung:&lt;/strong&gt;&lt;br /&gt;Prüfverfahren zur Überprüfung der elektromagnetischen Verträglichkeit eines Geräts.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Potentialausgleich:&lt;/strong&gt;&lt;br /&gt;Verbindung von leitfähigen Teilen, um Spannungsdifferenzen auszugleichen und mögliche Gefahren zu vermeiden.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Kurzschlussschutz:&lt;/strong&gt;&lt;br /&gt;Schutzvorrichtung, die den Stromfluss bei einem Kurzschluss unterbricht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Erdungswiderstand:&lt;/strong&gt;&lt;br /&gt;Widerstand zwischen dem geerdeten Teil eines elektrischen Systems und der Erde.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Gleichrichter:&lt;/strong&gt;&lt;br /&gt;elektronisches Bauelement zur Umwandlung von Wechselstrom in Gleichstrom.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Motor:&lt;/strong&gt;&lt;br /&gt;elektrisches Gerät, das elektrische Energie in mechanische Energie umwandelt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzschalter:&lt;/strong&gt;&lt;br /&gt;Schalter, der den Stromkreis bei Überlast oder Kurzschluss unterbricht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Dämmerungsschalter:&lt;/strong&gt;&lt;br /&gt;Schalter, der bei Einbruch der Dunkelheit automatisch das Licht einschaltet.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Steckdose:&lt;/strong&gt;&lt;br /&gt;elektrische Anschlussvorrichtung zum Anschließen von Geräten an das Stromnetz.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Trennschalter:&lt;/strong&gt;&lt;br /&gt;Schalter, der einen Stromkreis sicher und dauerhaft unterbricht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Batterie:&lt;/strong&gt;&lt;br /&gt;elektrische Energiequelle, die aus mehreren Zellen besteht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzbeschaltung:&lt;/strong&gt;&lt;br /&gt;Schaltung, die zum Schutz von elektrischen Betriebsmitteln verwendet wird.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schaltschrank:&lt;/strong&gt;&lt;br /&gt;gehäuseter Bereich zur Aufnahme von elektrischen Schaltgeräten.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Sicherheitsbeleuchtung:&lt;/strong&gt;&lt;br /&gt;Beleuchtungssystem zur Sicherstellung von ausreichender Beleuchtung im Notfall.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Lichtbogen:&lt;/strong&gt;&lt;br /&gt;elektrische Entladung zwischen zwei Elektroden.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;EMF:&lt;/strong&gt;&lt;br /&gt;Elektromotorische Kraft - elektrische Spannung, die durch eine Energiequelle erzeugt wird.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leitung:&lt;/strong&gt;&lt;br /&gt;elektrischer Draht oder Kabel zur Übertragung von elektrischem Strom.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schaltgerät:&lt;/strong&gt;&lt;br /&gt;elektrisches Bauteil zur Steuerung oder Schaltung von elektrischem Strom.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schaltschütz:&lt;/strong&gt;&lt;br /&gt;elektromechanisches Schaltgerät zur Steuerung von Leistungsströmen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Netzfilter:&lt;/strong&gt;&lt;br /&gt;elektrische Schaltung zur Unterdrückung von Störungen in einem Netzwerk.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Kabelkanal:&lt;/strong&gt;&lt;br /&gt;Schutzvorrichtung zum Führen und Verbergen von Kabeln.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Blitzableiter:&lt;/strong&gt;&lt;br /&gt;Vorrichtung zum Schutz vor Blitzschäden durch Ableitung des Blitzstroms in die Erde.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Lastschalter:&lt;/strong&gt;&lt;br /&gt;Schalter zum Ein- und Ausschalten einer elektrischen Last.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leistungstransformator:&lt;/strong&gt;&lt;br /&gt;Transformator, der elektrische Energie mit minimalen Verlusten überträgt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;FI-Schalter:&lt;/strong&gt;&lt;br /&gt;Fehlerstromschutzschalter - Schutzvorrichtung zur Erkennung von Fehlerströmen und Unterbrechung des Stromkreises.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leistungsregelung:&lt;/strong&gt;&lt;br /&gt;Regelung der elektrischen Leistung in einem Stromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schaltplananalyse:&lt;/strong&gt;&lt;br /&gt;Untersuchung eines Schaltplans zur Überprüfung der Funktion und Sicherheit.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Potentialfrei:&lt;/strong&gt;&lt;br /&gt;elektrischer Kontakt, der keine Verbindung zum Erdpotenzial hat.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Verpolungsschutz:&lt;/strong&gt;&lt;br /&gt;Schutzvorrichtung, um eine falsche Polung zu verhindern.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Stromstoßschalter:&lt;/strong&gt;&lt;br /&gt;Schalter, der einen Impuls zur Änderung des Schaltzustands verwendet.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Drehschalter:&lt;/strong&gt;&lt;br /&gt;Schalter mit mehreren Positionen zur Auswahl verschiedener Schaltzustände.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schaltnetzteil:&lt;/strong&gt;&lt;br /&gt;elektronisches Netzteil, das die Eingangsspannung in eine andere Ausgangsspannung umwandelt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Frequenzumrichter:&lt;/strong&gt;&lt;br /&gt;elektronisches Gerät zur Steuerung der Drehzahl eines Motors durch Änderung der Frequenz.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Stromrichter:&lt;/strong&gt;&lt;br /&gt;elektronisches Bauteil zur Umwandlung von Wechselstrom in Gleichstrom oder umgekehrt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schwingkreis:&lt;/strong&gt;&lt;br /&gt;elektrischer Schaltkreis, der eine schwingende Spannung oder Strom erzeugt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Selektivität:&lt;/strong&gt;&lt;br /&gt;Eigenschaft eines Schutzsystems, nur den defekten Teil des Stromkreises abzuschalten.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Wattmeter:&lt;/strong&gt;&lt;br /&gt;Messgerät zur Messung der elektrischen Leistung.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Amperemeter:&lt;/strong&gt;&lt;br /&gt;Messgerät zur Messung des elektrischen Stroms.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Voltmeter:&lt;/strong&gt;&lt;br /&gt;Messgerät zur Messung der elektrischen Spannung.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Oszilloskop:&lt;/strong&gt;&lt;br /&gt;Messgerät zur Darstellung und Analyse von elektrischen Signalen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Fehlerstrom:&lt;/strong&gt;&lt;br /&gt;Strom, der aufgrund eines Fehlers in einem Stromkreis abfließt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzhaube:&lt;/strong&gt;&lt;br /&gt;Schutzvorrichtung zum Abdecken von gefährlichen Teilen eines elektrischen Geräts.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Gleichrichterschaltung:&lt;/strong&gt;&lt;br /&gt;Schaltung zur Umwandlung von Wechselstrom in Gleichstrom.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Wärmeschutzschalter:&lt;/strong&gt;&lt;br /&gt;Schalter, der bei Überhitzung den Stromkreis unterbricht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Verdrahtung:&lt;/strong&gt;&lt;br /&gt;Anordnung und Verbindung von elektrischen Leitern in einem System.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Klemme:&lt;/strong&gt;&lt;br /&gt;elektrische Verbindungsvorrichtung zum sicheren Anschließen von Leitern.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Überspannungsschutz:&lt;/strong&gt;&lt;br /&gt;Schutzvorrichtung zum Schutz vor zu hohen Spannungsspitzen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Messwandler:&lt;/strong&gt;&lt;br /&gt;elektrisches Gerät zur Messung von Strom oder Spannung in einem Stromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leiterbahn:&lt;/strong&gt;&lt;br /&gt;leitfähige Spur auf einer Leiterplatte zur elektrischen Verbindung von Komponenten.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leitungsquerschnitt:&lt;/strong&gt;&lt;br /&gt;Maß für die Querschnittsfläche eines elektrischen Leiters.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Impedanz:&lt;/strong&gt;&lt;br /&gt;Gesamtwiderstand in einem Wechselstromkreis, einschließlich Widerstand und Reaktanz.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzrelais:&lt;/strong&gt;&lt;br /&gt;elektrisches Relais zur Überwachung und Schutz eines Stromkreises.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Entladung:&lt;/strong&gt;&lt;br /&gt;Entfernung von elektrischer Ladung aus einem Bauelement oder System.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzbrücke:&lt;/strong&gt;&lt;br /&gt;elektrische Vorrichtung zum Schutz vor Überspannungen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Messgerät:&lt;/strong&gt;&lt;br /&gt;elektrisches Gerät zur Messung von Strom, Spannung oder Leistung.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Dämmerungssensor:&lt;/strong&gt;&lt;br /&gt;Sensor, der die Helligkeit erkennt und entsprechend reagiert.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Lastausgang:&lt;/strong&gt;&lt;br /&gt;Ausgang eines Geräts, der zur Versorgung von elektrischen Lasten verwendet wird.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Sicherheitsventil:&lt;/strong&gt;&lt;br /&gt;Schutzvorrichtung, die Druck in einem System begrenzt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Resonanz:&lt;/strong&gt;&lt;br /&gt;Zustand, in dem die Frequenz eines äußeren Signals mit der natürlichen Frequenz eines Systems übereinstimmt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Verbindungsdose:&lt;/strong&gt;&lt;br /&gt;elektrische Vorrichtung zum Verbinden von Leitungen in einem Stromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Überstromschutz:&lt;/strong&gt;&lt;br /&gt;Schutzvorrichtung, die den Stromfluss bei übermäßigem Strom unterbricht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Potentialfreier Kontakt:&lt;/strong&gt;&lt;br /&gt;elektrischer Kontakt, der keine elektrische Verbindung zu anderen Teilen hat.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Isolationswiderstand:&lt;/strong&gt;&lt;br /&gt;Widerstand, der die Isolationsfestigkeit zwischen elektrischen Leitern misst.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Spannungsabfall:&lt;/strong&gt;&lt;br /&gt;Reduzierung der Spannung aufgrund von Widerstand oder Impedanz in einem Stromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Messgenauigkeit:&lt;/strong&gt;&lt;br /&gt;Genauigkeit eines Messgeräts bei der Messung von elektrischen Größen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Überspannung:&lt;/strong&gt;&lt;br /&gt;vorübergehender Anstieg der Spannung über einen bestimmten Wert in einem Stromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Strombegrenzung:&lt;/strong&gt;&lt;br /&gt;Begrenzung des Stromflusses in einem Stromkreis durch spezielle Vorrichtungen oder Schaltungen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Energieeffizienz:&lt;/strong&gt;&lt;br /&gt;Maß für die Effizienz der Energieumwandlung in einem System oder Gerät.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Zeitrelais:&lt;/strong&gt;&lt;br /&gt;elektrisches Relais, das zeitverzögert reagiert.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Brandschutz:&lt;/strong&gt;&lt;br /&gt;Maßnahmen zum Schutz vor Bränden in elektrischen Systemen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leitungslänge:&lt;/strong&gt;&lt;br /&gt;Länge eines elektrischen Leiters, die den Widerstand und den Spannungsabfall beeinflusst.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Spannungsteiler:&lt;/strong&gt;&lt;br /&gt;Schaltung zur Aufteilung der elektrischen Spannung auf verschiedene Widerstände.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Signalverstärkung:&lt;/strong&gt;&lt;br /&gt;Erhöhung der Stärke eines elektrischen Signals durch Verstärkungsschaltungen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Not-Aus-Schalter:&lt;/strong&gt;&lt;br /&gt;Schalter, der den Stromkreis in Notfallsituationen sofort unterbricht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Entstörung:&lt;/strong&gt;&lt;br /&gt;Maßnahmen zur Reduzierung von Störungen und Interferenzen in elektrischen Systemen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Thermistor:&lt;/strong&gt;&lt;br /&gt;Temperaturabhängiger Widerstand zur Überwachung der Temperatur in einem Stromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Leistungsfaktor:&lt;/strong&gt;&lt;br /&gt;Verhältnis von Wirkleistung zur Scheinleistung in einem Wechselstromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Phasenverschiebung:&lt;/strong&gt;&lt;br /&gt;Zeitliche Verschiebung zwischen zwei elektrischen Signalen in einem Wechselstromkreis.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Blindleistung:&lt;/strong&gt;&lt;br /&gt;Leistung, die aufgrund von Blindströmen in einem Wechselstromkreis entsteht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Zählerschrank:&lt;/strong&gt;&lt;br /&gt;gehäuseter Bereich zur Aufnahme von Stromzählern und Sicherungen.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Transformatorkühlung:&lt;/strong&gt;&lt;br /&gt;Kühlsystem zur Abfuhr der Wärmeenergie in einem Transformator.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Kondensator:&lt;/strong&gt;&lt;br /&gt;elektrisches Bauelement zur Speicherung von elektrischer Energie.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Anlaufstrom:&lt;/strong&gt;&lt;br /&gt;Strom, der beim Starten eines Motors kurzzeitig erhöht ist.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schwingkreis:&lt;/strong&gt;&lt;br /&gt;elektrischer Schaltkreis, der eine schwingende Spannung oder Strom erzeugt.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Selektivität:&lt;/strong&gt;&lt;br /&gt;Eigenschaft eines Schutzsystems, nur den defekten Teil des Stromkreises abzuschalten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/33947206199841729/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/33947206199841729' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/33947206199841729'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/33947206199841729'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/fachbegriffe-elektrotechnik.html' title='Fachbegriffe Elektrotechnik'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-1809035726152742771</id><published>2023-06-13T11:11:00.006-07:00</published><updated>2023-06-13T11:11:49.049-07:00</updated><title type='text'>Schutzmaßnahmen</title><content type='html'>&lt;h2&gt;Schutzmaßnahmen für den Schutz von Personen und Sachwerten in der Elektrotechnik&lt;/h2&gt;
&lt;p&gt;Bei der Nutzung elektrischer Anlagen ist es von größter Bedeutung, dass weder Personen noch Tiere zu Schaden kommen und dass Sachwerte vor Gefährdungen geschützt werden. Aus diesem Grund sind spezifische Schutzmaßnahmen erforderlich, um elektrische Unfälle zu vermeiden und zu verhindern.&lt;/p&gt;
&lt;p&gt;Im Falle von Fehlern in elektrischen Anlagen oder Geräten muss unbedingt verhindert werden, dass eine gefährlich hohe Berührungsspannung aufrechterhalten bleibt. Eine Möglichkeit, dies zu erreichen, ist durch das automatische Abschalten der Anlage.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Basisschutzmaßnahmen für den sicheren Betrieb elektrischer Anlagen&lt;/h5&gt;
&lt;p&gt;Der Basisschutz gewährleistet den Schutz vor elektrischen Schlägen im Normalbetrieb, wenn keine Fehler in der elektrischen Anlage vorliegen.&lt;/p&gt;
&lt;p&gt;Der Basisschutz kann durch Basisisolierung oder Abdeckungen erreicht werden. Es ist entscheidend, dass gefährliche aktive Teile nicht berührbar sind und berührbare leitfähige Teile keinesfalls zu gefährlichen aktiven Leitern werden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Basisisolierung von aktiven Teilen&lt;/strong&gt;&lt;br /&gt;Aktive Teile müssen vollständig mit einer elektrisch und mechanisch widerstandsfähigen Isolierung umhüllt sein. Diese Isolierung darf nur durch Zerstören entfernt werden können. Oxidschichten, Faserstoffumhüllungen, Lack und Emaille-Überzüge erfüllen diese Anforderungen nicht.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Abdeckungen oder Umhüllungen&lt;/strong&gt;&lt;br /&gt;Abdeckungen oder Umhüllungen, beispielsweise von Schaltern oder Steckdosen, dienen dem Schutz vor direkter Berührung. Sie müssen mindestens der Schutzart IP 2X oder IP XXB entsprechen. Bei leicht zugänglichen Oberflächen von Abdeckungen ist eine Mindestschutzart von IP 4X oder IP XXD vorgeschrieben. Abdeckungen oder Umhüllungen müssen sicher befestigt sein und nur mit Werkzeug entfernt werden können.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;blockquote&gt;
&lt;p&gt;Der Basisschutz ist erforderlich, wenn die Betriebsspannung 25V Wechselspannung &lt;br /&gt;oder 60V Gleichspannung überschreitet und wird kategorisiert mit den Schutzklassen.&lt;/p&gt;
&lt;/blockquote&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Schutzklassen in der Elektrotechnik&lt;/h5&gt;
&lt;p&gt;In der Elektrotechnik gibt es verschiedene Schutzklassen, die den Schutz gegen elektrische Gefahren definieren.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzklasse 0:&lt;/strong&gt;&lt;br /&gt;In dieser Schutzklasse besteht neben der Basisisolierung kein weiterer Schutz gegen einen elektrischen Schlag. Eine Verbindung zum Schutzleitersystem ist nicht möglich. Der Schutz erfolgt ausschließlich durch die Umgebung des Betriebsmittels.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzklasse I:&lt;/strong&gt;&lt;br /&gt;Bei dieser Schutzklasse werden elektrische Betriebsmittel mit dem Schutzleitersystem verbunden. Dadurch wird ein zusätzlicher Schutz vor elektrischen Schlägen gewährleistet.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzklasse II:&lt;/strong&gt;&lt;br /&gt;In dieser Schutzklasse werden elektrische Betriebsmittel durch doppelte oder verstärkte Isolation geschützt. Dadurch wird ein Schutz vor elektrischen Gefahren ohne eine Verbindung zum Schutzleitersystem erreicht.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Schutzklasse III:&lt;/strong&gt;&lt;br /&gt;Bei dieser Schutzklasse werden elektrische Betriebsmittel mittels Schutzkleinspannung geschützt. Hierbei wird die Spannung auf eine sichere, niedrige Spannung reduziert, um einen Schutz vor elektrischen Gefahren zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, die geeignete Schutzklasse entsprechend den Anforderungen und Einsatzbedingungen der elektrischen Anlagen und Geräte auszuwählen, um einen angemessenen Schutz für Personen und Sachwerte zu gewährleisten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Fehlerschutz in der Elektrotechnik&lt;/h5&gt;
&lt;p&gt;Der Fehlerschutz hat zum Ziel, den Schutz vor elektrischem Schlag im Fehlerfall sicherzustellen. Sobald ein Fehler in der elektrischen Anlage auftritt, muss der Fehlerschutz aktiv werden und abschalten.&lt;/p&gt;
&lt;p&gt;In modernen Elektroinstallationen wird angestrebt, die Abschaltzeiten zu reduzieren. Dies wird durch die Verwendung von automatischen Abschalteinrichtungen im Fehlerfall erreicht.&lt;/p&gt;
&lt;p&gt;Die automatische Abschaltung erfolgt durch Überstromschutzeinrichtungen wie zum Beispiel Leitungsschutzschalter oder Fehlerstromschutzschalter (RCD).&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Es gelten bestimmte Abschaltzeiten, die eingehalten werden müssen:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Für Endstromkreise ohne Steckdosen und einem Nennstrom von ≤ 32A beträgt die Abschaltzeit ≤ 0,4 Sekunden.&lt;/li&gt;
&lt;li&gt;Für Endstromkreise ohne Steckdosen und einem Nennstrom &amp;gt; 32A beträgt die Abschaltzeit ≤ 5 Sekunden.&lt;/li&gt;
&lt;li&gt;Für Endstromkreise mit Steckdosen und einem Nennstrom von ≤ 32A beträgt die Abschaltzeit ≤ 0,4 Sekunden.&lt;/li&gt;
&lt;li&gt;Für Endstromkreise mit Steckdosen und einem Nennstrom ≤ 63A beträgt die Abschaltzeit ≤ 0,4 Sekunden.&lt;/li&gt;
&lt;li&gt;Für Endstromkreise ohne Steckdosen und einem Nennstrom &amp;gt; 63A beträgt die Abschaltzeit ≤ 5 Sekunden.&lt;/li&gt;
&lt;li&gt;Für Verteilerstromkreise (Zuleitungen) beträgt die Abschaltzeit ≤ 5 Sekunden.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Diese Abschaltzeiten gewährleisten einen effektiven Schutz vor gefährlichen Situationen im Fehlerfall. Es ist wichtig, die entsprechenden Überstromschutzeinrichtungen gemäß den vorgegebenen Abschaltzeiten korrekt auszuwählen und einzusetzen, um die Sicherheit von Personen und Sachwerten zu gewährleisten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Zusatzschutz in der Elektrotechnik&lt;/h5&gt;
&lt;p&gt;Der Zusatzschutz stellt eine zusätzliche Sicherheitsmaßnahme dar, die zum Einsatz kommt, wenn der Basisschutz oder der Fehlerschutz nicht ausreichend sind.&lt;/p&gt;
&lt;p&gt;Ein gängiger Zusatzschutzmechanismus besteht in der Installation einer Fehlerstromschutzeinrichtung, auch als Fehlerstromschutzschalter (RCD) bezeichnet. Diese Vorrichtung erkennt Abweichungen im Stromfluss und schaltet bei einem Fehler sofort ab. Ein Fehlerstromschutzschalter überwacht den elektrischen Strom in einem Stromkreis und erkennt kleinste Abweichungen, die auf einen Fehlerstrom hindeuten könnten, beispielsweise durch einen Isolationsfehler oder einen direkten Kontakt mit spannungsführenden Teilen. Sobald ein solcher Fehlerstrom erkannt wird, schaltet der RCD den Stromkreis sofort ab, um das Risiko eines elektrischen Schlags zu minimieren.&lt;/p&gt;
&lt;p&gt;Der Einsatz eines Fehlerstromschutzschalters als Zusatzschutz ist besonders wichtig in Bereichen, in denen Personen einem erhöhten Risiko ausgesetzt sind, wie beispielsweise in Badezimmern, Außenbereichen oder Baustellen. Durch den Zusatzschutz mit einem Fehlerstromschutzschalter wird die Sicherheit weiter verbessert und das Risiko von elektrischen Unfällen verringert.&lt;/p&gt;
&lt;p&gt;Es ist empfehlenswert, den Zusatzschutz in elektrischen Anlagen zu berücksichtigen, um eine umfassende Sicherheitsstrategie zu gewährleisten und mögliche Gefahren im Falle von Ausfällen des Basisschutzes oder Fehlerschutzes zu minimieren.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/1809035726152742771/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/1809035726152742771' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1809035726152742771'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1809035726152742771'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/schutzmanahmen.html' title='Schutzmaßnahmen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-1432550976127616351</id><published>2023-06-13T11:10:00.006-07:00</published><updated>2023-06-13T11:10:54.966-07:00</updated><title type='text'>IP- Schutzklassen</title><content type='html'>&lt;h2&gt;In der Elektrotechnik gibt es Schutzklassen&lt;/h2&gt;
&lt;p&gt;...die zur Kategorisierung und Kennzeichnung elektrischer Betriebsmittel hinsichtlich der Sicherheitsmaßnahmen zum Schutz vor elektrischem Schlag dienen.&lt;/p&gt;
&lt;p&gt;Es gibt insgesamt vier Schutzklassen für elektrische Betriebsmittel, wobei in der EU und anderen Industriestaaten nur die Schutzklassen eins bis drei zugelassen sind. Die Schutzklassen sind wie folgt definiert:&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schutzklasse I:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Elektrische Betriebsmittel der Schutzklasse I verfügen über einen Schutzleiteranschluss, der einen zusätzlichen Schutz vor elektrischem Schlag bietet. Sie sind gekennzeichnet durch das Symbol eines Quadrats in Kombination mit dem Buchstaben &quot;I&quot;.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schutzklasse II:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Elektrische Betriebsmittel der Schutzklasse II bieten einen verstärkten Schutz vor elektrischem Schlag, indem sie eine doppelte Isolierung oder verstärkte Isolierung verwenden. Sie benötigen keinen Schutzleiteranschluss. Sie sind gekennzeichnet durch das Symbol eines Quadrats in Kombination mit dem Buchstaben &quot;II&quot;.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;3. Schutzklasse III:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Elektrische Betriebsmittel der Schutzklasse III arbeiten mit Schutzkleinspannung (SELV - Safety Extra Low Voltage) und bieten einen zusätzlichen Schutz vor elektrischem Schlag. Sie sind gekennzeichnet durch das Symbol eines Quadrats in Kombination mit dem Buchstaben &quot;III&quot;.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schutzklasse 0:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Die Schutzklasse 0 wird nicht mehr empfohlen und ist in vielen Ländern nicht zulässig. Sie bezeichnet elektrische Betriebsmittel ohne zusätzlichen Schutz gegen elektrischen Schlag. Produkte in Schutzklasse 0 sind nicht mehr im Handel erhältlich.&lt;/p&gt;
&lt;p&gt;Die Kennzeichnung der elektrischen Betriebsmittel mit der entsprechenden Schutzklasse erfolgt durch Symbole, die auf dem Produkt oder in der technischen Dokumentation angegeben sind. Es ist wichtig, die richtige Schutzklasse entsprechend den Anforderungen und Vorschriften des jeweiligen Landes und Einsatzbereichs zu wählen, um einen sicheren Betrieb zu gewährleisten und das Risiko von elektrischem Schlag zu minimieren.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh9DmuUtD73EuQublGIKD0krQCLfb5QrjkRFAKcLPnkjxd3KxnOcNXeoyrn18JASJrB9EA88FaHoYijXs3h6kvxDnDNZdECDO68tSDfC0uGhuwZuDtmM-H1OcTtglu1JSqm2aSll8FoIgnewYK_0dRxANP8fBxSx3kt2fXTf9O1EVuL4_JGUq3P1BllTA/s600/Schutzklassen%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;400&quot; data-original-width=&quot;600&quot; height=&quot;266&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh9DmuUtD73EuQublGIKD0krQCLfb5QrjkRFAKcLPnkjxd3KxnOcNXeoyrn18JASJrB9EA88FaHoYijXs3h6kvxDnDNZdECDO68tSDfC0uGhuwZuDtmM-H1OcTtglu1JSqm2aSll8FoIgnewYK_0dRxANP8fBxSx3kt2fXTf9O1EVuL4_JGUq3P1BllTA/w400-h266/Schutzklassen%20simple%20elektrotechnik.jpg&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Schutzklasse 0&lt;/h5&gt;
&lt;p&gt;Die Schutzklasse 0 hat keine spezifische Kennzeichnung oder Symbol. Diese Schutzklasse wird nicht mehr empfohlen und ist in vielen Ländern nicht zulässig. Elektrische Betriebsmittel in Schutzklasse 0 verfügen lediglich über die Basisisolierung, bieten jedoch keinen zusätzlichen Schutz gegen elektrischen Schlag. Sie können nicht an das Schutzleitersystem angeschlossen werden und der Schutz vor elektrischem Schlag muss ausschließlich durch die Umgebung des Betriebsmittels sichergestellt werden.&lt;/p&gt;
&lt;p&gt;Aufgrund der fehlenden Schutzmaßnahmen ist die Verwendung von Betriebsmitteln in Schutzklasse 0 nicht empfehlenswert, da sie ein erhöhtes Risiko für elektrischen Schlag darstellen können. Es wird dringend empfohlen, Betriebsmittel mit einer höheren Schutzklasse zu verwenden, wie Schutzklasse I, II oder III, um die Sicherheit zu gewährleisten und die Anforderungen der geltenden Vorschriften zu erfüllen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Schutzklasse I&lt;/h5&gt;
&lt;p&gt;Bei der Schutzklasse I werden elektrische Betriebsmittel mit dem Schutzleitersystem verbunden. Diese Schutzklasse bietet einen zusätzlichen Schutz gegen elektrischen Schlag, indem ein Schutzleiteranschluss vorhanden ist. Der Schutzleiter dient dazu, im Falle eines Isolationsfehlers den Strom sicher abzuleiten und somit das Risiko eines elektrischen Schlages zu verringern.&lt;/p&gt;
&lt;table&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 150px;&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgwhZwfuSvfwralfY_CCLT5KSyozT1j8ql7WcuaeMhuLX4r1At9adtwv3Hljk_iBEDr0Spsh-UfzLo3FO9LQ9ylK_lh_IJskhyk6TtXT4s9KNs8-by6dytUaRk4g-2utDVuIuVLfJyklHENJZ_k6XezG5vOlZ-zkjvoNPMNQcAtjHkBPUMm-p0uHjKzwQ/s100/Schutzklasse%201%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;100&quot; data-original-width=&quot;100&quot; height=&quot;100&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgwhZwfuSvfwralfY_CCLT5KSyozT1j8ql7WcuaeMhuLX4r1At9adtwv3Hljk_iBEDr0Spsh-UfzLo3FO9LQ9ylK_lh_IJskhyk6TtXT4s9KNs8-by6dytUaRk4g-2utDVuIuVLfJyklHENJZ_k6XezG5vOlZ-zkjvoNPMNQcAtjHkBPUMm-p0uHjKzwQ/s1600/Schutzklasse%201%20simple%20elektrotechnik.jpg&quot; width=&quot;100&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;Bei elektrischen Betriebsmitteln der Schutzklasse I ist die Basisisolierung vorhanden, jedoch wird zusätzlich der Schutzleiter verwendet, um einen zuverlässigen Schutz gegen elektrischen Schlag zu gewährleisten. Der Schutzleiter ist in der Regel mit dem metallischen Gehäuse des Betriebsmittels verbunden und wird mit einer Erdungsanlage oder einem geerdeten Stromkreis verbunden.&lt;/p&gt;
&lt;p&gt;Um elektrische Betriebsmittel der Schutzklasse I zu kennzeichnen, wird das Symbol eines Quadrats in Kombination mit dem Buchstaben &quot;I&quot; verwendet. Diese Kennzeichnung kann auf dem Produkt selbst oder in der technischen Dokumentation zu finden sein.&lt;/p&gt;
&lt;p&gt;Die Verwendung von Betriebsmitteln in Schutzklasse I bietet einen erhöhten Schutz vor elektrischem Schlag und ist besonders wichtig in Bereichen, in denen ein erhöhtes Risiko besteht, wie beispielsweise in der Industrie oder im medizinischen Bereich. Es ist jedoch zu beachten, dass eine fachgerechte Installation und regelmäßige Überprüfung des Schutzleitersystems erforderlich sind, um die Wirksamkeit und Sicherheit zu gewährleisten.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Schutzklasse II&lt;/h5&gt;
&lt;p&gt;Bei der Schutzklasse II werden elektrische Betriebsmittel durch doppelte oder verstärkte Isolation geschützt. Im Gegensatz zur Schutzklasse I wird in Schutzklasse II kein Schutzleitersystem verwendet.&lt;/p&gt;
