<?xml version='1.0' encoding='UTF-8'?><rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:openSearch="http://a9.com/-/spec/opensearchrss/1.0/" xmlns:blogger="http://schemas.google.com/blogger/2008" xmlns:georss="http://www.georss.org/georss" xmlns:gd="http://schemas.google.com/g/2005" xmlns:thr="http://purl.org/syndication/thread/1.0" version="2.0"><channel><atom:id>tag:blogger.com,1999:blog-7558739020309204433</atom:id><lastBuildDate>Wed, 06 Nov 2024 02:43:30 +0000</lastBuildDate><category>progettazione impianti elettrici</category><category>consulente impianti</category><category>energia</category><category>fonti rinnovabili</category><category>giuseppe lucci</category><category>risparmio</category><category>certificazione energetica</category><category>impianti energia</category><category>consulente energia</category><category>Transitorio elettrico</category><category>lucci giuseppe</category><category>potenza di cortocircuito</category><category>sezione cavo</category><category>ATP-EMTP</category><category>CEI 64-8</category><category>PD</category><category>Protezioni Fulmini</category><category>atex</category><category>autorità energia elettrica e gas</category><category>committente</category><category>controversie legali</category><category>dimensionamento trasformatore</category><category>fattore di potenza; compensazione dinamica;</category><category>impianti elettrici</category><category>media tensione</category><category>potenza convenzionale</category><category>progettazione elettrica</category><category>progettazione sottostazioni</category><category>qualifica sismica</category><category>scarica parziale</category><category>scariche parziali</category><category>sicurezza elettrica</category><category>sismico</category><category>sistema elettrico</category><category>terremoto</category><title>Ingegneria elettrica</title><description>In questo sito si parla di elettrotecnica, impiantistica elettrica, energie rinnovabili,  sicurezza elettrica, e dello sviluppo del settore elettrotecnico.&#xa;&#xa;</description><link>http://impiantisticaelettrica.blogspot.com/</link><managingEditor>noreply@blogger.com (Unknown)</managingEditor><generator>Blogger</generator><openSearch:totalResults>36</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-7878910503218769635</guid><pubDate>Wed, 14 Oct 2020 19:30:00 +0000</pubDate><atom:updated>2020-10-15T01:13:05.214+02:00</atom:updated><title>Come le aziende risparmiare sul prezzo al kWh?</title><description>&lt;p&gt;&lt;span style=&quot;background-color: white;&quot;&gt;Per le aziende il prezzo dell&#39;energia elettrica è
condizionato da diverse &lt;/span&gt;&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;background-color: white;&quot;&gt;componenti,
alcune gestibili, altre no.&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;background: white; color: black; mso-color-alt: windowtext;&quot;&gt;&lt;b&gt;&lt;i&gt;Dove l’azienda può agire per abbassare i costi della bolletta
? &lt;/i&gt;&lt;/b&gt;&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Sicuramente sulla scelta oculata del
fornitore. &lt;/span&gt;&lt;span style=&quot;background: white;&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;background: white; color: black; mso-color-alt: windowtext;&quot;&gt;Oggi, grazie al mercato libero&amp;nbsp;sono tante le offerte
disponibili per le aziende, a&amp;nbsp;prezzo fisso, bloccato per un certo periodo
di anni,&amp;nbsp;oppure a&amp;nbsp;prezzo variabile,&amp;nbsp;in base al PUN,&amp;nbsp;&lt;a href=&quot;https://luce-gas.it/guida/mercato/pun&quot; target=&quot;_blank&quot;&gt;&lt;span style=&quot;color: black; mso-color-alt: windowtext; text-decoration: none; text-underline: none;&quot;&gt;prezzo unico nazionale&lt;/span&gt;&lt;/a&gt;&amp;nbsp;di riferimento del mercato
all&#39;ingrosso dell&#39;energia in Italia.&lt;/span&gt;&lt;span style=&quot;background: white;&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;background-attachment: initial; background-clip: initial; background-color: #fcff01; background-image: initial; background-origin: initial; background-position: initial; background-repeat: initial; background-size: initial; background: rgb(252, 255, 1); color: black; mso-color-alt: windowtext;&quot;&gt;Tutti i fornitori del mercato libero&lt;/span&gt;&lt;span style=&quot;background: white; color: black; mso-color-alt: windowtext;&quot;&gt;, come&amp;nbsp;Enel Energia,&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;-webkit-text-stroke-width: 0px; float: none; font-variant-caps: normal; font-variant-ligatures: normal; orphans: 2; text-align: start; text-decoration-color: initial; text-decoration-style: initial; widows: 2; word-spacing: 0px;&quot;&gt;Edison,&amp;nbsp;Green Network, A2A, Acea, Eni, Sorgenia, etc. &lt;span style=&quot;background-color: #fcff01;&quot;&gt;propongono tariffe
dedicate per le&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;background-color: #fcff01;&quot;&gt;aziende.&lt;/span&gt;&lt;span style=&quot;background: white;&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot;&gt;&lt;br /&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot;&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;Il costo medio del kWh in bolletta per le aziende:&lt;/b&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Il&amp;nbsp;&lt;b&gt;costo medio
al kWh&lt;/b&gt;&amp;nbsp;è legato anche dagli altri oneri presenti e dalle imposte, che
cambiano in base alla &lt;a href=&quot;https://luce-gas.it/guida/contatore/potenza&quot;&gt;&lt;span color=&quot;windowtext&quot; style=&quot;text-decoration-line: none;&quot;&gt;potenza del
contatore&lt;/span&gt;&lt;/a&gt;. Le voci nella bolletta luce di un&#39;utenza a partita IVA
sono:&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpFirst&quot; style=&quot;mso-list: l0 level1 lfo1; text-indent: -18.0pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol; mso-fareast-language: IT;&quot;&gt;·&lt;span style=&quot;font-family: &amp;quot;Times New Roman&amp;quot;; font-size: 7pt; font-stretch: normal; font-variant-east-asian: normal; font-variant-numeric: normal; line-height: normal;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;b&gt;&lt;i&gt;&lt;a href=&quot;https://luce-gas.it/guida/bolletta/luce/spesa-materia-energia&quot;&gt;&lt;span style=&quot;color: windowtext; text-decoration-line: none;&quot;&gt;spesa materia
prima&lt;/span&gt;&lt;/a&gt;,&lt;/i&gt;&lt;/b&gt; per
l&#39;acquisto dell&#39;energia elettrica e la commercializzazione;&lt;o:p&gt;&lt;/o:p&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;mso-list: l0 level1 lfo1; text-indent: -18.0pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol; mso-fareast-language: IT;&quot;&gt;·&lt;span style=&quot;font-family: &amp;quot;Times New Roman&amp;quot;; font-size: 7pt; font-stretch: normal; font-variant-east-asian: normal; font-variant-numeric: normal; line-height: normal;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;b&gt;&lt;i&gt;&lt;a href=&quot;https://luce-gas.it/guida/bolletta/luce/spesa-trasporto-gestione-contatore&quot;&gt;&lt;span style=&quot;color: windowtext; text-decoration-line: none;&quot;&gt;spesa per
trasporto&lt;/span&gt;&lt;/a&gt;&amp;nbsp;e gestione del contatore,&lt;/i&gt;&lt;/b&gt; per la distribuzione dell&#39;energia sulla rete;&lt;o:p&gt;&lt;/o:p&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;mso-list: l0 level1 lfo1; text-indent: -18.0pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol; mso-fareast-language: IT;&quot;&gt;·&lt;span style=&quot;font-family: &amp;quot;Times New Roman&amp;quot;; font-size: 7pt; font-stretch: normal; font-variant-east-asian: normal; font-variant-numeric: normal; line-height: normal;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;b&gt;&lt;i&gt;&lt;a href=&quot;https://luce-gas.it/guida/bolletta/luce/spesa-oneri-sistema&quot;&gt;&lt;span style=&quot;color: windowtext; text-decoration-line: none;&quot;&gt;oneri di
sistema&lt;/span&gt;&lt;/a&gt;,&lt;/i&gt;&lt;/b&gt; per
attività generali del sistema elettrico (sostegno alle rinnovabili, incentivi
alle industrie energivore ecc.);&lt;o:p&gt;&lt;/o:p&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;







&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpLast&quot; style=&quot;mso-list: l0 level1 lfo1; text-indent: -18.0pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family: Symbol; mso-bidi-font-family: Symbol; mso-fareast-font-family: Symbol; mso-fareast-language: IT;&quot;&gt;·&lt;span style=&quot;font-family: &amp;quot;Times New Roman&amp;quot;; font-size: 7pt; font-stretch: normal; font-variant-east-asian: normal; font-variant-numeric: normal; line-height: normal;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;b&gt;&lt;i&gt;imposte,
accise&amp;nbsp;e IVA&lt;/i&gt;&lt;/b&gt;,
stabilite dallo Stato (esistono&amp;nbsp;&lt;a href=&quot;https://luce-gas.it/business/agevolazioni-fiscali-energia-elettrica-imprese&quot;&gt;&lt;span style=&quot;color: windowtext; text-decoration-line: none;&quot;&gt;agevolazioni
fiscali&lt;/span&gt;&lt;/a&gt;&amp;nbsp;per le imprese).&lt;o:p&gt;&lt;/o:p&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;text-indent: -18pt;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;text-indent: -18pt;&quot;&gt;Ecco il prezzo medio
dei clienti non domestici registrato nel 2018, al netto delle imposte. Nel
costo della materia prima è incluso l&#39;approvvigionamento energia, il
dispacciamento, le perdite di rete e i costi di commercializzazione della