&lt;table&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 150px;&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjP6_8iOyEuSt7hoLkKCjWvcL-E8rFz9G_Aka6JHlZvAFFO3ivJM7yhHXPiUYkCJUAjzHDmaaoYwAv-MV_qOuJ5W9iXu0hlaQQthmKTIp74ZO5QjqXCOwlWdMDAtJnJZ84vxbgUHhk0iCE1A4j40LltM0kN227F_RKZECFdDkoSCYJr53gDMIT4qQFClQ/s100/Schutzklasse%202%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;100&quot; data-original-width=&quot;100&quot; height=&quot;100&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjP6_8iOyEuSt7hoLkKCjWvcL-E8rFz9G_Aka6JHlZvAFFO3ivJM7yhHXPiUYkCJUAjzHDmaaoYwAv-MV_qOuJ5W9iXu0hlaQQthmKTIp74ZO5QjqXCOwlWdMDAtJnJZ84vxbgUHhk0iCE1A4j40LltM0kN227F_RKZECFdDkoSCYJr53gDMIT4qQFClQ/s1600/Schutzklasse%202%20simple%20elektrotechnik.jpg&quot; width=&quot;100&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;Elektrische Betriebsmittel der Schutzklasse II bieten einen erhöhten Schutz vor elektrischem Schlag, indem sie eine zusätzliche Sicherheitsschicht in Form einer doppelten Isolierung oder einer verstärkten Isolierung besitzen. Diese Isolierung ist so ausgelegt, dass sie den Schutz gegen gefährliche Spannungen auch im Falle eines Isolationsfehlers bietet.&lt;/p&gt;
&lt;p&gt;Die doppelte Isolierung besteht aus zwei unabhängigen Isolationsschichten, die elektrisch voneinander getrennt sind und eine zusätzliche Barriere gegen den Durchtritt von Strom bilden. Die verstärkte Isolierung hingegen verwendet eine einzelne Isolationsschicht, die besonders robust und widerstandsfähig ist, um einen sicheren Schutz zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Um elektrische Betriebsmittel der Schutzklasse II zu kennzeichnen, wird das Symbol eines Quadrats in Kombination mit dem Buchstaben &quot;II&quot; verwendet. Diese Kennzeichnung kann auf dem Produkt selbst oder in der technischen Dokumentation angegeben sein.&lt;/p&gt;
&lt;p&gt;Die Verwendung von Betriebsmitteln in Schutzklasse II ist besonders geeignet für Anwendungen, bei denen kein Schutzleitersystem verfügbar oder nicht erforderlich ist, wie zum Beispiel bei bestimmten Elektrogeräten, Lampen oder kleinen Haushaltsgeräten. Durch die doppelte oder verstärkte Isolierung bieten sie einen erhöhten Schutz vor elektrischem Schlag und tragen zur Sicherheit des Benutzers bei.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Schutzklasse III&lt;/h5&gt;
&lt;p&gt;Bei der Schutzklasse III werden elektrische Betriebsmittel mittels Schutzkleinspannung geschützt. Diese Schutzklasse stellt den höchsten Schutz vor elektrischem Schlag bereit.&lt;/p&gt;
&lt;table&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 150px;&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg8pxdDfTCr5rIKxlXdp_T9OrzZHOtr587FPfLo4RqdRt-8nSkjxrntbkb1bLli1dhi7yp3dvJ43Z5OKWhqdGesyEIlmG58rjV3SZg21VPo78l1QL48xztu7ESYgDcNstMvblpi98hW7V_JoEbHAp2GONPRBYST29Bhcm4c_nklyOxklsUeXq5GzGO2rQ/s100/Schutzklasse%203%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;100&quot; data-original-width=&quot;100&quot; height=&quot;100&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg8pxdDfTCr5rIKxlXdp_T9OrzZHOtr587FPfLo4RqdRt-8nSkjxrntbkb1bLli1dhi7yp3dvJ43Z5OKWhqdGesyEIlmG58rjV3SZg21VPo78l1QL48xztu7ESYgDcNstMvblpi98hW7V_JoEbHAp2GONPRBYST29Bhcm4c_nklyOxklsUeXq5GzGO2rQ/s1600/Schutzklasse%203%20simple%20elektrotechnik.jpg&quot; width=&quot;100&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;Bei Betriebsmitteln der Schutzklasse III wird die Schutzmaßnahme durch eine sichere Trennung von der Netzspannung erreicht. Anstelle der üblichen Netzspannung wird eine besonders niedrige Schutzkleinspannung verwendet, die als ungefährlich für den menschlichen Körper gilt. Diese Schutzkleinspannung beträgt in der Regel nicht mehr als 50 Volt Wechselspannung oder 120 Volt Gleichspannung.&lt;/p&gt;
&lt;p&gt;Um elektrische Betriebsmittel der Schutzklasse III zu kennzeichnen, wird das Symbol eines Quadrats in Kombination mit dem Buchstaben &quot;III&quot; verwendet. Diese Kennzeichnung kann auf dem Produkt selbst oder in der technischen Dokumentation zu finden sein.&lt;/p&gt;
&lt;p&gt;Die Verwendung von Betriebsmitteln in Schutzklasse III ist insbesondere in Bereichen erforderlich, in denen ein besonders hoher Schutz vor elektrischem Schlag erforderlich ist, wie zum Beispiel in medizinischen Einrichtungen oder bei bestimmten Arten von Mess- und Steuerungssystemen. Durch die Verwendung von Schutzkleinspannung wird das Risiko eines gefährlichen Stromschlags erheblich reduziert.&lt;/p&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass Betriebsmittel der Schutzklasse III nur mit entsprechenden Niederspannungssystemen betrieben werden dürfen und dass die Installation und Wartung gemäß den geltenden Vorschriften und Normen erfolgen muss, um die Sicherheit zu gewährleisten.&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Die Schutzklassen dienen dazu, direktes und indirektes Berühren von betriebsmäßig unter Spannung stehenden Teilen zu vermeiden und somit das Risiko eines elektrischen Schlages zu reduzieren.&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Beim direkten Berühren kommt der menschliche Körper direkt mit aktiven, unter Spannung stehenden Teilen in Kontakt. Um direktes Berühren zu verhindern, werden diese spannungsführenden Teile mit Isolierungen oder Abdeckungen versehen, um eine sichere Trennung zum menschlichen Körper zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Beim indirekten Berühren tritt hingegen Spannung an Teilen auf, die normalerweise nicht unter Spannung stehen. Dies kann durch einen Isolationsfehler oder Körperschluss verursacht werden, bei dem spannungsführende Teile mit nicht spannungsführenden Teilen in Kontakt kommen, beispielsweise das Gehäuse einer elektrischen Maschine. Um das Risiko des indirekten Berührens zu reduzieren, werden zusätzliche Schutzmaßnahmen ergriffen, wie z.B. die Verwendung von Schutzerdung, doppelter oder verstärkter Isolation oder Schutzkleinspannung in den entsprechenden Schutzklassen.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, dass elektrische Betriebsmittel entsprechend ihrer Schutzklasse ausgelegt, installiert und gewartet werden, um sowohl das direkte als auch das indirekte Berühren zu verhindern und somit die Sicherheit der Benutzer zu gewährleisten. Die Einhaltung der geltenden Vorschriften und Normen ist hierbei entscheidend.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/1432550976127616351/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/1432550976127616351' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1432550976127616351'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1432550976127616351'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/ip-schutzklassen.html' title='IP- Schutzklassen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh9DmuUtD73EuQublGIKD0krQCLfb5QrjkRFAKcLPnkjxd3KxnOcNXeoyrn18JASJrB9EA88FaHoYijXs3h6kvxDnDNZdECDO68tSDfC0uGhuwZuDtmM-H1OcTtglu1JSqm2aSll8FoIgnewYK_0dRxANP8fBxSx3kt2fXTf9O1EVuL4_JGUq3P1BllTA/s72-w400-h266-c/Schutzklassen%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-7265050939623904500</id><published>2023-06-13T11:08:00.007-07:00</published><updated>2023-06-13T11:08:49.317-07:00</updated><title type='text'>IP Schutzart</title><content type='html'>&lt;h2&gt;Die IP-Schutzart (International Protection) definiert den Schutzgrad&lt;/h2&gt;
&lt;p&gt;von elektrischen Betriebsmitteln und Verbrauchern gegen das Eindringen von festen und flüssigen Fremdkörpern. Sie gibt Auskunft darüber, wie gut das Gerät gegen das Eindringen von Fremdkörpern und Wasser geschützt ist. Die IP-Schutzart wird durch die Buchstaben &quot;IP&quot; gefolgt von zwei Kennziffern angegeben, z. B. IP23CS.&lt;/p&gt;
&lt;p&gt;Die erste Kennziffer der IP-Schutzart beschreibt den Schutz gegen das Eindringen von Festkörpern und den Berührungsschutz. Sie bewertet den Schutz vor Fremdkörpern wie Staub, Schmutz oder Berührungen durch Körperteile. Die Kennziffern reichen von 0 bis 6, wobei höhere Zahlen einen besseren Schutz bedeuten.&lt;/p&gt;
&lt;p&gt;Die zweite Kennziffer der IP-Schutzart bezieht sich auf den Schutz gegen das Eindringen von Wasser. Sie bewertet den Schutzgrad gegen das Eindringen von Wasser in verschiedenen Formen, wie z. B. Tropfwasser, Spritzwasser oder sogar bei zeitweisem Untertauchen. Die Kennziffern reichen von 0 bis 8, wobei höhere Zahlen einen besseren Schutz bedeuten.&lt;/p&gt;
&lt;p&gt;Zusätzlich zu den Buchstaben und Kennziffern können weitere Buchstaben den IP-Code ergänzen und spezifische Informationen liefern. Beispielsweise kann der IP-Code IP68 eine zusätzliche Angabe über den zulässigen Druck bei Tauchbetrieb enthalten, wie z. B. 3 bar.&lt;/p&gt;
&lt;p&gt;In Feuchträumen und im Freien gelten bestimmte Anforderungen an die Schutzart, um einen ausreichenden Schutz vor Feuchtigkeit und Wasser zu gewährleisten. Elektrische Betriebsmittel in Feuchträumen müssen mindestens tropfwassergeschützt sein (IPX1), während ungeschützte Anlagen im Freien mindestens der Schutzart IPX3 entsprechen müssen.&lt;/p&gt;
&lt;p&gt;Die Wahl der richtigen IP-Schutzart ist wichtig, um sicherzustellen, dass elektrische Geräte unter den gegebenen Bedingungen zuverlässig funktionieren und vor Schäden durch Wasser, Staub oder äußere Einflüsse geschützt sind. Die korrekte IP-Schutzart hängt vom Verwendungszweck, der Umgebung und den spezifischen Anforderungen des Geräts ab.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEglYftw7dYrs2nmFKNyfVVvsTfcHm7fZU_1rkERyo0DIBNYzUVmOT3xIgKIOOSuECo11teY1hLQ2QvhV5ZwqwIAJ8OlTW9sifcOyrdO7OV9bkBra9vL9UeRu3g93ilRGyqmvGs2UemNFAQrTMijnEQsPVigGAu86POohBmN-mGGpBxcchPcvnFk3ognzA/s600/ip%20schutzart%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;400&quot; data-original-width=&quot;600&quot; height=&quot;213&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEglYftw7dYrs2nmFKNyfVVvsTfcHm7fZU_1rkERyo0DIBNYzUVmOT3xIgKIOOSuECo11teY1hLQ2QvhV5ZwqwIAJ8OlTW9sifcOyrdO7OV9bkBra9vL9UeRu3g93ilRGyqmvGs2UemNFAQrTMijnEQsPVigGAu86POohBmN-mGGpBxcchPcvnFk3ognzA/s320/ip%20schutzart%20simple%20elektrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;IP Code - IP Schutzklasse Übersichtstabelle&lt;/h5&gt;
&lt;table border=&quot;1&quot; cellpadding=&quot;2&quot; style=&quot;border: 1px solid rgb(122, 117, 117); box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr style=&quot;background-color: #ffff99;&quot;&gt;
&lt;td style=&quot;width: 80px;&quot;&gt;1. Kennziffer&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutzgrad: Berührungs und Fremdkörperschutz&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;2. Kennziffer&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutzgrad: Wasserschutz&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;0&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Kein besonderer Schutz&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;0&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Kein besonderer Schutz&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;1&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Eindringen fester Fremdkörper mit einem Durchmesser ≥ 50mm&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;1&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen senkrecht tropfendes Wasser&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;2&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Eindringen fester Fremdkörper mit einem Durchmesser ≥ 12,5mm&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;2&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen senkrecht tropfendes Wasser, Betriebsmittel bis 15° geneigt&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;3&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Eindringen fester Fremdkörper mit einem Durchmesser ≥ 2,5mm&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;3&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Sprühwasser (Regen) bis zu einem Winkel von 60° zur Senkrechten&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;4&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Eindringen fester Fremdkörper mit einem Durchmesser ≥ 1mm&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;4&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Spritzwasser aus allen Richtungen&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;5&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Staubablagerung (staubgeschützt) Vollständiger Berührungsschutz&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;5&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Strahlwasser aus allen Richtungen&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;6&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Eindringen von Staub (staubdicht) Vollständiger Berührungsschutz&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;6&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen starken Wasserstrahl oder schwere See aus allen Richtungen&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #ffff99;&quot;&gt;Wird neben den Buchstaben IP nur eine Kennziffer für den Schutzgrad benötigt, so ist anstelle der fehlenden Kennziffer ein X zu setzen z.B. IP X4 oder IP 3X&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;7&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Wasser bei Eintauchen des Betriebsmittels unter Druck- Zeitbedingungen&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td colspan=&quot;2&quot; rowspan=&quot;2&quot; style=&quot;background-color: #ffff99;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;3. Stelle z.B. IP 23C&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;A&amp;nbsp;&amp;nbsp; Schutz gegen Zugang mit dem Handrücken&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;B&amp;nbsp;&amp;nbsp; Schutz gegen Zugang mit dem Finger&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;C&amp;nbsp;&amp;nbsp; Geschützt gegen Zugang mit Werkzeug&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;D&amp;nbsp;&amp;nbsp; Geschützt gegen Zugang mit Draht&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;4. Stelle z.B. IP 23CS&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;H&amp;nbsp;&amp;nbsp; Betriebsmittel für Hochspannung&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;M&amp;nbsp;&amp;nbsp; Geprüft auf Wassereintritt bei laufender Maschine&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;S&amp;nbsp;&amp;nbsp; Geprüft auf Wassereintritt bei stehender Maschine&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;W&amp;nbsp; Geeignet bei festgelegten Witterungsbedingungen&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;8&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Schutz gegen Wasser bei dauerndem Untertauchen des Betriebsmittels&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center; vertical-align: middle; width: 80px;&quot;&gt;9&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;Geschützt gegen Hochdruck und hohe Strahlwasser Temperaturen&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Gängige Schutzarten:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Für Lampen gibt es verschiedene Schutzarten, die je nach Einsatzort und Anforderungen variieren. Hier sind einige typische Schutzarten für Lampen:&lt;/p&gt;
&lt;p&gt;1. IP20: Schutz vor dem Eindringen fester Fremdkörper mit einem Durchmesser von mehr als 12,5 mm und kein Schutz gegen das Eindringen von Wasser.&lt;/p&gt;
&lt;p&gt;2. IP44: Schutz vor dem Eindringen fester Fremdkörper mit einem Durchmesser von mehr als 1 mm und Schutz gegen Spritzwasser aus beliebiger Richtung.&lt;/p&gt;
&lt;p&gt;3. IP65: Schutz vor dem Eindringen von Staub und Schutz gegen Strahlwasser aus beliebiger Richtung.&lt;/p&gt;
&lt;p&gt;4. IP67: Vollständiger Schutz gegen Staub und Schutz gegen zeitweiliges Untertauchen in Wasser.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Für Steckdosen und Schalter gelten ebenfalls unterschiedliche Schutzarten, abhängig vom Einsatzort und den spezifischen Anforderungen. Hier sind einige typische Schutzarten für Steckdosen und Schalter:&lt;/p&gt;
&lt;p&gt;1. IP64: Schutz vor dem Eindringen von Staub und Spritzwasser aus beliebiger Richtung.&lt;/p&gt;
&lt;p&gt;2. IP65: Schutz vor dem Eindringen von Staub und Strahlwasser aus beliebiger Richtung.&lt;/p&gt;
&lt;p&gt;3. IP66: Vollständiger Schutz gegen Staub und starkes Strahlwasser aus beliebiger Richtung.&lt;/p&gt;
&lt;p&gt;4. IP67: Vollständiger Schutz gegen Staub und Schutz gegen zeitweiliges Untertauchen in Wasser.&lt;/p&gt;
&lt;p&gt;5. IP68: Vollständiger Schutz gegen Staub und Schutz gegen dauerhaftes Untertauchen in Wasser, zusätzlich mit Angabe des zulässigen Drucks (z. B. IP68, 3 bar).&lt;/p&gt;
&lt;p&gt;Die genauen Schutzarten können je nach Hersteller und spezifischem Produkt variieren. Es ist wichtig, die spezifischen Anforderungen des Einsatzorts zu berücksichtigen und entsprechend die passende Schutzart für Lampen, Steckdosen und Schalter auszuwählen, um einen sicheren Betrieb zu gewährleisten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Hier ein paar Beispiele des IP-Schutzes:&lt;/b&gt;&lt;/p&gt;
&lt;table border=&quot;1&quot; style=&quot;box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP20&lt;/td&gt;
&lt;td&gt;Kein Schutz gegen eindringendes Wasser, Schutz gegen Fremdkörper &amp;gt;12,5mm&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP22&lt;/td&gt;
&lt;td&gt;IP22 steht für eingeschränkter Schutz gegenüber Feuchtigkeit, Schutz gegen Fremdkörper &amp;gt;12,5mm&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP23&lt;/td&gt;
&lt;td&gt;IP23 steht für Schutz gegen Sprühwasser&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP44&lt;/td&gt;
&lt;td&gt;IP44 steht für Schutz gegen Spritzwasser und feste Objekte &amp;gt;1mm.&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP65&lt;/td&gt;
&lt;td&gt;IP65 steht für Staubdicht und Schutz gegen Strahlwasser&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP66&lt;/td&gt;
&lt;td&gt;IP66 steht für Wasserdicht,&amp;nbsp; geschützt gegen schweres Strahlwasser&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP67&lt;/td&gt;
&lt;td&gt;IP67 bedeutet, dass etwas gegen Staub geschützt ist, gegen Berührung und vor Untertauchen.&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;IP68&amp;nbsp;&lt;/td&gt;
&lt;td&gt;IP68 steht für Schutz gegen Staub, Berührung und dauerhaftes Untertauchen.&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/7265050939623904500/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/7265050939623904500' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/7265050939623904500'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/7265050939623904500'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/ip-schutzart.html' title='IP Schutzart'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEglYftw7dYrs2nmFKNyfVVvsTfcHm7fZU_1rkERyo0DIBNYzUVmOT3xIgKIOOSuECo11teY1hLQ2QvhV5ZwqwIAJ8OlTW9sifcOyrdO7OV9bkBra9vL9UeRu3g93ilRGyqmvGs2UemNFAQrTMijnEQsPVigGAu86POohBmN-mGGpBxcchPcvnFk3ognzA/s72-c/ip%20schutzart%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-5834495926235627888</id><published>2023-06-13T11:06:00.002-07:00</published><updated>2023-06-13T11:06:23.140-07:00</updated><title type='text'>Installations - Drähte - Farben und ihre Bedeutung</title><content type='html'>&lt;h2&gt;Installationsdrähte in der Elektrotechnik: Funktionen, Eigenschaften und Normen&lt;/h2&gt;
&lt;p&gt;Die Welt der Elektrotechnik ist geprägt von einer Vielzahl an Drähten mit unterschiedlichen Farben und spezifischen Eigenschaften. Installationsdrähte spielen dabei eine entscheidende Rolle, da sie elektrische Energie vom Erzeuger zum Verbraucher transportieren. Zusätzlich dienen sie der Übertragung von Signalen zwischen Messeinrichtungen, Steuereinrichtungen und Regeleinrichtungen.&lt;/p&gt;
&lt;p&gt;Es ist von großer Bedeutung, dass die in elektrischen Anlagen verlegten isolierten Leitungen den geltenden Normen entsprechen. Die Hersteller sind verpflichtet, ihre Drähte normgerecht zu kennzeichnen, um die Einhaltung der Vorschriften zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Die Kennzeichnung der Installationsdrähte ermöglicht es Fachkräften, die verschiedenen Drähte einfach zu identifizieren und korrekt zu verlegen. Die Farbcodierung spielt hierbei eine wichtige Rolle, da sie Informationen über die Funktionen und Anwendungsbereiche der Drähte liefert. Zum Beispiel können schwarze Drähte für den Stromtransport verwendet werden, während rote Drähte häufig für Signale oder Alarme eingesetzt werden.&lt;/p&gt;
&lt;p&gt;Neben der Farbcodierung sollten Installationsdrähte auch bestimmte elektrische Eigenschaften aufweisen, um den reibungslosen Betrieb der elektrischen Anlage zu gewährleisten. Dazu gehören beispielsweise die Nennspannung, der Querschnitt und der Isolationswerkstoff.&lt;/p&gt;
&lt;p&gt;Um sicherzustellen, dass die Installationsdrähte den Anforderungen entsprechen, sollten Fachleute bei der Auswahl auf normgerechte Zertifizierungen und Kennzeichnungen achten. Diese Zertifizierungen bestätigen, dass die Drähte bestimmte Qualitätsstandards erfüllen und den geltenden Sicherheitsvorschriften entsprechen.&lt;/p&gt;
&lt;p&gt;Insgesamt spielen Installationsdrähte eine fundamentale Rolle in elektrischen Anlagen und ermöglichen den sicheren und effizienten Transport von elektrischer Energie sowie die zuverlässige Übertragung von Signalen. Indem sie den Normen und Vorschriften entsprechen, tragen sie zur Gewährleistung einer sicheren und zuverlässigen elektrischen Infrastruktur bei.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSTP1Zuu9Nj8gDmLR7vinHHXN60NMEu5HfiG-3ET2ARYNh3QyUul0HEMH23D9_ZOb59ask9bwbq0qx2TyNlsxQUotWXmzgR5MIwzRPyqPBmIckMYOCDtTIpXlDy2eS-Y0AiYnQVODCPm8WIiNm7FFJjb1q9alkD6sHR_RdqJL9dGIf-ZOAXMSGVwgH7g/s423/installations_draht_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;283&quot; data-original-width=&quot;423&quot; height=&quot;214&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSTP1Zuu9Nj8gDmLR7vinHHXN60NMEu5HfiG-3ET2ARYNh3QyUul0HEMH23D9_ZOb59ask9bwbq0qx2TyNlsxQUotWXmzgR5MIwzRPyqPBmIckMYOCDtTIpXlDy2eS-Y0AiYnQVODCPm8WIiNm7FFJjb1q9alkD6sHR_RdqJL9dGIf-ZOAXMSGVwgH7g/s320/installations_draht_simple_elektrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Farben und Ihre Bedeutung:&lt;/h5&gt;
&lt;table border=&quot;1&quot; style=&quot;box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;H07V-K 1,5mm² &lt;span class=&quot;style49&quot;&gt;Blau&lt;/span&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;muss als Neutralleiter verwendet werden&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;H07V-K 1,5mm² &lt;span class=&quot;style50&quot;&gt;Schwarz&lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;kann als Außenleiter oder Lampendraht verwendet werden&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;H07V-K 1,5mm² &lt;span class=&quot;style12&quot;&gt;Braun&lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;kann als Außenleiter , Lampendraht oder Tasterdraht verwendet werden&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;H07V-K 1,5mm² &lt;span class=&quot;style51&quot;&gt;Gelb&lt;/span&gt;-&lt;span class=&quot;style52&quot;&gt;Grün &amp;nbsp; &amp;nbsp;&lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;muss als Schutzleiter verwendet werden (es ist verboten diesen Draht als Außenleiter zu verwenden)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;H07V-K 1,5mm² &lt;span class=&quot;style53&quot;&gt;Orange&lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;kann als Außenleiter , Lampendraht oder Tasterdraht verwendet werden&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;H07V-K 1,5mm² &lt;span class=&quot;style54&quot;&gt;Violett&lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;kann als Außenleiter , Lampendraht oder Tasterdraht verwendet werden&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Hinweis zur Farbcodierung von Installationsdrähten:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Es ist wichtig anzumerken, dass die Farbcodierung von Installationsdrähten in der Elektrotechnik bestimmten Normen und Standards entspricht. Allerdings kann es in Einzelfällen vorkommen, dass Elektriker von diesen Vorgaben abweichen, insbesondere bei älteren Elektroinstallationen.&lt;/p&gt;
&lt;p&gt;Falls Ihre Elektro-Installation älter ist und Sie unsicher sind, ob die Farbcodierung der Installationsdrähte den aktuellen Standards entspricht, empfehlen wir Ihnen, einen qualifizierten Elektriker hinzuzuziehen. Ein Fachmann kann die Verkabelung überprüfen und feststellen, ob sie den aktuellen Vorschriften entspricht.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, dass die Elektroinstallation den Sicherheitsstandards entspricht, um Gefahren wie Kurzschlüsse, Überlastungen oder elektrische Schläge zu vermeiden. Ein Elektriker kann Ihnen dabei helfen, eventuelle Mängel zu identifizieren und entsprechende Maßnahmen zu ergreifen, um Ihre elektrische Anlage auf den aktuellen Stand zu bringen.&lt;/p&gt;
&lt;p&gt;Wir empfehlen Ihnen dringend, bei jeglichen Zweifeln oder Bedenken bezüglich Ihrer Elektroinstallation einen Fachmann zu konsultieren. Ihre Sicherheit und die ordnungsgemäße Funktion Ihrer elektrischen Anlage sollten stets oberste Priorität haben.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Falls Ihre Elektro-Installation schon etwas älter ist könnte es sein dass bei Ihnen noch die Alten Farben verwendet wurden!&lt;/b&gt;&lt;/p&gt;
&lt;table border=&quot;1&quot; cellpadding=&quot;0&quot; style=&quot;box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;&lt;span class=&quot;style49&quot;&gt;Blau&lt;/span&gt; &lt;span lang=&quot;de-at&quot;&gt;&amp;nbsp; &amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Außenleiter , Lampendraht oder Tasterdraht verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;&lt;span class=&quot;style50&quot;&gt;Schwarz&lt;/span&gt;&lt;span lang=&quot;de-at&quot;&gt; &amp;nbsp; &lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Außenleiter , Lampendraht oder Tasterdraht verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;&lt;span class=&quot;style12&quot;&gt;Braun&lt;/span&gt; &lt;span lang=&quot;de-at&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Außenleiter , Lampendraht oder Tasterdraht verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;Grün &lt;span lang=&quot;de-at&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Außenleiter , Lampendraht oder Tasterdraht verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;&lt;span class=&quot;style53&quot;&gt;Orange&lt;/span&gt; &lt;span lang=&quot;de-at&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Außenleiter , Lampendraht oder Tasterdraht verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;V&lt;span class=&quot;style54&quot;&gt;iolett&lt;/span&gt; &lt;span lang=&quot;de-at&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Außenleiter , Lampendraht oder Tasterdraht verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;&lt;span class=&quot;style51&quot;&gt;Gelb&lt;/span&gt; &lt;span lang=&quot;de-at&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Außenleiter , Lampendraht oder Tasterdraht verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99;&quot;&gt;&lt;b&gt;&lt;span class=&quot;style55&quot;&gt;Grau&lt;/span&gt; &lt;span lang=&quot;de-at&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;wurde als Neutralleiter verwendet&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;Schutzleiter gab es damals noch nicht&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Bei älteren Elektroinstallationen wurden teilweise unterschiedliche Farbcodierungen für spezifische Zwecke verwendet. Hier sind einige Beispiele:&lt;/p&gt;
&lt;p&gt;Außenleiter: In einigen Fällen wurde der Außenleiter, auch bekannt als Phase oder L-Leiter, mit der Farbe schwarz gekennzeichnet.&lt;/p&gt;
&lt;p&gt;Lampendraht: Der Lampendraht, der zur Verbindung von Lampen und Leuchten verwendet wurde, könnte eine spezifische Farbcodierung aufweisen. Hier variiert die Farbe je nach Land und regionalen Normen. In einigen Ländern wurde der Lampendraht beispielsweise mit der Farbe braun gekennzeichnet.&lt;/p&gt;
&lt;p&gt;Tasterdraht: Der Tasterdraht, der für die Verbindung von Tastern oder Schaltern verwendet wurde, konnte ebenfalls eine eigene Farbcodierung haben. Auch hier können die Farben je nach Land und Normen variieren. In einigen Fällen wurde der Tasterdraht beispielsweise mit der Farbe grau gekennzeichnet.&lt;/p&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass die genannten Farbcodierungen nicht universell gültig sind und von Land zu Land oder sogar von Region zu Region variieren können. Bei älteren Elektroinstallationen ist es daher besonders wichtig, die tatsächliche Verkabelung von einem qualifizierten Elektriker überprüfen zu lassen, um Missverständnisse oder potenzielle Gefahren zu vermeiden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Bemessung der Strombelastbarkeit von fest verlegten Kabeln und Leitungen&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Bei der Bemessung der Strombelastbarkeit von fest verlegten Kabeln und Leitungen spielt der Leiterquerschnitt eine entscheidende Rolle. Allerdings werden auch andere Faktoren wie die Umgebungstemperatur und die Verlegeart berücksichtigt. Insbesondere die Verlegeart hat einen wesentlichen Einfluss auf die Strombelastbarkeit.&lt;/p&gt;
&lt;p&gt;Leitungen, die in ruhender Luft wie in einem Installationskanal oder in einer wärmegedämmten Wand verlegt werden, können die durch den Strom erzeugte Wärme nur schlecht an die Umgebung abgeben. Im Gegensatz dazu haben Kabel und Leitungen, die im Erdreich oder direkt auf der Wand verlegt sind, eine bessere Wärmeableitung.&lt;/p&gt;
&lt;p&gt;Die Fähigkeit eines Kabels oder einer isolierten Leitung, die entstehende Wärme abzuführen, beeinflusst ihre Strombelastbarkeit. Aus diesem Grund wurden insgesamt neun verschiedene Verlegearten definiert: A1, A2, 81, BZ, C, D, E, F und G.&lt;/p&gt;
&lt;p&gt;Die Auswahl der geeigneten Verlegeart und der entsprechenden Kabel und Leitungen richtet sich nach den spezifischen Anforderungen der Installation. Dabei werden Aspekte wie die Umgebungstemperatur, der Wärmeableitungskoeffizient und andere Einflussfaktoren berücksichtigt.&lt;/p&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass die korrekte Bemessung der Strombelastbarkeit und die Auswahl der richtigen Kabel und Leitungen eine Aufgabe für qualifizierte Fachkräfte ist. Elektroinstallateure und Elektroplaner verfügen über das notwendige Know-how, um die richtigen Entscheidungen zu treffen und sicherzustellen, dass die Installation den geltenden Normen und Vorschriften entspricht.&lt;/p&gt;
&lt;p&gt;Bei Fragen zur Bemessung von fest verlegten Kabeln und Leitungen sowie zur Auswahl der geeigneten Verlegeart empfehlen wir Ihnen, sich an einen Fachmann zu wenden, der Sie umfassend beraten kann.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Abweichende Betriebsbedingungen und Berechnung der Strombelastbarkeit&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Die angegebene Strombelastbarkeit von einzeln verlegten Kabeln oder Leitungen bezieht sich in der Regel auf eine Umgebungstemperatur von 30 °C. Wenn die tatsächliche Umgebungstemperatur von diesem Referenzwert abweicht, treten zusätzliche Belastungsfaktoren auf, die eine Neuberechnung der Strombelastbarkeit erfordern.&lt;/p&gt;
&lt;p&gt;Wenn es zu einer Häufung von Leitungen kommt, d.h. wenn mehrere Kabel oder Leitungen in engem Kontakt miteinander verlegt sind, kann dies zu einer Erhöhung der Umgebungstemperatur führen. Eine erhöhte Umgebungstemperatur wiederum beeinflusst die Wärmeabfuhr und somit die Strombelastbarkeit der Leitungen. In solchen Fällen müssen die spezifischen Betriebsbedingungen berücksichtigt und die Strombelastbarkeit entsprechend neu berechnet werden.&lt;/p&gt;
&lt;p&gt;Des Weiteren kann die Belastung durch Oberschwingungsströme die Strombelastbarkeit beeinflussen. Oberschwingungsströme entstehen beispielsweise in Anlagen mit nichtlinearen Verbrauchern wie Frequenzumrichtern oder elektronischen Geräten. Diese Ströme führen zu einer zusätzlichen Erwärmung der Leitungen und erfordern daher eine spezifische Berechnung der Strombelastbarkeit unter Berücksichtigung dieser abweichenden Betriebsbedingungen.&lt;/p&gt;
&lt;p&gt;Für die Berechnung der Strombelastbarkeit unter abweichenden Betriebsbedingungen stehen spezifische Normen und technische Dokumente zur Verfügung. Es ist wichtig, diese Normen und Dokumente zu konsultieren, um genaue und zuverlässige Ergebnisse zu erzielen. Elektroplaner und Fachleute mit Erfahrung in der Berechnung von Strombelastbarkeit können bei der Durchführung dieser Berechnungen unterstützen.&lt;/p&gt;
&lt;p&gt;Es ist ratsam, bei abweichenden Betriebsbedingungen und der Berechnung der Strombelastbarkeit immer auf qualifizierte Fachkräfte zurückzugreifen, um sicherzustellen, dass die Anforderungen der spezifischen Situation erfüllt werden und die Installation den geltenden Normen entspricht.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Der Schutz von Leitungen und Kabeln vor übermäßiger Erwärmung&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;...ist von entscheidender Bedeutung, um potenzielle Brandgefahren und Schäden an der elektrischen Installation zu vermeiden. Überstrom-Schutzeinrichtungen spielen dabei eine wichtige Rolle, indem sie die Leitungen und Kabel vor Überlastung und Kurzschluss schützen.&lt;/p&gt;
&lt;p&gt;Überlastströme treten auf, wenn die elektrische Verbraucherleistung in einem Stromkreis zu hoch ist. Dies kann beispielsweise durch den Betrieb von Geräten mit zu hoher Leistung oder durch eine zu hohe Anzahl von gleichzeitig betriebenen Geräten verursacht werden. Überlastströme führen zu einer übermäßigen Erwärmung der Leitungen und Kabel, was zu einer Beschädigung oder einem Brand führen kann. Überstrom-Schutzeinrichtungen wie Sicherungsautomaten oder Leitungsschutzschalter erkennen solche Überlastströme und unterbrechen den Stromkreis, um die Leitungen und Kabel vor Schäden zu schützen.&lt;/p&gt;
&lt;p&gt;Kurzschlussströme treten auf, wenn zwei leitende Stellen in einem Stromkreis miteinander in direktem Kontakt stehen und eine hohe Stromstärke fließt. Dies kann beispielsweise durch beschädigte Isolierungen, fehlerhafte Verbindungen oder defekte Geräte verursacht werden. Kurzschlussströme sind extrem gefährlich, da sie zu einem schnellen Anstieg der Stromstärke führen und eine enorme Wärmeentwicklung verursachen können. Überstrom-Schutzeinrichtungen reagieren sehr schnell auf Kurzschlüsse und unterbrechen den Stromkreis, um die Leitungen und Kabel vor Schäden und Bränden zu schützen.&lt;/p&gt;
&lt;p&gt;Die Auswahl und Dimensionierung der richtigen Überstrom-Schutzeinrichtungen basiert auf verschiedenen Faktoren wie dem Nennstrom der Leitungen, dem maximal zulässigen Betriebsstrom der angeschlossenen Geräte und den spezifischen Anforderungen der elektrischen Anlage. Elektroinstallateure und Fachleute für Elektrotechnik können bei der Auswahl und Installation der geeigneten Überstrom-Schutzeinrichtungen helfen, um einen effektiven Schutz der Leitungen und Kabel gegen zu hohe Erwärmung zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, die regelmäßige Wartung und Überprüfung der Überstrom-Schutzeinrichtungen sicherzustellen, um sicherzustellen, dass sie ordnungsgemäß funktionieren und den notwendigen Schutz bieten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Wichtige Einflussgrößen zur Strombelastbarkeit von Kabeln und Leitungen&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Die Strombelastbarkeit von Kabeln und Leitungen wird von verschiedenen Einflussgrößen bestimmt. Hier sind einige wichtige Faktoren, die die Strombelastbarkeit beeinflussen können:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Leiterquerschnitt: Der Querschnitt des Leiters bestimmt den maximalen Strom, den er tragen kann. Ein größerer Leiterquerschnitt ermöglicht eine höhere Strombelastbarkeit.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Anzahl der belasteten Adern: Wenn mehrere Adern in einem Kabel oder einer Leitung belastet werden, kann dies zu einer Erhöhung der Temperatur führen. Eine höhere Anzahl von belasteten Adern reduziert daher die Strombelastbarkeit.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Leiterisolierung: Die Qualität und Dicke der Isolierung beeinflussen die Wärmeableitung und somit die Strombelastbarkeit. Eine hochwertige Isolierung ermöglicht eine bessere Wärmeableitung und erhöht die Strombelastbarkeit.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Leitungs- und Kabelaufbau: Die Konstruktion des Kabels oder der Leitung kann ebenfalls die Wärmeableitung beeinflussen. Kabel mit einer besseren Wärmeableitung haben eine höhere Strombelastbarkeit.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Verlegeart: Die Art und Weise, wie Kabel und Leitungen verlegt werden, hat einen erheblichen Einfluss auf die Strombelastbarkeit. Unterschiedliche Verlegearten haben unterschiedliche Auswirkungen auf die Wärmeableitung und somit auf die Strombelastbarkeit.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Umgebungstemperatur: Die Umgebungstemperatur beeinflusst die Wärmeabfuhr der Kabel und Leitungen. Höhere Umgebungstemperaturen können zu einer Verringerung der Strombelastbarkeit führen.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Häufung von Kabeln oder Leitungen: Wenn mehrere Kabel oder Leitungen eng miteinander verlegt sind, kann dies zu einer Erhöhung der Umgebungstemperatur führen und somit die Strombelastbarkeit reduzieren.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Oberschwingungsströme: Oberschwingungsströme, die in nichtlinearen Lasten entstehen, können zu zusätzlicher Erwärmung führen und die Strombelastbarkeit verringern.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Dämmung: Die Qualität und Eigenschaften der Dämmung haben ebenfalls Auswirkungen auf die Strombelastbarkeit. Eine gute Dämmung ermöglicht eine effizientere Wärmeableitung und erhöht die Strombelastbarkeit.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Diese Einflussgrößen sind wichtige Aspekte, die bei der Auswahl, Dimensionierung und Installation von Kabeln und Leitungen berücksichtigt werden müssen, um eine sichere und zuverlässige elektrische Installation zu gewährleisten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/5834495926235627888/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/5834495926235627888' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5834495926235627888'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5834495926235627888'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/installations-drahte-farben-und-ihre.html' title='Installations - Drähte - Farben und ihre Bedeutung'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSTP1Zuu9Nj8gDmLR7vinHHXN60NMEu5HfiG-3ET2ARYNh3QyUul0HEMH23D9_ZOb59ask9bwbq0qx2TyNlsxQUotWXmzgR5MIwzRPyqPBmIckMYOCDtTIpXlDy2eS-Y0AiYnQVODCPm8WIiNm7FFJjb1q9alkD6sHR_RdqJL9dGIf-ZOAXMSGVwgH7g/s72-c/installations_draht_simple_elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-1465058547861161562</id><published>2023-06-13T11:05:00.000-07:00</published><updated>2023-06-13T11:05:01.097-07:00</updated><title type='text'>Installationskabel Farben und ihre Bestimmungen</title><content type='html'>&lt;h2 style=&quot;text-align: center;&quot;&gt;Leitungen und Kabel: Funktion, Eigenschaften und Kennzeichnung&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Es gibt eine Vielzahl von Kabeln mit unterschiedlichen Farben und Eigenschaften.&lt;/p&gt;
&lt;p&gt;Die Hauptaufgabe von Leitungen und Kabeln besteht darin, elektrische Energie vom Erzeuger zum Verbraucher zu transportieren. Sie dienen auch zur Übertragung von Signalen von Messgeräten, Steuer- und Regelgeräten.&lt;/p&gt;
&lt;p&gt;Isolierte Leitungen und Kabel bestehen aus einer oder mehreren Adern, die gegeneinander isoliert sind und durch eine gemeinsame Ummantelung zusammengehalten werden.&lt;/p&gt;
&lt;p&gt;Die in elektrischen Anlagen verwendeten isolierten Leitungen und Kabel müssen den geltenden Normen entsprechen und vom Hersteller entsprechend gekennzeichnet sein.&lt;/p&gt;
&lt;p&gt;In Deutschland hergestellte Leitungen werden zum Beispiel mit einem Aufdruck oder einem Kennfaden gekennzeichnet.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;table border=&quot;0&quot; cellpadding=&quot;0&quot; style=&quot;margin-left: auto; margin-right: auto;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center;&quot;&gt;
&lt;h5&gt;Installations Kabel&lt;/h5&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: center;&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgO7_QWituK1igdDXqjcv8Ejvyoqmdw7pKZYsY6dMBTl8r6nTIPUDR1k0IHZeWNLFHd5x-u88l3thPEl3b9jaSVTMnP-_ATlFsvHcYaj0_QtWNMghwA39SXGx7BZEmt6xUFcPr0_lCA3JQefyOChFRYLpPRQVUGnMmDxwKx6dyJxM8unzbHiyny0lRVhQ/s960/installations-kabel%20simple%20elektrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;720&quot; data-original-width=&quot;960&quot; height=&quot;240&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgO7_QWituK1igdDXqjcv8Ejvyoqmdw7pKZYsY6dMBTl8r6nTIPUDR1k0IHZeWNLFHd5x-u88l3thPEl3b9jaSVTMnP-_ATlFsvHcYaj0_QtWNMghwA39SXGx7BZEmt6xUFcPr0_lCA3JQefyOChFRYLpPRQVUGnMmDxwKx6dyJxM8unzbHiyny0lRVhQ/s320/installations-kabel%20simple%20elektrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h5&gt;Farbkennzeichnung von Leitungen und Kabeln&lt;/h5&gt;
&lt;p&gt;Für Leitungen und Kabel mit bis zu 5 Aderleitungen werden die einzelnen Aderisolierungen durch Farben gekennzeichnet. Wenn mehr als 5 Adern vorhanden sind, werden diese Adern in Schwarz ausgeführt und mit einer aufgedruckten Zahl versehen.&lt;/p&gt;
&lt;p&gt;Isolierte Leitungen werden sowohl mit als auch ohne Schutzleiter hergestellt. Die Eigenschaften dieser Installationskabel werden durch sogenannte Kurzzeichen gekennzeichnet.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;table border=&quot;0&quot; style=&quot;width: 100%;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: left; vertical-align: top;&quot;&gt;
&lt;table border=&quot;1&quot; style=&quot;border: 1px solid rgb(0, 0, 0); box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;&lt;b&gt;&amp;nbsp; Kurzzeichen&amp;nbsp; &lt;br /&gt;&lt;/b&gt;&lt;/td&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;&amp;nbsp; Bedeutung des Kurzzeichens&amp;nbsp; &lt;br /&gt;&lt;/b&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;A&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Ader&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;B&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Bleimantel&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;C&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Abschirmung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;F&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Flachleitung (Stegleitung)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;FF&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; feinstdrähtig&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;G&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Gummi Isolierung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;I&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Stegleitung (Imputzleitung)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;J&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Leitung mit Schutzleiter&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;L&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Leuchtröhrenleitung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;M&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Mantelleitung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;N&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; genormte Leitung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;O&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Leitung ohne Schutzleiter&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;Ö&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; ölfest&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;PL&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Pendelleitung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;St&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; statischer Schirm&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;S&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Sonderleitung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;T&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Leitungstrosse&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;U&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Umhüllung unbrennbar&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;W&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; wärmebeständige Leitung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;Y&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Kunststoff Isolierung&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; text-align: center;&quot;&gt;Z&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee;&quot;&gt;&amp;nbsp; Zwillingsausführung&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;/td&gt;
&lt;td style=&quot;text-align: right; vertical-align: top;&quot;&gt;

&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;blockquote&gt;
&lt;p&gt;Folgende Farbkennzeichnungen sind zwingend vorgeschrieben&lt;/p&gt;
&lt;p&gt;für den Schutzleiter (PE): grüngelb,&lt;/p&gt;
&lt;p&gt;für den Neutralleiter (N): blau,&lt;/p&gt;
&lt;p&gt;für den Schutzleiter mit Neutralleiterfunktion (PEN): grüngelb, &lt;br /&gt;zusätzlich sind für den PEN die Leitungsenden blau zu kennzeichnen.&lt;/p&gt;
&lt;/blockquote&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5 id=&quot;simpletools&quot;&gt;Zu den gängigsten Kabeln gehören z.B.:&lt;/h5&gt;
&lt;p&gt;&lt;b&gt;NYM-J 3x1,5mm²:&lt;/b&gt;&lt;br /&gt; Standard-Installationskabel für den Innenbereich&lt;br /&gt; Geeignet für Steckdosen, Lampen, Ventilatoren&lt;br /&gt; 3-poliges Kabel mit einem Leiterquerschnitt von 1,5mm² (einadrig)&lt;br /&gt; Farben: Blau (Neutralleiter), Schwarz oder Braun (Außenleiter), Gelb-Grün (Schutzleiter)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;NYM-J 5x1,5mm²:&lt;/b&gt;&lt;br /&gt; Standard-Installationskabel für den Innenbereich&lt;br /&gt; Geeignet für Schalter-Lampen-Verkabelung&lt;br /&gt; 5-poliges Kabel mit einem Leiterquerschnitt von 1,5mm² (einadrig)&lt;br /&gt; Farben: Blau (Neutralleiter), Schwarz (Außenleiter 1), Braun (Außenleiter 2), Grau (Außenleiter 3), Gelb-Grün (Schutzleiter)&lt;br /&gt; oder: Blau (Neutralleiter), Schwarz (Außenleiter 1), Schwarz (Außenleiter 2), Braun (Außenleiter 3), Gelb-Grün (Schutzleiter)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;NYM-J 5x2,5mm²:&lt;/b&gt;&lt;br /&gt; Standard-Installationskabel für den Innenbereich&lt;br /&gt; Geeignet für Motoren, CEE-Steckdosen, E-Herd&lt;br /&gt; 5-poliges Kabel mit einem Leiterquerschnitt von 2,5mm² (einadrig)&lt;br /&gt; Farben: Blau (Neutralleiter), Schwarz (Außenleiter 1), Braun (Außenleiter 2), Grau (Außenleiter 3), Gelb-Grün (Schutzleiter)&lt;br /&gt; oder: Blau (Neutralleiter), Schwarz (Außenleiter 1), Schwarz (Außenleiter 2), Braun (Außenleiter 3), Gelb-Grün (Schutzleiter)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;H07V-K 5g2,5mm²:&lt;/b&gt;&lt;br /&gt; Standard-Installationskabel für den Innenbereich&lt;br /&gt; Geeignet für Motoren, CEE-Steckdosen, E-Herd&lt;br /&gt; 5-poliges Kabel mit einem Leiterquerschnitt von 2,5mm² (feinadrig)&lt;br /&gt; Farben: Blau (Neutralleiter), Schwarz (Außenleiter 1), Braun (Außenleiter 2), Grau (Außenleiter 3), Gelb-Grün (Schutzleiter)&lt;br /&gt; oder: Blau (Neutralleiter), Schwarz (Außenleiter 1), Schwarz (Außenleiter 2), Braun (Außenleiter 3), Gelb-Grün (Schutzleiter)&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Bemessung von fest verlegten Kabeln und Leitungen&lt;/h5&gt;
&lt;p&gt;Die Strombelastbarkeit von fest verlegten Kabeln und Leitungen hängt hauptsächlich vom Leiterquerschnitt ab, kann jedoch auch von anderen Faktoren wie der Umgebungstemperatur beeinflusst werden. Die Verlegeart der Kabel und Leitungen hat einen wesentlichen Einfluss auf ihre Strombelastbarkeit.&lt;/p&gt;
&lt;p&gt;Kabel und Leitungen, die in ruhender Luft wie in einem Installationskanal oder in einer wärmegedämmten Wand verlegt sind, haben eine geringere Fähigkeit, die durch den Strom erzeugte Wärme an die Umgebung abzugeben. Im Gegensatz dazu weisen Kabel und Leitungen, die im Erdreich oder direkt auf der Wandoberfläche verlegt sind, eine bessere Wärmeableitung auf.&lt;/p&gt;
&lt;p&gt;Die Strombelastbarkeit von Kabeln und Leitungen mit guter Wärmeableitung ist höher.&lt;/p&gt;
&lt;p&gt;Es wurden insgesamt neun verschiedene Verlegearten (A1, A2, 81, BZ, C, D, E, F und G) festgelegt, die die Fähigkeit der Kabel und Leitungen zur Wärmeableitung beschreiben.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Abweichende Betriebsbedingungen&lt;/h5&gt;
&lt;p&gt;...erfordern eine angepasste Berechnung der Strombelastbarkeit von Kabeln und Leitungen. Die angegebene Strombelastbarkeit bezieht sich auf eine Umgebungstemperatur von 30 °C. Wenn die tatsächliche Umgebungstemperatur von diesem Referenzwert abweicht, wenn mehr als drei Adern belastet sind oder wenn Oberschwingungsströme auftreten, muss die Strombelastbarkeit entsprechend berechnet werden.&lt;/p&gt;
&lt;p&gt;Für abweichende Umgebungstemperaturen können Normen oder spezifische Berechnungsverfahren angewendet werden, um die Strombelastbarkeit zu ermitteln. Diese berücksichtigen den Einfluss der Temperatur auf die Leistungsfähigkeit der Kabel und Leitungen.&lt;/p&gt;
&lt;p&gt;Wenn mehr als drei Adern belastet sind, müssen die Wärmeverluste und der Einfluss der gegenseitigen Erwärmung der Adern auf die Strombelastbarkeit berücksichtigt werden.&lt;/p&gt;
&lt;p&gt;Bei Oberschwingungsströmen treten zusätzliche Verluste in den Kabeln und Leitungen aufgrund von erhöhten harmonischen Strömen auf. Diese Verluste können die Strombelastbarkeit beeinflussen und müssen daher bei der Berechnung berücksichtigt werden.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, die spezifischen Normen, Vorschriften oder Richtlinien Ihres Landes oder Ihrer Region zu konsultieren, um genaue Berechnungsmethoden für abweichende Betriebsbedingungen zu erhalten. Ein qualifizierter Elektroingenieur kann Ihnen bei der Berechnung der Strombelastbarkeit unter diesen Bedingungen behilflich sein.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Zum Schutz von Leitungen und Kabeln vor zu hoher Erwärmung&lt;/h5&gt;
&lt;p&gt;...werden Überstrom-Schutzeinrichtungen eingesetzt. Diese Einrichtungen dienen dazu, die Leitungen und Kabel vor Überlastung und Kurzschlüssen zu schützen, da diese Zustände zu einer erhöhten Erwärmung führen können.&lt;/p&gt;
&lt;p&gt;Überlastströme können in fehlerfreien Stromkreisen auftreten, wenn die Verbraucherleistung die Nennbelastung der Leitungen und Kabel überschreitet. Dies kann beispielsweise aufgrund einer zu hohen Stromaufnahme der angeschlossenen Geräte oder eines fehlerhaften Betriebs auftreten. Überstrom-Schutzeinrichtungen wie Sicherungen oder Leitungsschutzschalter reagieren auf diese Überlastströme und unterbrechen den Stromkreis, um eine übermäßige Erwärmung der Leitungen und Kabel zu verhindern.&lt;/p&gt;
&lt;p&gt;Kurzschlussströme entstehen, wenn es zu einem direkten Kurzschluss zwischen zwei leitenden Stellen kommt, die unter Spannung stehen. Dies kann beispielsweise durch eine beschädigte Isolierung oder einen fehlerhaften Anschluss verursacht werden. Kurzschluss-Schutzeinrichtungen wie Leitungsschutzschalter oder Leistungsschalter reagieren auf diese Kurzschlussströme und schalten den Stromkreis sofort ab, um eine Überhitzung und Schäden an den Leitungen und Kabeln zu verhindern.&lt;/p&gt;
&lt;p&gt;Diese Überstrom-Schutzeinrichtungen sind wichtige Sicherheitskomponenten in elektrischen Installationen und gewährleisten den zuverlässigen Schutz von Leitungen und Kabeln vor zu hoher Erwärmung, was potenzielle Brandgefahren reduziert und die Betriebssicherheit erhöht.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Die Strombelastbarkeit von Kabeln und Leitungen wird von mehreren wichtigen Einflussgrößen bestimmt:&lt;/h5&gt;
&lt;ul&gt;
&lt;li&gt;Leiterquerschnitt: Der Querschnitt des Leiters bestimmt den maximal zulässigen Strom, den das Kabel oder die Leitung tragen kann. Größere Querschnitte ermöglichen eine höhere Strombelastbarkeit.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Anzahl der belasteten Adern: Wenn mehrere Adern in einem Kabel oder einer Leitung belastet werden, wirkt sich dies auf die Wärmeentwicklung aus und kann die Strombelastbarkeit verringern. Die gegenseitige Erwärmung der Adern muss berücksichtigt werden.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Leiterisolierung: Die Art und Qualität der Isolierung beeinflusst die Wärmeableitung und damit die Strombelastbarkeit. Eine gute Isolierung hilft, die Wärme im Kabelinneren zu halten und die Umgebung weniger zu beeinflussen.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Leitungs- und Kabelaufbau: Die Konstruktion des Kabels oder der Leitung, einschließlich der verwendeten Materialien und der Schichten, kann die Wärmeableitung und somit die Strombelastbarkeit beeinflussen.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Verlegeart: Die Art und Weise, wie das Kabel oder die Leitung verlegt wird, hat einen erheblichen Einfluss auf die Wärmeableitung. Die Verlegeart kann in Bezug auf die Wärmeabgabe unterschiedliche Eigenschaften aufweisen.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Umgebungstemperatur: Die Umgebungstemperatur wirkt sich direkt auf die Wärmeableitung aus. Höhere Temperaturen führen zu einer schlechteren Wärmeableitung und können die Strombelastbarkeit verringern.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Häufung von Kabeln oder Leitungen: Wenn mehrere Kabel oder Leitungen in der Nähe voneinander verlegt sind, kann die Wärmeableitung beeinträchtigt werden, was die Strombelastbarkeit reduzieren kann.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Oberschwingungsströme: Das Vorhandensein von Oberschwingungsströmen, die durch nicht-lineare Lasten verursacht werden, kann zusätzliche Verluste und Erwärmung in den Kabeln und Leitungen verursachen. Diese müssen bei der Bestimmung der Strombelastbarkeit berücksichtigt werden.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Dämmung: Die Art und Qualität der Dämmung um das Kabel oder die Leitung kann die Wärmeableitung und somit die Strombelastbarkeit beeinflussen.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Diese Einflussgrößen sollten bei der Berechnung der Strombelastbarkeit von Kabeln und Leitungen sorgfältig berücksichtigt werden, um eine sichere und zuverlässige elektrische Installation zu gewährleisten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Eine Kennzeichnung der Kabeln mit aufgedruckten Buchstaben- und Zahlenkürzeln dient der leichteren Erkennung von Bauart und für den Verwendungszweck des Kabels.&lt;/p&gt;
&lt;h4&gt;Kennzeichen Tabelle:&lt;/h4&gt;
&lt;table margin-left:=&quot;&quot; margin-right:=&quot;&quot; style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0); height: 649px; margin-left: auto; margin-right: auto; width: 718px;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;border-top: 1px solid rgb(0, 0, 0); text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;color: red;&quot;&gt;ein Beispiel für eine&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;color: red;&quot;&gt;Silikonschlauchleitung&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-top: 1px solid rgb(0, 0, 0); text-align: center; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-top: 1px solid rgb(0, 0, 0); text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;H&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;05&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;S&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;S&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;-F&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;5&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;X&lt;/b&gt;&lt;/td&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #f2b650; text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;1,5&lt;/b&gt;&lt;/td&gt;
&lt;td style=&quot;border-top: 1px solid rgb(0, 0, 0); text-align: center; vertical-align: middle;&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style=&quot;border-top: 1px solid rgb(0, 0, 0); text-align: center; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); border-top: 1px solid rgb(0, 0, 0); text-align: center; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Kennzeichnung&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Harmonisierte Leitung&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;H&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Leiterquerschnitt in mm²&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Anerkannter Nationaler Typ&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;A**&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: bottom;&quot;&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Schutzleiter&lt;/b&gt;&lt;/span&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: bottom;&quot;&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Bemessungsspannung U0 / U*&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;X&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;ohne Schutzleiter&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;100/100 V&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;01&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;G&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;mit Schutzleiter&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;300/300 V&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;03&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;border-right: 1px solid rgb(0, 0, 0); text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;300/500 V&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;05&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;border-right: 1px solid rgb(0, 0, 0); text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Aderzahl&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;450/750 V&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;07&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: bottom;&quot;&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Leiterform&lt;/b&gt;&lt;/span&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: bottom;&quot;&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Isolierwerkstoff des Leiters&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0);&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-D&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;feindrähtig - Schweißleitung&lt;/span&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Ethylen - Propylen - Kautschuk&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;B&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-E&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;feinstdrähtig - Schweißleitung&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Ethylen - Propylen - Gummi&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;R&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-F&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;feindrähtig - flexible Leitung&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Silikon - Gummi&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;S&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-H&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;feinstdrähtig - flexible Leitung&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;PVC - weich&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;V&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-K&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;feindrähtig - fest verlegte Leitung&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Thermoplast aus Polyolefinen&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Z&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-R&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;mehrdrähtiger Rundleiter&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: bottom;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Mantelwerkstoff&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-U&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;eindrähtiger Rundleiter&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Glasfasergeflecht&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;J&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;-Y&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Lahnlitzenleiter - hochflexibel&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Polychloropren - Kautschuk&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;N&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;border-right: 1px solid rgb(0, 0, 0); text-align: left; vertical-align: bottom;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 8pt; text-decoration: underline;&quot;&gt;&lt;b&gt;Besonderheiten im Aufbau&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Polyurethan&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Q&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;H&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;flache - aufteilbare Leitung&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Ethylen - Propylen - Gummi&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;R&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;H2&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;flache - nicht aufteilbare Leitung&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Silikon - Gummi&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;S&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;H6&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;flache Leitung mit 3 oder mehr Adern&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Textilgeflecht&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;T&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;H7&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Leitung mit extrudierter zweischichtiger Isolierhülle&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;PVC - weich&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;V&amp;nbsp;&lt;/span&gt;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-right: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;border-bottom: 1px solid rgb(0, 0, 0); vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;H8&lt;/span&gt;&lt;/td&gt;