vendita.&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;mso-fareast-language: IT;&quot;&gt;&lt;/span&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhx59vIzp9kdZrUE3TMNBvDXuVnj-FMNLMYYzqyQgpWRifYO23rq_EGMv57qFAzoqbX5FvxwMLPs8ssmfxO2lca3HHzAUU3LqcRQe2M8HL0AN75bdqlaC0zxKXbP82vV92OXmSv-TmWO-kM/&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img alt=&quot;&quot; data-original-height=&quot;148&quot; data-original-width=&quot;643&quot; height=&quot;93&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhx59vIzp9kdZrUE3TMNBvDXuVnj-FMNLMYYzqyQgpWRifYO23rq_EGMv57qFAzoqbX5FvxwMLPs8ssmfxO2lca3HHzAUU3LqcRQe2M8HL0AN75bdqlaC0zxKXbP82vV92OXmSv-TmWO-kM/w400-h93/image.png&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;span face=&quot;&amp;quot;Trebuchet MS&amp;quot;, Ubuntu, sans-serif&quot; style=&quot;background-color: white; color: #565e66; font-size: x-small;&quot;&gt;Prezzo medio finale clienti non domestici - 2018&lt;/span&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2020/10/come-risparmiare-sul-prezzo-al-kwh.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhx59vIzp9kdZrUE3TMNBvDXuVnj-FMNLMYYzqyQgpWRifYO23rq_EGMv57qFAzoqbX5FvxwMLPs8ssmfxO2lca3HHzAUU3LqcRQe2M8HL0AN75bdqlaC0zxKXbP82vV92OXmSv-TmWO-kM/s72-w400-h93-c/image.png" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-1897893014404816292</guid><pubDate>Mon, 25 Feb 2019 17:29:00 +0000</pubDate><atom:updated>2019-02-25T18:29:52.567+01:00</atom:updated><title>Sicurezza Elettrica: Lavori su Elettrodotti in Alta Tensione</title><description>&lt;div style=&quot;text-align: justify;&quot;&gt;
&lt;span style=&quot;background-color: white; color: #757575; font-family: Roboto, sans-serif; font-size: 15px;&quot;&gt;Un approfondita conoscenza della sicurezza elettrica e&#39; fondamentale, soprattutto durante i lavori di manutenzione su elettrodotti in Alta Tensione, anche non alimentati elettricamente. Come mostrato in foto, gli effetti della carica capacitiva su un elettrodotto non alimentato in Alta Tensione possono provocare incidenti mortali, se non gestiti in maniera adeguata&lt;/span&gt;&lt;/div&gt;
&lt;span style=&quot;background-color: white; color: #757575; font-family: Roboto, sans-serif; font-size: 15px;&quot;&gt;&lt;br /&gt;&lt;/span&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhyYCqfB409Y7K7gk7toUv8Hjm8wfPClbhf5XJYm44MfFZ2zMBVONfd58KAhfkkGlEA-X2YE7ZSThDPtTK8ejgRebuhhhrCr32q8LALfWMPf5No-R6zycIvUwypVTqdtOBxo6t4qcKQg3Kr/s1600/Screen+Shot+2019-02-24+at+14.03.17.png&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;606&quot; data-original-width=&quot;523&quot; height=&quot;640&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhyYCqfB409Y7K7gk7toUv8Hjm8wfPClbhf5XJYm44MfFZ2zMBVONfd58KAhfkkGlEA-X2YE7ZSThDPtTK8ejgRebuhhhrCr32q8LALfWMPf5No-R6zycIvUwypVTqdtOBxo6t4qcKQg3Kr/s640/Screen+Shot+2019-02-24+at+14.03.17.png&quot; width=&quot;552&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;span style=&quot;background-color: white; color: #757575; font-family: Roboto, sans-serif; font-size: 15px;&quot;&gt;&lt;br /&gt;&lt;/span&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2019/02/sicurezza-elettrica-lavori-su.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhyYCqfB409Y7K7gk7toUv8Hjm8wfPClbhf5XJYm44MfFZ2zMBVONfd58KAhfkkGlEA-X2YE7ZSThDPtTK8ejgRebuhhhrCr32q8LALfWMPf5No-R6zycIvUwypVTqdtOBxo6t4qcKQg3Kr/s72-c/Screen+Shot+2019-02-24+at+14.03.17.png" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-1296958545702263125</guid><pubDate>Tue, 12 Feb 2019 03:50:00 +0000</pubDate><atom:updated>2020-10-13T04:51:29.491+02:00</atom:updated><title>Progettazione Datacenters: Certificazione TIER, compromesso tra Ridondanza e CAPEX</title><description>&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;mso-fareast-language: IT;&quot;&gt;Lo Standard TIA-942
definisce 4 livelli TIER di ridondanza dell&#39;infrastruttura dei sitemi Mission
Critical.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; mso-fareast-language: IT; padding: 0cm;&quot;&gt;TIER 1&amp;nbsp;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;mso-fareast-language: IT;&quot;&gt;- Nessuna Ridondanza. E&#39; suscettibile di
interruzioni causatesia da attività pianificate che non pianificate. Può non
avere un UPS, o un generatore ausiliario. Una situazione di emergenza richiede
spessolo spegnimento totale, così come un errore umano può comportare lo
spegnimento dei sistemi.&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; padding: 0cm;&quot;&gt;&amp;nbsp;La ridondanza dei sistemi
è N.&lt;/span&gt;&lt;/b&gt;&amp;nbsp;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; padding: 0cm;&quot;&gt;Fuoriservizio annuale: 28.8h&lt;/span&gt;&lt;/b&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; mso-fareast-language: IT; padding: 0cm;&quot;&gt;TIER 2 -&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;mso-fareast-language: IT;&quot;&gt;&amp;nbsp;Componenti ridondati ma singolo path. La
presenza di componenti ridondanti rende meno probabile l&#39;interruzione dei
servizi sia per attività pianificate che non pianificate. Elettricità e
raffreddamento hanno path singoli. La manutenzione delle linee di
alimentazionee di altre parti della struttura del sito richiede il fuori
servizio dell&#39;infrastruttura.&amp;nbsp;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; padding: 0cm;&quot;&gt;La ridondanza dei sistemi è
N+1. Fuoriservizio annuale: 22h&lt;/span&gt;&lt;/b&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; mso-fareast-language: IT; padding: 0cm;&quot;&gt;TIER 3 -&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;mso-fareast-language: IT;&quot;&gt;&amp;nbsp;Componenti ridondati, path multipli, un
singolo path attivo. Un infrastruttura di questo tipo ha più path, di cui uno
solo attivo. Questo vuol dire che è sempre possibile fermare uno solo dei path
per effettuare manutenzione preventiva e programmata, riparazioni ed
aggiornamento di componenti, aggiunta e rimozione di componenti, testing ed
altro.&amp;nbsp;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; padding: 0cm;&quot;&gt;La ridondanza dei sistemi è N+1. Fuoriservizio annuale: 1.6h&lt;/span&gt;&lt;/b&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; mso-fareast-language: IT; padding: 0cm;&quot;&gt;TIER 4 -&amp;nbsp;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;mso-fareast-language: IT;&quot;&gt;Componenti ridondati tutti attivi, path
multipli. Path multipli sono attivi contemporaneamente: è possibile ogni tipo
di manutenzione programmata senza interrompere le operazioni, il sito può
sostenere un guasto o un errore umano senza impatto sulle operazioni. Questo
vuol dire, ad esempio elettricamente, che ci sono due sistemidi UPS, ognunoin
ridondanza N+1, il che porta la ridondanza del sistema ad un valore di&amp;nbsp;&lt;b&gt;&lt;span style=&quot;border: none windowtext 1.0pt; mso-border-alt: none windowtext 0cm; padding: 0cm;&quot;&gt;(2*(N+1)). Fuoriservizio annuale: 0.26h&lt;/span&gt;&lt;/b&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;mso-fareast-language: IT;&quot;&gt;I livelli TIER
descrivono i componenti dell’infrastruttura Mission Critical ed il loro livello&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2020/10/progettazione-datacenters.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total><georss:featurename>Italy</georss:featurename><georss:point>41.87194 12.56738</georss:point><georss:box>-37.529866619704585 -128.05762 90 153.19238</georss:box></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-3489116231450658398</guid><pubDate>Sun, 10 Feb 2019 13:07:00 +0000</pubDate><atom:updated>2019-02-10T14:07:04.777+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">fattore di potenza; compensazione dinamica;</category><title>Compensazione Dinamica del Fattore di Potenza </title><description>&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
Oggi gli impianti industriali sono caratterizzati dall&#39;utilizzo di azionamenti elettrici dinamici. Questetecnologie, se pur ofrendo enotrmi vatnaggi in termini di efficienza, hanno lo svantaggio di introdurre inqinamento armotico nella rete elettrica.&amp;nbsp;&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
Ciò provoca condizioni di tensione instabili, fliker, carichi di corrente eccessivi e maggiori perdite nella distribuzione di energia elettrica.Questo a sua volta non solo riduce la potenza della rete utilizzabile, ma influisce anche sulle funzioni dei controller elettronici sensibili.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
I sistemi convenzionali di correzione del fattore di potenza sono progettati per la pura ottimizzazione del fattore di potenza e anche per ridurre il livello di armoniche, ma non sono in grado di stare al passo con rapidi cambiamenti di carico e non forniscono una soluzione soddisfacente.&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
I sistemi di compensazione della potenza reattiva dinamica (senza ritardi) (cioè con condensatori a tiristori) possono prevenire o ridurre le perturbazioni di rete come brevi cadute di tensione e fliker.&amp;nbsp;&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
Nel linguaggio tecnico internazionale a volte vengono comunemente utilizzati i seguenti termini: &quot;correzione dinamica del fattore di potenza a commutazione rapida&quot;, &quot;compensazione dinamica&quot; o &quot;sistema di correzione del fattore di potenza dinamico&quot;.&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
L&#39;attrezzatura convenzionale con contattori d&#39;aria crea correnti di spunto transitorie che non solo influenzano i componenti di compensazione, ma possono anche portare a danni e perturbazioni (o distorsioni) alla rete elettrica. I compensatori dinamici del fattore di potenza in tempo reale generalmente si attivano e si spengono durante l&#39;attraversamento della corrente zero, evitando così interferenze transitorie.&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEib8fK2AiKVL1gFADFei_h4MdAgGQrglnfMiLHxpWCA1H5cyiklRKoKgaDs65e35AKEKyYjM6JIOXBq3YKgFhb2GAD8NpqLuv_iEz7ZKOuTRZCMI-uUlL3Hrcab17A4az0KTIOE-7bjrwM/s1600/Screen+Shot+2019-02-10+at+13.52.48.png&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;421&quot; data-original-width=&quot;419&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEib8fK2AiKVL1gFADFei_h4MdAgGQrglnfMiLHxpWCA1H5cyiklRKoKgaDs65e35AKEKyYjM6JIOXBq3YKgFhb2GAD8NpqLuv_iEz7ZKOuTRZCMI-uUlL3Hrcab17A4az0KTIOE-7bjrwM/s320/Screen+Shot+2019-02-10+at+13.52.48.png&quot; width=&quot;318&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