&lt;td rowspan=&quot;2&quot; style=&quot;background-color: #ffff99; text-align: left; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 8pt;&quot;&gt;Wendelleitung&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;td style=&quot;vertical-align: middle;&quot;&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/1465058547861161562/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/1465058547861161562' title='1 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1465058547861161562'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1465058547861161562'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/drahte-und-kabel.html' title='Installationskabel Farben und ihre Bestimmungen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgO7_QWituK1igdDXqjcv8Ejvyoqmdw7pKZYsY6dMBTl8r6nTIPUDR1k0IHZeWNLFHd5x-u88l3thPEl3b9jaSVTMnP-_ATlFsvHcYaj0_QtWNMghwA39SXGx7BZEmt6xUFcPr0_lCA3JQefyOChFRYLpPRQVUGnMmDxwKx6dyJxM8unzbHiyny0lRVhQ/s72-c/installations-kabel%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-8299224154388889353</id><published>2023-06-13T11:02:00.000-07:00</published><updated>2023-06-13T11:02:08.011-07:00</updated><title type='text'>Gefahren des elektrischen Stromes</title><content type='html'>&lt;h2&gt;Beim Kontakt von Menschen oder Tieren mit elektrischem Strom können folgende Schädigungen oder Verletzungen auftreten:&lt;/h2&gt;
&lt;ul&gt;
&lt;li&gt;Verbrennungen (von Strommarken bis hin zu Verkohlungen)&lt;/li&gt;
&lt;li&gt;Muskelkrämpfe&lt;/li&gt;
&lt;li&gt;Bewusstlosigkeit&lt;/li&gt;
&lt;li&gt;Herzkammerflimmern oder Herzstillstand&lt;/li&gt;
&lt;li&gt;Atemlähmung&lt;/li&gt;
&lt;li&gt;Schockwirkung und Tod&lt;/li&gt;
&lt;li&gt;Sekundäre Verletzungen (z. B. Sturz von einer Leiter)&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Die schädliche Wirkung des elektrischen Stroms hängt von mehreren Faktoren ab:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Stromstärke, die durch den Körper fließt&lt;br /&gt; Stromweg durch den Körper&lt;br /&gt; Dauer der Stromeinwirkung&lt;br /&gt; Art und Frequenz des Stroms&lt;br /&gt; körperliche Verfassung des Betroffenen&lt;/p&gt;
&lt;p&gt;Die meisten Stromunfälle ereignen sich aufgrund von Unaufmerksamkeit und menschlichem Versagen. Um das Risiko zu vermeiden oder zu reduzieren, ist besondere Sorgfalt beim Arbeiten an elektrischen Anlagen erforderlich.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhWtxHU-xAlkHLLwMUfZcC-5DmUDmLM5_Qmn6j1Fmf0WNhRLNqCJUQOyxSPfPEbwuwWGcQjHfeYqpnl41trpRdU5vmgwiZq8K8R1Qpq7BAk92NGa8EZbS-L_E899SAMMCSq4L_PVkFfdh86KJoaLyqu8AvyNO2dWqjMvHrtQz36VE0J9YS8_kAitu93CA/s426/stromnetzrieplayat.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;282&quot; data-original-width=&quot;426&quot; height=&quot;212&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhWtxHU-xAlkHLLwMUfZcC-5DmUDmLM5_Qmn6j1Fmf0WNhRLNqCJUQOyxSPfPEbwuwWGcQjHfeYqpnl41trpRdU5vmgwiZq8K8R1Qpq7BAk92NGa8EZbS-L_E899SAMMCSq4L_PVkFfdh86KJoaLyqu8AvyNO2dWqjMvHrtQz36VE0J9YS8_kAitu93CA/s320/stromnetzrieplayat.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Der elektrische Strom kann auf den Körper verschiedene Wirkungen haben, sowohl positive als auch negative. Hier sind einige wichtige Punkte zu den Auswirkungen des elektrischen Stroms auf den Körper:&lt;/b&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Elektrischer Schlag: Wenn der Körper einen elektrischen Strom durchfließt, kann dies zu einem elektrischen Schlag führen. Die Schwere des Schlags hängt von der Stromstärke, der Spannung, der Dauer und dem Weg des Stroms durch den Körper ab. Ein elektrischer Schlag kann zu Verletzungen, Verbrennungen oder sogar zum Tod führen, abhängig von der Stärke des Stroms.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Muskelreaktion: Elektrischer Strom kann die Muskeln stimulieren oder beeinflussen. Starke Ströme können Muskelkontraktionen verursachen, die dazu führen können, dass sich die Muskeln zusammenziehen und den Körper in gefährlichen Situationen festhalten. Dies kann zu Knochenbrüchen oder anderen Verletzungen führen, insbesondere wenn die Kontraktion die Kontrolle über die Muskeln des Körpers beeinträchtigt.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Herzrhythmusstörungen: Der elektrische Strom kann den normalen Herzrhythmus stören. Ein starkes elektrisches Signal von außen kann die normale Erregung des Herzens stören und zu Herzrhythmusstörungen wie Herzrasen (Tachykardie), Herzstillstand oder Kammerflimmern führen. Dies kann lebensbedrohlich sein und erfordert sofortige medizinische Hilfe.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Gewebeschäden: Bei hoher Stromstärke kann der elektrische Strom Gewebeschäden verursachen, insbesondere an den Stellen, wo der Strom in den Körper eintritt und austritt. Dies kann zu Verbrennungen, Gewebenekrosen (Absterben von Gewebe) oder anderen Verletzungen führen.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Langzeiteffekte: Wiederholte Exposition gegenüber elektrischem Strom kann langfristige Auswirkungen auf den Körper haben. Chronische Exposition kann zu neurologischen Problemen, Gedächtnisverlust, Schlafstörungen oder anderen gesundheitlichen Problemen führen. Langzeitfolgen hängen von Faktoren wie der Intensität und Dauer der Exposition ab.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass die Auswirkungen des elektrischen Stroms auf den Körper von verschiedenen Faktoren abhängen, einschließlich der Stromstärke, der Spannung, der Dauer der Exposition, dem Weg des Stroms durch den Körper, dem individuellen Gesundheitszustand und anderen Umständen. Im Falle eines elektrischen Unfalls ist es immer ratsam, sofort medizinische Hilfe zu suchen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Fremdströme können die Funktion von Organen beeinflussen, insbesondere wenn sie über das Herz fließen. Hier sind einige ergänzende Informationen zu den von Ihnen genannten Punkten:&lt;/b&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Muskelverkrampfung: Wenn ein Strom durch den Körper fließt, können sich die Muskeln verkrampfen, was zu einer sogenannten &quot;Stromkontraktion&quot; führt. Diese Kontraktion kann dazu führen, dass die Person den Kontakt nicht freiwillig loslassen kann. Es ist wichtig zu beachten, dass der Körper in solchen Situationen oft von reflexartigen Muskelkontraktionen betroffen ist und nicht in der Lage ist, die Kontrolle über die Handlung zu behalten.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Herzrhythmusstörungen: Bei Wechselstrom kann das Herz auf die schnellen und starken Impulse von außen reagieren und versuchen, ihnen zu folgen. Dies führt zu Unregelmäßigkeiten im Herzrhythmus, was als Arrhythmie bezeichnet wird. Wenn der Stromfluss in die vulnerable Phase des Herzzyklus fällt, kann dies zu lebensbedrohlichen Zuständen wie Kammerflimmern führen. Kammerflimmern ist ein chaotischer und ineffektiver Herzschlag, der zu einem Kreislaufstillstand führen kann.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Schutzmaßnahmen: Um sich vor den Auswirkungen gefährlicher Stromflüsse auf das Herz zu schützen, werden Sicherheitsvorkehrungen wie Fehlerstrom-Schutzschalter (FI-Schutzschalter) eingesetzt. Ein FI-Schutzschalter erkennt einen Stromfluss zwischen dem Körper einer Person (oder eines Tieres) und der Erde und schaltet bei einem bestimmten Fehlerstromwert schnell ab. Dadurch wird das Risiko von Herzrhythmusstörungen wie Kammerflimmern reduziert.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Niedrige Körperströme: Bei Elektrounfällen in Niederspannungsanlagen, bei denen die Stromstärke in der Regel einige Milliampere bis zu mehreren Zehntelampere beträgt, ist das Risiko schwerwiegender Herzrhythmusstörungen geringer. Dennoch können auch niedrige Körperströme zu Verletzungen und anderen gesundheitlichen Problemen führen.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Es ist wichtig zu betonen, dass die beschriebenen Schutzmaßnahmen wie FI-Schutzschalter dennoch unerlässlich sind, um das Risiko von Stromunfällen und deren potenziell schwerwiegenden Folgen zu minimieren. Vorsichtsmaßnahmen und ordnungsgemäße Installationen sind entscheidend, um die Sicherheit im Umgang mit elektrischem Strom zu gewährleisten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Der Körperwiderstand spielt eine entscheidende Rolle bei den Auswirkungen eines Stromschlags. Hier sind weitere Informationen zu diesem Thema:&lt;/b&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Körperwiderstand: Der Körperwiderstand ist eine Kombination aus dem intrinsischen Widerstand des Körpergewebes und den Übergangswiderständen an den Stellen, an denen der Strom in den Körper eintritt und austritt. Der Körperwiderstand variiert je nach individuellen Faktoren wie Hautfeuchtigkeit, Kontaktfläche, Hautbeschaffenheit und anderen Umständen.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Auswirkungen der Spannung: Der durch den Körper fließende Strom hängt von der angelegten Spannung und dem Körperwiderstand ab. Nach dem Ohmschen Gesetz (I = U/R) kann bei einer gegebenen Spannung eine höhere Widerstandswert einen geringeren Stromfluss durch den Körper bedeuten, während ein niedrigerer Widerstand zu einem höheren Stromfluss führen kann.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Einfluss der Berührungsfläche: Die Berührungsfläche zwischen dem Körper und dem unter Spannung stehenden Teil beeinflusst den Übergangswiderstand. Eine größere Berührungsfläche kann den Übergangswiderstand verringern, während eine kleinere Fläche zu einem höheren Widerstand führen kann.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Einfluss der Feuchtigkeit: Feuchtigkeit, sei es durch Schweiß oder andere Faktoren wie nasse Umgebungen, verringert den Übergangswiderstand. Wenn der Körper feucht ist, kann der Strom leichter durch den Körper fließen, da der Widerstand geringer ist. Dadurch besteht ein erhöhtes Risiko für Stromschäden.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass die Auswirkungen eines Stromschlags nicht nur von der Stromstärke abhängen, sondern auch von der Dauer des Stromflusses, dem Weg des Stroms durch den Körper und anderen individuellen Faktoren. Eine hohe Stromstärke, insbesondere wenn sie über das Herz fließt, kann schwerwiegende Verletzungen oder sogar den Tod verursachen. Deshalb ist es von größter Bedeutung, Sicherheitsmaßnahmen zu ergreifen und elektrische Risiken zu vermeiden, um Unfälle zu verhindern.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;blockquote&gt;
&lt;p&gt;Wechselspannungen über 50 V sind lebensgefährlich.&lt;br /&gt;Gleichspannungen über 120 V sind lebensgefährlich.&lt;br /&gt;Wechselstrom mit einer Frequenz von 50 Hz ist gefährlicher als Gleichstrom, weil es bereits bei dieser Frequenz zu Herzkammerflimmern kommen kann.&lt;/p&gt;
&lt;/blockquote&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Wegen dieser hohen Unfallgefahr ist das Arbeiten an unter Spannung stehenden Anlageteilen generell verboten!&lt;/p&gt;
&lt;p&gt;Bei Betriebsspannungen über 50V Wechselspannung oder 120V Gleichspannung sind Arbeiten an unter Spannung stehenden Teilen nur dann gestattet, wenn diese Teile aus wichtigen Gründen nicht abgeschaltet werden können. Solche Arbeiten dürfen jedoch nur durch Elektrofachkräfte mit Zusatzausbildung ausgeführt werden jedoch nicht durch Auszubildende Lehrlinge.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Beim elektrischen Stromunfall wird zwischen direktem Berühren und indirektem Berühren unterschieden. Hier sind weitere Informationen zu diesen Begriffen:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Direktes Berühren:&lt;/b&gt; Beim direkten Berühren hat der menschliche Körper direkten Kontakt mit betriebsmäßig unter Spannung stehenden Teilen, wie beispielsweise einem aktiven Leiter. Um direktes Berühren zu verhindern, werden spannungsführende Teile normalerweise mit Isolierungen oder Abdeckungen versehen, um den Kontakt mit ihnen zu verhindern. Dies reduziert das Risiko eines Stromunfalls durch direkte Berührung.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Indirektes Berühren:&lt;/b&gt; Beim indirekten Berühren besteht die Gefahr, dass Spannung an Teile gelangt, die normalerweise nicht unter Spannung stehen, aufgrund eines Isolationsfehlers. Das bedeutet, dass ein Isolationsschaden aufgetreten ist und eine leitende Verbindung, auch Körperschluss genannt, zwischen den unter Spannung stehenden Teilen und einem anderen leitenden Teil besteht, wie beispielsweise dem Gehäuse einer elektrischen Maschine. Indirektes Berühren kann gefährlich sein, da der Stromfluss über den Körper erfolgen kann, obwohl keine direkte Berührung mit spannungsführenden Teilen besteht. Es ist wichtig, solche Isolationsfehler zu vermeiden und regelmäßige Inspektionen und Wartungen durchzuführen, um das Risiko indirekter Berührung zu minimieren.&lt;/p&gt;
&lt;p&gt;Die Unterscheidung zwischen direktem und indirektem Berühren ist wichtig, um geeignete Schutzmaßnahmen zu ergreifen und die Sicherheit bei elektrischen Installationen und Geräten zu gewährleisten. Isolationsmaßnahmen, Schutzleiterverbindungen und andere Schutzvorrichtungen dienen dazu, das Risiko von Stromunfällen durch Berührung zu reduzieren.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/8299224154388889353/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/8299224154388889353' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/8299224154388889353'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/8299224154388889353'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/gefahren-des-elektrischen-stromes.html' title='Gefahren des elektrischen Stromes'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhWtxHU-xAlkHLLwMUfZcC-5DmUDmLM5_Qmn6j1Fmf0WNhRLNqCJUQOyxSPfPEbwuwWGcQjHfeYqpnl41trpRdU5vmgwiZq8K8R1Qpq7BAk92NGa8EZbS-L_E899SAMMCSq4L_PVkFfdh86KJoaLyqu8AvyNO2dWqjMvHrtQz36VE0J9YS8_kAitu93CA/s72-c/stromnetzrieplayat.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-6348625342558241685</id><published>2023-06-13T11:01:00.000-07:00</published><updated>2023-06-13T11:01:03.345-07:00</updated><title type='text'>Die 5 Sicherheitsregeln beim arbeiten mit Strom</title><content type='html'>&lt;h4 style=&quot;text-align: center;&quot;&gt;Diese Punkte schützen Sie vor Stromunfällen&lt;/h4&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;1. FREISCHALTEN!&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;Vorsicht bei Rückspannungen; nicht unter Spannung arbeiten!&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&lt;b&gt;2. GEGEN WIEDEREINSCHALTEN SICHERN!&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;Sicherungen entfernen und Warntafeln anbringen!&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&lt;b&gt;3. AUF SPANNUNGSFREIHEIT PRÜFEN!&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;Das Spannungsprüfgerät soll auf seine Funktionsfähigkeit geprüft werden (3-Punkt-Prüfung)!&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&lt;b&gt;4. ENTLADEN, ERDEN UND KURZSCHLIESSEN!&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;Mit geeigneten Kurzschlussvorrichtungen - unbedingt die Reihenfolge einhalten!&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&lt;b&gt;5. GEGEN BENACHBARTE, UNTER SPANNUNG STEHENDE TEILE SCHÜTZEN, ABDECKEN UND EINGRENZEN.&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;Mit geeigneten Abdeckmaterialien wie Isoliermatten benachbarte unter Spannung stehende Teile abdecken!&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&amp;nbsp;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiknoc7wMgRQi45fuFKDmtjJ_bkE8zIC9CnsggmvadPjVv3LJSjBWT_-acFxy4Diu1lfuujpFtt9Frfyqv0TmD4ThVoAjcyYcP_DNdYYemC8lClJNi4yZwYKczJRTfp-x1fEfKbL2mL6ZGd769gPxNbGYasA4WrZwQqScYmckm7QZhzoTh2bCd_xcdMQ/s800/Die%205%20Sicherheitsregeln%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;480&quot; data-original-width=&quot;800&quot; height=&quot;384&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiknoc7wMgRQi45fuFKDmtjJ_bkE8zIC9CnsggmvadPjVv3LJSjBWT_-acFxy4Diu1lfuujpFtt9Frfyqv0TmD4ThVoAjcyYcP_DNdYYemC8lClJNi4yZwYKczJRTfp-x1fEfKbL2mL6ZGd769gPxNbGYasA4WrZwQqScYmckm7QZhzoTh2bCd_xcdMQ/w640-h384/Die%205%20Sicherheitsregeln%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;1. Freischalten&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Vor jeglichen Arbeiten muss die Anlage freigeschaltet werden, da Arbeiten an Teilen, die unter Spannung stehen, verboten sind. Freischalten bedeutet, dass die Spannung an der Anlage abgeschaltet wird. Hierfür können verschiedene Maßnahmen ergriffen werden:&lt;/p&gt;
&lt;p&gt;- Den Leitungsschutzschalter ausschalten.&lt;br /&gt;- Schmelzsicherungen herausdrehen.&lt;br /&gt;- NH-Sicherungen ziehen.&lt;br /&gt;- Fehlerstromschutzschalter ausschalten.&lt;br /&gt;- Motorschutzschalter ausschalten.&lt;br /&gt;- Den Hauptschalter ausschalten.&lt;br /&gt;- Bei Elektrogeräten mit Stecker den Stecker ziehen.&lt;br /&gt;- ...&lt;/p&gt;
&lt;p&gt;Wichtig ist zu beachten, dass es nicht ausreicht, beispielsweise beim Installieren einer Lampe lediglich den Lichtschalter auszuschalten. Stattdessen muss der gesamte Stromkreis freigeschaltet werden. Schütze oder Relais dürfen nicht zum Freischalten verwendet werden.&lt;/p&gt;
&lt;p&gt;Ausnahmen:&lt;br /&gt;- Zum Messen und Testen (nur durch qualifiziertes Fachpersonal).&lt;br /&gt;- Wenn Gefahr für Mensch und Leben besteht.&lt;br /&gt;- Speziell angeordnete Arbeiten an spannungsführenden Anlagen (hier gelten besondere VDE-Vorschriften).&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;2. Gegen Wiedereinschalten sichern&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Um sicherzustellen, dass die Anlage während der Arbeiten freigeschaltet bleibt und niemand sie versehentlich wieder einschaltet, müssen entsprechende Sicherheitsmaßnahmen ergriffen werden.&lt;/p&gt;
&lt;p&gt;- Leitungsschutzschalter können mit einer speziellen Klebefolie überklebt werden, auf der &quot;Nicht einschalten - Gefahr&quot; steht. Alternativ kann auch einfaches Klebeband mit einem Warnzettel verwendet werden.&lt;br /&gt;- Viele Leitungsschutzschalter lassen sich mit einem passenden Sperrelement gegen Wiedereinschalten sichern.&lt;br /&gt;- Schmelzsicherungen können in die Hosentasche gesteckt werden. Es ist auch möglich, einen Blindeinsatz zu verwenden. Dieses Verfahren kann auch auf NH-Sicherungen angewendet werden.&lt;br /&gt;- Hauptschalter von Maschinen können mit einem Vorhängeschloss abgeschlossen werden.&lt;br /&gt;- Steckverbindungen (Stecker/Kupplungen) sollten gegen versehentliches Einstecken geschützt werden.&lt;br /&gt;- Zusätzlich sollte während der gesamten Arbeitsdauer ein Warnschild angebracht werden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;3. Auf Spannungsfreiheit prüfen&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;An der Arbeitsstelle muss mithilfe eines zweipoligen Spannungsmessers (Phasenprüfstifte sind nicht geeignet) die Spannungsfreiheit festgestellt werden. Vor der Verwendung des Spannungsprüfers sollte dessen Funktion getestet werden.&lt;/p&gt;
&lt;p&gt;Die Spannungsfreiheit muss allpolig festgestellt werden, das bedeutet, dass alle Außenleiter (Phasen) gegen &quot;Null&quot; (Neutralleiter) oder Erde (N/PE) gemessen werden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;4. Entladen, Erden und Kurzschließen&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Das Erden und Kurzschließen ist nur bei Anlagen mit einer Nennspannung größer als 1kV zwingend erforderlich. Eine Ausnahme bilden Freileitungen, die auch bei einer Spannung unter 1kV geerdet und kurzgeschlossen werden müssen.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, zuerst zu erden und dann die aktiven Teile kurzzuschließen, wobei diese Verbindung von der Arbeitsstelle aus sichtbar sein muss. Wenn Leitungen getrennt werden, muss an beiden Enden geerdet und kurzgeschlossen werden.&lt;/p&gt;
&lt;p&gt;Für das Erden und Kurzschließen stehen spezielle Vorrichtungen und Werkzeuge zur Verfügung (bei Anlagen über 1kV wird ein einpoliger Spannungsprüfer verwendet, der wie oben beschrieben vorher geprüft werden muss).&lt;/p&gt;
&lt;p&gt;Das Erden und Kurzschließen hat den Zweck, dass sich parallel verlaufende freigeschaltete Leitungsstrecken nicht aufladen können, was beispielsweise bei Freileitungen auftreten kann. Außerdem würde bei einer geerdeten und kurzgeschlossenen Anlage bei irrtümlichem Einschalten sofort die vorgeschaltete Sicherung ansprechen (Achtung: Es besteht die Gefahr von Lichtbogenbildung).&lt;/p&gt;
&lt;p&gt;Das Entladen, Erden und Kurzschließen ist auch bei Arbeiten an Kondensatoren dringend zu empfehlen. In den meisten Fällen können Kondensatoren mithilfe eines Spannungsprüfers entladen werden, um Lichtbögen (Funken) zu vermeiden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;5. Benachbarte, unter Spannung stehende Teile schützen, abdecken und eingrenzen&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Falls Anlagenteile in der Nähe der Arbeitsstelle nicht freigeschaltet werden können, müssen die weiterhin unter Spannung stehenden Teile für die Dauer der Arbeiten abgedeckt oder abgegrenzt werden, um einen sicheren Arbeitsbereich zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Bei Anlagen unter 1kV genügen isolierende Tücher, Schläuche und Formstücke zum Abdecken der benachbarten spannungsführenden Teile. Es ist wichtig, dass diese Materialien ausreichend isolierend sind, um einen Kontakt mit den unter Spannung stehenden Teilen zu verhindern.&lt;/p&gt;
&lt;p&gt;Bei Anlagen über 1kV sind zusätzliche Maßnahmen erforderlich. Neben isolierenden Materialien wie Tüchern sollten Absperrtafeln, Seile und Warntafeln verwendet werden, um den Bereich um die spannungsführenden Teile herum abzusperren und zu kennzeichnen. Dadurch wird verhindert, dass unbefugte Personen den Bereich betreten und möglicherweise einem Risiko ausgesetzt sind.&lt;/p&gt;
&lt;p&gt;Diese Schutzmaßnahmen dienen dazu, die Sicherheit der Arbeitskräfte zu gewährleisten und das Risiko eines unbeabsichtigten Kontakts mit unter Spannung stehenden Teilen zu minimieren. Es ist wichtig, die spezifischen Vorschriften und Richtlinien des Arbeitsschutzes sowie die örtlichen Bestimmungen zu beachten, um die richtigen Schutzvorkehrungen zu treffen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/6348625342558241685/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/6348625342558241685' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/6348625342558241685'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/6348625342558241685'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/sicherheitsregeln.html' title='Die 5 Sicherheitsregeln beim arbeiten mit Strom'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiknoc7wMgRQi45fuFKDmtjJ_bkE8zIC9CnsggmvadPjVv3LJSjBWT_-acFxy4Diu1lfuujpFtt9Frfyqv0TmD4ThVoAjcyYcP_DNdYYemC8lClJNi4yZwYKczJRTfp-x1fEfKbL2mL6ZGd769gPxNbGYasA4WrZwQqScYmckm7QZhzoTh2bCd_xcdMQ/s72-w640-h384-c/Die%205%20Sicherheitsregeln%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-1547354890900283793</id><published>2023-06-13T10:59:00.002-07:00</published><updated>2023-06-13T10:59:26.765-07:00</updated><title type='text'>Telefondosen richtig anschließen</title><content type='html'>&lt;h2&gt;&amp;nbsp;Anleitung zum Anschließen von Telefondosen&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Vorbereitung:&lt;/b&gt;&lt;br /&gt;Sammeln Sie das erforderliche Werkzeug, einschließlich eines Schraubendrehers (ideal ist ein Kreuzschlitzschraubendreher), eines Kabelschneiders und einer Abisolierzange.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Vorbereitung der Telefonleitung:&lt;/b&gt;&lt;br /&gt; Suchen Sie das Ende der Telefonleitung, das an die Telefonsteckdose angeschlossen werden soll. In der Regel befindet sich eine kleine Kunststoffabdeckung am Ende der Leitung.&lt;br /&gt; Entfernen Sie die Kunststoffabdeckung vorsichtig, um die Drähte freizulegen. In der Regel finden Sie vier Drähte: rot, grün, gelb und schwarz.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Anschließen der Telefonleitung:&lt;/b&gt;&lt;br /&gt; Nehmen Sie die Telefonsteckdose TAE und öffnen Sie sie, indem Sie die Schrauben an der Ober- und Unterseite der Abdeckung lösen.&lt;br /&gt; In der Telefonsteckdose finden Sie vier Anschlussklemmen oder Schraubklemmen mit den entsprechenden Bezeichnungen: a, b, c und d.&lt;br /&gt; Nehmen Sie den roten Draht und schließen Sie ihn an die Klemme a an. Lockern Sie die Schraubklemme, legen Sie den Draht hinein und ziehen Sie die Schraube wieder fest, um eine sichere Verbindung herzustellen. Wiederholen Sie diesen Vorgang für die anderen drei Drähte: grün an Klemme b, gelb an Klemme c und schwarz an Klemme d.&lt;br /&gt; Stellen Sie sicher, dass die Drähte fest an den Klemmen befestigt sind und kein Draht herausragt.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Abschluss:&lt;/b&gt;&lt;br /&gt; Schließen Sie die Telefonsteckdose, indem Sie die Abdeckung wieder aufsetzen und die Schrauben an der Ober- und Unterseite festziehen.&lt;br /&gt; Überprüfen Sie noch einmal, ob alle Drähte ordnungsgemäß an den Klemmen befestigt sind.&lt;br /&gt; Testen Sie die Telefonsteckdose, indem Sie ein Telefon anschließen und prüfen, ob Sie eine Verbindung herstellen können.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;&amp;nbsp;&lt;/h5&gt;
&lt;h5&gt;Telefondosen im Überblick:&lt;/h5&gt;
&lt;p&gt;Bei einem herkömmlichen Telefonanschluss mit einer &lt;b&gt;TAE-Dose&lt;/b&gt; wird die ankommende Leitung an die Anschlüsse 1 und 2 angeschlossen&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjYGbsGuv565-qCIpMR8ESzD_xb9GOWxCciXtwRl_5PG-ZW8q5uue8uTr3Aa4Sw3ZIexn24QklM3af5wSswA-eMWYR2Lk54XYKHutXJurNV8wMIphYrR658H1mGHRFKs-e-ougf_-bl-lOuUVsOalMk7SyaOKyXOkZ9F2Dms0sNHsibFFFyUD7G_Jf37Q/s234/telefondose_Einfachanschlussr_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;230&quot; data-original-width=&quot;234&quot; height=&quot;230&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjYGbsGuv565-qCIpMR8ESzD_xb9GOWxCciXtwRl_5PG-ZW8q5uue8uTr3Aa4Sw3ZIexn24QklM3af5wSswA-eMWYR2Lk54XYKHutXJurNV8wMIphYrR658H1mGHRFKs-e-ougf_-bl-lOuUVsOalMk7SyaOKyXOkZ9F2Dms0sNHsibFFFyUD7G_Jf37Q/s1600/telefondose_Einfachanschlussr_simple_elektrotechnik.jpg&quot; width=&quot;234&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;TAE Schaltbild&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Doppelanschlüsse:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Bei einem Doppelanschluss mit TAE NFF wird die erste Leitung an die obere Leiste und die zweite Leitung an die untere Leiste angeschlossen.&lt;/p&gt;
&lt;p&gt;Wenn Geräte an eine NFN-Dose angeschlossen sind, kann immer nur eines davon gleichzeitig genutzt werden. Wenn ein Gerät in eine N-Buchse gesteckt und aktiviert wird, werden die dahinterliegenden Geräte von der Leitung getrennt. Zum Beispiel, wenn ein herkömmliches Modem in der linken N-Buchse aktiv ist, sind die rechte N-Buchse und die F-Buchse abgeschaltet.&lt;/p&gt;
&lt;p&gt;Dasselbe gilt für die linke und mittlere Buchse einer NFF-Dose. Ein Modem in der N-Buchse kann das Telefon in der mittleren Buchse abschalten, aber nicht das in der rechten Buchse, da diese elektrisch unabhängig von den anderen beiden Buchsen ist.&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;b&gt;TAE Schaltbild&lt;/b&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiBfH6qhCpOys94P96vxskc2ByH-H63cDrvoz6RdFNL51L6O2Jmt1Xim4mq99pFyZEAumXG9KHA0iCsz74QvmNRwlfN0XSg332VtjWLu8dqjK6PnFigqGsyLRPq4ogima6T2iuK1_4rojCeI4440doV238_ZYr0eVoTO6fZxI3TqVcuX8tRMqNHL8kzNQ/s322/telefondose_Doppelanschluss_simple_elektrotechnik.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;322&quot; data-original-width=&quot;234&quot; height=&quot;218&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiBfH6qhCpOys94P96vxskc2ByH-H63cDrvoz6RdFNL51L6O2Jmt1Xim4mq99pFyZEAumXG9KHA0iCsz74QvmNRwlfN0XSg332VtjWLu8dqjK6PnFigqGsyLRPq4ogima6T2iuK1_4rojCeI4440doV238_ZYr0eVoTO6fZxI3TqVcuX8tRMqNHL8kzNQ/w159-h218/telefondose_Doppelanschluss_simple_elektrotechnik.gif&quot; width=&quot;159&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;p&gt;&lt;/p&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&amp;nbsp; &lt;br /&gt;&lt;/b&gt;&lt;/p&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;TAE-F Schaltbild&lt;/b&gt;&lt;/p&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&lt;/b&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;b&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjIZmkNKRdHPtT-pOLTRfqp0LONnfxaF7d0E7ZKqtusSjAQigcyFXatqyQbrEja4d_N2TGP9Ac9sb4yBPw177nUOKudwtRxXc3ki4jPa4Kk_4gks6qiKZzQII9cZRlKEjRl3dPHvUNVap8W72ASovb6NsO075GTlOZ0kuz-wpfgQn0bXL3su6hwjLh42g/s350/telefondose_taef_schaltbild_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;350&quot; data-original-width=&quot;317&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjIZmkNKRdHPtT-pOLTRfqp0LONnfxaF7d0E7ZKqtusSjAQigcyFXatqyQbrEja4d_N2TGP9Ac9sb4yBPw177nUOKudwtRxXc3ki4jPa4Kk_4gks6qiKZzQII9cZRlKEjRl3dPHvUNVap8W72ASovb6NsO075GTlOZ0kuz-wpfgQn0bXL3su6hwjLh42g/s320/telefondose_taef_schaltbild_simple_elektrotechnik.jpg&quot; width=&quot;290&quot; /&gt;&lt;/a&gt;&lt;/b&gt;&lt;/div&gt;&lt;p&gt;&lt;/p&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/p&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;TAE-NFF Schaltbild&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/b&gt;&lt;/p&gt;&lt;p&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt; &lt;br /&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi6kkOd5dFDLZkFErtIHZ06j34acdE150ICOl400yUz8EUzbgRdw7FFvbooPZjd7kt6xYI0i0IlT9l9a_zWt1p9QlwHLNlh_d83ewp_ksidR9r_LQln7KgWKTKHSL5trwf2Y49Z2MdsBt8k9iVX9X1m4X6SzQn19mDL8R1xaLef4F_aZDpF1EmV24QUog/s334/telefondose_TAE_NFF_schaltbild_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;334&quot; data-original-width=&quot;234&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi6kkOd5dFDLZkFErtIHZ06j34acdE150ICOl400yUz8EUzbgRdw7FFvbooPZjd7kt6xYI0i0IlT9l9a_zWt1p9QlwHLNlh_d83ewp_ksidR9r_LQln7KgWKTKHSL5trwf2Y49Z2MdsBt8k9iVX9X1m4X6SzQn19mDL8R1xaLef4F_aZDpF1EmV24QUog/s320/telefondose_TAE_NFF_schaltbild_simple_elektrotechnik.jpg&quot; width=&quot;224&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;TAE Dosenanlage&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;In einer TAE-Dosenanlage wird die ankommende Leitung auf die Klemmen 1 und 2 angeschlossen.&lt;/p&gt;
&lt;p&gt;Das weitere Aderpaar wird von 6 auf 1 und von 5 auf 2 gelegt.&lt;/p&gt;
&lt;p&gt;Es ist zu beachten, dass bei Verwendung eines F-codierten Geräts der Rest der Dosenanlage außer Betrieb genommen wird. Wenn eine Anlage sowohl mehrere N-Geräte als auch ein F-Gerät betrieben werden sollen, muss die TAE-F-Dose am Ende der Anlage angeschlossen werden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &lt;br /&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt; TAE-NFN Schaltbild&lt;/b&gt;&lt;/p&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;b&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjhO5gUCkJVSoFC2o0-7kxscKyqFt4woqWkY6G4ha_MCGx2UrGBArOB0Sa8Tg79jzfYZf0EI7RG-BafFHehVuQ60s9jkfXrmMj13yz6y4whciPx7VB4e5Yl90kB3Q-0s_3dr3lgbZDtf-UHH42Frr_hNNFdZlFVZhrpDCgVWAR9ZJ4pJmAwbFHFl4NdwQ/s350/telefondose_TAE-NFN_schaltbild_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;350&quot; data-original-width=&quot;316&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjhO5gUCkJVSoFC2o0-7kxscKyqFt4woqWkY6G4ha_MCGx2UrGBArOB0Sa8Tg79jzfYZf0EI7RG-BafFHehVuQ60s9jkfXrmMj13yz6y4whciPx7VB4e5Yl90kB3Q-0s_3dr3lgbZDtf-UHH42Frr_hNNFdZlFVZhrpDCgVWAR9ZJ4pJmAwbFHFl4NdwQ/s320/telefondose_TAE-NFN_schaltbild_simple_elektrotechnik.jpg&quot; width=&quot;289&quot; /&gt;&lt;/a&gt;&lt;/b&gt;&lt;/div&gt;&lt;b&gt;&lt;br /&gt;&lt;/b&gt;&lt;p&gt;&lt;/p&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;b&gt;Schaltung&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhzROu7LDur3BSgcNW1mZtIQzNVD6htjYYj081-mR8OKvtH4I-mmLqV5c6ydc0Bm58XEy1i3TiL3OcuUIcjZQFgSlMFcRXnewlEEqdnCMF1CGOk56JOE1bFlgrPf6_gpMKMb69_OODAIHVqvjLQyK4syJTMlM7MrS3p69eOWY-mxMy8clqqHeHFNLA7pA/s433/telefondose_TAE_Schaltung_simple_elektrotechnik.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;228&quot; data-original-width=&quot;433&quot; height=&quot;168&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhzROu7LDur3BSgcNW1mZtIQzNVD6htjYYj081-mR8OKvtH4I-mmLqV5c6ydc0Bm58XEy1i3TiL3OcuUIcjZQFgSlMFcRXnewlEEqdnCMF1CGOk56JOE1bFlgrPf6_gpMKMb69_OODAIHVqvjLQyK4syJTMlM7MrS3p69eOWY-mxMy8clqqHeHFNLA7pA/s320/telefondose_TAE_Schaltung_simple_elektrotechnik.gif&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/1547354890900283793/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/1547354890900283793' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1547354890900283793'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1547354890900283793'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/telefondosen-richtig-anschlieen.html' title='Telefondosen richtig anschließen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjYGbsGuv565-qCIpMR8ESzD_xb9GOWxCciXtwRl_5PG-ZW8q5uue8uTr3Aa4Sw3ZIexn24QklM3af5wSswA-eMWYR2Lk54XYKHutXJurNV8wMIphYrR658H1mGHRFKs-e-ougf_-bl-lOuUVsOalMk7SyaOKyXOkZ9F2Dms0sNHsibFFFyUD7G_Jf37Q/s72-c/telefondose_Einfachanschlussr_simple_elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-6444268756827440956</id><published>2023-06-13T10:54:00.000-07:00</published><updated>2023-06-13T10:54:59.073-07:00</updated><title type='text'>CEE - Steckdosen</title><content type='html'>&lt;h2&gt;Anleitung zum Einbau und Anschließen einer CEE Kraftsteckdose:&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjdmJ1VRfpjyTsIRshnBW7Ak6VJV3aWY-q7wiauCKqDx6H2AtVzupK1eY_5utLLnb1F_OkZMKS1ov_GlXjpR10Ko2m_U8YALTV7IvFOdhi9B1-MrF5lDzC25PtUwWnUvOivXuzSOqU2quXk7SQlHglpp-etekKXt_Xm8KJWEGf7GoMyDN9s03g3qs5OyA/s74/cee_kupplung_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;74&quot; data-original-width=&quot;61&quot; height=&quot;74&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjdmJ1VRfpjyTsIRshnBW7Ak6VJV3aWY-q7wiauCKqDx6H2AtVzupK1eY_5utLLnb1F_OkZMKS1ov_GlXjpR10Ko2m_U8YALTV7IvFOdhi9B1-MrF5lDzC25PtUwWnUvOivXuzSOqU2quXk7SQlHglpp-etekKXt_Xm8KJWEGf7GoMyDN9s03g3qs5OyA/s1600/cee_kupplung_simple_elektrotechnik.jpg&quot; width=&quot;61&quot; /&gt; &lt;br /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjn4-9Da0qCAb4Px7jgskMTT0uL7Vgx7PbxQORb7HVVpufNS1HVdoOv0Hucf7zyrtHSVNeJEFoMr4jw1tZbFokBsuyA-MAAwIw9OLNR0hd8I5AKfuD5LOKaJsthYFZ8p2r0WEmOTVgHkTNoghq7WGpbyUS7WwmGtqmxOmxFJagoRRwP208xO4PQYNI_Sg/s78/cee_stecker_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;69&quot; data-original-width=&quot;78&quot; height=&quot;69&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjn4-9Da0qCAb4Px7jgskMTT0uL7Vgx7PbxQORb7HVVpufNS1HVdoOv0Hucf7zyrtHSVNeJEFoMr4jw1tZbFokBsuyA-MAAwIw9OLNR0hd8I5AKfuD5LOKaJsthYFZ8p2r0WEmOTVgHkTNoghq7WGpbyUS7WwmGtqmxOmxFJagoRRwP208xO4PQYNI_Sg/s1600/cee_stecker_simple_elektrotechnik.jpg&quot; width=&quot;78&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;br /&gt;&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Planung:&lt;/b&gt;&lt;br /&gt; Wählen Sie den geeigneten Standort für die CEE Kraftsteckdose aus. Stellen Sie sicher, dass der Bereich ausreichend Platz bietet und vor Feuchtigkeit geschützt ist.&lt;br /&gt; Überprüfen Sie die Anforderungen und Vorschriften für die Installation einer CEE Kraftsteckdose in Ihrem Land und Ihrer Region.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Benötigte Werkzeuge und Materialien:&lt;/b&gt;&lt;br /&gt; CEE Kraftsteckdose (je nach Bedarf und Anforderungen: 16A, 32A, 63A usw.)&lt;br /&gt; Kabel (entsprechend der empfohlenen Größe und Spezifikation für den Stromkreis)&lt;br /&gt; Sicherungsautomat (geeignete Größe entsprechend der CEE Steckdose)&lt;br /&gt; Leitungsschutzschalter (RCD) (je nach Vorschriften und Sicherheitsstandards)&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Installation:&lt;/b&gt;&lt;br /&gt; Schalten Sie vor Beginn der Arbeiten den Strom ab, indem Sie den entsprechenden Sicherungsautomaten ausschalten.&lt;br /&gt; Wählen Sie eine passende Installationsmethode: Aufputz- oder Unterputzmontage. Beachten Sie die spezifischen Anweisungen für Ihre gewählte Methode.&lt;br /&gt; &lt;br /&gt;Montieren Sie die CEE Kraftsteckdose gemäß den Anweisungen des Herstellers. Stellen Sie sicher, dass alle Befestigungsschrauben ordnungsgemäß angezogen sind.&lt;br /&gt; Verbinden Sie das Kabel mit der CEE Steckdose: Entfernen Sie die äußere Isolierung des Kabels mit einer Abisolierzange, sodass die richtige Länge des Kupferleiters freigelegt wird. Schließen Sie die Kupferleiter an die entsprechenden Anschlussklemmen der CEE Steckdose an. Verwenden Sie geeignete Kabelschuhe oder Schraubklemmen, um eine sichere und zuverlässige Verbindung herzustellen.&lt;br /&gt; &lt;br /&gt;Stellen Sie sicher, dass das Kabel ordnungsgemäß befestigt ist und nicht durchhängt oder unter Spannung steht. Verwenden Sie bei Bedarf Kabelbinder, um das Kabel zu sichern.&lt;br /&gt; Installieren Sie den Sicherungsautomaten und den Leitungsschutzschalter (RCD) gemäß den Vorschriften und Sicherheitsstandards Ihres Landes. Diese Schutzvorrichtungen sorgen für eine sichere Absicherung des Stromkreises und schützen vor Überlastung und Fehlerströmen.&lt;br /&gt; Überprüfen Sie alle Verbindungen, um sicherzustellen, dass sie fest und sicher sind. Ziehen Sie alle Schraubklemmen ordnungsgemäß an, ohne sie zu überdrehen.&lt;br /&gt; Setzen Sie die Abdeckung der CEE Kraftsteckdose wieder auf und befestigen Sie sie gemäß den Anweisungen des Herstellers.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Abschluss:&lt;/b&gt;&lt;br /&gt; Schalten Sie den Stromkreis wieder ein und testen Sie die CEE Steckdose auf ihre Funktionalität.&lt;br /&gt; Verwenden Sie ein Messgerät, um die Spannung an der Steckdose zu überprüfen und sicherzustellen, dass sie den richtigen Wert aufweist.&lt;br /&gt; Überprüfen Sie, ob die CEE Steckdose ordnungsgemäß funktioniert, indem Sie ein geeignetes elektrisches Gerät anschließen und testen.&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;CEE-Drehstromsteckverbinder oder CEE-Steckvorrichtungen, auch bekannt als CEE-Stecker, werden verwendet, um Geräte mit Drehstrom zu verbinden. Sie sind in den Ausführungen 16 A, 32 A und 63 A erhältlich.&lt;/h5&gt;
&lt;p&gt;&lt;b&gt;Die Klemmen der CEE-Steckvorrichtungen sind wie folgt bezeichnet:&lt;/b&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;Schutzleiter (PE)&lt;br /&gt; Neutralleiter (N)&lt;br /&gt; Drei Außenleiter (L1, L2, L3)&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&amp;nbsp;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhThHwJOKVGn9LDC_wOuK9kMDPPA1Fi4ea0nmJvXaHvxS5VUELGp40QB4il4AaWf4UM5g-ugOe2uS3rDbdeFqNu851aXOxAnW_NfMoHm2eo4I99GcQoWPYNGiVW5VbPVz-MH5Q4CoZCikqit5mI7QYmRnqCjUuMVn366tm_ZUEMrxRzOEa30292fYrbOA/s500/cee%20belegung%20simple%20elektrrotechnik.png&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;200&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhThHwJOKVGn9LDC_wOuK9kMDPPA1Fi4ea0nmJvXaHvxS5VUELGp40QB4il4AaWf4UM5g-ugOe2uS3rDbdeFqNu851aXOxAnW_NfMoHm2eo4I99GcQoWPYNGiVW5VbPVz-MH5Q4CoZCikqit5mI7QYmRnqCjUuMVn366tm_ZUEMrxRzOEa30292fYrbOA/w200-h200/cee%20belegung%20simple%20elektrrotechnik.png&quot; width=&quot;200&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjXRiU2LXMcg5E8UXBTrXfnXc5FFmJ4Qy993Kyh8E5civUU-yclPwaszXwDjWVBE2LQ9FPSqBsBSWlzVN536lPHpDSP7ioN2eAynYDDyugNkGSwHAU4MNNH6uUUtuFv8AzTxWGjYxyaQesxQvKF5q_Rg8AiOaADhal1LMshWwwUWuNW5aCIdq_megrPPQ/s500/cee%20kupplung%20belegung%20simple%20elektrrotechnik.png&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;200&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjXRiU2LXMcg5E8UXBTrXfnXc5FFmJ4Qy993Kyh8E5civUU-yclPwaszXwDjWVBE2LQ9FPSqBsBSWlzVN536lPHpDSP7ioN2eAynYDDyugNkGSwHAU4MNNH6uUUtuFv8AzTxWGjYxyaQesxQvKF5q_Rg8AiOaADhal1LMshWwwUWuNW5aCIdq_megrPPQ/w200-h200/cee%20kupplung%20belegung%20simple%20elektrrotechnik.png&quot; width=&quot;200&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;br /&gt;&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Beim Anschließen eines CEE-Steckers oder einer CEE-Kupplung gehen Sie wie folgt vor:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Öffnen Sie den Stecker bzw. die Kupplung, um Zugang zu den Klemmen zu erhalten.&lt;/p&gt;
&lt;p&gt;Verbinden Sie das gelb-grüne Kabel mit der Klemme, die mit dem Erdungszeichen bzw. der Beschriftung &quot;PE&quot; gekennzeichnet ist. Dieses Kabel ist der Schutzleiter und dient zur Ableitung von Strom im Falle eines Fehlers.&lt;/p&gt;
&lt;p&gt;Schließen Sie das blaue Kabel an die Klemme mit der Beschriftung &quot;N&quot; an. Dieses Kabel ist der Neutralleiter und dient zur Rückführung des Stroms.&lt;/p&gt;
&lt;p&gt;Die Kabel in den Farben Schwarz, Braun und nochmals Schwarz werden jeweils an die Klemmen mit den Beschriftungen &quot;L1&quot;, &quot;L2&quot; und &quot;L3&quot; angeschlossen. Diese Kabel sind die Außenleiter und tragen den eigentlichen Strom.&lt;/p&gt;
&lt;p&gt;Beim CEE-Stecker ist der dickere Stift der PE (Schutzleiter). In der Regel folgen gegen den Uhrzeigersinn L1, L2, L3 und N (Neutralleiter).&lt;/p&gt;
&lt;p&gt;Bei der CEE-Kupplung ist das dickere Loch für den PE (Schutzleiter) vorgesehen. Im Uhrzeigersinn folgen L1, L2, L3 und N (Neutralleiter).&lt;/p&gt;
&lt;p&gt;Achten Sie beim Anschließen darauf, dass alle Kabel fest und sicher an den entsprechenden Klemmen befestigt sind. Überprüfen Sie die Verbindungen sorgfältig, um eine zuverlässige und sichere Stromübertragung zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Bitte beachten Sie, dass diese Informationen eine allgemeine Übersicht bieten und es wichtig ist, die spezifischen Vorschriften und Anweisungen Ihres Landes und Ihrer örtlichen Elektroinstallation zu beachten. Wenn Sie Zweifel haben oder sich unsicher fühlen, empfehle ich Ihnen, einen qualifizierten Elektriker hinzuzuziehen, um den Anschluss vorzunehmen. Ihre Sicherheit hat oberste Priorität.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/6444268756827440956/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/6444268756827440956' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/6444268756827440956'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/6444268756827440956'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/cee-steckdosen.html' title='CEE - Steckdosen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjdmJ1VRfpjyTsIRshnBW7Ak6VJV3aWY-q7wiauCKqDx6H2AtVzupK1eY_5utLLnb1F_OkZMKS1ov_GlXjpR10Ko2m_U8YALTV7IvFOdhi9B1-MrF5lDzC25PtUwWnUvOivXuzSOqU2quXk7SQlHglpp-etekKXt_Xm8KJWEGf7GoMyDN9s03g3qs5OyA/s72-c/cee_kupplung_simple_elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-577447991052645744</id><published>2023-06-13T10:52:00.000-07:00</published><updated>2023-06-13T10:52:24.683-07:00</updated><title type='text'>Anschluss von Lampen</title><content type='html'>&lt;h2 style=&quot;text-align: justify;&quot;&gt;Schritt-für-Schritt-Anleitung zur fachgerechten Installation von Lampen&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Bitte beachten Sie, dass bei elektrischen Arbeiten immer Vorsicht geboten ist. Wenn Sie unsicher sind, empfehle ich Ihnen, einen qualifizierten Elektriker zu kontaktieren.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhGdp3ptKcmW8Rk3viR2p8pgjy7kXK7BPtDtbjg29UBicqyL3xdCAfuJKike1FCdyRkEwCQG6JpAEpJGTgeSzRiIdp9zTIlhyA7IyrKv-mcQIpaBXG7z8WNwPLYA4wr5OsAjM7XFgipWuDkYxjVsePuvTix-Gy1wmItIzjTdPSdQXx6xtuJLMZMT3Egsg/s960/lampe%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;720&quot; data-original-width=&quot;960&quot; height=&quot;240&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhGdp3ptKcmW8Rk3viR2p8pgjy7kXK7BPtDtbjg29UBicqyL3xdCAfuJKike1FCdyRkEwCQG6JpAEpJGTgeSzRiIdp9zTIlhyA7IyrKv-mcQIpaBXG7z8WNwPLYA4wr5OsAjM7XFgipWuDkYxjVsePuvTix-Gy1wmItIzjTdPSdQXx6xtuJLMZMT3Egsg/s320/lampe%20simple%20elektrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 1: Vorbereitung&lt;/b&gt;&lt;br /&gt;Stellen Sie sicher, dass der Stromkreis, der die Deckenleuchte versorgt, ausgeschaltet ist. Gehen Sie zur Sicherheit zur Hauptsicherung und schalten Sie den entsprechenden Stromkreis ab. Überprüfen Sie mit einem Spannungsprüfer, ob kein Strom mehr anliegt, indem Sie den Spannungsprüfer in die Anschlussklemmen halten.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 2: Entfernen der alten Leuchte&lt;/b&gt;&lt;br /&gt;Wenn bereits eine Deckenleuchte installiert ist, entfernen Sie diese vorsichtig. Lösen Sie die Befestigungsschrauben oder -klammern und halten Sie die Leuchte fest, während Sie die Kabel lösen. Achten Sie darauf, dass die Kabel nicht mit Spannung stehen.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 3: Vorbereitung der neuen Leuchte&lt;/b&gt;&lt;br /&gt;Nehmen Sie die neue Deckenleuchte aus der Verpackung und überprüfen Sie, ob alle benötigten Teile vorhanden sind. Lesen Sie die mitgelieferte Anleitung sorgfältig durch, um sich mit den spezifischen Anweisungen der Leuchte vertraut zu machen.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 4: Montage der Deckenleuchte&lt;/b&gt;&lt;br /&gt;Befestigen Sie die Montagehalterung der Deckenleuchte an der Decke, indem Sie die mitgelieferten Schrauben und Dübel verwenden. Stellen Sie sicher, dass die Halterung fest und sicher an der Decke befestigt ist.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 5: Verkabelung&lt;/b&gt;&lt;br /&gt;Verbinden Sie die Drähte der Deckenleuchte mit den entsprechenden Drähten in der Decke. Üblicherweise sind die Kabel farbcodiert. Verbinden Sie den blauen Draht (Neutralleiter) der Leuchte mit dem blauen oder schwarzen Draht in der Decke. Verbinden Sie den braunen Draht (Phase) der Leuchte mit dem braunen oder roten Draht in der Decke. Verwenden Sie geeignete Verbindungsklemmen, um die Verbindungen sicher und isoliert zu halten. Stellen Sie sicher, dass die Kabel fest miteinander verbunden sind.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 6: Befestigung der Leuchte&lt;/b&gt;&lt;br /&gt;Befestigen Sie die Deckenleuchte an der Montagehalterung, indem Sie die mitgelieferten Schrauben oder Klammern verwenden. Stellen Sie sicher, dass die Leuchte fest und sicher angebracht ist.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 7: Abschlussarbeiten&lt;/b&gt;&lt;br /&gt;Überprüfen Sie alle Verbindungen und stellen Sie sicher, dass sie sicher und isoliert sind. Schließen Sie die Abdeckung der Leuchte, falls vorhanden. Schalten Sie dann den Stromkreis wieder ein, indem Sie zur Hauptsicherung gehen und den entsprechenden Schalter umlegen.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 8: Funktionsprüfung&lt;/b&gt;&lt;br /&gt;Schalten Sie den Lichtschalter ein und überprüfen Sie, ob die Deckenleuchte ordnungsgemäß funktioniert. Achten Sie auf eventuelle Flackern oder Probleme mit der Beleuchtung. Wenn alles einwandfrei funktioniert, haben Sie die Deckenleuchte erfolgreich montiert und angeschlossen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Bitte beachten Sie, dass diese Anleitung allgemein gehalten ist und je nach Leuchte und elektrischer Verkabelung variieren kann. Im Zweifelsfall sollten Sie immer die spezifischen Anweisungen des Herstellers befolgen oder einen Elektriker um Hilfe bitten. Sicherheit geht vor!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhTkBJdzVTSJsSw4MTXQ5eXhUYfrgItv8muGi-Na4QCeOUkXv7hyd59CDVWQTavyPvOZZ7-SluXjRVeUpRk1V31_k-81A50wKD3D7vKYfhvHlzQUXX4Tju_BC9_TLUx53v-XXapI_61f1orw2XummPeNKFflVAPMxC9cR_PIt8sPTpTAPx7xrgJ1g9zHQ/s2000/lampenanschluss%20simple%20elektrotechnik.jpeg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;1189&quot; data-original-width=&quot;2000&quot; height=&quot;238&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhTkBJdzVTSJsSw4MTXQ5eXhUYfrgItv8muGi-Na4QCeOUkXv7hyd59CDVWQTavyPvOZZ7-SluXjRVeUpRk1V31_k-81A50wKD3D7vKYfhvHlzQUXX4Tju_BC9_TLUx53v-XXapI_61f1orw2XummPeNKFflVAPMxC9cR_PIt8sPTpTAPx7xrgJ1g9zHQ/w400-h238/lampenanschluss%20simple%20elektrotechnik.jpeg&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Prinzipiell sollte bei Ihrem Decken- bzw. Wandauslass ein 3-poliges Kabel vorhanden sein (Schwarz, Blau, Grün-Gelb). Bei älteren Gebäuden können jedoch andere Farben verwendet worden sein (Schwarz = Grün, Blau = Grau, Grün-Gelb = Rot).&lt;/p&gt;
&lt;p&gt;Schwarz sollte an der Lampe mit der Klemme L (P) verbunden werden.&lt;br /&gt;Blau sollte an die Klemme (N) angeschlossen werden.&lt;br /&gt;Grün-Gelb sollte an die Klemme mit dem Erdungssymbol (PE) angeschlossen werden.&lt;/p&gt;
&lt;p&gt;Falls Ihnen nur 2 Drähte zur Verfügung stehen, zum Beispiel Schwarz und Blau, müssen Sie unbedingt die Klemmen N und PE an der Lampe miteinander verbinden. Dadurch wird sichergestellt, dass das Gehäuse Ihrer Lampe geschützt ist und Sie keinen Stromschlag bekommen, wenn Sie sie berühren und ein Fehler in der Lampe auftritt.&lt;/p&gt;
&lt;p&gt;Es kann auch vorkommen, dass eine Lampe nur 2 Anschlussklemmen hat, nämlich L und N. In diesem Fall sollte es sich jedoch um eine Lampe handeln, die vollständig aus Kunststoff oder ähnlichem Material besteht. Falls nicht, sollte irgendwo eine Klemme für die Erdung vorhanden sein.&lt;/p&gt;
&lt;p&gt;Falls tatsächlich keine Erdungsklemme vorhanden ist, müssen Sie die Lampe nicht erden. Sie können den grün-gelben Draht dann einfach isolieren.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/577447991052645744/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/577447991052645744' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/577447991052645744'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/577447991052645744'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2006/12/lampen-und-ventilatoren.html' title='Anschluss von Lampen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhGdp3ptKcmW8Rk3viR2p8pgjy7kXK7BPtDtbjg29UBicqyL3xdCAfuJKike1FCdyRkEwCQG6JpAEpJGTgeSzRiIdp9zTIlhyA7IyrKv-mcQIpaBXG7z8WNwPLYA4wr5OsAjM7XFgipWuDkYxjVsePuvTix-Gy1wmItIzjTdPSdQXx6xtuJLMZMT3Egsg/s72-c/lampe%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-8734747051108371264</id><published>2023-06-13T10:50:00.002-07:00</published><updated>2023-06-13T10:50:26.127-07:00</updated><title type='text'>Stecker / Kupplung anschliessen</title><content type='html'>&lt;h2&gt;Beispiel für den Anschluss einer Typ-13-Kupplung:&lt;/h2&gt;
&lt;p&gt;Stecker und Kupplungen sollten ausschließlich mit flexiblen Leitungen verbunden werden, da sie mobil sind und nicht fest installiert werden. Andernfalls besteht die Gefahr, dass die starren Drähte durch die ständigen Bewegungen des Kabels und Steckers brüchig werden und abbrechen können.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 1:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiG0E7QiOkapkJfQGBfnbvKyl-Jdah386sXr1O2I8SVxlsxq7VjGSLTSBwMTl7OAD4f8hFs38fMax5C4kmw1-qdFqTlIlaBuMSZcA9eT49STLLN2BPWlsymD7fpYncOJap37_-Zbouynf2B8t1HZ4BVyKvT6zrsUpfWKJiYBw0xaBdJ_GZHy1DGTWj5Hg/s500/t12%20anschluss%20ohne%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiG0E7QiOkapkJfQGBfnbvKyl-Jdah386sXr1O2I8SVxlsxq7VjGSLTSBwMTl7OAD4f8hFs38fMax5C4kmw1-qdFqTlIlaBuMSZcA9eT49STLLN2BPWlsymD7fpYncOJap37_-Zbouynf2B8t1HZ4BVyKvT6zrsUpfWKJiYBw0xaBdJ_GZHy1DGTWj5Hg/s320/t12%20anschluss%20ohne%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Um eine saubere Verbindung herzustellen, werden folgende Komponenten benötigt:&lt;/p&gt;
&lt;p&gt;Flexibles Kabel mit ausreichendem Querschnitt, abhängig von der Absicherung oder Belastung.&lt;br /&gt;Kupplung Typ 13 oder Eurostecker-Kupplung, je nach Anforderung.&lt;br /&gt;Aderendhülsen für die flexiblen Drähte, um eine sichere und stabile Verbindung herzustellen.&lt;/p&gt;
&lt;p&gt;Durch die Verwendung eines flexiblen Kabels mit dem richtigen Querschnitt wird gewährleistet, dass die elektrische Last sicher transportiert wird. Die passende Kupplung sorgt dafür, dass der Stecker ordnungsgemäß angeschlossen werden kann. Aderendhülsen wiederum dienen dazu, die flexiblen Drähte zu schützen und eine zuverlässige Verbindung herzustellen. Mit diesen Komponenten kann ein sauberer und sicherer Anschluss hergestellt werden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 2:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiqNXelmU-CBh2jQhlgmt54Vr4q7HeeccK4pmZQpbuAOdeFCGxEC5MBl58f9gNARF4y70aiiXYefBKRZ7Abp43LEsaKfz05XQZC5u6YgfCo9jhTRDwEKQ-Wdw8qt4qTOEemKZZxNBuAdn9jwSPU3daXpcuZoE_WzpMBaaofl4zys6Gs5pr2Dw-ZurTEXg/s500/t12%20anschluss%20offen%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiqNXelmU-CBh2jQhlgmt54Vr4q7HeeccK4pmZQpbuAOdeFCGxEC5MBl58f9gNARF4y70aiiXYefBKRZ7Abp43LEsaKfz05XQZC5u6YgfCo9jhTRDwEKQ-Wdw8qt4qTOEemKZZxNBuAdn9jwSPU3daXpcuZoE_WzpMBaaofl4zys6Gs5pr2Dw-ZurTEXg/s320/t12%20anschluss%20offen%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Um die Abdeckung der Kupplung zu öffnen, suchen Sie auf der Oberseite nach einer Schraube. Diese Schraube dient dazu, die Kupplung zu öffnen.&lt;/p&gt;
&lt;p&gt;Nachdem Sie die Abdeckung geöffnet haben, werden Sie die Anschlussklemmen und die Zugentlastung sehen. Die Zugentlastung ist dafür verantwortlich, das Kabel später sicher zu fixieren.&lt;/p&gt;
&lt;p&gt;Um das Kabel richtig vorzubereiten, müssen Sie es abisolieren. Dabei entfernen Sie vorsichtig den äußeren Mantel des Kabels, sodass die darunter liegenden Drähte freigelegt werden. Stellen Sie sicher, dass die Drähte lang genug sind, um von der Zugentlastung bis zu den Anschlussklemmen reichen zu können.&lt;/p&gt;
&lt;p&gt;Achten Sie darauf, dass die abisolierten Drähte sauber und frei von Beschädigungen sind. Sie können die einzelnen Drähte gegebenenfalls auch noch etwas gerade biegen, um eine bessere Anschlussmöglichkeit zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Sobald die Drähte abisoliert sind und lang genug bis zu den Anschlussklemmen reichen, sind Sie bereit, das Kabel an die Kupplung anzuschließen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&amp;nbsp;Schritt 3:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEic4gN-tk6KXZY-Dy6L3jj7l1TvbgD4DaWx2Ko2f9d1AVimY8x_pP0TDUe3yZBq8NKM7Dfu00fFx4sK4k1xKwB5r24ROMS4nNx_KJVb_b7kMMc40OE_SsFncOKNiGIv_oRo5bvxKNDTixYbWJEPr95F3llGPu-_IZe2wQH_Y-3hIOCQ5pHnihyQovqZDQ/s500/t12%20anschluss%20zugentlastung%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEic4gN-tk6KXZY-Dy6L3jj7l1TvbgD4DaWx2Ko2f9d1AVimY8x_pP0TDUe3yZBq8NKM7Dfu00fFx4sK4k1xKwB5r24ROMS4nNx_KJVb_b7kMMc40OE_SsFncOKNiGIv_oRo5bvxKNDTixYbWJEPr95F3llGPu-_IZe2wQH_Y-3hIOCQ5pHnihyQovqZDQ/s320/t12%20anschluss%20zugentlastung%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Als nächstes sollten Sie die Schrauben der Zugentlastung öffnen. In der Regel genügt es, wenn Sie eine der Schrauben großzügig lockern, während Sie die zweite Schraube komplett entfernen. Dadurch erhalten Sie genügend Spielraum, um das Kabel einzuführen.&lt;/p&gt;
&lt;p&gt;Bitte beachten Sie, dass der genaue Aufbau der Zugentlastung je nach Kupplungsmodell variieren kann. Stellen Sie sicher, dass Sie die entsprechenden Schrauben identifizieren und entsprechend lösen, um das Kabel korrekt einzuführen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&amp;nbsp;Schritt 4:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgUqbwDi29AHkv-CKTME9cdz8DPmhM1OyjtzDNklXf12XfCtfmGDv-VBdYTnLDxEUXin05YhibhSj2IguSSdlJXdS3fw27mSnwiyaqtGoo0N0jv5cm98HWAjAGaa6fkiUNiffjdtXTRL-Y6Tln7lGbinsgDeQ3LIZGXkRnWuyVAGkuqSrg8NZxdd60oKw/s500/t12%20anschluss%20aderendhuelse%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgUqbwDi29AHkv-CKTME9cdz8DPmhM1OyjtzDNklXf12XfCtfmGDv-VBdYTnLDxEUXin05YhibhSj2IguSSdlJXdS3fw27mSnwiyaqtGoo0N0jv5cm98HWAjAGaa6fkiUNiffjdtXTRL-Y6Tln7lGbinsgDeQ3LIZGXkRnWuyVAGkuqSrg8NZxdd60oKw/s320/t12%20anschluss%20aderendhuelse%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Beim Abisolieren der einzelnen Drähte des Kabels ist es wichtig, auf eine besondere Anordnung zu achten. Der Schutzleiter-Draht, auch bekannt als Erdungsdraht, sollte etwas länger als die anderen Drähte abisoliert werden.&lt;/p&gt;
&lt;p&gt;Diese Maßnahme dient der Sicherheit, da der Schutzleiter eine wichtige Schutzfunktion übernimmt. Sollte das Kabel einmal von der Zugentlastung gelöst werden oder das Kabel herausgerissen werden, bleibt der Schutzleiter bis zum Schluss mit dem Anschlusspunkt verbunden. Dadurch wird sichergestellt, dass im Falle eines Defekts oder eines Kurzschlusses die elektrische Spannung sicher abgeleitet wird und keine Gefahr für Personen besteht.&lt;/p&gt;
&lt;p&gt;Beim Abisolieren der Drähte ist es wichtig, saubere und gleichmäßige Abisolierungen vorzunehmen, um eine gute Kontaktfläche zu gewährleisten. Achten Sie darauf, dass die abisolierten Drähte frei von Beschädigungen oder Verdrillungen sind, um eine ordnungsgemäße Verbindung herstellen zu können.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&amp;nbsp;Schritt 5:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgHfU8raiv0AA3aYaxtk4pzdqTnr1o9nO4oogEjw1PBP5HFLopnhNDXn1-WnUWvgkz5aoTlsCegiXBovqEG45Sso5gbsLt1pnMNfv1YqnjAuGnJK-QkOuBDt5kHE7WX-ek1wbi-mDnZXfiiPVuzoKB6IgKdDYPAl99BfEFCJzTTG4oMqR6V35htyvpV_Q/s500/t12%20anschluss%20aderendhuelse%20gepresst%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgHfU8raiv0AA3aYaxtk4pzdqTnr1o9nO4oogEjw1PBP5HFLopnhNDXn1-WnUWvgkz5aoTlsCegiXBovqEG45Sso5gbsLt1pnMNfv1YqnjAuGnJK-QkOuBDt5kHE7WX-ek1wbi-mDnZXfiiPVuzoKB6IgKdDYPAl99BfEFCJzTTG4oMqR6V35htyvpV_Q/s320/t12%20anschluss%20aderendhuelse%20gepresst%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Die Drähte sollten entsprechend der Länge der Aderendhülse abisoliert werden. In diesem Fall beträgt die Länge etwa 8 mm.&lt;/p&gt;
&lt;p&gt;Nachdem Sie die Drähte abisoliert haben, ist es wichtig, die Aderendhülsen auf die Drahtenden zu stecken. Achten Sie dabei darauf, dass keine Drahtlitzen herausstehen. Das Vorstehen von Drahtlitzen kann später zu Fehlfunktionen oder sogar einem Kurzschluss führen.&lt;/p&gt;
&lt;p&gt;Um die Aderendhülsen sicher und zuverlässig zu befestigen, verwenden Sie ein geeignetes Werkzeug wie eine Presszange für Aderendhülsen. Platzieren Sie die Aderendhülse in der Presszange und drücken Sie sie fest auf das Drahtende. Durch den Druck wird die Aderendhülse mit dem Draht verbunden und bildet eine sichere und stabile Verbindung.&lt;/p&gt;
&lt;p&gt;Achten Sie darauf, dass die Aderendhülse ordnungsgemäß gepresst ist und eine feste Verbindung mit dem Draht herstellt. Überprüfen Sie visuell, ob die Aderendhülse korrekt befestigt ist und sich nicht leicht lösen lässt.&lt;/p&gt;
&lt;p&gt;Durch diese Schritte stellen Sie sicher, dass die Verbindung zwischen den Drähten und den Anschlussklemmen stabil, sicher und zuverlässig ist.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&amp;nbsp;Schritt 6:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjKP4ApyUmzPpSdz7HGVGXnBZF0l2TGuqqtWxJ0cgIVpk6lKTlNpvc0rRZzsqSUv_4l8zLfWpLCjupt8-LmisaylSj7SIe6QlAT71gBkH1KQDMGl4TycG3-9uIHCK1V7WI1X2FmTuSxkCo6zgMSd8ID1z7FLpgVK-l1pkpDuFTniN0NxhCIs-txEOLfIA/s500/t12%20anschluss%20anschlussgepresst%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjKP4ApyUmzPpSdz7HGVGXnBZF0l2TGuqqtWxJ0cgIVpk6lKTlNpvc0rRZzsqSUv_4l8zLfWpLCjupt8-LmisaylSj7SIe6QlAT71gBkH1KQDMGl4TycG3-9uIHCK1V7WI1X2FmTuSxkCo6zgMSd8ID1z7FLpgVK-l1pkpDuFTniN0NxhCIs-txEOLfIA/s320/t12%20anschluss%20anschlussgepresst%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Bevor Sie die einzelnen Drähte anschließen, überprüfen Sie bitte, ob Sie bereits die Abdeckung der Kupplung durch das Kabel gefädelt haben. Es ist wichtig, dies zu tun, bevor Sie die Drähte anschließen, da es sonst erforderlich sein kann, alles wieder zu lösen und von vorne zu beginnen.&lt;/p&gt;