La Figura mostra il principio di un sistema di compensazione della potenza reattiva dinamica con tiristori.&amp;nbsp;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;
I tiristori sono adatti per la commutazione di carichi capacitivi, esempi di applicazioni tipiche sono le seguenti:&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;/div&gt;
&lt;o:p&gt;&lt;/o:p&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;o:p&gt;&lt;/o:p&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;ul&gt;
&lt;li&gt;Gru&lt;/li&gt;
&lt;li&gt;Ascensori&lt;/li&gt;
&lt;li&gt;Saldatrici a punti&amp;nbsp;&lt;/li&gt;
&lt;li&gt;Processi di produzione sensibili (ad esempio l&#39;industria dei semiconduttori)&lt;/li&gt;
&lt;/ul&gt;
</description><link>http://impiantisticaelettrica.blogspot.com/2019/02/compensazione-dinamica-del-fattore-di.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEib8fK2AiKVL1gFADFei_h4MdAgGQrglnfMiLHxpWCA1H5cyiklRKoKgaDs65e35AKEKyYjM6JIOXBq3YKgFhb2GAD8NpqLuv_iEz7ZKOuTRZCMI-uUlL3Hrcab17A4az0KTIOE-7bjrwM/s72-c/Screen+Shot+2019-02-10+at+13.52.48.png" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-1241503676460956211</guid><pubDate>Fri, 13 Oct 2017 02:27:00 +0000</pubDate><atom:updated>2020-10-13T04:54:57.576+02:00</atom:updated><title>Ridurre i costi aziendali regolando il Fattore di Potenza</title><description>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span color=&quot;rgba(0, 0, 0, 0.75)&quot; style=&quot;background-color: white; font-family: verdana; text-align: left;&quot;&gt;Il Fattore di Potenza determina come utilizziamo l&#39;energia elettrica che acquistiamo, ed è definito come il rapporto tra la Potenza Attiva e la Potenza Apparente (kW/kVA).&lt;/span&gt;&lt;/div&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;background: white; line-height: normal; margin-bottom: 0cm; vertical-align: baseline;&quot;&gt;&lt;span style=&quot;font-family: verdana; font-size: medium;&quot;&gt;Correggere il fattore di potenza a valori accettabili
(che come regola generale potremmo indicare intoro al 90%) permette di ridurre
le perdite di energia sugli impianti, con un conseguente saving
economico.&amp;nbsp;Riducendo le perdite si riducono di conseguenza anche le
emissioni di CO2.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span color=&quot;rgba(0, 0, 0, 0.75)&quot; style=&quot;background-color: white; font-family: verdana; font-size: medium; text-align: left;&quot;&gt;



&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;background: white; line-height: normal; mso-margin-bottom-alt: auto; mso-margin-top-alt: auto; vertical-align: baseline;&quot;&gt;&lt;span style=&quot;font-family: verdana; font-size: medium;&quot;&gt;Il modo migliore e più economico per correggere il Fattore di Potenza è
mediante l&#39;utilizzo di Capacità ad inserzione automatica, di solito installare
a livello di Power Center o MCC&lt;/span&gt;&lt;span style=&quot;font-family: &amp;quot;Times New Roman&amp;quot;,serif; font-size: 13.5pt; mso-fareast-font-family: &amp;quot;Times New Roman&amp;quot;; mso-fareast-language: IT;&quot;&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;&lt;div class=&quot;slate-resizable-image-embed slate-image-embed__resize-full-width&quot; style=&quot;background: rgb(255, 255, 255); border: 0px; box-sizing: inherit; clear: both; color: rgba(0, 0, 0, 0.75); font-family: &amp;quot;Source Serif Pro&amp;quot;, serif; font-size: 2rem; line-height: 3.2rem; margin: 3.2rem 0px; padding: 0px; position: relative; vertical-align: baseline;&quot;&gt;&lt;img alt=&quot;Fattore di Potenza = Potenza Attiva / Potenza Apparente&quot; data-li-src=&quot;https://media-exp1.licdn.com/dms/image/C4D12AQG5BmY3Ft3s6Q/article-inline_image-shrink_1000_1488/0?e=1608163200&amp;amp;v=beta&amp;amp;t=tbBrr3Zc52rVC3i4rNHd3sPJSeYehwC_AZIFYNDiaGw&quot; data-media-urn=&quot;&quot; src=&quot;https://media-exp1.licdn.com/dms/image/C4D12AQG5BmY3Ft3s6Q/article-inline_image-shrink_1000_1488/0?e=1608163200&amp;amp;v=beta&amp;amp;t=tbBrr3Zc52rVC3i4rNHd3sPJSeYehwC_AZIFYNDiaGw&quot; style=&quot;background: transparent; border: 0px; box-sizing: inherit; font-size: 20px; height: auto; margin: 0px; max-width: 100%; outline: 0px; padding: 0px; vertical-align: baseline; width: 744px;&quot; /&gt;&lt;/div&gt;&lt;div style=&quot;background: rgb(255, 255, 255); border: 0px; box-sizing: inherit; color: rgba(0, 0, 0, 0.75); line-height: 3.2rem; margin: 3.2rem 0px; padding: 0px; text-align: left; vertical-align: baseline;&quot;&gt;&lt;br /&gt;&lt;/div&gt;&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-weight: normal;&quot;&gt;&lt;span style=&quot;font-family: inherit; font-size: medium;&quot;&gt;&amp;nbsp;I&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2020/10/ridurre-i-costi-aziendali-regolando-il.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-6362270783665485014</guid><pubDate>Sat, 10 May 2014 19:02:00 +0000</pubDate><atom:updated>2014-05-10T23:47:44.894+02:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">media tensione</category><category domain="http://www.blogger.com/atom/ns#">PD</category><category domain="http://www.blogger.com/atom/ns#">scarica parziale</category><category domain="http://www.blogger.com/atom/ns#">scariche parziali</category><title>Scariche Parziali</title><description>&lt;div style=&quot;text-align: justify;&quot;&gt;
Le Scariche Parziali (in Inglese PD - Partial Discharge) sono una rottura dielettrica localizzata di una piccola porzione di isolante. Mentre una scarica corona è solitamente rivelata da una luce relativamente stabile visibile in aria, le scariche parziali in quanto all&#39;interno sistema isolante non sono visibili.&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
Le Scariche Parziali di &amp;nbsp;solito si generano nei vuoti, incrinature o inclusioni all&#39;interno di un solido dielettrico, alle interfacce conduttore-dielettrico all&#39;interno dielettrici solidi o liquidi, oppure in bolle all&#39;interno dielettrici liquidi.&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
Le Scariche parziali possono generarsi in condizioni di lavoro normali in apparecchiature ad Alta e Media Tensione in cui la condizione di isolamento è deteriorata con l&#39;età, installazione impropria o stress Termico o Elettrico.&amp;nbsp;&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
Un corretto monitoraggio dello stato delle scariche parziali permette di individuare con anticipo i componenti a rischio di guasto negli impianti in Media ed Alta Tensione, minimizzando i costi di manutenzione degli impianti.&amp;nbsp;&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
Le seguenti immagini mostrano dei guasti provocati da Scariche Parziali che nel tempo sono degenerate in vere e proprie scariche distruttive.&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjM5oFRLvf7hlQVbbdPQ3vIbD9r6BwVXTPbfFPDFxW4993odh0kwWdC6DZ5XuYszoUlz6wzVZrxU7DkHGgvRz36f6bfRMfaINc81tWZzKWFlO8XJLejw4bNYMpRFIEndctyL9IWrAvUB-cc/s1600/PD7.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjM5oFRLvf7hlQVbbdPQ3vIbD9r6BwVXTPbfFPDFxW4993odh0kwWdC6DZ5XuYszoUlz6wzVZrxU7DkHGgvRz36f6bfRMfaINc81tWZzKWFlO8XJLejw4bNYMpRFIEndctyL9IWrAvUB-cc/s1600/PD7.jpg&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjKYDZt89BOXeN59Ltmn6HQrcOtRQLrklPgI3FAQQScozwp4DbqyAKaEqVPl12l7v3Ns1BgI1MwaeDSGjF6BSdB-t4nBsdLhpqR-fqTpAYYFtNzTLaxpBgIfDg1vmrStGGlHBC7N_76W-5y/s1600/PD5.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjKYDZt89BOXeN59Ltmn6HQrcOtRQLrklPgI3FAQQScozwp4DbqyAKaEqVPl12l7v3Ns1BgI1MwaeDSGjF6BSdB-t4nBsdLhpqR-fqTpAYYFtNzTLaxpBgIfDg1vmrStGGlHBC7N_76W-5y/s1600/PD5.jpg&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjN4SnOIC7Z68ZFvBKztGBbRXEFSYyt_dp5iFbiDWx5zGKO0fsAHhc2_ildAcv4pumgEn66RcfQt-R_ZjEqUwtYZYYdrn-OTipT9B8n3YapCMBPgB1junjDzEfW2EvRnT1PPsOhcj7h-Fcd/s1600/PD8.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjN4SnOIC7Z68ZFvBKztGBbRXEFSYyt_dp5iFbiDWx5zGKO0fsAHhc2_ildAcv4pumgEn66RcfQt-R_ZjEqUwtYZYYdrn-OTipT9B8n3YapCMBPgB1junjDzEfW2EvRnT1PPsOhcj7h-Fcd/s1600/PD8.jpg&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: justify;&quot;&gt;
Data l&#39;importanza e la complessità della materia trattata è mia intenzione ritornare sull&#39;argomento con approfondimenti specifici sia sulla teoria che sulla misura (con riferimento alle mie innumerevoli esperienze professionali) delle Scariche parziali in apparecchiature elettriche in &amp;nbsp;Media ed Alta Tensione.&amp;nbsp;&lt;/div&gt;
</description><link>http://impiantisticaelettrica.blogspot.com/2014/05/scariche-parziali.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjM5oFRLvf7hlQVbbdPQ3vIbD9r6BwVXTPbfFPDFxW4993odh0kwWdC6DZ5XuYszoUlz6wzVZrxU7DkHGgvRz36f6bfRMfaINc81tWZzKWFlO8XJLejw4bNYMpRFIEndctyL9IWrAvUB-cc/s72-c/PD7.jpg" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4571874543681791234</guid><pubDate>Thu, 23 Sep 2010 21:39:00 +0000</pubDate><atom:updated>2011-02-13T12:12:21.922+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">progettazione sottostazioni</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Sottostazioni di Centrale, criteri di progetto</title><description>&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Nel progetto di massima di una centrale elettrica, una volta determinata la potenza che avrà l’impianto e le caratteristiche generali del macchinario, si procede alla scelta dello schema unifilare dei circuiti principali.&lt;/p&gt;    &lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Ogni impianto ha delle caratteristiche peculiari, per esempio le modalità di inserimento nella rete.Ci sono tuttavia, delle considerazioni che vanno comenque fatte durante la fase di progettazione preliminare:&lt;/p&gt;  &lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Symbol;&quot;&gt;&lt;span&gt;&lt;span style=&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;i&gt;&lt;u&gt;Apparecchi di sezionamento ed interruzione:&lt;/u&gt;&lt;/i&gt;&lt;/b&gt; Gli interruttori costano molto di più dei sezionatori, vanno quindi installati solo in quei punti dove sono strettamente necessari (protezione macchine e circuiti, uscite linea, collegamenti tra linee indipendenti). I sezionatori vanno installati in tutti i punti dove si rende necessario un sezionamento visibile (ex per manutenzione, isolamento parti di linea..).