&lt;p&gt;Sobald die Abdeckung durch das Kabel gefädelt ist, führen Sie die Aderendhülsen vollständig in die entsprechenden Anschlussklemmen ein. Stellen Sie sicher, dass keine blanken Kupferstellen der Aderendhülse mehr sichtbar sind. Dies gewährleistet eine sichere und zuverlässige Verbindung.&lt;/p&gt;
&lt;p&gt;Je nach Art der Anschlussklemme kann es sein, dass die Aderendhülsen möglicherweise eingekürzt werden müssen, wenn sie nicht vollständig in die Klemme passen. In diesem Fall sollten Sie die Aderendhülsen entsprechend kürzen, um sicherzustellen, dass sie ordnungsgemäß sitzen und einen guten Kontakt herstellen.&lt;/p&gt;
&lt;p&gt;Die Anschlussbelegung der Adern für die Typ-13-Kupplung ist mit L (für den Außenleiter) und N (für den Neutralleiter) beschriftet. Der Schutzleiterkontakt befindet sich in der Mitte. Achten Sie darauf, dass Sie die Drähte gemäß dieser Belegung anschließen, um die korrekte Funktionalität und Sicherheit zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Nachdem Sie die Drähte entsprechend angeschlossen haben, können Sie die Kupplung wieder schließen und sicherstellen, dass alle Verbindungen fest und sicher sitzen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&amp;nbsp;Schritt 7:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEivvFwUiM_sJpNFPhdE0L3XqVV6DutktbNr2l6L3Mveb7NyvEkUTqOVvfjCJcsxPu9rBka8DHWavJHGr54pXDNiTQXaytyf0OeRPaxIKAcCleSA-ir2QvccnuQvqEj8vH9SIfvNCB6qQN3fWNSNaKBddmNtZt-7rlhTSQQb94Z5XuL50cw6v0fgh6B4MQ/s500/t12%20anschluss%20angeschlossen%20zugentlastung%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEivvFwUiM_sJpNFPhdE0L3XqVV6DutktbNr2l6L3Mveb7NyvEkUTqOVvfjCJcsxPu9rBka8DHWavJHGr54pXDNiTQXaytyf0OeRPaxIKAcCleSA-ir2QvccnuQvqEj8vH9SIfvNCB6qQN3fWNSNaKBddmNtZt-7rlhTSQQb94Z5XuL50cw6v0fgh6B4MQ/s320/t12%20anschluss%20angeschlossen%20zugentlastung%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Der Schutzleiter-Draht sollte nun am längsten sein, um sicherzustellen, dass die Schutzleiter-Verbindung bis zum Schluss bestehen bleibt, selbst wenn das Kabel gelöst oder herausgerissen wird.&lt;/p&gt;
&lt;p&gt;Nun können Sie das Kabel an der Zugentlastung fixieren. Achten Sie dabei darauf, dass der Kabelmantel vollständig über die Zugentlastung geschoben wird und bis in die Kupplung eingeführt wird. Dadurch wird der Kabelmantel stabilisiert und fixiert.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, den Kabelmantel komplett über die Zugentlastung zu schieben, um eine ordnungsgemäße Fixierung und Zugentlastung zu gewährleisten. Dadurch wird verhindert, dass Zugkräfte direkt auf die Drahtverbindungen wirken, was zu Beschädigungen oder Unterbrechungen führen könnte.&lt;/p&gt;
&lt;p&gt;Stellen Sie sicher, dass die Zugentlastung fest und sicher sitzt, um das Kabel zu sichern und Spannungen oder Belastungen zu minimieren. Überprüfen Sie abschließend visuell, ob der Kabelmantel vollständig in die Kupplung eingeführt und sicher fixiert ist.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&amp;nbsp;Schritt 8:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEifjXxRkT68xuRd_nnWWm_nDLUp-e2RMhAPs6jEX6a4xwq3E5l-Zey2fmgh594avSPr3MR_96kSp3r3zZU-A3YIpWO8Wno1L3c44MyRDRIS_ne4egHBPQdrjYGeBB6MFw512bSiwNrOndGTqa_sVCUO_6adYXFzJQzvxpGSZ5SXYPqdmNHLEekfA0r80w/s500/t12%20anschluss%20angeschlossen%20schliessen%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEifjXxRkT68xuRd_nnWWm_nDLUp-e2RMhAPs6jEX6a4xwq3E5l-Zey2fmgh594avSPr3MR_96kSp3r3zZU-A3YIpWO8Wno1L3c44MyRDRIS_ne4egHBPQdrjYGeBB6MFw512bSiwNrOndGTqa_sVCUO_6adYXFzJQzvxpGSZ5SXYPqdmNHLEekfA0r80w/s320/t12%20anschluss%20angeschlossen%20schliessen%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Jetzt können Sie die Abdeckung der Kupplung wieder schließen. Achten Sie darauf, die Abdeckung mit der richtigen Ober- oder Unterseite über den Anschlusssockel zu platzieren.&lt;/p&gt;
&lt;p&gt;Während Sie die Abdeckung schließen, ist es wichtig, darauf zu achten, dass keine Drähte eingeklemmt oder verletzt werden. Überprüfen Sie sorgfältig, ob die Drähte frei und unbehindert sind, bevor Sie die Abdeckung vollständig schließen.&lt;/p&gt;
&lt;p&gt;Nachdem Sie die Abdeckung richtig positioniert haben, können Sie die entsprechenden Schrauben verwenden, um die Abdeckung zu befestigen. Ziehen Sie die Schrauben fest, jedoch nicht übermäßig, um Beschädigungen zu vermeiden.&lt;/p&gt;
&lt;p&gt;Während des Verschließens der Abdeckung sollten Sie darauf achten, dass die Verbindung zwischen den Drähten und den Anschlussklemmen weiterhin stabil ist und keine Lockerheit oder Verschiebung auftritt.&lt;/p&gt;
&lt;p&gt;Sobald die Abdeckung ordnungsgemäß verschlossen ist, überprüfen Sie noch einmal visuell, ob alle Komponenten sicher und richtig verbunden sind, und dass die Drähte nicht eingeklemmt oder beschädigt wurden. Dadurch stellen Sie sicher, dass die Kupplung ordnungsgemäß und sicher installiert ist.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;&amp;nbsp;Schritt 9:&lt;/b&gt;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2M-ObQrsCxpSaODIsApeOl5Mpcf4fPjqwXuWj-Jk0zw6W4jqMHRMuskeSFYKMMiydOLnbs1u-qQwQk3t_ttb4mVPujffh8jqwir_Y6L-OinBqHoSaWrPflDTn0mejLogLiuUgCu-0AqA3sIMKNYZeB4kf-bq2HiE0aBVVewrI-bvMp4tLY-ycksm7hw/s500/t12%20anschluss%20fertig%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2M-ObQrsCxpSaODIsApeOl5Mpcf4fPjqwXuWj-Jk0zw6W4jqMHRMuskeSFYKMMiydOLnbs1u-qQwQk3t_ttb4mVPujffh8jqwir_Y6L-OinBqHoSaWrPflDTn0mejLogLiuUgCu-0AqA3sIMKNYZeB4kf-bq2HiE0aBVVewrI-bvMp4tLY-ycksm7hw/s320/t12%20anschluss%20fertig%20simple%20elektrrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Nachdem die Kupplung fertig angeschlossen ist, ist es wichtig, eine gründliche Kontrolle durchzuführen, bevor sie zum ersten Mal verwendet wird. &lt;br /&gt;Hier sind die Schritte für die Kontrolle:&lt;/p&gt;
&lt;p&gt;Optische Kontrolle: Überprüfen Sie visuell alle Verbindungen, Kabel und Komponenten, um sicherzustellen, dass keine offensichtlichen Defekte, Beschädigungen oder lose Teile vorhanden sind. Achten Sie besonders auf die korrekte Platzierung der Abdeckung und das Einführen des Kabelmantels in die Zugentlastung.&lt;/p&gt;
&lt;p&gt;Mechanische Kontrolle: Überprüfen Sie die Zugentlastung, um sicherzustellen, dass das Kabel sicher fixiert ist und Zugkräften standhalten kann. Stellen Sie sicher, dass die Zugentlastung nicht gelockert ist und das Kabel fest an Ort und Stelle hält.&lt;/p&gt;
&lt;p&gt;Messung der Polarität: Verwenden Sie ein geeignetes Messgerät, um die Polarität der Kupplung zu überprüfen. Prüfen Sie, ob der Schutzleiter (PE), der Außenleiter (L) und der Neutralleiter (N) an den entsprechenden Buchsen angeschlossen sind. Eine falsche Polarität kann zu schwerwiegenden Fehlern führen und sollte unbedingt vermieden werden.&lt;/p&gt;
&lt;p&gt;Führen Sie die Messung sorgfältig durch und vergewissern Sie sich, dass die Polarität korrekt ist, bevor Sie die Kupplung zum ersten Mal verwenden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Beispiel für den Anschluss eines Typ 23 Steckers&lt;/h5&gt;
&lt;p&gt;Die vorgehensweise entspricht derselben wie in dem Beispiel oben gezeigt.&lt;/p&gt;
&lt;table style=&quot;background-color: #e2eaee; box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiI2tk8txQLYCmUHUuWgahJHF9ahkLrwpyrMh7Wk3FM4kdSJO5tLV2F4IvLeaeaIOMFWNsyHPe0jE-EaJBCxME5HamtESSgkfXvaPcAEZ7ybwYfMxetzvBWV0HP8s-vqYnlrtXtv8iJBByuWfoXZx1r9XBpkHmmrep2-CuWrQVfAW74qbyXA_Ntkm87fA/s500/T13%20stecker%20anschluss%20ohne%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;145&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiI2tk8txQLYCmUHUuWgahJHF9ahkLrwpyrMh7Wk3FM4kdSJO5tLV2F4IvLeaeaIOMFWNsyHPe0jE-EaJBCxME5HamtESSgkfXvaPcAEZ7ybwYfMxetzvBWV0HP8s-vqYnlrtXtv8iJBByuWfoXZx1r9XBpkHmmrep2-CuWrQVfAW74qbyXA_Ntkm87fA/w145-h145/T13%20stecker%20anschluss%20ohne%20simple%20elektrrotechnik.jpg&quot; width=&quot;145&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieNTwS4v72te1E8Wb-s_VNEhIRTxOiuP0GlDhooGXSfLcwae3ikayezZdR-necI1CO2DbGdQjMzVBEd9AwCj62TLiqklM8VfMQw2SOoaFpoEjHyHUaPwocV-aMvB-pPm8NEyERdDlwpqEYpAqMg8yyk1HDge8uLhyB8wYvfRVa_jPNt6LBKLKi4-3XaA/s500/T13%20stecker%20anschluss%20geoeffnet%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;151&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieNTwS4v72te1E8Wb-s_VNEhIRTxOiuP0GlDhooGXSfLcwae3ikayezZdR-necI1CO2DbGdQjMzVBEd9AwCj62TLiqklM8VfMQw2SOoaFpoEjHyHUaPwocV-aMvB-pPm8NEyERdDlwpqEYpAqMg8yyk1HDge8uLhyB8wYvfRVa_jPNt6LBKLKi4-3XaA/w151-h151/T13%20stecker%20anschluss%20geoeffnet%20simple%20elektrrotechnik.jpg&quot; width=&quot;151&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiSY3wfEQyhfkE30uR7gPwMpV168kicASmadQ0QMrkr6vjBW39m8YtczbRo_si42rh1-B-Oqyy2Z9sOYi5JbmDTRxL44ckOmoxF7ajl2VcHAHkEAzM0Kb-tAvOf4Of8teGCysfpcFJOb0--DdCBIbqnbtnJrZlUvTi55xbkrgeTHk9BEBGZcO4_AAH2Pg/s500/T13%20stecker%20anschluss%20angeschlossen%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;149&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiSY3wfEQyhfkE30uR7gPwMpV168kicASmadQ0QMrkr6vjBW39m8YtczbRo_si42rh1-B-Oqyy2Z9sOYi5JbmDTRxL44ckOmoxF7ajl2VcHAHkEAzM0Kb-tAvOf4Of8teGCysfpcFJOb0--DdCBIbqnbtnJrZlUvTi55xbkrgeTHk9BEBGZcO4_AAH2Pg/w149-h149/T13%20stecker%20anschluss%20angeschlossen%20simple%20elektrrotechnik.jpg&quot; width=&quot;149&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjtck82h12SbSFxMJq1pcnEtpPbde5X0aiAmP6cv2VpsaKmHBXKjSrFIDYV0VAxO6gKEQch36YlVAWhWK41tEQuqsyKl1kuhwd7Lc_NwbiSQqR77WdnzeALpeZBpEcg9AoaziTyzOcDdfAb74i06xHAkBQJFzG-T5qKFm79EWN7DrtjYWNqX-WyQpYcVg/s500/T13%20stecker%20anschluss%20fertig%20simple%20elektrrotechnik.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;153&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjtck82h12SbSFxMJq1pcnEtpPbde5X0aiAmP6cv2VpsaKmHBXKjSrFIDYV0VAxO6gKEQch36YlVAWhWK41tEQuqsyKl1kuhwd7Lc_NwbiSQqR77WdnzeALpeZBpEcg9AoaziTyzOcDdfAb74i06xHAkBQJFzG-T5qKFm79EWN7DrtjYWNqX-WyQpYcVg/w153-h153/T13%20stecker%20anschluss%20fertig%20simple%20elektrrotechnik.jpg&quot; width=&quot;153&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&amp;nbsp;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Beispiel für den Anschluss einer Steckerleiste&lt;/h5&gt;
&lt;p&gt;hierbei ist zu beachten, wie man im Bild erkennt, wird hier ein starres Kabel verwendet. Dies ist zulässig, wenn das Kabel fest verlegt und die Steckerleiste montiert wird.&lt;/p&gt;
&lt;table style=&quot;background-color: #e2eaee; box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&amp;nbsp;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEigVMRMdTkIVzz8JgUBua_l_oXqXOsHpotcKnM48hzhxjOZrqDKNIIqJWsfPYytmsPyPcmZrCg6FoHH3LtzuaDOFJTbca2yxnLhuLJ29DHlDnZ7GbjUq2AevQPHgWgA--R2pArzYjuLzgflvE0bzRrrDaQWecX7QIgdmV4MBvj6mAf89K4asTwLx6Fz9w/s500/steckdosenleiste%20anschluss%20ohne%20simple%20elektrrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;148&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEigVMRMdTkIVzz8JgUBua_l_oXqXOsHpotcKnM48hzhxjOZrqDKNIIqJWsfPYytmsPyPcmZrCg6FoHH3LtzuaDOFJTbca2yxnLhuLJ29DHlDnZ7GbjUq2AevQPHgWgA--R2pArzYjuLzgflvE0bzRrrDaQWecX7QIgdmV4MBvj6mAf89K4asTwLx6Fz9w/w148-h148/steckdosenleiste%20anschluss%20ohne%20simple%20elektrrotechnik.jpg&quot; width=&quot;148&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;/td&gt;
&lt;td&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg4DAHdYFBZ75hCv2q0IN7XlUx9kzBpU-ya6NXz5qvSp56SwVsQD0vGu3MSgCyn8Cy6wcfsgrH2OPeWN2x-5xMkvR_BjHkLyPAZNAJZxWMWKMDuF0Lm8HF26wqTdUYlrCbbQ8ogRfgpkgYATVbV5S96q4NjsJwUkY-8O5r3uU4CS8DVLEnosvJnTz7HEQ/s500/steckdosenleiste%20anschluss%20angeschlossen%20simple%20elektrrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;147&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg4DAHdYFBZ75hCv2q0IN7XlUx9kzBpU-ya6NXz5qvSp56SwVsQD0vGu3MSgCyn8Cy6wcfsgrH2OPeWN2x-5xMkvR_BjHkLyPAZNAJZxWMWKMDuF0Lm8HF26wqTdUYlrCbbQ8ogRfgpkgYATVbV5S96q4NjsJwUkY-8O5r3uU4CS8DVLEnosvJnTz7HEQ/w147-h147/steckdosenleiste%20anschluss%20angeschlossen%20simple%20elektrrotechnik.jpg&quot; width=&quot;147&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiAvvw349JH_4pbahsHYl0tkFN02F51jRrR-LN0LkDJS1PdSrsPSg6Q11U1dfGVwEuphlEGl72vf9kHbce2-lxH8ILtvB52p2Jqx5tVBqeDvLCpX5d7MuYUii9kKDBxU-MFWKvZjsYxZF6C_JGoM8xxcUpZFJE9ldiMBzbW63kN8B_PyNQJ3eFCgto08g/s500/steckdosenleiste%20anschluss%20angeschlossen%20detail%20simple%20elektrrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;150&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiAvvw349JH_4pbahsHYl0tkFN02F51jRrR-LN0LkDJS1PdSrsPSg6Q11U1dfGVwEuphlEGl72vf9kHbce2-lxH8ILtvB52p2Jqx5tVBqeDvLCpX5d7MuYUii9kKDBxU-MFWKvZjsYxZF6C_JGoM8xxcUpZFJE9ldiMBzbW63kN8B_PyNQJ3eFCgto08g/w150-h150/steckdosenleiste%20anschluss%20angeschlossen%20detail%20simple%20elektrrotechnik.jpg&quot; width=&quot;150&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhDvP-yjG1eFJJb0KxrKeJuHYgxjGUgAJ9VvbnFQ741ktRifogErUPFwllmS8bIPKISibcxYkATLJDx8qIsKKtZDuurwXy9luYrEj0iaWR5aWTQdVf0FttUdaUquH05wDnl8Kv4TyJ7uM9TjMN8O7KdHMffqeGzocKCVVCzgIgoCVoI89otigFYQ4gatg/s500/steckdosenleiste%20anschluss%20fertig%20simple%20elektrrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;500&quot; data-original-width=&quot;500&quot; height=&quot;156&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhDvP-yjG1eFJJb0KxrKeJuHYgxjGUgAJ9VvbnFQ741ktRifogErUPFwllmS8bIPKISibcxYkATLJDx8qIsKKtZDuurwXy9luYrEj0iaWR5aWTQdVf0FttUdaUquH05wDnl8Kv4TyJ7uM9TjMN8O7KdHMffqeGzocKCVVCzgIgoCVoI89otigFYQ4gatg/w156-h156/steckdosenleiste%20anschluss%20fertig%20simple%20elektrrotechnik.jpg&quot; width=&quot;156&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&amp;nbsp;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/8734747051108371264/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/8734747051108371264' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/8734747051108371264'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/8734747051108371264'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/stecker-kupplung-anschliessen.html' title='Stecker / Kupplung anschliessen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiG0E7QiOkapkJfQGBfnbvKyl-Jdah386sXr1O2I8SVxlsxq7VjGSLTSBwMTl7OAD4f8hFs38fMax5C4kmw1-qdFqTlIlaBuMSZcA9eT49STLLN2BPWlsymD7fpYncOJap37_-Zbouynf2B8t1HZ4BVyKvT6zrsUpfWKJiYBw0xaBdJ_GZHy1DGTWj5Hg/s72-c/t12%20anschluss%20ohne%20simple%20elektrrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-4413559706340704121</id><published>2023-06-13T10:35:00.004-07:00</published><updated>2023-06-13T10:35:30.961-07:00</updated><title type='text'>Steckdosen richtig anschliessen</title><content type='html'>&lt;h2 style=&quot;text-align: justify;&quot;&gt;Anleitung zum Einbauen und Anschließen einer Steckdose&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjo8oVNK_gICQF-kJ4_3CZjk-KgCEZINfce1yUXjspvaCJdyLgBSb91DnWHef3BT5zREj12quYNz7sResFLttmNghll3BIUZZwD8d2XJSzFqjSoWTubKMJSRsMTPu16DhLCIcQTVFBRr6qvaqy1hAvKaTUeAxXiBUh6KN9G8_VfR8af9RMDxhdYA5xEsQ/s231/steckdose_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;231&quot; data-original-width=&quot;231&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjo8oVNK_gICQF-kJ4_3CZjk-KgCEZINfce1yUXjspvaCJdyLgBSb91DnWHef3BT5zREj12quYNz7sResFLttmNghll3BIUZZwD8d2XJSzFqjSoWTubKMJSRsMTPu16DhLCIcQTVFBRr6qvaqy1hAvKaTUeAxXiBUh6KN9G8_VfR8af9RMDxhdYA5xEsQ/w320-h320/steckdose_simple_elektrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Bitte beachten Sie alle Sicherheitsvorschriften während des gesamten Vorgangs:&lt;/h5&gt;
&lt;p&gt;&lt;b&gt;Schritt 1: Vorbereitung&lt;/b&gt;&lt;br /&gt; Stellen Sie sicher, dass der Stromkreis, an dem Sie arbeiten möchten, ausgeschaltet ist. Überprüfen Sie dies durch Abschalten des entsprechenden Sicherungskastens oder durch Entfernen der Sicherung.&lt;br /&gt; Verwenden Sie geeignete Schutzausrüstung, wie zum Beispiel Handschuhe und eine Schutzbrille, um Verletzungen zu vermeiden.&lt;br /&gt; Überprüfen Sie das Werkzeug, das Sie benötigen, um die Aufgabe durchzuführen. Dazu gehören in der Regel ein Schraubendreher, ein Spannungsprüfer, ein Cutter-Messer und Drahtschneider.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 2: Entfernen der alten Steckdose (falls vorhanden)&lt;/b&gt;&lt;br /&gt; Entfernen Sie die Abdeckplatte der vorhandenen Steckdose, indem Sie die Schrauben an den Ecken lösen.&lt;br /&gt; Lösen Sie die Schrauben, die die Steckdose an der Wand halten.&lt;br /&gt; Ziehen Sie die Steckdose vorsichtig aus der Wand und trennen Sie die Verbindungsklemmen ab, um die Drähte freizulegen.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 3: Vorbereitung der Verkabelung&lt;/b&gt;&lt;br /&gt; Überprüfen Sie den Zustand der vorhandenen Drähte. Wenn sie beschädigt oder abgenutzt sind, müssen sie ersetzt werden.&lt;br /&gt; Entfernen Sie vorsichtig die Isolierung der Enden der Drähte, etwa 1,5 cm, um die Kupferdrähte freizulegen.&lt;br /&gt; Überprüfen Sie den Leitungsquerschnitt der Drähte und stellen Sie sicher, dass er den Anforderungen entspricht. Üblicherweise beträgt der Querschnitt für Steckdosen 1,5 mm² oder 2,5 mm².&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 4: Anschließen der neuen Steckdose&lt;/b&gt;&lt;br /&gt; Schauen Sie sich die neue Steckdose an und identifizieren Sie die Anschlüsse: L (Phase), N (Neutralleiter) und PE (Schutzleiter).&lt;br /&gt; Verbinden Sie den Leiter mit der Bezeichnung L (Phase) mit dem entsprechenden Anschluss an der Steckdose. In der Regel wird dies durch eine Schraubklemme realisiert. Ziehen Sie die Schraube fest, um einen sicheren Kontakt herzustellen.&lt;/p&gt;
&lt;p&gt;&lt;br /&gt; Verbinden Sie den Leiter mit der Bezeichnung N (Neutralleiter) mit dem entsprechenden Anschluss an der Steckdose.&lt;br /&gt; Verbinden Sie den Leiter mit der Bezeichnung PE (Schutzleiter) mit dem entsprechenden Anschluss an der Steckdose. Dieser Draht ist normalerweise grün-gelb gekennzeichnet.&lt;br /&gt; Stellen Sie sicher, dass alle Verbindungen fest und sicher sind, indem Sie an den Drähten ziehen.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 5: Befestigen der Steckdose&lt;/b&gt;&lt;br /&gt; Positionieren Sie die Steckdose in der Wand und schieben Sie die Drähte vorsichtig in die dafür vorgesehenen Öffnungen in der Rückseite der Steckdose.&lt;br /&gt; Befestigen Sie die Steckdose an der Wand, indem Sie die Schrauben an den Ecken festziehen.&lt;br /&gt; Bringen Sie die Abdeckplatte wieder an und schrauben Sie sie fest.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schritt 6: Abschlussarbeiten&lt;/b&gt;&lt;br /&gt;Schalten Sie den Stromkreis wieder ein, indem Sie die Sicherung einschalten oder die entsprechende Schalterstellung am Sicherungskasten zurücksetzen.&lt;br /&gt; Verwenden Sie einen Spannungsprüfer, um zu überprüfen, ob die Steckdose ordnungsgemäß angeschlossen ist und Spannung führt.&lt;br /&gt; Testen Sie die Steckdose, indem Sie ein elektrisches Gerät anschließen und überprüfen, ob es funktioniert.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhrSauwTH3lJ4P2RCiUbjsAp7HT7lbKIrXmaEl1GlHBqfCJe2QP8f7v_fnW8cVgf5pkEXcpnMmbIZd0F5jae54JFzoJWpaaVaK1EqnbDp8e-IBENs5aJ3ljG17R2i-iE5fmEvmRxWub3YZyHrj4tR9jeRGhCSS8UIAtYrIdqqC9NZbGrlgFL8mX1cunKQ/s641/steckdosen%20anschluss%202.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;479&quot; data-original-width=&quot;641&quot; height=&quot;239&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhrSauwTH3lJ4P2RCiUbjsAp7HT7lbKIrXmaEl1GlHBqfCJe2QP8f7v_fnW8cVgf5pkEXcpnMmbIZd0F5jae54JFzoJWpaaVaK1EqnbDp8e-IBENs5aJ3ljG17R2i-iE5fmEvmRxWub3YZyHrj4tR9jeRGhCSS8UIAtYrIdqqC9NZbGrlgFL8mX1cunKQ/s320/steckdosen%20anschluss%202.JPG&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;Links (N) &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp; Mitte (PE) &amp;nbsp; &amp;nbsp; &amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp; Rechts (L)&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Bitte beachten Sie, dass es sich hierbei um eine generelle Anleitung handelt. Die genauen Schritte können je nach den örtlichen Vorschriften und elektrischen Standards variieren. Es wird dringend empfohlen, einen qualifizierten Elektriker zu konsultieren, wenn Sie unsicher sind oder keine Erfahrung mit Elektroinstallationen haben. Ihre Sicherheit hat oberste Priorität.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/4413559706340704121/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/4413559706340704121' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/4413559706340704121'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/4413559706340704121'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2023/06/steckdosen-richtig-anschliessen.html' title='Steckdosen richtig anschliessen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjo8oVNK_gICQF-kJ4_3CZjk-KgCEZINfce1yUXjspvaCJdyLgBSb91DnWHef3BT5zREj12quYNz7sResFLttmNghll3BIUZZwD8d2XJSzFqjSoWTubKMJSRsMTPu16DhLCIcQTVFBRr6qvaqy1hAvKaTUeAxXiBUh6KN9G8_VfR8af9RMDxhdYA5xEsQ/s72-w320-h320-c/steckdose_simple_elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-3533143109678536891</id><published>2023-06-13T10:32:00.000-07:00</published><updated>2023-06-13T10:32:53.711-07:00</updated><title type='text'>Der Fehlerstromschutzschalter RCD</title><content type='html'>&lt;h2 class=&quot;center&quot; style=&quot;text-align: justify;&quot;&gt;Ein möglicher Lebensretter !&lt;/h2&gt;
&lt;p&gt;Ein FI-Schutzschalter, auch als Fehlerstromschutzschalter oder RCD (Residual Current Device) bezeichnet, dient dem Schutz vor elektrischen Stromunfällen. Er erkennt Fehlerströme, die auftreten, wenn ein elektrischer Strom abweichend vom normalen Stromkreisverlauf fließt, beispielsweise durch einen Isolationsfehler oder einen Kurzschluss.&lt;/p&gt;
&lt;p&gt;Der FI-Schutzschalter überwacht den Unterschied zwischen dem Hin- und Rückstrom in einem Stromkreis. Normalerweise sollte der Hin- und Rückstrom gleich sein, da der Stromkreis geschlossen ist. Wenn ein Fehler auftritt, zum Beispiel wenn eine Person einen defekten elektrischen Geräteanschluss berührt, fließt ein Teil des Stroms über den Körper zur Erde ab und erzeugt einen Fehlerstrom. Der FI-Schutzschalter erkennt diese Abweichung und unterbricht den Stromkreis sofort, um einen möglichen Stromschlag zu verhindern.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhNjAtqNY3MavUlozy8m6yjNNtVQ4RAqfCnID73La-vEEsCZxH0CqhzC5wL_6xt5TMY8xLvsS5tCJRlPUhWGV_MlNRPnvZR3ZFdUyyMuk1gKph2k97-fXNvNDOFQanTInPYWvHoeeRIJB5Vx7u-IfjGH5Jmx2uo-oVFX0GGOfxCd6RMSO-e_oK00vRhNQ/s960/fehler_strom_schutzschalter_2_polig.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;640&quot; data-original-width=&quot;960&quot; height=&quot;213&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhNjAtqNY3MavUlozy8m6yjNNtVQ4RAqfCnID73La-vEEsCZxH0CqhzC5wL_6xt5TMY8xLvsS5tCJRlPUhWGV_MlNRPnvZR3ZFdUyyMuk1gKph2k97-fXNvNDOFQanTInPYWvHoeeRIJB5Vx7u-IfjGH5Jmx2uo-oVFX0GGOfxCd6RMSO-e_oK00vRhNQ/s320/fehler_strom_schutzschalter_2_polig.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h5&gt;Bezeichnungen:&lt;/h5&gt;
&lt;p&gt;RCD (Residual Current Device) ist der Oberbegriff für Fehlerstrom-Schutzschalter.&lt;/p&gt;
&lt;p&gt;RCCB (Residual Current Operated Circuit Breaker) bezeichnet den klassischen Fehlerstrom-Schutzschalter.&lt;/p&gt;
&lt;p&gt;RCBO (Residual Current Operated Circuit Breaker with Overcurrent Protection) steht für Fehlerstrom-Schutzschalter mit integriertem Leitungsschutz.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Typen und Kennwerte von FI Schutz-Schalter&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;br /&gt;&lt;/p&gt;
&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;table style=&quot;vertical-align: top;&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;text-align: left;&quot;&gt;
&lt;br /&gt;&lt;br /&gt;&lt;table style=&quot;box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;
&lt;td style=&quot;border: 1px solid rgb(0, 0, 0); width: 300px;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Art der Fehlerströme&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;border: 1px solid rgb(0, 0, 0); text-align: center; width: 35px;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Typ&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;border: 1px solid rgb(0, 0, 0); text-align: center;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Symbol&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Reine Wechselfehlerströme mit geringen Oberschwingungen und pulsierende Gleichfehlerströme&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;A&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEijXqBbybGrpbGfbGreJVmxtRo7rvbeEstOXevyLMayTmPFFJtbtc-zK9GGcaCvX2Pzl8t7fccm4NUISDdYNcqtTg2bkOJooTJKxKHjtJuVuWg1TJtEOaZfDuSJo2QjO0Qnql7LNrxftAC5_1k6rzjEaiAw_dVuusSweBqVTLQzJTfNqARxcSq6wB_rSg/s250/FI%20typ%20A%20symbol.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;250&quot; data-original-width=&quot;250&quot; height=&quot;40&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEijXqBbybGrpbGfbGreJVmxtRo7rvbeEstOXevyLMayTmPFFJtbtc-zK9GGcaCvX2Pzl8t7fccm4NUISDdYNcqtTg2bkOJooTJKxKHjtJuVuWg1TJtEOaZfDuSJo2QjO0Qnql7LNrxftAC5_1k6rzjEaiAw_dVuusSweBqVTLQzJTfNqARxcSq6wB_rSg/w40-h40/FI%20typ%20A%20symbol.gif&quot; width=&quot;40&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Fehlerströme vom Typ A, glatte Gleich und Wechselfehlerströme mit Frequenzen bis 2 kHz&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;B&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEizDdurDW_esg-NCwWavHisplolePPctoija7MPf792g-bhkFClxMSVv0V2mLEi9FFBqP_mkilEdO2qB7aLX-cQVZmqlNNmyEpAMNv7DGVqeMxMmdRE5arMYlSiaI2KpCg3Fopyi2bYD6GPRviBquO2n7YWzIBgPCqslG1hr43iCM_8AGx48u0P7oh-Og/s600/FI%20typ%20B+%20symbol.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;600&quot; data-original-width=&quot;250&quot; height=&quot;105&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEizDdurDW_esg-NCwWavHisplolePPctoija7MPf792g-bhkFClxMSVv0V2mLEi9FFBqP_mkilEdO2qB7aLX-cQVZmqlNNmyEpAMNv7DGVqeMxMmdRE5arMYlSiaI2KpCg3Fopyi2bYD6GPRviBquO2n7YWzIBgPCqslG1hr43iCM_8AGx48u0P7oh-Og/w44-h105/FI%20typ%20B+%20symbol.gif&quot; width=&quot;44&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Fehlerströme wie vom Typ B, glatte Gleich und Wechselfehlerströme mit Frequenzen bis 20 kHz&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;B+&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgNup-1XOhH4OdeB5LYgPKM8xhPKklmLydYzBqHe3h9JoUxuYmfYcfyA17R1_4GpeUhmAl2ACzvYpGHkdH54NA0cUGojT0wdO3qKh3WqP7Y9J2iGpBfdGQ2Y5ga35OCN2A0b8vZSDKBvTiclEecHy3D5S9U-2RfhBqHEvKFITG0QJnlq0r77Lhh8g8gxA/s600/FI%20typ%20B+%20symbol.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;600&quot; data-original-width=&quot;250&quot; height=&quot;114&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgNup-1XOhH4OdeB5LYgPKM8xhPKklmLydYzBqHe3h9JoUxuYmfYcfyA17R1_4GpeUhmAl2ACzvYpGHkdH54NA0cUGojT0wdO3qKh3WqP7Y9J2iGpBfdGQ2Y5ga35OCN2A0b8vZSDKBvTiclEecHy3D5S9U-2RfhBqHEvKFITG0QJnlq0r77Lhh8g8gxA/w48-h114/FI%20typ%20B+%20symbol.gif&quot; width=&quot;48&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Erfassung von nur sinusförmigen Wechselfehlerströmen. Achtung: Dieser Typ ist in Deutschland nicht zugelassen.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;AC&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgRP1K2HBtQgYjDybXBN4AW1fk3UnD7FoiCLXBLsABpJwyd7QnhWxouqFt8WRq2T4XkKufd7XqyO3ChUWWmJYoV2Mh_evWKqrHYqf4yvKs8WKO7jdrH768zn8H3Ov4nlgRFPBbKxwsHWsRne2vq4MXZJW0w0qEtZCDX7ybc4YX1HR7z71qwn0m9l2Ibag/s250/FI%20typ%20AC%20symbol.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;200&quot; data-original-width=&quot;250&quot; height=&quot;30&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgRP1K2HBtQgYjDybXBN4AW1fk3UnD7FoiCLXBLsABpJwyd7QnhWxouqFt8WRq2T4XkKufd7XqyO3ChUWWmJYoV2Mh_evWKqrHYqf4yvKs8WKO7jdrH768zn8H3Ov4nlgRFPBbKxwsHWsRne2vq4MXZJW0w0qEtZCDX7ybc4YX1HR7z71qwn0m9l2Ibag/w38-h30/FI%20typ%20AC%20symbol.gif&quot; width=&quot;38&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Fehlerströme vom Typ A, Wechselfehlerströme mit Mischfrequenzen&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;F&lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjck0TZQ-r_sCbAWbuPXUarf4VcN-haE5VYkp-nlj_t2jSVXdlSRwjDPcVC4IO9Mk5loh-SjUbwZ9kJ27AhyUGJfFE6RTX0Z67jfFyZvypza6R2Husv5txQca70Jy9zQZbdcGQHcFNyCjG2Fyw-HtYnJmysRyXcG1j28xQv508pa5BHhCo-WUpz3rgbwg/s400/FI%20typ%20F%20symbol.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;400&quot; data-original-width=&quot;250&quot; height=&quot;57&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjck0TZQ-r_sCbAWbuPXUarf4VcN-haE5VYkp-nlj_t2jSVXdlSRwjDPcVC4IO9Mk5loh-SjUbwZ9kJ27AhyUGJfFE6RTX0Z67jfFyZvypza6R2Husv5txQca70Jy9zQZbdcGQHcFNyCjG2Fyw-HtYnJmysRyXcG1j28xQv508pa5BHhCo-WUpz3rgbwg/w36-h57/FI%20typ%20F%20symbol.gif&quot; width=&quot;36&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;/td&gt;
&lt;td style=&quot;width: 50px;&quot;&gt;&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;/td&gt;
&lt;td style=&quot;text-align: right;&quot;&gt;
&lt;table style=&quot;box-shadow: rgb(226, 234, 238) 0px 0px 30px 16px;&quot;&gt;
&lt;tbody&gt;
&lt;tr style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0);&quot;&gt;
&lt;td colspan=&quot;2&quot; style=&quot;border: 1px solid rgb(0, 0, 0); text-align: left; width: 300px;&quot;&gt;
&lt;p&gt;Kennwerte von RCDs&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td colspan=&quot;2&quot; style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left;&quot;&gt;
&lt;p&gt;&lt;/p&gt;Fehlerstrom-Schutzeinrichtungen gibt es 2-polig und 4-polig mit Bemessungs-Differenzströmen von 10 mA bis 500 mA.&lt;br /&gt;&lt;br /&gt;Die Bemessungsströme betragen 10 A bis 125 A. &lt;br /&gt;RCDs mit ≤ 30 mA dienen dem Personenschutz und dem Brandschutz, höhere Bemessungs-Differenzströme dienen nur dem Brandschutz.&lt;span style=&quot;font-size: 10pt;&quot;&gt;&lt;/span&gt;&lt;p&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0); text-align: left;&quot;&gt;
&lt;p&gt;Sinnbilder / Kennzeichnung von RCDs&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #ffff99; border: 1px solid rgb(0, 0, 0); text-align: center;&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;Symbol &lt;/span&gt;&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;VDE Prüfzeichen&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;span style=&quot;font-size: 10pt;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjoRpGvHybZDsekDDBM2yHIK7u68StCgZFsgvfHOZfua8nLWjaa6o7h-qxlQHH2TuJz84-Vc1eR5DTlQSnCXH2_uOlJk1jXQkqzr8_0Tm1TQNGHm0SMlPigM4R4jrEF0ODlxVWRWfK-UqMvQZBwgaSAd62VkLAy2AsF39RxZ8OG4G8uCQTaii5ZH_jriA/s375/FI%20symbol%20dve.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;354&quot; data-original-width=&quot;375&quot; height=&quot;41&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjoRpGvHybZDsekDDBM2yHIK7u68StCgZFsgvfHOZfua8nLWjaa6o7h-qxlQHH2TuJz84-Vc1eR5DTlQSnCXH2_uOlJk1jXQkqzr8_0Tm1TQNGHm0SMlPigM4R4jrEF0ODlxVWRWfK-UqMvQZBwgaSAd62VkLAy2AsF39RxZ8OG4G8uCQTaii5ZH_jriA/w44-h41/FI%20symbol%20dve.gif&quot; width=&quot;44&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;Überstrom-Schutzeinrichtung vorschalten, kurzschlussfest bis z.B. 6kA&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhnD1XXtfNwA-Aw4fXH-fJyFcG8_xLwA4YycUDku7KQKYma3wzcJZNPmJYGFru9tzLDu1v7mZbmwqRur9DRdcwSLt-YW69OKtr_ArGrb_GEdKhh-A5cJv9sUDvYOFox_cjOISv-Y1TG8biVPdyHAMjioCaV2fhA3F_lR1T_RvV5yCzEkiFAY08CoiGX_Q/s1299/FI%20symbol%20ik.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;240&quot; data-original-width=&quot;1299&quot; height=&quot;20&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhnD1XXtfNwA-Aw4fXH-fJyFcG8_xLwA4YycUDku7KQKYma3wzcJZNPmJYGFru9tzLDu1v7mZbmwqRur9DRdcwSLt-YW69OKtr_ArGrb_GEdKhh-A5cJv9sUDvYOFox_cjOISv-Y1TG8biVPdyHAMjioCaV2fhA3F_lR1T_RvV5yCzEkiFAY08CoiGX_Q/w108-h20/FI%20symbol%20ik.gif&quot; width=&quot;108&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;für Betrieb bei tiefen Temperaturen z.B. -25°C&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiMYPL3ns8SM7mMJueJF82oOvltJft-HOlz3CQgBkCV2GpQN3t8u9yPXacA5Dwv6OA-JEbH89V_aRKgXbVcwicqwmyMuqDrsX7bsItzv4yOUNqxTqKout-koZUIdEHiAoZGkNL1ocf-_nOEIYW8yjTlQrFZ_8XuylGNgqWRBgmZqNFXU23Pe1aeMwUbIw/s423/FI%20symbol%20temp.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;423&quot; data-original-width=&quot;423&quot; height=&quot;41&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiMYPL3ns8SM7mMJueJF82oOvltJft-HOlz3CQgBkCV2GpQN3t8u9yPXacA5Dwv6OA-JEbH89V_aRKgXbVcwicqwmyMuqDrsX7bsItzv4yOUNqxTqKout-koZUIdEHiAoZGkNL1ocf-_nOEIYW8yjTlQrFZ_8XuylGNgqWRBgmZqNFXU23Pe1aeMwUbIw/w41-h41/FI%20symbol%20temp.gif&quot; width=&quot;41&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: left; vertical-align: middle;&quot;&gt;
&lt;p&gt;RCD Bauart S, selektiver FI-Schutzschalter, Auslösung ≤ 1s erst bei 2-fachem Auslöse Nennstrom&lt;/p&gt;
&lt;/td&gt;
&lt;td style=&quot;background-color: #e2eaee; border: 1px solid rgb(31, 26, 26); text-align: center; vertical-align: middle;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjIJ9-EesdaILJVi0T8GW1LFGOqjS1HJO7emBN8sQ1MeOESbpLGKr3oD6eb_YtkKJNAQndq-tdJmfAt1PsKfMO-e-MWc0RhUJtzb--xMXXdGXXYZU7RlTmQcQy1xwbAvF5t5KvtR0N4n4voY8mvprbZ1MXYpVJTDK9J0zQ1SRbB2RvhssaGiX3LL_jg2Q/s315/FI%20symbol%20selektiv.gif&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;303&quot; data-original-width=&quot;315&quot; height=&quot;36&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjIJ9-EesdaILJVi0T8GW1LFGOqjS1HJO7emBN8sQ1MeOESbpLGKr3oD6eb_YtkKJNAQndq-tdJmfAt1PsKfMO-e-MWc0RhUJtzb--xMXXdGXXYZU7RlTmQcQy1xwbAvF5t5KvtR0N4n4voY8mvprbZ1MXYpVJTDK9J0zQ1SRbB2RvhssaGiX3LL_jg2Q/w37-h36/FI%20symbol%20selektiv.gif&quot; width=&quot;37&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p class=&quot;style23&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Was passiert bei einem Stromunfall?&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Bei einem Stromunfall treten verschiedene Effekte auf, wenn eine Person einen elektrischen Stromkreis berührt oder damit in Kontakt kommt:&lt;/p&gt;
&lt;p&gt;Elektrischer Schlag: Wenn eine Person einen stromführenden Leiter oder einen Gegenstand berührt, der unter Spannung steht, fließt ein Strom durch ihren Körper. Ab einer bestimmten Stromstärke, normalerweise ab etwa 10 mA, kann dieser Strom den Körper beeinflussen. Die Elektrizität wirkt auf den Körper ein und beeinträchtigt die normale Kommunikation zwischen Gehirn und Muskeln.&lt;/p&gt;
&lt;p&gt;Muskuläre Reaktion: Der durch den Körper fließende Strom beeinflusst die Muskeln und kann dazu führen, dass sie sich unwillkürlich zusammenziehen. Dies wird als muskuläre Kontraktion bezeichnet. Es kann dazu führen, dass die betroffene Person den stromführenden Gegenstand nicht mehr loslassen kann, da die Muskeln nicht mehr unter bewusster Kontrolle stehen.&lt;/p&gt;
&lt;p&gt;Verletzungen durch Verbrennungen: Bei einem Stromunfall kann es zu Verbrennungen kommen. Der Stromfluss erzeugt Wärme im Gewebe, was zu Verbrennungen führen kann, insbesondere an den Stellen, an denen der Strom in den Körper eintritt oder austritt.&lt;/p&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass die Auswirkungen eines Stromunfalls von verschiedenen Faktoren wie der Stromstärke, der Dauer des Stromflusses, dem Weg des Stroms durch den Körper und dem Gesundheitszustand der betroffenen Person abhängen. Stromunfälle können von leichten Verletzungen bis hin zu schweren Verletzungen, einschließlich lebensbedrohlichen Zuständen, führen. Daher ist es äußerst wichtig, Vorsichtsmaßnahmen zu treffen, um solche Unfälle zu verhindern und im Notfall sofort medizinische Hilfe zu suchen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p class=&quot;style23&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Welche Einflussgrößen gibt es?&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Beim Stromdurchfluss durch den menschlichen Körper spielen verschiedene Faktoren eine Rolle: die Spannung, die Stromstärke, die Frequenz, der Widerstand des menschlichen Körpers und die Dauer, während der der Strom auf den Körper einwirkt.&lt;/p&gt;
&lt;p&gt;Fehlerstrom-Schutzschalter (RCDs) dienen dem Schutz von Personen, Tieren und Sachwerten im Falle eines Versagens des Basisschutzes oder des Fehlerstromschutzes. Sie ergänzen die angewendeten Schutzmaßnahmen. Durch die Überwachung von Isolationsfehlern und die Abschaltung von Kriechströmen tragen RCDs auch zum Brandschutz bei.&lt;/p&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass Fehlerstrom-Schutzschalter nur als zusätzliche Schutzmaßnahme und nicht als alleinige Schutzmaßnahme eingesetzt werden sollten.&lt;/p&gt;
&lt;p&gt;Ein Strom von 30 mA, der etwa 0,5 Sekunden über das Herz fließt, kann lebensbedrohlich sein. In diesem Fall kann es zu Herzflimmern kommen, wodurch die Pumpfunktion des Herzens gestört wird und die Sauerstoffversorgung des Gehirns gefährdet ist. Nach etwa drei bis fünf Minuten in diesem Zustand treten irreversible Schäden auf, und der Tod kann eintreten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h6 class=&quot;style22&quot; style=&quot;text-align: center;&quot;&gt;Kennlinie des Fehlerstromschutzschalters&lt;/h6&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg701mCHqaN3bDoJajJ-p7-I0GpKyBrpRonAal4TDvMb5-CB94OTMXb2_sQ8DzSGDVTeW5s5VNVpk7ehknlBSkXb9HueoN5kTA1IMFP98O85Vn_7ex_8F0W9DM_GAjirp19b93HgjC2ksgsI306andAqrpBmj4cZ9UG3MQUhctX3nQQtxOR6xawUOIyNA/s625/kennlinie_fehler_strom_schutzschalter.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;356&quot; data-original-width=&quot;625&quot; height=&quot;365&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg701mCHqaN3bDoJajJ-p7-I0GpKyBrpRonAal4TDvMb5-CB94OTMXb2_sQ8DzSGDVTeW5s5VNVpk7ehknlBSkXb9HueoN5kTA1IMFP98O85Vn_7ex_8F0W9DM_GAjirp19b93HgjC2ksgsI306andAqrpBmj4cZ9UG3MQUhctX3nQQtxOR6xawUOIyNA/w640-h365/kennlinie_fehler_strom_schutzschalter.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div id=&quot;simpletools&quot;&gt;&amp;nbsp;&lt;/div&gt;
&lt;p&gt;&lt;b&gt;Funktion eines Fehlerstrom-Schutzschalters&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Ein Fehlerstrom-Schutzschalter besteht im Wesentlichen aus drei Hauptkomponenten, die zusammenarbeiten, um im Fehlerfall den Stromkreis abzuschalten:&lt;/p&gt;
&lt;p&gt;Summenstromwandler: Der Summenstromwandler besteht aus Differenzialspulen und dient dazu, den Fehlerstrom zu erfassen und eine Spannung in der Messwicklung für den Fehlerstromauslöser zu erzeugen.&lt;/p&gt;
&lt;p&gt;Fehlerstromauslöser: Die Messwicklung des Fehlerstromauslösers erhält durch die Messwicklung des Summenstromwandlers eine Anregung. Im Fehlerfall wird eine mechanische Abschaltung ausgelöst. Die Fehlerstromauslösung erfolgt durch die Induktion einer Spannung in der Ausgangswicklung des Summenstromwandlers.&lt;/p&gt;
&lt;p&gt;Funktion des Fehlerstroms: Im fehlerfreien Zustand ist die Summe der eingehenden und ausgehenden Ströme null, wodurch in der Ausgangswicklung des Summenstromwandlers keine Spannung induziert wird. Bei Auftreten eines Fehlerstroms, der über den Schutzleiter oder die Erde zur Stromquelle zurückfließt, ist die Summe der Ströme nicht mehr null. Dies führt dazu, dass in der Ausgangswicklung des Summenstromwandlers eine Spannung induziert wird, die den elektromagnetischen Fehlerstromauslöser auslöst und den Stromkreis allpolig abschaltet.&lt;/p&gt;
&lt;p&gt;Die Prüftaste ermöglicht es, einen simulierten Fehlerstrom zu erzeugen und den Fehlerstrom-Schutzschalter auszulösen. Dies dient jedoch nur der Überprüfung der Auslösefunktion des RCDs und nicht der tatsächlichen Wirksamkeit des Schutzschalters insgesamt.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Wie verhindert der Fehlerstrom-Schutzschalter den Stromunfall?&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Der Fehlerstrom-Schutzschalter (auch RCD-Schalter oder FI-Schutzschalter genannt) verhindert Stromunfälle, indem er sicherstellt, dass bestimmte Grenzwerte nicht überschritten werden. Es gibt zwei- und vierpolige Fehlerstromschutzschalter für verschiedene Nennfehlerströme wie 10 mA, 30 mA, 300 mA und 500 mA.&lt;/p&gt;
&lt;p&gt;Heutzutage ist der Einsatz des 30 mA-Fehlerstromschutzschalters üblich, da er einen umfassenden Schutz auch bei direktem Berühren gewährleistet. Fehlerstromschutzschalter mit höherem Auslösestrom werden beispielsweise zum Schutz von Maschinen verwendet, bei denen bereits im Normalzustand ein geringer Fehlerstrom vorhanden sein kann. Eine gute Schutzwirkung bieten die 10 mA-Fehlerstromschutzschalter, da sie im Fehlerfall bereits vor dem Auftreten von Muskelverkrampfungen auslösen und die Stromversorgung abschalten.&lt;/p&gt;
&lt;p&gt;Für den mobilen Einsatz sind auch Fehlerstromschutzschalter im Handel erhältlich, die als PRCD-S bezeichnet werden. Sie erkennen Fehler in der Installation und schalten sich solange nicht mehr ein, wie der Fehler besteht.&lt;/p&gt;
&lt;p&gt;Das Prinzipschaltbild eines Fehlerstromschutzschalters wird in der Abbildung unten dargestellt. Im normalen Betrieb fließt der Strom, den die elektrischen Verbraucher benötigen, über die Zuleitung zum Verbraucher hin und in gleicher Größe wieder zurück. Der im Fehlerstromschutzschalter integrierte Summenstromwandler (Ringkern mit Wicklungen) vergleicht die Ströme, die durch die Leitungen fließen. Wenn die Summe der einfließenden Ströme nicht mehr der Summe der abfließenden Ströme entspricht, löst das &quot;verlorene Stromsignal&quot; ein Auslöserelais aus, das den überwachten Stromkreis sofort abschaltet.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h6 style=&quot;text-align: center;&quot;&gt;Prinzipschaltbild des Fehlerstromschutzschalters&lt;/h6&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiB917xCjAdSPCj74-GT75t1mKminzY3Eeev6x3C5xSUW50KwIyT0OmkZIE2e-hjucBH-ITC1G4JiytuRRWy0SI3I1O_c_DVu5XuFo35nKueQl9qFlOuqbUbu7YvjtrZbnQ0yiFm_Lg2u1dKmCpS_5PPr63hPm2SXZByfYTTgLBRCHr-9VFfbPAHvO-ug/s400/prinzip_schaltbild_eines_fehler_strom_schutzschalters.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;280&quot; data-original-width=&quot;400&quot; height=&quot;448&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiB917xCjAdSPCj74-GT75t1mKminzY3Eeev6x3C5xSUW50KwIyT0OmkZIE2e-hjucBH-ITC1G4JiytuRRWy0SI3I1O_c_DVu5XuFo35nKueQl9qFlOuqbUbu7YvjtrZbnQ0yiFm_Lg2u1dKmCpS_5PPr63hPm2SXZByfYTTgLBRCHr-9VFfbPAHvO-ug/w640-h448/prinzip_schaltbild_eines_fehler_strom_schutzschalters.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Funktionsprüfung des Fehlerstrom-Schutzschalters&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Alle Fehlerstromschutzschalter verfügen über eine Prüftaste, die einen Funktionstest ermöglicht. &lt;br /&gt;Dieser Test sollte alle 6 Monate von einem sachkundigen Benutzer durchgeführt werden. In gewerblichen Anlagen ist dieser Test sogar vorgeschrieben.&lt;br /&gt;&lt;br /&gt; Wenn der Funktionstest nicht durchgeführt wird, können die Kontakte verkleben, was im Fehlerfall zu einer mangelnden Auslösung führen kann.&lt;br /&gt; Der Fehlerstrom-Schutzschalter ist bei Neuinstallationen der aktuelle Stand der Technik.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/3533143109678536891/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/3533143109678536891' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/3533143109678536891'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/3533143109678536891'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/der-fehlerstromschutzschalter.html' title='Der Fehlerstromschutzschalter RCD'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhNjAtqNY3MavUlozy8m6yjNNtVQ4RAqfCnID73La-vEEsCZxH0CqhzC5wL_6xt5TMY8xLvsS5tCJRlPUhWGV_MlNRPnvZR3ZFdUyyMuk1gKph2k97-fXNvNDOFQanTInPYWvHoeeRIJB5Vx7u-IfjGH5Jmx2uo-oVFX0GGOfxCd6RMSO-e_oK00vRhNQ/s72-c/fehler_strom_schutzschalter_2_polig.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-2270848688720845276</id><published>2023-06-13T10:22:00.000-07:00</published><updated>2023-06-13T10:22:39.475-07:00</updated><title type='text'>Schaltungsarten von Leuchtstofflampen</title><content type='html'>&lt;h2&gt;Anleitung zum verdrahten und testen Leuchtstoff Lampen-Schaltungen&lt;/h2&gt;
&lt;p&gt;&lt;br /&gt;Eine der empfohlenen Schaltungsarten ist die sogenannte DUO Schaltung. Hierbei wird eine Leuchtstofflampe über ein induktives Vorschaltgerät betrieben, während die andere über ein kapazitives Vorschaltgerät betrieben wird. Durch die Parallelschaltung beider Schaltungen wird eine Phasenverschiebung des Stroms aufgehoben und der Leistungsfaktor beträgt ca. 0,95. Dies führt zu einer Überlappung der Hell- und Dunkelperioden der Lampen, wodurch kein Flimmern und kein stroboskopischer Effekt entsteht.&lt;/p&gt;
&lt;p&gt;Eine weitere effiziente Möglichkeit besteht in der Verwendung eines elektronischen Vorschaltgeräts. Durch den Einsatz eines solchen Geräts kann die Wirtschaftlichkeit der Beleuchtungsanlage um ca. 20 % gesteigert werden. Das elektronische Vorschaltgerät arbeitet mit einer Frequenz von ca. 35 kHz und ersetzt das herkömmliche Vorschaltgerät (Drosselspule). Beachten Sie jedoch, dass aufgrund der höheren Anschaffungskosten die Wirtschaftlichkeit erst gegeben ist, wenn die Lichtquelle mehr als 2500 Stunden pro Jahr in Betrieb ist.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Die Vorteile der DUO Schaltung im Überblick:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Wirtschaftliche Beleuchtungsanlage&lt;br /&gt; Flackerfreies und sofortiges Zünden der Leuchtstofflampen&lt;br /&gt; Kein Brummen&lt;br /&gt; Kein stroboskopischer Effekt&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5 style=&quot;text-align: center;&quot;&gt;Duo - Schaltung&lt;/h5&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirqAvtCjdqPuEtDaSxNGwJcrDWQRT1Yb8E3n-PM3gxbIvbKk8Crq_BD1-20nHyDKUNGZGVgQgJ8X2NE_ysdoC7tpT5_ZTXl_atv1pRisW94FpD14yCFLHDVZFI_R-GAqa-KujUcikIkIXwDvjUmvWS8YToYOkox45hG3NQK070IiTGMf76JB5MTzJmrQ/s600/schaltung%20duo%20leuchtstofflampe%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirqAvtCjdqPuEtDaSxNGwJcrDWQRT1Yb8E3n-PM3gxbIvbKk8Crq_BD1-20nHyDKUNGZGVgQgJ8X2NE_ysdoC7tpT5_ZTXl_atv1pRisW94FpD14yCFLHDVZFI_R-GAqa-KujUcikIkIXwDvjUmvWS8YToYOkox45hG3NQK070IiTGMf76JB5MTzJmrQ/w640-h410/schaltung%20duo%20leuchtstofflampe%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h6 style=&quot;text-align: center;&quot;&gt;induktive Einzelschaltung&lt;/h6&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgjyjVxe9USrQ2iCLmVDK6HJoOsJXPdLqPJbtc6Ks9WZtHz96P2GVccaNaX5L2pnq8f1EnnjU3vjGyBOMAwTo7-1dMBOmSZ3msyNieLZwZ02v6jJdF9NegF8WQegJnIi4cqCZZDVrbZyx6RSVcbloK01jDjgIA2h6MncFUr6ATk31zFH1MZoW3AoziR3g/s600/schaltung%20induktive%20einzelschaltung%20leuchtstofflampe%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgjyjVxe9USrQ2iCLmVDK6HJoOsJXPdLqPJbtc6Ks9WZtHz96P2GVccaNaX5L2pnq8f1EnnjU3vjGyBOMAwTo7-1dMBOmSZ3msyNieLZwZ02v6jJdF9NegF8WQegJnIi4cqCZZDVrbZyx6RSVcbloK01jDjgIA2h6MncFUr6ATk31zFH1MZoW3AoziR3g/w640-h410/schaltung%20induktive%20einzelschaltung%20leuchtstofflampe%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h6 style=&quot;text-align: center;&quot;&gt;kapazitive Einzelschaltung&lt;/h6&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgqra03IwxO8o2R9jgCtZQYUCgVwH5tv1mUhrpXyXnn04h6Ak8LRQOL-5BWN8y4DIjAs2_quxXBnlYkEWC1VoHQc6dCVyZBUr1npey2dApqaa5gioCbi4taeg6iujRKBZfpKiKXo2tYFDRwJOsQtS_y9SxhW9s9-Wj4HRJ0GxePZ2BIdysUFQ_qMuTHfQ/s600/schaltung%20kapazitive%20einzelschaltung%20leuchtstofflampe%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgqra03IwxO8o2R9jgCtZQYUCgVwH5tv1mUhrpXyXnn04h6Ak8LRQOL-5BWN8y4DIjAs2_quxXBnlYkEWC1VoHQc6dCVyZBUr1npey2dApqaa5gioCbi4taeg6iujRKBZfpKiKXo2tYFDRwJOsQtS_y9SxhW9s9-Wj4HRJ0GxePZ2BIdysUFQ_qMuTHfQ/w640-h410/schaltung%20kapazitive%20einzelschaltung%20leuchtstofflampe%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Elektronische Vorschaltgeräte (EVG) bieten gegenüber konventionellen Vorschaltgeräten bei Leuchtstofflampen verschiedene Vorteile:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;1. Energieeffizienz: EVGs arbeiten mit einer höheren Frequenz, was zu einer verbesserten Energieeffizienz führt. Sie wandeln den Strom effizienter um und reduzieren den Energieverlust im Vergleich zu konventionellen Vorschaltgeräten.&lt;/p&gt;
&lt;p&gt;2. Geringerer Energieverbrauch: Durch die höhere Effizienz ermöglichen EVGs einen geringeren Energieverbrauch. Dadurch können Sie Kosten senken und gleichzeitig umweltfreundlicher agieren.&lt;/p&gt;
&lt;p&gt;3. Flimmerfreies Licht: Im Gegensatz zu konventionellen Vorschaltgeräten sorgen EVGs für flimmerfreies Licht. Das bedeutet, dass die Leuchtstofflampen sofort und ohne sichtbares Flackern starten. Dies erhöht den visuellen Komfort und reduziert die Belastung der Augen.&lt;/p&gt;
&lt;p&gt;4. Längere Lampenlebensdauer: EVGs sorgen für eine sanftere und schonendere Ansteuerung der Leuchtstofflampen. Dies führt zu einer längeren Lebensdauer der Lampen, da sie weniger Belastungen ausgesetzt sind. Sie müssen also seltener ausgetauscht werden, was wiederum Kosten und Aufwand spart.&lt;/p&gt;
&lt;p&gt;5. Flexibilität: EVGs bieten oft zusätzliche Funktionen wie Dimmbarkeit und die Möglichkeit, verschiedene Arten von Leuchtstofflampen anzuschließen. Dadurch haben Sie mehr Kontrolle über die Beleuchtung und können sie an Ihre spezifischen Anforderungen anpassen.&lt;/p&gt;
&lt;p&gt;Insgesamt sind EVGs eine fortschrittliche Option für die Betreibung von Leuchtstofflampen, da sie energieeffizienter, langlebiger und komfortabler sind. Sie stellen eine lohnende Investition dar, insbesondere in Bereichen mit häufigem Betrieb oder hohen Anforderungen an die Lichtqualität.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h6 style=&quot;text-align: center;&quot;&gt;Elektronisches Vorschaltgerät&lt;/h6&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhIwasd7oyz1LJQhi_o8rOv9MAndEUZByrm71oLkVoMhChrre9UaLo6NhJDuAvxu62iMfSzFRB3CWTnTtLy7mgbE5fjOipicI6BettIGSLHDn5DZ_o-m9Lz3ADlUFXv8soyA8f8ukPSHhwNUelr0ZQg3ZMNLeMxaMKS4XPmL-lEHAigUHVaIR2t24lEkQ/s2560/elektronisches_vorschaltger%C3%A4t_f%C3%BCr_leuchtstoff_lampen.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;1920&quot; data-original-width=&quot;2560&quot; height=&quot;300&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhIwasd7oyz1LJQhi_o8rOv9MAndEUZByrm71oLkVoMhChrre9UaLo6NhJDuAvxu62iMfSzFRB3CWTnTtLy7mgbE5fjOipicI6BettIGSLHDn5DZ_o-m9Lz3ADlUFXv8soyA8f8ukPSHhwNUelr0ZQg3ZMNLeMxaMKS4XPmL-lEHAigUHVaIR2t24lEkQ/w400-h300/elektronisches_vorschaltger%C3%A4t_f%C3%BCr_leuchtstoff_lampen.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h6 style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/h6&gt;
&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/2270848688720845276/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/2270848688720845276' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/2270848688720845276'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/2270848688720845276'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/schaltungsarten-von-leuchtstofflampen.html' title='Schaltungsarten von Leuchtstofflampen'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirqAvtCjdqPuEtDaSxNGwJcrDWQRT1Yb8E3n-PM3gxbIvbKk8Crq_BD1-20nHyDKUNGZGVgQgJ8X2NE_ysdoC7tpT5_ZTXl_atv1pRisW94FpD14yCFLHDVZFI_R-GAqa-KujUcikIkIXwDvjUmvWS8YToYOkox45hG3NQK070IiTGMf76JB5MTzJmrQ/s72-w640-h410-c/schaltung%20duo%20leuchtstofflampe%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-5061519405548902646</id><published>2023-06-13T10:19:00.000-07:00</published><updated>2023-06-13T10:19:54.196-07:00</updated><title type='text'>Tasterschaltung korrekte Verdrahtung</title><content type='html'>&lt;h2 style=&quot;text-align: justify;&quot;&gt;Anleitung zum verdrahten und testen einer Tasterschaltung&lt;/h2&gt;
&lt;p&gt;Die Tasterschaltung in der Elektroinstallation ist eine Schaltung, die Taster und Relais verwendet. Sie findet typischerweise Anwendung beim Ein- und Ausschalten der Beleuchtung in Treppenhäusern und langen Fluren.&lt;/p&gt;
&lt;p&gt;Eine Tasterschaltung wird vor allem dann eingesetzt, wenn die Schaltung von vielen oder weit entfernten Stellen aus bedient werden muss. Bei dieser Schaltung fließt der Laststrom nicht über die Bedienstellen, sondern direkt und auf kurzem Weg zum Verbraucher. Dadurch werden elektrische Verluste minimiert. Eine Parallelschaltung aller Taster reduziert den Aufwand bei der Verkabelung. Jeder Taster kann die Schaltung bedienen. Die Relais werden idealerweise im Verteiler montiert, der auch die Sicherungen enthält.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Es gibt zwei Varianten von Tasterschaltungen:&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Stromstoßschaltung:&lt;/b&gt;&lt;br /&gt; Diese Variante verwendet bistabile Relais, die als Stromstoßschalter bezeichnet werden. Wenn kein Taster betätigt ist und dann ein beliebiger Taster gedrückt wird, erhält der Stromstoßschalter einen Spannungsimpuls. Dadurch kommt es zu einem Stromstoß durch den Elektromagneten im Relais. Der Elektromagnet betätigt den Schaltkontakt, der mechanisch in beiden Schaltstellungen einrastet. Jeder neue Spannungsimpuls führt zu einem Wechsel zwischen den beiden Schaltzuständen.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Treppenhausschaltung:&lt;/b&gt;&lt;br /&gt; Bei dieser Variante werden Zeitrelais verwendet, die als Treppenhausautomaten oder Treppenlichtautomaten bezeichnet werden. An allen Tastern kann die Beleuchtung eingeschaltet werden. Nach einer einstellbaren Zeit schaltet der Treppenhausautomat die Beleuchtung automatisch wieder aus. Es ist nicht möglich, die Beleuchtung an den Tastern auszuschalten. Bei hochwertigen Treppenhausautomaten kann durch erneutes Betätigen eines Tasters, bevor sich die Beleuchtung ausschaltet, der Zeitablauf des Automaten von neuem gestartet werden.&lt;/p&gt;
&lt;p&gt;Die Tasterschaltung ist eine praktische Lösung, um das Ein- und Ausschalten von Beleuchtung in verschiedenen Bereichen effizient zu steuern. Sie bietet hohe Flexibilität und reduziert den Verkabelungsaufwand, indem sie mehrere Taster miteinander verbindet und Relais verwendet, um den Laststrom direkt zum Verbraucher zu leiten.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5 style=&quot;text-align: center;&quot;&gt;Schaltbild einer Tasterschaltung&lt;/h5&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjuRzBQfq5qFYEBtj-bwi2qlCdG5uSeJGQGL7cRKEbHJnSwa5Ft8_G8r1sJzjSpH1bUwYoq-qTeY44hCIOshariHl1shasHmURysbePEAHiT8SiUdkehxMd1ZkBqaQXeHIQM2XByyndwAAk70vOFjvXZiAoySZGsxU-DeojG7vcOZL6Q3aduh0cDeI_vQ/s600/schaltung%20tasterschaltung%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjuRzBQfq5qFYEBtj-bwi2qlCdG5uSeJGQGL7cRKEbHJnSwa5Ft8_G8r1sJzjSpH1bUwYoq-qTeY44hCIOshariHl1shasHmURysbePEAHiT8SiUdkehxMd1ZkBqaQXeHIQM2XByyndwAAk70vOFjvXZiAoySZGsxU-DeojG7vcOZL6Q3aduh0cDeI_vQ/w640-h410/schaltung%20tasterschaltung%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Funktionsprobe:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Um die fertig verdrahtete Schaltung zu testen, gehen Sie ganz einfach vor:&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Mit Stromstoßschalter:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Betätigen Sie jeden Taster einmal, um das Licht einzuschalten, und nochmals, um es auszuschalten.&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;&lt;b&gt;Mit Treppenhausautomat:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Regulieren Sie die Zeiteinstellung des Treppenhausautomaten ganz nach unten, damit es nicht zu lange dauert.&lt;br /&gt; Betätigen Sie den ersten Taster und warten Sie, bis das Licht wieder ausgeht.&lt;br /&gt; Überprüfen Sie die Funktion bei den nächsten Tastern nacheinander.&lt;br /&gt; Wenn alles funktioniert hat, stellen Sie die gewünschte Zeit am Treppenhausautomaten ein und fertig!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/5061519405548902646/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/5061519405548902646' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5061519405548902646'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5061519405548902646'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/tasterschaltung.html' title='Tasterschaltung korrekte Verdrahtung'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjuRzBQfq5qFYEBtj-bwi2qlCdG5uSeJGQGL7cRKEbHJnSwa5Ft8_G8r1sJzjSpH1bUwYoq-qTeY44hCIOshariHl1shasHmURysbePEAHiT8SiUdkehxMd1ZkBqaQXeHIQM2XByyndwAAk70vOFjvXZiAoySZGsxU-DeojG7vcOZL6Q3aduh0cDeI_vQ/s72-w640-h410-c/schaltung%20tasterschaltung%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-3082727843553680384</id><published>2023-06-13T10:18:00.000-07:00</published><updated>2023-06-13T10:18:24.306-07:00</updated><title type='text'>Die Kontroll-Wechselschaltung korrekte Verdrahtung</title><content type='html'>&lt;h2&gt;Anleitung zum verdrahten und testen einer Kontroll - Wechselschaltung&lt;/h2&gt;
&lt;p&gt;Die Kontroll-Wechselschaltung ist eine wichtige Komponente in der Elektroinstallation, insbesondere wenn es darum geht, Verbraucher wie Leuchten von entfernten Stellen aus ein- und auszuschalten, ohne direkten Sichtkontakt zu haben.&lt;/p&gt;
&lt;p&gt;Für diese Schaltung werden zwei Kontrollwechselschalter benötigt. Alternativ können auch normale Wechselschalter verwendet und mit Glimmlampen nachgerüstet werden.&lt;/p&gt;
&lt;p&gt;Wenn der Verbraucher eingeschaltet wird, leuchten beide Kontrollleuchten auf. Im Gegensatz zur normalen Wechselschaltung kann die Kontrollwechselschaltung nicht zu einer Kreuzschaltung erweitert werden.&lt;/p&gt;
&lt;p&gt;Ein großer Vorteil der Kontroll-Wechselschaltung besteht darin, dass an beiden Schaltern der Außenleiter (L), der Neutralleiter (N) und der &quot;Lampendraht&quot; (in der Zeichnung orange) vorhanden sind. Zusätzlich kann an jedem Schalter eine Steckdose montiert werden, wenn auch der Schutzleiter (PE) verlegt wird. Dies erfordert lediglich fünf Adern für jede Schalter-Steckdosen-Kombination. Im Vergleich dazu benötigt die herkömmliche Wechselschaltung auf einer Seite fünf und auf der anderen Seite sechs Adern. Aufgrund der Einsparung einer Ader wird die Kontrollwechselschaltung auch als Sparwechselschaltung bezeichnet und kann auch mit normalen Wechselschaltern (ohne Glimmlampe) realisiert werden.&lt;/p&gt;
&lt;p&gt;Entdecken Sie die vielseitige Anwendung der Kontroll-Wechselschaltung in der Elektroinstallation und erfahren Sie, wie Sie mit dieser effizienten Schaltungsmöglichkeit Zeit und Ressourcen sparen können.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5 style=&quot;text-align: center;&quot;&gt;Schaltbild einer Kontroll - Wechselschaltung&lt;/h5&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhohr_8stFbpBPatFS3lbcmvHpA1D47wT4WIgOE4h4waU6gJMqOC7MHOukCYWhyTlSXMDc-7p26_qBG9kDQhema8fW_rb4gA4S6lBG70AAQ-iKmB_nCeYJa20t7PHqWK-8G_8dr39iMIYQeEUW66E9TiUzxKdEDhB6PfMwuQZxPBzg79R0z8_SJnB9N-w/s600/schaltung%20kontroll%20wechselschaltung%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhohr_8stFbpBPatFS3lbcmvHpA1D47wT4WIgOE4h4waU6gJMqOC7MHOukCYWhyTlSXMDc-7p26_qBG9kDQhema8fW_rb4gA4S6lBG70AAQ-iKmB_nCeYJa20t7PHqWK-8G_8dr39iMIYQeEUW66E9TiUzxKdEDhB6PfMwuQZxPBzg79R0z8_SJnB9N-w/w640-h410/schaltung%20kontroll%20wechselschaltung%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Funktionsprobe der Kontroll-Wechselschaltung&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Um die korrekte Funktion der fertig verdrahteten Schaltung zu testen, folge einfach diesen Schritten:&lt;/p&gt;
&lt;p&gt;Schalte abwechselnd den ersten und den zweiten Kontroll-Wechselschalter insgesamt viermal um. Dies kann entweder durch Hin- und Herlaufen oder mit Hilfe einer zweiten Person erfolgen.&lt;br /&gt; Bei jedem Schalten sollte die Lampe jeweils ein- und ausschalten.&lt;/p&gt;
&lt;p&gt;Falls die Lampe nicht wie erwartet reagiert, kann ein Fehler in der Verdrahtung vorliegen. In diesem Fall überprüfe bitte alle Anschlüsse und Verbindungen. Es ist wichtig, dass du genau viermal abwechselnd schaltest, da es Fehler geben kann, bei denen du zwar auf einer Seite einschalten kannst, aber auf der anderen Seite nicht wieder ausschalten kannst. Durch diesen Testvorgang kannst du solche Fehler erkennen und vermeiden, um unnötige Unannehmlichkeiten zu vermeiden.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/3082727843553680384/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/3082727843553680384' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/3082727843553680384'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/3082727843553680384'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/die-kontroll-wechselschaltung.html' title='Die Kontroll-Wechselschaltung korrekte Verdrahtung'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhohr_8stFbpBPatFS3lbcmvHpA1D47wT4WIgOE4h4waU6gJMqOC7MHOukCYWhyTlSXMDc-7p26_qBG9kDQhema8fW_rb4gA4S6lBG70AAQ-iKmB_nCeYJa20t7PHqWK-8G_8dr39iMIYQeEUW66E9TiUzxKdEDhB6PfMwuQZxPBzg79R0z8_SJnB9N-w/s72-w640-h410-c/schaltung%20kontroll%20wechselschaltung%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-1710461888781826937</id><published>2023-06-13T10:16:00.000-07:00</published><updated>2023-06-13T10:16:57.973-07:00</updated><title type='text'>Die Sparwechselschaltung korrekte Verdrahtung</title><content type='html'>&lt;h2&gt;Anleitung zum verdrahten und testen einer Spar - Wechselschaltung&lt;/h2&gt;