&lt;/p&gt;    &lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Symbol;&quot;&gt;&lt;span&gt;&lt;span style=&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;i&gt;&lt;u&gt;Collegamenti tipici:&lt;/u&gt;&lt;/i&gt;&lt;/b&gt; La scelta dello schema di collegamento intervengono 2 fattori, le esigenze di esercizio ed il costo dell’impianto. La necessità di mantenere la continuità del servizio obbligherà a studiare lo schema in modo da minimizzare la possibilità di interruzioni; il costo e la complessità dell’impianto dovranno altresì essere contenuti.&lt;span&gt;  &lt;/span&gt;A seconda dell’importanza dell’impianto, potranno prevalere esigenze di sicurezza di esercizio o quelle di economia di costo (tra loro palesemente contrastanti ). Gli schemi unifilari tipici (ne esiste un ampia letteratura) possono essere divisi in 2 classi: quelli senza trasformazione MT/AT che di solito sono quelli industriali e quelli con trasformatore MT/AT, utilizzati nelle quasi totalità dei casi, per la trasmissione dell’energia. &lt;/p&gt;    &lt;p style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;u&gt;Schemi unifilari tipici:&lt;/u&gt;&lt;/i&gt;&lt;/b&gt; a una sbarra, a sbarra principale e sbarra di traslazione, a 2 sbarre principali, a 2 sbarre principali e 2 interruttori per linea,… ecc ..&lt;br /&gt;&lt;/p&gt;    &lt;p style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;u&gt;Riduttori di misura e scaricatori di sovratensione:&lt;/u&gt;&lt;/i&gt;&lt;/b&gt;&lt;span&gt;  &lt;/span&gt;Il numero dei riduttori dipende dal numero e dall’importanza delle macchine e dalle linee. Gli scaricatori per la proteggere l&#39;apparecchiatura dalle sovratensioni.&lt;br /&gt;&lt;/p&gt;    &lt;p style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;u&gt;Servizi ausiliari:&lt;/u&gt;&lt;/i&gt;&lt;/b&gt; Particolare attenzione richiede la scelta di un adeguato sistema di alimentazione dei servizi ausiliari in corrente alternata. Esistono diverse possibili fonti di alimentazione per loro.&lt;/p&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;  Importantissima è la scelta dei singoli componenti, i quali vanno dimensionati tenendo conto delle correnti di c.c., dei livelli di tensione, dello studio di coordinamento dell’isolamento, dell’analisi dei possibili guasti, della criticità siismica, ecc… ecc..&lt;/div&gt;&lt;span&gt; &lt;/span&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2010/09/progetto-di-sotostazioni-parte-1.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-1675718382023051294</guid><pubDate>Sun, 29 Aug 2010 13:29:00 +0000</pubDate><atom:updated>2011-02-13T12:03:52.522+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">atex</category><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>ATEX .... Atmosfere Esplosive</title><description>&lt;a onblur=&quot;try {parent.deselectBloggerImageGracefully();} catch(e) {}&quot; href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEho410s-TkS7wMcBkxVubBa-vw3-tc3Jbb6DkfnbIB2zN5meeDf1usNHVPlTXRfddPVp2A1rAlIdEEOl5sd2nyPbqydVj9KAUv7LQ-fUXkmM_9Pu1d9lGyceYO-Nnhdto-lK4S6X_Wv71qy/s1600/ATEX_zijkanaalventilator_DBS607Exb.jpg&quot;&gt;&lt;img style=&quot;margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 200px; height: 150px;&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEho410s-TkS7wMcBkxVubBa-vw3-tc3Jbb6DkfnbIB2zN5meeDf1usNHVPlTXRfddPVp2A1rAlIdEEOl5sd2nyPbqydVj9KAUv7LQ-fUXkmM_9Pu1d9lGyceYO-Nnhdto-lK4S6X_Wv71qy/s200/ATEX_zijkanaalventilator_DBS607Exb.jpg&quot; alt=&quot;&quot; id=&quot;BLOGGER_PHOTO_ID_5510826875559668274&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;Gestire la sicurezza contro gli incendi e le esplosioni non si limita ormai al solo utilizzo di prodotti certificati ATEX, in quanto esiste una legislazione che disciplina il funzionamento di tali prodoti all&#39;interno di fabbriche e stabilimenti.&lt;br /&gt;Il rispetto delle normative nelle aree soggette a incendi è stato al centro della direttiva sui prodotto ATEX (94/9/EC).&lt;br /&gt;&lt;br /&gt;I rischi di esplosione devono essere valutati documentati ed aggiornati (direttiva 89/39/EEC), il luogo di lavoro deve essere sicuro e le aree pericolose devono essere classificate e provviste di segnali di allarmi specifici (direttiva 92/58/EEC e ATEX 94/9/EEC).&lt;br /&gt;&lt;br /&gt;Nella valutazione dei rischi derivante dalle atmosfere esplosive occorre tenere conto almeno di:&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Probabilità e durata della presenza di atmosfere esplosive&lt;/li&gt;&lt;li&gt;Probabilità di presenza delle sorgenti di innesco, comprese le cariche elettrostatiche&lt;/li&gt;&lt;li&gt;Caratteristiche delle sostanze utilizzate nell&#39;impianto, processo e possibili interazioni&lt;/li&gt;&lt;li&gt;Entità degli effetti prevedibili&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;E, in seguito al D.Lgs 81/08, deve essere precisato:&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Che i rischi di esplosione sono stati individuati e valutati&lt;/li&gt;&lt;li&gt;Che sono state intraprese misure adeguate per la protezione&lt;/li&gt;&lt;li&gt;Quali sono le aree pericolose&lt;/li&gt;&lt;li&gt;Che i luoghi, le attrezzature ed i dispositivi di allarme sono mantenuti in perfetta efficienza&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2010/08/atex-atmosfere-esplosive.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEho410s-TkS7wMcBkxVubBa-vw3-tc3Jbb6DkfnbIB2zN5meeDf1usNHVPlTXRfddPVp2A1rAlIdEEOl5sd2nyPbqydVj9KAUv7LQ-fUXkmM_9Pu1d9lGyceYO-Nnhdto-lK4S6X_Wv71qy/s72-c/ATEX_zijkanaalventilator_DBS607Exb.jpg" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4745007250712543968</guid><pubDate>Sun, 11 Jul 2010 11:55:00 +0000</pubDate><atom:updated>2011-02-13T12:04:08.071+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">lucci giuseppe</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><category domain="http://www.blogger.com/atom/ns#">sicurezza elettrica</category><title>Sicurezza elettrica e Dlg 81/2008</title><description>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;a onblur=&quot;try {parent.deselectBloggerImageGracefully();} catch(e) {}&quot; href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhUVITPL9X7wqMKuUJS9DZSF0e7sj4KkMBLHAudT_ssijTDPJIV2AxbYHAzcKmvTEp5BfksRWWAO9ow3h5brdcfLlAPihCM_nfGkayBjmhdaSeGOzB8dh7rCjl8fDAxU6V0PmjjTUqM9htb/s1600/1120l.gif&quot;&gt;&lt;img style=&quot;margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 156px; height: 200px;&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhUVITPL9X7wqMKuUJS9DZSF0e7sj4KkMBLHAudT_ssijTDPJIV2AxbYHAzcKmvTEp5BfksRWWAO9ow3h5brdcfLlAPihCM_nfGkayBjmhdaSeGOzB8dh7rCjl8fDAxU6V0PmjjTUqM9htb/s200/1120l.gif&quot; alt=&quot;&quot; id=&quot;BLOGGER_PHOTO_ID_5492617519229380994&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;Con l&#39;entrata in vigore del Testo Unico sulla sicurezza, D. Lgs 81/2008, diviene obbligatorio (art. 82), nel caso di lavori elettrici in tensione, riconoscere l&#39;idoneità dei lavoratori secondo le indicazioni della pertinente normativa tecnica. Nel caso specifico la normativa di riferimento è la norma CEI 11-27, 3° edizione, che fornisce gli elementi essenziali per la formazione degli addetti ai lavori elettrici.&lt;br /&gt;Tale norma prevede che il datore di lavoro attribuisca per iscritto il livello di qualifica ad operare sugli impianti elettrici che può essere di persona esperta (PES), persona avvertita (PAV) ed idonea ai lavori elettrici sotto tensione.&lt;br /&gt;&lt;br /&gt;Fondamentale è l&#39;obbligo (Art. 80 comma 2) per il datore di lavoro di eseguire una  valutazione dei rischi, tenendo in considerazione:&lt;br /&gt;&lt;ol&gt;&lt;li&gt;le condizioni e le caratteristiche specifiche del lavoro, ivi comprese eventuali interferenze&lt;/li&gt;&lt;li&gt;i rischi presenti nell’ambiente di lavoro&lt;/li&gt;&lt;li&gt;tutte le condizioni di esercizio prevedibili&lt;/li&gt;&lt;/ol&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;A seguito della valutazione del rischio elettrico il datore di lavoro adotta le misure tecniche ed organizzative necessarie ad eliminare o ridurre al minimo i rischi presenti, ad individuare i dispositivi diprotezione collettivi ed individuali necessari alla conduzione in sicurezza del lavoro ed a predisporre leprocedure di uso e manutenzione atte a garantire nel tempo la permanenza del livello di sicurezzaraggiunto con l’adozione delle misure di cui al comma 1 dell&#39; articolo 80 D. Lgs 81/2008.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;span style=&quot;font-weight: bold; font-style: italic;&quot;&gt;Le sanzioni previste a carico del datore di lavoro e dei dirigenti, in caso di violazione degli obblighi sopraccitati, sono particolarmente severe: la pena è l&#39;arresto da tre a sei mesi o l&#39;ammenda da 2.500 a 6.400 €.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2010/07/sicurezza-elettrica-e-dlg-812008.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhUVITPL9X7wqMKuUJS9DZSF0e7sj4KkMBLHAudT_ssijTDPJIV2AxbYHAzcKmvTEp5BfksRWWAO9ow3h5brdcfLlAPihCM_nfGkayBjmhdaSeGOzB8dh7rCjl8fDAxU6V0PmjjTUqM9htb/s72-c/1120l.gif" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4010091800952441698</guid><pubDate>Wed, 02 Jun 2010 10:16:00 +0000</pubDate><atom:updated>2011-02-13T12:05:06.297+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">dimensionamento trasformatore</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">potenza di cortocircuito</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Scelta del Trasformatore: Parte 1</title><description>&lt;a onblur=&quot;try {parent.deselectBloggerImageGracefully();} catch(e) {}&quot; href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiMnZxfnw6H9bJ3ZOJaDBQjuKBkLxAnVrnCJ3YNRPwxdH3qrbM796Kds1pb2cTndipCngu94sKkK96-Ev8k2fwQtJjeGtm9WXBG14IpBou-2-dB19AIylADcmbFodGrgcoP81Hoz44g-MT8/s1600/110KV-Power-Transformer.jpg&quot;&gt;&lt;img style=&quot;margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 199px; height: 200px;&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiMnZxfnw6H9bJ3ZOJaDBQjuKBkLxAnVrnCJ3YNRPwxdH3qrbM796Kds1pb2cTndipCngu94sKkK96-Ev8k2fwQtJjeGtm9WXBG14IpBou-2-dB19AIylADcmbFodGrgcoP81Hoz44g-MT8/s200/110KV-Power-Transformer.jpg&quot; alt=&quot;&quot; id=&quot;BLOGGER_PHOTO_ID_5478123997570205746&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;Nella scelta del trasformatore per un impianto industriale, è fondamentale considerare il suo contributo alla potenza di cortocircuito dell&#39;impianto; perchè in base ai valori di tale potenza si dimensionano i cavi e le apparecchiature principali (Quadri, interruttori, sbarre, ecc..). Tale potenza ha un notevole impatto sui costi, il progettista deve quindi limitare questo valore.&lt;br /&gt;&lt;br /&gt;Quando si dimensiona un impianto, è opportuno calcolare la tensione di cortocircuito dei trasformatori, in modo da limitare la corrente di cortocircuito. Conviene procedere per approssimazioni successive: considerando inizialmente, per semplicità ed a favore della sicurezza, infinita la potenza di cortocircuito della rete di alimentazione, e valutare quindi il contributo dei trasformatori e dei motori.&lt;br /&gt;&lt;br /&gt;Se i valori ottenuti sono superiori di quelli previsti dalle norme (CEI 14-12; 14-13), si procede con un calcolo più preciso, tenendo presente il valore della potenza di cortocircuito della rete di alimentazione ed il contributo dato dai cavi e dalle linee che costituiscono l&#39;impianto.&lt;br /&gt;&lt;br /&gt;Questi calcoli permettono in pratica di:&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Ridurre la corrente di cortocircuito dell&#39;impianto&lt;br /&gt;&lt;/li&gt;&lt;li&gt;Ridurre i costi dell&#39;apparecchiatura elettrica&lt;/li&gt;&lt;li&gt;Ridurre i tempi ed i costi di manutenzione dell&#39;impianto&lt;/li&gt;&lt;li&gt;Ridurre i rischi per le persone&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2010/06/scelta-del-trasformarotre-parte-1.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiMnZxfnw6H9bJ3ZOJaDBQjuKBkLxAnVrnCJ3YNRPwxdH3qrbM796Kds1pb2cTndipCngu94sKkK96-Ev8k2fwQtJjeGtm9WXBG14IpBou-2-dB19AIylADcmbFodGrgcoP81Hoz44g-MT8/s72-c/110KV-Power-Transformer.jpg" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-2374841186105472670</guid><pubDate>Sat, 06 Feb 2010 10:07:00 +0000</pubDate><atom:updated>2011-02-13T12:05:36.396+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">qualifica sismica</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><category domain="http://www.blogger.com/atom/ns#">sismico</category><category domain="http://www.blogger.com/atom/ns#">sistema elettrico</category><category domain="http://www.blogger.com/atom/ns#">terremoto</category><title>Sistema Elettrico e Qualifica sismica</title><description>&lt;a onblur=&quot;try {parent.deselectBloggerImageGracefully();} catch(e) {}&quot; href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2KwWT8T2ZvDFKwJEy1BPF8nN571LgzVRkSSnhaLTxb_HKue_7OtJAVqb_VML9xiDqv4e1lLQ8xyT2DnCoyxq7s5kGrib8CFR-AHtXDlkvpiEcXHL0XpPNA1BmsFzl9BBjxIu6CwfSsDvj/s1600/Sisma+Sott.JPG&quot;&gt;&lt;img style=&quot;margin: 0pt 0pt 10px 10px; float: right; cursor: pointer; width: 180px; height: 200px;&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2KwWT8T2ZvDFKwJEy1BPF8nN571LgzVRkSSnhaLTxb_HKue_7OtJAVqb_VML9xiDqv4e1lLQ8xyT2DnCoyxq7s5kGrib8CFR-AHtXDlkvpiEcXHL0XpPNA1BmsFzl9BBjxIu6CwfSsDvj/s200/Sisma+Sott.JPG&quot; alt=&quot;&quot; id=&quot;BLOGGER_PHOTO_ID_5455934859926667922&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div align=&quot;justify&quot;&gt;Una fornitiura stabile di elettricità è un bisogno necessario nei paesi industrializzati, se il sistema elettrico venisse danneggiato dal terremoto, è inevitabile la mancata erogazione di energia per un lungo periodo di tempo, con conseguenze disastrose (Economiche e Sociali).&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;A causa della particolare struttura architettonica, le Sottostazioni sono le parti del sistema elettrico a rischio più eleveto per quanto riguarda il terremoto (Senza considerare le centrali nucleari, che meritano una trattazione a parte, data la complessità dell&#39;argomento).&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;E&#39; quindi fondamentale considerare le caratteristiche dei componenti del sistema (Isolatori, Scaricatori, Trasformatori, Quadri elettrici, ecc..) in relazione al pericolo sismico; che dipende dalla zona di installazione e dal tipo di impianto.&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt; &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Esiestono norme (IEC, IEEE, CEI,....) specialistiche che permettono al progettista di individuare l&#39;apparecchiatura adeguata per ogni situazione. &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;La normativa individua e definisce le procedure di &lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Calcolo&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Analisi dinamica&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Collaudo&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;E&#39; quindi nesessario effettuare uno studio per verificare, in fase di progetto, quale norma di riferimento va considerata rispetto al pericolo sismico.&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2010/02/sistema-elettrico-e-qualifica-sismica.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2KwWT8T2ZvDFKwJEy1BPF8nN571LgzVRkSSnhaLTxb_HKue_7OtJAVqb_VML9xiDqv4e1lLQ8xyT2DnCoyxq7s5kGrib8CFR-AHtXDlkvpiEcXHL0XpPNA1BmsFzl9BBjxIu6CwfSsDvj/s72-c/Sisma+Sott.JPG" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4892754147018616381</guid><pubDate>Thu, 12 Nov 2009 21:36:00 +0000</pubDate><atom:updated>2011-02-13T12:06:34.779+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">Protezioni Fulmini</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Protezione contro i Fulmini</title><description>&lt;div align=&quot;justify&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3pHxiDlJ1gMdeJIGzovwVjb-6K_cYKfffslyNYXac3l9euAKkZuwJlJRcoZ5dqOXSNYiAAQsNPCoagsM75a8AMnp4f7UGNzTvKYQ74dJe4pmiHvdYDjSGEJzrbzihbO79b3VliuN11oKc/s1600-h/electrical-storm1.jpg&quot;&gt;&lt;img id=&quot;BLOGGER_PHOTO_ID_5403334461869420018&quot; style=&quot;margin: 0px 10px 10px 0px; float: left; width: 320px; height: 182px;&quot; alt=&quot;&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3pHxiDlJ1gMdeJIGzovwVjb-6K_cYKfffslyNYXac3l9euAKkZuwJlJRcoZ5dqOXSNYiAAQsNPCoagsM75a8AMnp4f7UGNzTvKYQ74dJe4pmiHvdYDjSGEJzrbzihbO79b3VliuN11oKc/s320/electrical-storm1.jpg&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;La valutazione del rischio dovuto ai Fulmini che posono interagire con un Impianto Elettrico, consente al progettista di stabilire se tale protezione sia necessaria. &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;I danni causati dal Fulmine comportano rischi di diverso tipo:&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;-&lt;em&gt;Perdite di vite Umane&lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;-Perdite Economiche (Produzione, beni, servizi )&lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;-Perdite di patrimoni Culturali&lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;Normativa di riferimento:&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Sono entrate in vigore le Norme CEI EN 62305-1-2-3-4 (CEI 81-10/1, CEI 81-10/2, CEI 81-10/3, 81-10/4), che sostituiscono le vecchie norme, ormai superate CEI 81-1, CEI 81-4.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;La decisione di adottare quindi misure di protezione deve essere presa dal progettista confrontando, per ogni tipo di rischio, il rischio dovuto al fulmine con il rischio tollerabile. &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/11/protezione-contro-i-fulmini.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3pHxiDlJ1gMdeJIGzovwVjb-6K_cYKfffslyNYXac3l9euAKkZuwJlJRcoZ5dqOXSNYiAAQsNPCoagsM75a8AMnp4f7UGNzTvKYQ74dJe4pmiHvdYDjSGEJzrbzihbO79b3VliuN11oKc/s72-c/electrical-storm1.jpg" height="72" width="72"/><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4629375486119125119</guid><pubDate>Sun, 08 Nov 2009 17:04:00 +0000</pubDate><atom:updated>2011-02-13T12:06:50.545+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">CEI 64-8</category><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><category domain="http://www.blogger.com/atom/ns#">sezione cavo</category><title>Sezioni minime dei Conduttori</title><description>&lt;div align=&quot;justify&quot;&gt;La norma CEI 64-8/5 impone delle &lt;strong&gt;&lt;em&gt;sezioni minime per i conduttori&lt;/em&gt;&lt;/strong&gt;, che vanno comunque rispettate, indipendentemente dai risultati dei calcoli. Tali valori sono di seguito elencati:&lt;/div&gt;&lt;br /&gt;&lt;ol&gt;&lt;br /&gt;&lt;li&gt;CAVI (Condutture fisse):&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;em&gt;Circuiti di Potenza&lt;/em&gt;: 1,5 mm^2 in Rame oppure 16 mm^2 in Alluminio&lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;em&gt;Segnalazione e comando&lt;/em&gt;: 0,5 mm^2 in Rame (*)&lt;/li&gt;&lt;/ul&gt;&lt;/li&gt;&lt;br /&gt;&lt;br /&gt;&lt;li&gt;CONDUTTORI NUDI (Condutture fisse):&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;em&gt;Circuiti di Potenza&lt;/em&gt;: 10 mm^2 in Rame oppure 16 mm^2 in Alluminio &lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;em&gt;Segnalazione e comando&lt;/em&gt;: 4 mm^2 in Rame&lt;/li&gt;&lt;br /&gt;&lt;/ul&gt;&lt;/li&gt;&lt;br /&gt;&lt;br /&gt;&lt;li&gt;CAVI (Condutture mobili con cavi flessibili):&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;&lt;ul&gt;&lt;li&gt;&lt;em&gt;Per aparecchiatura Specifica&lt;/em&gt;: Vale la Norma CEI corrispondente&lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;em&gt;Per qualsiasi altra applicazione&lt;/em&gt;: 0,75 mm^2 in Rame (**)&lt;/li&gt;&lt;/ul&gt;&lt;/ol&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;br /&gt;L&#39;eventuale conduttore di Neutro deve avere la stessa sezione delle fasi: &lt;/p&gt;&lt;ol&gt;&lt;li&gt;Nei circuiti Monofase a 2 fili, qualunque sia la sezione dei conduttori&lt;/li&gt;&lt;li&gt;Nei circuiti Polifase se la sezione delle fasi è inferiore o uguale a 16 mm^2 in Rame oppure a 25 mm^2 in Alluminio&lt;/li&gt;&lt;/ol&gt;&lt;p align=&quot;justify&quot;&gt;E&#39; ammessa una sezione inferiore del conduttore di Neutro solo nel caso in cui le sezioni dei conduttori di fase siano maggiori di 16 mm^2 in Rame e di 25 mm^2 in Alluminio, e siano soddisfatte le seguenti condizioni:&lt;/p&gt;&lt;ol&gt;&lt;li&gt;La Imax prevista sul neutro (Armoniche comprese) non sia superiore a quella ammessa dalla sezione considerata&lt;/li&gt;&lt;li&gt;La sezione del conduttore di neutro sia almeno uguale a 16 mm^2 in Rame oppure 25 mm^2 in Alluminio&lt;/li&gt;&lt;/ol&gt;&lt;p align=&quot;justify&quot;&gt;Note:&lt;br /&gt;(*) Nei circuiti di segnalazione e comando destinati ad apparecchiature elettroniche è ammessa una sezione minima di 0,1 mm^2.