&lt;p&gt;Die Sparwechselschaltung ermöglicht das Ein- und Ausschalten von Verbrauchern, in der Regel ein oder mehrere Leuchten, von zwei verschiedenen Stellen aus.&lt;/p&gt;
&lt;p&gt;Für diese Schaltung werden zwei Wechselschalter benötigt, die auch als Aus-Wechselschalter im Handel erhältlich sind. Es sollte jedoch angemerkt werden, dass die meisten Hersteller keine reinen Ausschalter mehr produzieren.&lt;/p&gt;
&lt;p&gt;Im Gegensatz zur normalen Wechselschaltung kann die Sparwechselschaltung nicht zu einer Kreuzschaltung erweitert werden. Ein Vorteil der Sparwechselschaltung besteht darin, dass an beiden Schaltern der Außenleiter (L), der Neutralleiter (N) und der &quot;Lampendraht&quot; (in der Zeichnung orange) vorhanden sind. Wenn zusätzlich noch der Schutzleiter (PE) zu jedem Schalter gelegt wird, kann an jedem Schalter eine Steckdose installiert werden. Dadurch werden nur fünf Adern für jede Schalter-Steckdosen-Kombination benötigt. Im Gegensatz dazu erfordert die herkömmliche Wechselschaltung auf der einen Seite fünf und auf der anderen Seite sechs Adern. Aus diesem Grund wird sie auch als Sparwechselschaltung bezeichnet.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5 style=&quot;text-align: center;&quot;&gt;Schaltbild einer Spar - Wechselschaltung&lt;/h5&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhIBPspzAnU7KZIW-uZi6ck4XW7BXIbwl8Q8sAfOS9iXlkUo-JrqKh0X29BMfjABTGW0yW_cc6azjGyccO41KFXTX86nIkjN4t9tRjeKsinEiBRA6yJmmWpTH9t1Po0eKJRry1nxI7LfcauhR1hiQzHk8LmiN8xCsD53xNhSigYsk6vwNoAyiQFjCUg0g/s600/schaltung%20spar%20wechselschaltung%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhIBPspzAnU7KZIW-uZi6ck4XW7BXIbwl8Q8sAfOS9iXlkUo-JrqKh0X29BMfjABTGW0yW_cc6azjGyccO41KFXTX86nIkjN4t9tRjeKsinEiBRA6yJmmWpTH9t1Po0eKJRry1nxI7LfcauhR1hiQzHk8LmiN8xCsD53xNhSigYsk6vwNoAyiQFjCUg0g/w640-h410/schaltung%20spar%20wechselschaltung%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Funktionsprobe:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Um die fertig verdrahtete Schaltung zu testen, gehen Sie ganz einfach vor:&lt;/p&gt;
&lt;p&gt;Sie schalten abwechselnd beim ersten und dann beim zweiten Wechselschalter und das ganze viermal. (Entweder hin und her laufen oder mit zwei Personen). Dabei muss die Lampe jeweils aus- bzw. eingeschaltet werden.&lt;/p&gt;
&lt;p&gt;Sollte sie das nicht tun, so haben Sie einen Fehler gemacht und müssen alles kontrollieren. Es muss immer viermal geschaltet werden (abwechselnd), da es Fehler gibt, bei denen man zwar an der einen Seite einschalten kann, aber an der anderen Seite nicht wieder ausschalten kann. Ohne diesen Testvorgang könnte man solch einen Fehler übersehen und ärgert sich, dass man das gerade weggepackte Werkzeug wieder hervorholen muss.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/1710461888781826937/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/1710461888781826937' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1710461888781826937'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1710461888781826937'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/die-sparwechselschaltung.html' title='Die Sparwechselschaltung korrekte Verdrahtung'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhIBPspzAnU7KZIW-uZi6ck4XW7BXIbwl8Q8sAfOS9iXlkUo-JrqKh0X29BMfjABTGW0yW_cc6azjGyccO41KFXTX86nIkjN4t9tRjeKsinEiBRA6yJmmWpTH9t1Po0eKJRry1nxI7LfcauhR1hiQzHk8LmiN8xCsD53xNhSigYsk6vwNoAyiQFjCUg0g/s72-w640-h410-c/schaltung%20spar%20wechselschaltung%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-2517453953354373033</id><published>2023-06-13T10:15:00.000-07:00</published><updated>2023-06-13T10:15:39.977-07:00</updated><title type='text'>Wechselschaltung korrekte Verdrahtung</title><content type='html'>&lt;h2&gt;Anleitung zum verdrahten und testen einer Wechselschaltung&lt;/h2&gt;
&lt;p&gt;Eine Wechselschaltung ist eine spezielle Schaltung, die in der Elektrotechnik verwendet wird, um eine oder mehrere Leuchten oder ein anderes elektrisches Gerät von zwei verschiedenen Stellen aus ein- und auszuschalten. Sie besteht aus zwei Wechselstromschaltern, die miteinander verbunden sind.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Funktionsweise der Wechselschaltung:&lt;/b&gt;&lt;br /&gt;Zunächst benötigen Sie zwei Schalter, die als Wechselschalter bezeichnet werden. Nennen wir sie Schalter A und Schalter B. Beide Schalter haben drei Anschlüsse: den Eingangsanschluss (oft als L bezeichnet), den Ausgangsanschluss (auch als C bezeichnet) und den Reisanschluss (manchmal als P bezeichnet).&lt;/p&gt;
&lt;p&gt;Die Phase (L) wird an einen der beiden Wechselschalter an der Klemme L (bei älteren Schaltern P) angeschlossen. Dieser Anschluss ist oft farblich markiert, zum Beispiel in der Farbe Rot. Ebenso wird die Ader, die vom zweiten Wechselschalter zur Leuchte führt, oft als &quot;Lampendraht&quot; bezeichnet. Es ist wichtig zu beachten, dass der Schutzleiter (PE) immer grün-gelb sein muss und der Neutralleiter (N) idealerweise in der Farbe Hellblau ausgeführt ist.&lt;/p&gt;
&lt;p&gt;An der Eingangsklemme des ersten Wechselschalters wird der Außenleiter (L) angeschlossen. An der Eingangsklemme des zweiten Wechselschalters wird der Lampendraht angeschlossen. Die Ausgangsklemmen der beiden Wechselschalter werden mit 2 Drähten miteinander verbunden durch die sogenannten korrespondierenden Leiter.&lt;/p&gt;
&lt;p&gt;Um das Licht einzuschalten, können Sie entweder Schalter A oder Schalter B verwenden. Wenn Schalter A in der &quot;AN&quot;-Position ist, fließt der Strom vom Eingangsanschluss (L) durch Schalter A zum Reisanschluss (P) von Schalter B. Von dort aus fließt der Strom durch den Schalter B zur Leuchte oder zum Gerät und schaltet es ein. Wenn Sie Schalter B in die &quot;AN&quot;-Position bringen, erfolgt der Stromfluss in umgekehrter Richtung, aber das Ergebnis ist dasselbe: Die Leuchte oder das Gerät wird ein- beziehungsweise ausgeschaltet.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Es gibt einige wichtige sicherheitsrelevante Informationen, die Sie beachten sollten:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Bevor Sie mit der Installation einer Wechselschaltung beginnen, stellen Sie sicher, dass der Stromkreis an der Sicherung oder am Schaltkasten ausgeschaltet ist, um Stromschläge zu vermeiden.&lt;/p&gt;
&lt;p&gt;Verwenden Sie für die Verkabelung der Schaltung ausschließlich geeignete Kabel und stellen Sie sicher, dass die Kabelisolierung intakt ist, um Kurzschlüsse zu vermeiden.&lt;/p&gt;
&lt;p&gt;Achten Sie darauf, dass die Schalter ordnungsgemäß installiert und fest mit der Wand oder dem Gehäuse verbunden sind, um ein Herunterfallen oder Lockern zu verhindern.&lt;/p&gt;
&lt;p&gt;Vergewissern Sie sich, dass die Leuchte oder das Gerät für die verwendete Spannung und den Strom geeignet ist.&lt;/p&gt;
&lt;p&gt;Wenn Sie unsicher sind oder nicht über ausreichende elektrische Kenntnisse verfügen, ist es ratsam, einen qualifizierten Elektriker um Hilfe zu bitten.&lt;/p&gt;
&lt;p&gt;Die Wechselschaltung wird in Wohnhäusern, Büros, Hotels und anderen Orten eingesetzt, an denen eine Leuchte oder ein elektrisches Gerät von verschiedenen Stellen aus ein- und ausgeschaltet werden soll. Typische Anwendungsbereiche sind Flure und große Räume, in denen mehrere Eingänge vorhanden sind.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5 style=&quot;text-align: center;&quot;&gt;Schaltbild einer Wechselschaltung&lt;/h5&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi6P6f80YHTL_Ro17lXyjUnFpUpAsEMgKjL3r5jGYLdqlLI7B1zd9cpdihdVnDvFTXvKg5Pwx3b8Tk7iMQRUOSgbxK3qSmaV1NpR8Rb0JRHffsjth8DSEilknd4sQdQC1iLRcp9aHqYuAjWPQG3pr07edB6PWATSAVZAQxJXGmY03dhdF-cp27wahKmSQ/s600/schaltung%20wechselschaltung%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi6P6f80YHTL_Ro17lXyjUnFpUpAsEMgKjL3r5jGYLdqlLI7B1zd9cpdihdVnDvFTXvKg5Pwx3b8Tk7iMQRUOSgbxK3qSmaV1NpR8Rb0JRHffsjth8DSEilknd4sQdQC1iLRcp9aHqYuAjWPQG3pr07edB6PWATSAVZAQxJXGmY03dhdF-cp27wahKmSQ/w640-h410/schaltung%20wechselschaltung%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Funktionsprobe einer Wechselschaltung:&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Um die fertig verdrahtete Wechselschaltung zu testen, gehen Sie wie folgt vor:&lt;/p&gt;
&lt;p&gt;Schalten Sie abwechselnd den ersten und dann den zweiten Wechselschalter insgesamt viermal um. Sie können entweder zwischen den Schaltern hin und her gehen oder zwei Personen für diesen Test verwenden. Dabei sollte die Lampe jedes Mal ein- bzw. ausgeschaltet werden.&lt;/p&gt;
&lt;p&gt;Sollte die Lampe nicht wie erwartet ein- bzw. ausschalten, könnte ein Fehler in der Verdrahtung vorliegen. In diesem Fall müssen Sie alle Verbindungen kontrollieren und sicherstellen, dass sie korrekt ausgeführt wurden.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, dass Sie den Testvorgang viermal durchführen, abwechselnd zwischen den Schaltern schalten. Dies liegt daran, dass es möglicherweise Fehler gibt, bei denen die Lampe an einer Seite eingeschaltet werden kann, aber an der anderen Seite nicht wieder ausgeschaltet werden kann. Durch das wiederholte Schalten in beide Richtungen können Sie solche Fehler erkennen und korrigieren.&lt;/p&gt;
&lt;p&gt;Indem Sie diese Funktionskontrolle durchführen, können Sie sicherstellen, dass Ihre Wechselschaltung ordnungsgemäß funktioniert und es keine versteckten Fehler gibt.&lt;/p&gt;
&lt;p&gt;Wenn Sie diese Schritte befolgen, sind Sie in der Lage, die Funktionsfähigkeit Ihrer Wechselschaltung zu überprüfen und gegebenenfalls Fehler zu beheben, bevor Sie Werkzeuge und Materialien wegpacken.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/2517453953354373033/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/2517453953354373033' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/2517453953354373033'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/2517453953354373033'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/wechselschaltung.html' title='Wechselschaltung korrekte Verdrahtung'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi6P6f80YHTL_Ro17lXyjUnFpUpAsEMgKjL3r5jGYLdqlLI7B1zd9cpdihdVnDvFTXvKg5Pwx3b8Tk7iMQRUOSgbxK3qSmaV1NpR8Rb0JRHffsjth8DSEilknd4sQdQC1iLRcp9aHqYuAjWPQG3pr07edB6PWATSAVZAQxJXGmY03dhdF-cp27wahKmSQ/s72-w640-h410-c/schaltung%20wechselschaltung%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-5045998201443481754</id><published>2023-06-13T10:12:00.000-07:00</published><updated>2023-06-13T10:12:50.994-07:00</updated><title type='text'>Die Kreuzschaltung korrekte Verdrahtung</title><content type='html'>&lt;h2&gt;Anleitung zum verdrahten und testen einer Kreuzschaltung&lt;/h2&gt;
&lt;p&gt;Eine Kreuzschaltung ist eine effektive elektrische Schaltung, die es ermöglicht, einen Verbraucher von drei oder mehr Schaltern aus ein- und auszuschalten. Diese Schaltung wird häufig in Beleuchtungsanlagen, insbesondere in Fluren, eingesetzt.&lt;/p&gt;
&lt;p&gt;Die Grundstruktur einer Kreuzschaltung besteht aus zwei Wechselschaltern, die am Anfang und am Ende der Schaltung positioniert sind, sowie einer beliebigen Anzahl von Kreuzschaltern dazwischen. Jeder Kreuzschalter beinhaltet zwei mechanisch verbundene einpolige Umschalter, die so angeordnet sind, dass durch Betätigung zwischen einer &quot;geraden&quot; Verbindung (Links 1 - Rechts 1 / Links 2 - Rechts 2) und einer &quot;gekreuzten&quot; Verbindung (Links 1 - Rechts 2 / Links 2 - Rechts 1) gewechselt werden kann.&lt;/p&gt;
&lt;p&gt;Die Schalter werden jeweils mit zwei Adern verbunden, von denen je nach Schaltzustand des einzelnen Schalters eine Ader den Strom führt und die andere nicht. Durch Betätigung eines beliebigen Schalters werden die Zustände der weiterführenden Adern vertauscht. Dieses einfache, aber effektive Prinzip basiert auf boolescher Logik und führt zu einer Negation beider &quot;Signale&quot;. Ein &quot;EIN&quot;-Signal wird zu &quot;AUS&quot; und umgekehrt.&lt;/p&gt;
&lt;p&gt;Die Kreuzschaltung findet Anwendung beim wahlweisen Ein- oder Ausschalten von Beleuchtungen an drei oder mehreren Schaltstellen. Kreuzschalter verfügen über zwei Eingangsklemmen und zwei Ausgangsklemmen, die eine flexible Steuerung ermöglichen.&lt;/p&gt;
&lt;p&gt;Hier ein Beispiel für eine Variante mit 3 Schaltstellen:&lt;br /&gt;Der Außenleiter (L) wird an die Eingangsklemme des ersten Wechselschalters angeschlossen, während der Lampendraht an die Eingangsklemme des letzten Wechselschalters angeschlossen wird.&lt;/p&gt;
&lt;p&gt;Die beiden korrespondierenden Leiter verbinden die Ausgangsklemmen des ersten Wechselschalters mit dem ersten Kreuzschalter. Von dort aus führen beide korrespondierenden Leiter zum nächsten Kreuzschalter (abhängig von der Anzahl der Schaltstellen). Schließlich werden die korrespondierenden Leitungen vom letzten Kreuzschalter zum letzten Wechselschalter geführt und dort wieder an die Ausgangsklemmen angeschlossen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5 style=&quot;text-align: center;&quot;&gt;Schaltbild einer Kreuzschaltung&lt;/h5&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhqh7JxPYJpm3M-A2HunOQ-ixCi1WdDkKW4KK4JzpaOSlcMgNScFi13wHrqUT_JSHq1Hgxwe24x8woTP0HI8epLvUpRZU5ns0wFkV9D9uuPdAaMRIl5YJkGPAwxfo48CAsxrzHovCRTUPlHnlCQhsH_Y2N4W3H13f77j8ImKD_j_wk5YGwz1g_oltLyRA/s600/schaltung%20kreuzschaltung%20simple%20elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;385&quot; data-original-width=&quot;600&quot; height=&quot;410&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhqh7JxPYJpm3M-A2HunOQ-ixCi1WdDkKW4KK4JzpaOSlcMgNScFi13wHrqUT_JSHq1Hgxwe24x8woTP0HI8epLvUpRZU5ns0wFkV9D9uuPdAaMRIl5YJkGPAwxfo48CAsxrzHovCRTUPlHnlCQhsH_Y2N4W3H13f77j8ImKD_j_wk5YGwz1g_oltLyRA/w640-h410/schaltung%20kreuzschaltung%20simple%20elektrotechnik.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Funktionsprobe - So überprüfen Sie Ihre verdrahtete Schaltung&lt;/b&gt;&lt;/p&gt;
&lt;p&gt;Um die Funktionalität Ihrer verdrahteten Schaltung zu testen, folgen Sie einfach diesen Schritten:&lt;/p&gt;
&lt;p&gt;Schalten Sie nacheinander den ersten, den zweiten und den dritten Schalter ein, bis Sie zum letzten Schalter gelangen. Schalten Sie dann erneut den ersten Schalter ein. Die Lampe sollte bei jedem Schalten ein- bzw. ausschalten.&lt;/p&gt;
&lt;p&gt;Falls dies nicht der Fall ist, haben Sie wahrscheinlich einen Fehler gemacht. Überprüfen Sie alle Verbindungen sorgfältig. Es ist wichtig, dass Sie die Schalter in der richtigen Reihenfolge schalten, da es Fehler gibt, bei denen Sie zwar an einer Seite einschalten können, aber an der anderen Seite nicht wieder ausschalten können.&lt;/p&gt;
&lt;p&gt;Wiederholen Sie den Schaltvorgang insgesamt viermal (abwechselnd). Dieser Testvorgang ist entscheidend, um mögliche Fehler zu entdecken. Es wäre ärgerlich, wenn Sie das Werkzeug bereits weggelegt haben und dann feststellen, dass ein Problem vorliegt.&lt;/p&gt;
&lt;p&gt;Mit der Durchführung einer gründlichen Funktionsprobe stellen Sie sicher, dass Ihre Schaltung einwandfrei funktioniert und Sie mögliche Fehler rechtzeitig erkennen können.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/5045998201443481754/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/5045998201443481754' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5045998201443481754'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5045998201443481754'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2006/12/die-kreuzschaltung.html' title='Die Kreuzschaltung korrekte Verdrahtung'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhqh7JxPYJpm3M-A2HunOQ-ixCi1WdDkKW4KK4JzpaOSlcMgNScFi13wHrqUT_JSHq1Hgxwe24x8woTP0HI8epLvUpRZU5ns0wFkV9D9uuPdAaMRIl5YJkGPAwxfo48CAsxrzHovCRTUPlHnlCQhsH_Y2N4W3H13f77j8ImKD_j_wk5YGwz1g_oltLyRA/s72-w640-h410-c/schaltung%20kreuzschaltung%20simple%20elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-1120691591621633023</id><published>2023-06-13T10:09:00.000-07:00</published><updated>2023-06-13T10:09:25.700-07:00</updated><title type='text'>Elektro Herd im 3 Phasen Betrieb</title><content type='html'>&lt;h2&gt;Anleitung zum Einbau und Anschließen eines dreiphasigen Backofens (Elektroherd)&lt;/h2&gt;
&lt;p&gt;Es ist wichtig zu beachten, dass der Einbau und Anschluss eines dreiphasigen Backofens eine Aufgabe für einen qualifizierten Elektriker ist. Wenn Sie sich nicht sicher sind oder nicht über die erforderlichen Kenntnisse und Fähigkeiten verfügen, sollten Sie einen Fachmann hinzuziehen, um den Einbau durchzuführen. Die Sicherheit geht immer vor.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2ajoyZjPlHnNiXtQEWRmpHISdVNjmC5Tiu0Z383H5oXjQDyPdBXONnpbkvPviWY-oRlZU8wGxPZ3yxqGaFX0w1c9TwNrMKpQ4eDxPkWEj535dxGEryt7mKtPm9QyGEMkHFAm6EAeA1J0H3Is46qduwcIZTq-NliyPjEsnejF6eek1EKtjSFKSWaMCSA/s960/elektro_herd_simple_elektrotechnik.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;640&quot; data-original-width=&quot;960&quot; height=&quot;213&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2ajoyZjPlHnNiXtQEWRmpHISdVNjmC5Tiu0Z383H5oXjQDyPdBXONnpbkvPviWY-oRlZU8wGxPZ3yxqGaFX0w1c9TwNrMKpQ4eDxPkWEj535dxGEryt7mKtPm9QyGEMkHFAm6EAeA1J0H3Is46qduwcIZTq-NliyPjEsnejF6eek1EKtjSFKSWaMCSA/s320/elektro_herd_simple_elektrotechnik.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Überprüfen Sie vor Beginn der Installation die technischen Daten des Backofens und stellen Sie sicher, dass er für den dreiphasigen Anschluss ausgelegt ist. Vergewissern Sie sich außerdem, dass Ihre Stromversorgung für den Anschluss eines dreiphasigen Geräts geeignet ist.&lt;/p&gt;
&lt;p&gt;Schalten Sie vor dem Beginn der Installation die Hauptstromzufuhr in Ihrem Haushalt ab. Stellen Sie sicher, dass kein Strom in den Kabeln oder Geräten fließt, um das Risiko eines Stromschlags zu minimieren.&lt;/p&gt;
&lt;p&gt;Überprüfen Sie die mitgelieferte Dokumentation des Backofens, um die genaue Verkabelung und den Anschluss zu verstehen. Lesen Sie die Bedienungsanleitung sorgfältig durch und stellen Sie sicher, dass Sie die Anweisungen vollständig verstehen.&lt;/p&gt;
&lt;p&gt;Falls nicht vorhanden, besorgen Sie ein geeignetes fünf poliges Anschlusskabel, das den technischen Spezifikationen des Backofens entspricht. Wenden Sie sich im Zweifelsfall an einen qualifizierten Elektriker, um das richtige Kabel auszuwählen.&lt;/p&gt;
&lt;p&gt;Stellen Sie sicher, dass der Backofen ausgeschaltet ist und dass kein Strom zugeführt wird. Lösen Sie die Schrauben oder Muttern, die die Abdeckung des Anschlusskastens am Backofen sichern.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Entfernen Sie vorsichtig die Abdeckung des Anschlusskastens. Im Inneren sollten Sie die Anschlussklemmen sehen, an denen die Stromversorgung angeschlossen wird. Beachten Sie die Markierungen L1, L2 und L3 für die drei Phasen sowie PE (Schutzleiter) und N (Neutralleiter).&lt;/p&gt;
&lt;p&gt;Überprüfen Sie die Verkabelung der Stromversorgung, um sicherzustellen, dass sie den örtlichen Vorschriften und Sicherheitsstandards entspricht. Die Verkabelung sollte von einem zertifizierten Elektriker durchgeführt werden.&lt;/p&gt;
&lt;p&gt;Verbinden Sie die Phasen L1, L2 und L3 des Anschlusskabels des Backofens mit den entsprechenden Phasenklemmen im Anschlusskasten des Backofens. Achten Sie darauf, dass die Kabel fest und sicher angeschlossen sind.&lt;/p&gt;
&lt;p&gt;Verbinden Sie den Schutzleiter PE des Anschlusskabels mit der entsprechenden Klemme im Anschlusskasten des Backofens. Stellen Sie sicher, dass der Schutzleiter ordnungsgemäß angeschlossen ist, um eine sichere Erdung des Geräts zu gewährleisten.&lt;/p&gt;
&lt;p&gt;Verbinden Sie den Neutralleiter N des Anschlusskabels mit der entsprechenden Klemme im Anschlusskasten des Backofens. Stellen Sie sicher, dass die Verbindung sicher ist und den örtlichen Vorschriften entspricht.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Überprüfen Sie alle Verbindungen im Anschlusskasten sorgfältig, um sicherzustellen, dass keine losen Drähte oder Verbindungen vorhanden sind. Eine ordnungsgemäße Verbindung ist wichtig für die Sicherheit und den ordnungsgemäßen Betrieb des Backofens.&lt;/p&gt;
&lt;p&gt;Bringen Sie die Abdeckung des Anschlusskastens wieder an und befestigen Sie sie sicher mit den Schrauben oder Muttern.&lt;/p&gt;
&lt;p&gt;Überprüfen Sie ein letztes Mal alle Anschlüsse und Verbindungen, um sicherzustellen, dass sie korrekt und sicher sind.&lt;/p&gt;
&lt;p&gt;Schalten Sie die Hauptstromversorgung wieder ein und testen Sie den Backofen, um sicherzustellen, dass er ordnungsgemäß funktioniert. Befolgen Sie die Bedienungsanleitung des Backofens, um die ersten Schritte zur Inbetriebnahme durchzuführen.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Elektrischer Anschluß&lt;/h5&gt;
&lt;p&gt;Der Elektroherd wird üblicherweise mittels einer Herdanschlussdose als &quot;Festanschluss&quot; ans Stromnetz angeschlossen. Dabei wird in der Regel ein 400-V-Dreiphasen-Wechselstromanschluss für die Energieversorgung verwendet. Bei älteren Installationen sind jedoch auch einphasige 230-V-Versorgungen möglich.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;br /&gt;&lt;p class=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjhHu3Q-DfR95UL2UaqL5OC0mZbJmkR-5ncjT3SQEVbFgBaGnlFTTGZvWxQhNiTK2egLdvZzC-03MkjAUVST7FSuLyLAjAGD-ZbuqkRJTyZhHMW9tjLVDg-r7cO4YLLMheJDKkm3PHTjGd73BiggX1978g078gnSx6PoeQAiRx3hCuS6NZugVvDqBb9Xg/s960/stromkabel_anschluss_eherd.webp&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;638&quot; data-original-width=&quot;960&quot; height=&quot;213&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjhHu3Q-DfR95UL2UaqL5OC0mZbJmkR-5ncjT3SQEVbFgBaGnlFTTGZvWxQhNiTK2egLdvZzC-03MkjAUVST7FSuLyLAjAGD-ZbuqkRJTyZhHMW9tjLVDg-r7cO4YLLMheJDKkm3PHTjGd73BiggX1978g078gnSx6PoeQAiRx3hCuS6NZugVvDqBb9Xg/s320/stromkabel_anschluss_eherd.webp&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h5&gt;Für die sichere Installation des Kabels an den Anschlussklemmen des Herdes gelten die folgenden Empfehlungen:&lt;/h5&gt;
&lt;p&gt;&lt;b&gt;Grün-Gelb:&lt;/b&gt; &lt;br /&gt;Verbinden Sie den gelb-grünen Leiter (Schutzleiter oder Erdung) mit der Klemme, die das Erdungszeichen oder die Beschriftung &quot;PE&quot; trägt. Dies stellt die Erdungsverbindung des Herdes sicher.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Blau:&lt;/b&gt; &lt;br /&gt;Verbinden Sie den blauen Leiter (Neutralleiter) mit der Klemme, die die Beschriftung &quot;N&quot; trägt. Der Neutralleiter ist für die sichere Rückführung des Stroms verantwortlich.&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Schwarz, Braun und nochmal Schwarz:&lt;/b&gt; &lt;br /&gt;Verbinden Sie die schwarzen, braunen und schwarzen Leiter mit den Klemmen, die die Beschriftungen &quot;L1&quot;, &quot;L2&quot; und &quot;L3&quot; tragen. Die Reihenfolge der Phasenanschlüsse spielt keine Rolle, da es sich um einen Drehstromanschluss handelt.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Achten Sie darauf, dass bei einem neuen Herd die internen Verbindungen zwischen den Klemmen &quot;L1&quot;, &quot;L2&quot; und &quot;L3&quot; eventuell überbrückt sind. Diese Verbindungen müssen entfernt werden, um die einzelnen Phasen korrekt anzuschließen.&lt;/p&gt;
&lt;p&gt;Es ist wichtig, dass die einzelnen Leiter (Drähte) an den Enden Aderendhülsen haben. Diese dienen dazu, eine saubere und sichere Verbindung in den Anschlussklemmen herzustellen. Die Aderendhülsen sollten gemäß den örtlichen Vorschriften und Bestimmungen richtig dimensioniert sein.&lt;/p&gt;
&lt;p&gt;Zu beachten ist auch, dass manche Kabel einen zusätzlichen weißen Draht enthalten können. Dieser Draht ist jedoch kein elektrischer Leiter, sondern möglicherweise eine Kordel oder ein Material zur Stabilisierung des Kabels. In diesem Fall kann dieser weiße Draht bedenkenlos abgeschnitten werden, da er keine elektrische Funktion hat.&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;br /&gt;</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/1120691591621633023/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/1120691591621633023' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1120691591621633023'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/1120691591621633023'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2006/12/e-herd-richtig-anklemmen-im-3-phasen.html' title='Elektro Herd im 3 Phasen Betrieb'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2ajoyZjPlHnNiXtQEWRmpHISdVNjmC5Tiu0Z383H5oXjQDyPdBXONnpbkvPviWY-oRlZU8wGxPZ3yxqGaFX0w1c9TwNrMKpQ4eDxPkWEj535dxGEryt7mKtPm9QyGEMkHFAm6EAeA1J0H3Is46qduwcIZTq-NliyPjEsnejF6eek1EKtjSFKSWaMCSA/s72-c/elektro_herd_simple_elektrotechnik.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7270936414242968939.post-5055072513312405207</id><published>2009-02-01T04:46:00.000-08:00</published><updated>2009-02-01T04:50:33.822-08:00</updated><title type='text'>Bewegungsmelder</title><content type='html'>&lt;div&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align=&quot;left&quot;&gt;&lt;br /&gt;Es gibt eine Vielzahl von verschiedenen Bewegungsmeldern&lt;br /&gt;&lt;br /&gt;doch in der Regel funktionieren Sie nach dem selben Prinzip.&lt;br /&gt;&lt;br /&gt;Ein Bewegungsmelder hat in der Regel einen eingebauten Dämmerungsschalter, der dafür sorgt, dass die Beleuchtung nur bei Dunkelheit vom eigentlichen Bewegungsmelder eingeschaltet werden kann. Bewegt sich eine Wärmequelle vor dem Melder, so schaltet er die Beleuchtung für eine einstellbare Zeitspanne ein und nach Ablauf der eingestellten Leuchtzeit wieder aus. Die meisten Bewegungsmelder haben zwei Einsteller (Potentiometer):&lt;br /&gt;&lt;br /&gt;● die Einschaltdauer: legt fest, wie lange der Verbraucher eingeschaltet bleiben soll&lt;br /&gt;● die Umgebungshelligkeit (Hell-Dunkel-Grenze): legt fest, ab welcher Dunkelheitsschwelle der Melder scharf sein soll&lt;br /&gt;● die Empfindlichkeit: legt fest, wie schnell der Melder bei einer Bewegung einschalten soll&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Bei den meisten Bewegungsmeldern beginnt der Zähler für die Einschaltdauer, wenn die letzte Bewegung erkannt wurde. Wenn der Melder danach eine neue Bewegung erkennt, stellt er den Zähler wieder auf Null. Dies gewährleistet, dass der Verbraucher (z. B. Beleuchtung) nicht ausgeschaltet wird, wenn sich eine Person für längere Zeit im Erfassungsbereich aufhält.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Einfache Schaltung&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;img id=&quot;BLOGGER_PHOTO_ID_5297810039330620034&quot; style=&quot;DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 320px; CURSOR: hand; HEIGHT: 206px; TEXT-ALIGN: center&quot; alt=&quot;&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiEG_n1S1F4P30TRnXOgHQLAuvGnlK0LIivGiSVg3DCbqJ_2XvAFiAyXrDbgPrVOkwtjlvQ09UncRpekU64D2cyj7QjyExOZbF2nLFcDhLIcPDe1Z2kopUce9vY0575cNpD-1W8Oy_hDO-s/s320/Bewegungsmelder+Rieplay.PNG&quot; border=&quot;0&quot; /&gt;&lt;br /&gt;Bei dieser Schaltung wird ein Bewegungsmelder zum schalten von einer, zwei oder x... Lampen verwendet. Wenn der Bewegungsmelder im Erfassungsbereich Bewegung registriert schaltet er je nach dem wie er eingestellt ist ein.&lt;br /&gt;&lt;br /&gt;2 Bewegungsmelder&lt;br /&gt;&lt;br /&gt;&lt;img id=&quot;BLOGGER_PHOTO_ID_5297810150343589794&quot; style=&quot;DISPLAY: block; MARGIN: 0px auto 10px; WIDTH: 320px; CURSOR: hand; HEIGHT: 206px; TEXT-ALIGN: center&quot; alt=&quot;&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhcoXehEIW1NlqKP3C6elfSHpxm-kYgyBqqZ8vdYBzvP8QazEOLkzCWj10V3vDCf17XB5gJmsWzMuM5jx-V2EL4JtEVJqm66O0xGq4t-j_TZh5idKkqbARspAWM9BPm8sgZFm0lqqoRLEGD/s320/Bewegungsmelder+2fach+Rieplay.PNG&quot; border=&quot;0&quot; /&gt;&lt;br /&gt;Bei dieser Schaltung werden 2 Bewegungsmelder zum schalten von einer, zwei oder x... Lampen verwendet. Hierbei müssen Sie beachten dass Sie geeignete Bewegungsmelder benutzen. Wenn Bewegungsmelder 1 Bewegung registriert, schickt er ein Signal zu Bewegungsmelder 2 der dann die Lampen einschaltet.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Einstellung:&lt;br /&gt;In der Regel muss (kann) man beim ersten Bewegungsmelder die Schaltdauer, Empfindlichkeit, Umgebungshelligkeit einstellen. Hier sollte man eine sehr geringe Schaltdauer einstellen damit der zweite Bewegungsmelder geschont wird. Bei manchen kann man sogar auf ein Tast-Signal umstellen, das heißt, er sendet nur ca. 1 Sekunde das Signal und Bewegungsmelder 2 schaltet ein. Dass ist aber bei jedem Hersteller unterschiedlich.&lt;br /&gt;Beim zweiten muss man natürlich auch die Empfindlichkeit, Umgebungshelligkeit und die Zeit einstellen. Bei der Zeit muss man diesmal einstellen wie lange die Lampen eingeschaltet bleiben sollen.</content><link rel='replies' type='application/atom+xml' href='http://elektroinstallateur.blogspot.com/feeds/5055072513312405207/comments/default' title='Kommentare zum Post'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/7270936414242968939/5055072513312405207' title='0 Kommentare'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5055072513312405207'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7270936414242968939/posts/default/5055072513312405207'/><link rel='alternate' type='text/html' href='http://elektroinstallateur.blogspot.com/2009/02/bewegungsmelder.html' title='Bewegungsmelder'/><author><name>Rieplay</name><uri>http://www.blogger.com/profile/07035180257237500861</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiEG_n1S1F4P30TRnXOgHQLAuvGnlK0LIivGiSVg3DCbqJ_2XvAFiAyXrDbgPrVOkwtjlvQ09UncRpekU64D2cyj7QjyExOZbF2nLFcDhLIcPDe1Z2kopUce9vY0575cNpD-1W8Oy_hDO-s/s72-c/Bewegungsmelder+Rieplay.PNG" height="72" width="72"/><thr:total>0</thr:total></entry></feed>