&lt;br /&gt;(**) Per i cavi flessibili multipolari che contengono 7 o più anime vale la nota precedente (*)&lt;br /&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/11/sezioni-minime-dei-conduttori.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-8207407367571707640</guid><pubDate>Thu, 01 Oct 2009 20:27:00 +0000</pubDate><atom:updated>2011-02-13T12:07:11.311+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><category domain="http://www.blogger.com/atom/ns#">sezione cavo</category><title>Scelta della Sezione del cavo</title><description>&lt;div align=&quot;justify&quot;&gt;Durante la fase di progettazione di un impianto, fondamentale è la scelta della sezione dei cavi elettrici. I parametri che influenzano la scelta della sezione sono due:&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;strong&gt;La portata di corrente:&lt;/strong&gt;&lt;/em&gt; Influenzata da numerosi parametri, con una forte dipendenza dallo scambio termico; esistono delle tabelle dalle quali è possibile risalire alla portata di un cavo considerando il tipo di cavo e le condizioni di posa.&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;strong&gt;La caduta di tensione (c.d.t.):&lt;/strong&gt;&lt;/em&gt; Valore imposto dalla normativa oppure da motivi funzionali.&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;Per determinare le sezioni dei cavi, conviene fare riferimento alle portate dei cavi tabellate (vedi CEI-UNEL 35024/1 e CEI-UNEL 35026).&lt;br /&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;La portata di corrente, in casi molto particolari, può essere calcolata utilizzando dei pacchetti software specifici, che permettono di valutare in maniera abbanstanza fedele l&#39;effettiva portata di corrente, date le condizioni di posa.&lt;br /&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;em&gt;Considerando il costo del rame, è fondamentale evitare inutili sovraddimensionamenti, perchè aumenterebbe solo il costo dell&#39;impianto, senza apportare reali benefici. &lt;/em&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;em&gt;&lt;/em&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/10/scelta-del-cavo.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-1731190748554661211</guid><pubDate>Fri, 25 Sep 2009 19:19:00 +0000</pubDate><atom:updated>2011-02-13T12:07:25.360+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">potenza convenzionale</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Potenza Convenzionale</title><description>&lt;div align=&quot;justify&quot;&gt;Nel dimensionamento di un impianto è fondamentale conoscere il valore, in termini di Potenza Attiva, del carico da alimentare. Di solito non è quasi mai dato al progettsta un valore esatto della potenza da considerare.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;Si ricorre allora alla detrminazione della &lt;strong&gt;&lt;em&gt;Potenza Convenzionale&lt;/em&gt;&lt;/strong&gt;, &lt;em&gt;ovvero si fa una stima della quantità di energia richiesta dal carico. &lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;Per valutare quindi la potenza convenzionale è necessario fissare diversi parametri che, in base al tipo di impianto, permettono di effettuare una stima realistica, evitando inutili sovraddimensionamenti:&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Fattore di utilizzazione (Ku)&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Fattore di contemporaneità (Kc)&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Rendimenti delle apparecchiature &lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Caratteristiche del carico &lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Se si considerano gli impianti industriali, che di solito comprendono numerosi carichi, anche molto elevati, appare subito evidente che non conviene dimensionare l&#39;impianto per il massimo della potenza richiesta da ogni singolo carico considerando un funzionamento contemporaneo di tutti gli apparecchi utilizzatori.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;strong&gt;&lt;em&gt;&lt;/em&gt;&lt;/strong&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;br /&gt;Aumenterebbero inutilmente i costi di realizzazione dell&#39;impianto e gli oneri di manutenzione, che sono a carico del committente. &lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt; &lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt; &lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt; &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/potenza-convenzionale.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-1791521021831834325</guid><pubDate>Sun, 20 Sep 2009 11:26:00 +0000</pubDate><atom:updated>2011-02-13T12:07:39.228+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Specifica Tecnica</title><description>&lt;div align=&quot;justify&quot;&gt;La definizione di &lt;strong&gt;&lt;em&gt;Specifica Tecnica&lt;/em&gt;&lt;/strong&gt; da art.1.1 Dir. 83/189 CEE è la seguente:&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;br /&gt;&quot;Specificazione contenuta in un documento che definisce le caratteristiche richieste di un prodotto, quali i livelli di qualità o di proprietà di utilizzazione, la sicurezza, le dimensioni, comprese le prescrizioni applicabili a un prodotto per quanto concerne la terminologia, i simboli, le prove e i metodi di prova, l&#39;imballaggio, la marchiatura e l&#39;etichettatura&quot;.&lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;La Specifica Tecnica è quindi un documento che viene prodotto per far si che una determinata apparecchiatura (Quadro elettrico, Interruttore, Isolatore, ecc.. ) sia idonea a svolgere una determinata funzione. &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;La Specifica Tecnica è fondamentale per la progettazione esecutiva e la fornitura di un prodotto che dovrà essere utilizzato in un impianto. Alcune informazioni fondamentali, che vanno sempre riportate nella specifica tecnica sono:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Prestazioni&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Caratteristiche Ambientali&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Modalità di prova e collaudo&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Norme tecniche di riferimento&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Criteri di accettabilità&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;........&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;Le informazioni da inserire dipendono dal tipo di prodotto e dalla sua applicazione, sta al progettista valutare, caso per caso, come impostare tale documento.&lt;/p&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/specifica-tecnica.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-422486329987722784</guid><pubDate>Wed, 16 Sep 2009 18:10:00 +0000</pubDate><atom:updated>2011-02-13T12:08:53.488+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">potenza di cortocircuito</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Potenza di Cortocircuito</title><description>&lt;div align=&quot;justify&quot;&gt;La &lt;em&gt;Potenza di Cortocircuito (Pcc)&lt;/em&gt; è un parametro fondamentale per la progettazione di un impianto elettrico; la conoscenza di tale parametro diventa sempre più importante al crescere delle dimensioni dell&#39;impianto. Nel punto di consegne dell&#39;energia, è opportuno conoscere:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;La Potenza di Cortocircuito massima:&lt;/em&gt;&lt;/strong&gt; utilizzata per il dimensionamento di quadri, interruttori, cavi, ecc. &lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;La Potenza di Cortocircuito minima&lt;/em&gt;:&lt;/strong&gt; utilizzata per determinare la caduta di tensione provocata dall&#39;avviamento di grossi motori e la distorsione armonica della tensione.&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;Dal punto di vista progettuale i valori di Pcc max e Pcc min hanno i seguenti effetti: &lt;strong&gt;&lt;em&gt;il costo dell&#39;impianto cresce all&#39;aumentare della Pcc max mentre la caduta di tensione e la distorsione armonica della tensione diminuiscono all&#39;aumentare della Pcc min.&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;Appare subito chiara l&#39;esigenza di minimizzare la Pcc max ed aumentare la Pcc min; è quindi compito del progettista scegliere le tensioni di cortocircuito dei trasformatori in modo da ottimizzare il sistema elettrico ottenendo le migliori prestazioni al minimo costo.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;Questi valori, devono essere forniti al progettista dall&#39;ente distributore dell&#39;energia.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/potenza-di-cortocircuito.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4878599337919610722</guid><pubDate>Sat, 12 Sep 2009 12:42:00 +0000</pubDate><atom:updated>2011-02-13T12:09:13.817+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">controversie legali</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Controversie Legali e Transitori Elettrici</title><description>&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;L&#39; analisi dei transitori elettrici può essere utilizzata nelle Controversie Legali, al fine di stabilire le effettive cause di un determinato incidente.&lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;Considerando, per esempio, un apparecchiatura elettrica (Interruttore, Trasformatore, Capacità, ecc), è possibile capire se un guasto è stato provocato dal dispositivo di protezione oppure dall&#39;apparecchiatura stessa. &lt;strong&gt;&lt;em&gt;&lt;br /&gt;&lt;br /&gt;Informazione che, ai fini Legali, risulta fondamentale per l&#39;attribuzione delle responsabilità.&lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;&lt;a href=&quot;http://www.sandc.com/services/pss-as_switchingtransient.asp&quot;&gt;&lt;strong&gt;&lt;em&gt;Switching Transient Studies&lt;/em&gt;&lt;/strong&gt;&lt;/a&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/controversie-legali-e-transitori.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-2051833005720736105</guid><pubDate>Fri, 11 Sep 2009 18:53:00 +0000</pubDate><atom:updated>2011-02-13T12:09:44.720+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">autorità energia elettrica e gas</category><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Autorità per l&#39; Energia Elettrica e il Gas</title><description>&lt;div align=&quot;justify&quot;&gt;L&#39;Autorità per l&#39;energia elettrica e il gas è un&#39;autorità indipendente istituita con la legge 14 novembre 1995, n. 481 con funzioni di regolazione e di controllo dei settori dell&#39;energia elettrica e del gas.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Quali sono le sue finalità generali?&lt;br /&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;br /&gt;L&#39;Autorità ha il compito di perseguire le finalità indicate dalla legge n. 481 del 1995 con cui si vuole &quot;garantire la promozione della concorrenza e dell&#39;efficienza&quot; nei settori dell&#39;energia elettrica e del gas, nonché &quot;assicurare adeguati livelli di qualità&quot; dei servizi.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Le competenze dell&#39;autorità sono quindi e seguenti:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Fissa le Tariffe Elettriche&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Qualità del servizio&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Forme di mercato&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Concorrenza&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Concessioni o autorizzazioni&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Verifica e controllo&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Reclami ed istanze&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;E&#39; quindi di fondamentale, per chi opera in ambito elettrico, essere sempre aggiornati ed informati sui provvedimenti emanati da tale organismo.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;I benefici possono essere molteplici: dalla possibilità di usufruire di eventuli vantaggi legislativi, alla possibilità di ottenere rimborsi dai fornitori di energia elettrica alla velocizzazione di pratiche burocratiche.&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;a href=&quot;http://www.autorita.energia.it/&quot;&gt;http://www.autorita.energia.it/&lt;/a&gt;&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;/em&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/autorita-per-l-energia-elettrica-e-gas.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-5118813929701611933</guid><pubDate>Wed, 09 Sep 2009 17:34:00 +0000</pubDate><atom:updated>2011-02-13T12:10:03.483+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione elettrica</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><category domain="http://www.blogger.com/atom/ns#">Transitorio elettrico</category><title>Vantaggio economico dello studio dei transitori nei sistemi elettrici</title><description>&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;Effettuare uno studio preliminare dei transitori elettrici in fase di progettazione &lt;strong&gt;offre dei vantaggi economici enormi&lt;/strong&gt;&lt;/em&gt;, sia per la realizzazione di impianti industriali che per la fabbricazione di apparecchiatura elettrica quale: Interruttori, Trasformatori, Motori, Isolatori passanti, Induttanze, ecc, ecc.... &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;Purtroppo questa fase viene di solito trascurata, in quanto ha bisogno di personale altamente specializzato, e non costituisce un onere di legge. &lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Il vantaggio economico che si ottiene effettuando uno studio preliminare dei transitori elettrici è direttamente proporzionale al costo ed alla complessità dell&#39;impianto, considerando invece l&#39;apparecchiatura elettrica, il vantaggio economico che ne consegue è proprzionale al volume di produzione dell&#39;apparecchiatura stessa.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Studiare il transitorio permette quindi di ottimizzare la progettazione, evitando inutili sovraddimensionamenti che vanno solo ad aumentare i costi. I vantaggi risultano i seguenti:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;strong&gt;Per il committente:&lt;/strong&gt;&lt;/em&gt; Il costo più basso&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;strong&gt;Per l&#39;appaltatore:&lt;/strong&gt;&lt;/em&gt; Maggiore competitività nelle gare di appalto&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;&lt;strong&gt;Per il costruttore:&lt;/strong&gt;&lt;/em&gt; Minimizzazione dei costi di produzione &lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;Per il progettista:&lt;/em&gt;&lt;/strong&gt; Ottimizzazione del progetto&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/vantaggio-economico-dello-studio-dei.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4934697248348725017</guid><pubDate>Mon, 07 Sep 2009 19:42:00 +0000</pubDate><atom:updated>2010-05-09T16:33:40.354+02:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">ATP-EMTP</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><title>Software per lo studio di Transitori Elettrici</title><description>&lt;div align=&quot;justify&quot;&gt;Uno dei Software più utilizzati al mondo per lo studio e &lt;em&gt;l&#39;analisi dei Transitori&lt;/em&gt; nei sistemi elettrici è l&#39; &lt;strong&gt;&lt;em&gt;ATP-EMTP&lt;/em&gt;&lt;/strong&gt;, questo programma permette lo studio di Transitori di origine sia elettrica che elettromeccanica. &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Reti complesse, apparecchiatura elettrica e sistemi di controllo di qualsisi tipo possono essere modellati e studiati. Tra le applicazioni tipiche ricordiamo:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Sovratensioni atmosferiche ( Fulminazioni )&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Transitori di manovra ( Switching )&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Studi statistici di sovratensioni nelle reti&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;VFT in apparecchiatura GIS ( SF6 )&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Stabilità transitoria&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Oscillazioni torsionali&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Ferrorisonanza&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Elettronica di Potenza&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Archi elettrici&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Chopping di corrente&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Analisi armonica&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Test di sistemi di protezione&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;... e molto altro....&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;div align=&quot;justify&quot;&gt;Finora ho utilizzato ATP-EMTP per simulare :&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Protezione di sottostazioni dalle Sovratensioni atmosferiche&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Sistemi elettrici Ferroviari a 3 kV cc&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Arco di ritorno&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Interferenze elettromagnetiche tra linee aeree parallele &lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Simulazione di guasti in impianti complessi&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;Con ATP-EMTP è possibile studiare con successo condizioni di esercizio molto particolari, quindi: &lt;em&gt;&lt;strong&gt;questo tipo di approccio permette una ottimizzazione del progetto di un qualsiasi tipo di sistema elettrico, minimizzando i costi di costruzione e di esercizio, migliorandone l&#39;affidabilità.&lt;/strong&gt;&lt;/em&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;a href=&quot;http://www.emtp.org/&quot;&gt;&lt;strong&gt;&lt;em&gt;http://www.emtp.org/&lt;/em&gt;&lt;/strong&gt;&lt;/a&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/software-per-lo-studio-di-transitori.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>1</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-6261285487196813454</guid><pubDate>Sun, 06 Sep 2009 14:16:00 +0000</pubDate><atom:updated>2010-05-09T16:33:07.072+02:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">Transitorio elettrico</category><title>Transitorio elettrico</title><description>&lt;div align=&quot;justify&quot;&gt;Il &lt;strong&gt;&lt;em&gt;Transitorio elettrico&lt;/em&gt;&lt;/strong&gt; è rappresentato da una variazione temporanea di Tensione e/o Corrente di un circuito elettrico che ha subito un disturbo. La durata dei transitori elettrici è dell&#39;ordine di [ms] oppure [micro s], essi si manifestano su ongni tipo di impianto. &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Ogni impianto elettrico si trova a far fronte ai disturbi provenienti dalla rete di alimentazione, dai carchi, dall&#39; esercizio, ecc...&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Rimane quindi di fondamentale importanza lo studio dei Transitori elettrici. &lt;em&gt;Se effettuato in fase di progettazione, garantisce un risparmio economico non indifferente evitando disservizi, interruzioni della produzione e sostituzione componenti elettrici. &lt;/em&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align=&quot;justify&quot;&gt;I fenomeni di Transitorio elettrico possono essere provocati da:&lt;/div&gt;&lt;ul&gt;&lt;li&gt;Sovratensioni di manovra &lt;/li&gt;&lt;li&gt;Correnti nelle induttanze serie&lt;/li&gt;&lt;li&gt;Fulmnazioni&lt;/li&gt;&lt;li&gt;Guasti nell&#39;impianto&lt;/li&gt;&lt;li&gt;Elettricità statica&lt;/li&gt;&lt;li&gt;......&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;Lo studio dei transitori elettrici richiede la preparazione di &lt;em&gt;modelli matematici&lt;/em&gt; adeguati al tipo di applicazione in esame (Load Flow, Studio di correnti di guasto, Transitori di manovra, Fulminazioni). &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;Il modello matematico che verrà utilizzato poi per le simulazioni del Transitorio, deve essere scelto in base a delle considerazioni di tipo tecnico economico. Nella fase preparatoria del modello è di fondamentale importanza valutare:&lt;br /&gt;&lt;/p&gt;&lt;ul&gt;&lt;li&gt;Accuratezza&lt;/li&gt;&lt;li&gt;Mole di dati a disposizione&lt;/li&gt;&lt;li&gt;Facilità di intepretazione dei risultati&lt;/li&gt;&lt;li&gt;Tempi di realizzazione del modello&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;La preparazione del modello matematico di una rete elettrica, oppure di una parte di essa, richiede una particolare attenzione perchè vanno considerati solo i paramenteri che hanno una effettiva influenza sul fenomeno in esame. Un modello poco accurato porterebbe a risultati fuorvianti, e quindi ad uno spreco di risorse. &lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;br /&gt;&lt;br /&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/transitorio-elettrico.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-4133960577951407472</guid><pubDate>Thu, 03 Sep 2009 19:27:00 +0000</pubDate><atom:updated>2011-02-13T12:10:18.148+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Effetti Fisiopatologici della corrente sul corpo umano</title><description>&lt;div align=&quot;justify&quot;&gt;Perchè proteggere le persone dai possibili contatti con le parti in tensione di un impianto? La risposta risulta chiara se consideriamo quali sono gli effetti della corrente elettrica sul corpo umano:&lt;/div&gt;&lt;ol&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;Tetanizzazione dei muscoli:&lt;/em&gt;&lt;/strong&gt; contrazione involontaria dei muscoli, potrebbe non consentire un distaccamento del malcapitato dalla parte in tensione.&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;Difficoltà ed arresto della respirazione:&lt;/em&gt;&lt;/strong&gt; a causa della contrazione dei muscoli addetti alla respirazione.&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;Fibrillazione ventricolare:&lt;/em&gt;&lt;/strong&gt; è uno stato di asincronismo completo delle fibre miocardiache venricolari, genera una contrazione scoordinata e caotica, che porta alla morte per arresto cardiaco. &lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;strong&gt;&lt;em&gt;Ustioni:&lt;/em&gt;&lt;/strong&gt; sono prodotte dal calore sviluppato dalla corrente che attraversa il corpo umano, l&#39;aumento di temperatura che ne consegue risulta direttamente proporzionale al quadrato della densità di corrente, alla resistività del tessuto interessato ed alla durata della corente. Il contatto con circuiti di alta tensione produce la distruzione dei tessuti, dei centri nervosi e la rottura delle arterie.&lt;/div&gt;&lt;/li&gt;&lt;/ol&gt;&lt;p align=&quot;justify&quot;&gt;Per ovviare a questi problemi, sono state stabilite delle curve di pericolosità limite, definite &lt;em&gt;Curve di Sicurezza,&lt;/em&gt; che stabiliscono i valori limiti di corrente ammissibile per il corpo umano nelle diverse condizioni ambientali. Di queste curve si tiene conto nella fase progettazione dell&#39;impianto al fine di renderlo sicuro per le persone.&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/effetti-fisiopatologici-della-corrente.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-8292131913162436500</guid><pubDate>Thu, 03 Sep 2009 16:24:00 +0000</pubDate><atom:updated>2010-05-09T16:32:45.561+02:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><title>Sicureza elettrica e condizioni ambientali</title><description>&lt;div align=&quot;justify&quot;&gt;Il tema della sicurezza negli impianti elettrici, è di vitale importanza, poichè il guasto in un impianto eletrico può causare notevoli danni, compresa la perdita di vite umane.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt; &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Durante una manutenzione di un impianto industriale lessi un cartello monitore molto chiaro, che recitava:&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt; &lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;em&gt;&lt;strong&gt;&quot; La corrente non si vede, quando si sente è troppo tardi &quot;&lt;/strong&gt;&lt;/em&gt;&lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;/em&gt;&lt;/strong&gt; &lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;/em&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;div align=&quot;center&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Per fare in modo che l&#39;impianto sia idoneo alla sua funzione e non costituisca fonte di pericolo, ocorre valutare le caratteristiche dell&#39;ambiente d&#39;installazione e le attività a cui il luogo è destinato.&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;Esistono vari ambienti a rischio elettrico elevato, e sono:&lt;/div&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;&lt;ul&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;Ambienti a maggior rischio in caso di incendio&lt;/em&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;Luoghi con pericolo di esplosione&lt;/em&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;Locali ad uso medico&lt;/em&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;Cantieri&lt;/em&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;Luoghi conduttori ristretti&lt;/em&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;Piscine e Fontane&lt;/em&gt;&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;&lt;em&gt;.....&lt;/em&gt;&lt;/div&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p align=&quot;justify&quot;&gt;Occorre quindi effettuare una classificazione attenta del tipo di luogo ove verrà installato l&#39;impianto, in modo tale da poter realizzare una progettazione che tenga conto delle normative adeguate al tipo di ambiente, per massimizzare la sicurezza dell&#39;impianto, della produzione industriale e delle persone.&lt;/p&gt;&lt;div align=&quot;justify&quot;&gt;&lt;/div&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/sicureza-eletrica-e-condizioni.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-7558739020309204433.post-8353389380390194673</guid><pubDate>Tue, 01 Sep 2009 19:34:00 +0000</pubDate><atom:updated>2011-02-13T12:10:30.953+01:00</atom:updated><category domain="http://www.blogger.com/atom/ns#">certificazione energetica</category><category domain="http://www.blogger.com/atom/ns#">consulente energia</category><category domain="http://www.blogger.com/atom/ns#">consulente impianti</category><category domain="http://www.blogger.com/atom/ns#">energia</category><category domain="http://www.blogger.com/atom/ns#">fonti rinnovabili</category><category domain="http://www.blogger.com/atom/ns#">giuseppe lucci</category><category domain="http://www.blogger.com/atom/ns#">impianti energia</category><category domain="http://www.blogger.com/atom/ns#">progettazione impianti elettrici</category><category domain="http://www.blogger.com/atom/ns#">risparmio</category><title>Legge .... e regola d&#39;arte .....</title><description>&lt;div align=&quot;justify&quot;&gt;Fondamentale per tutti gli impianti elettrici è la &lt;strong&gt;&lt;em&gt;legge 186/1968.&lt;/em&gt;&lt;/strong&gt; Essa si compone di due soli articoli: &lt;/div&gt;&lt;ol&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;Tutti i materiali, le apparecchiature, i macchinari, le installazioni e gli impianti elettrici ed elettronici devono essere realizzati e costruiti a &lt;strong&gt;regola d&#39;arte&lt;/strong&gt;.&lt;/div&gt;&lt;/li&gt;&lt;li&gt;&lt;div align=&quot;justify&quot;&gt;I materiali, le apparecchiature, i macchinari, le installazioni e gli impianti elettrici ed elettronici realizzati secondo le norme del &lt;strong&gt;Comitato Elettrotecnico Italiano (CEI)&lt;/strong&gt; si considerano costruiti a regola d&#39;arte.&lt;/div&gt;&lt;/li&gt;&lt;/ol&gt;&lt;p align=&quot;justify&quot;&gt;E&#39; importante sottolinare il fatto che la legge 186/1968 &lt;em&gt;non esclude che impianti non eseguiti a norma CEI, ma progettati e realizzati secondo altri criteri (o standard), possano considerarsi a regola d&#39;arte&lt;/em&gt;. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;La differenza sta nel fatto che applicando le norme CEI, l&#39;impianto o l&#39;apperecchiatura sono già considerati a regola d&#39;arte, senza bisogno di ulteriori accertamenti. &lt;/p&gt;&lt;p align=&quot;justify&quot;&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;</description><link>http://impiantisticaelettrica.blogspot.com/2009/09/legge-e-regola-darte.html</link><author>noreply@blogger.com (Unknown)</author><thr:total>0</thr:total></item></channel></rss>