<?xml version="1.0" encoding="UTF-8" standalone="no"?><rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:blogger="http://schemas.google.com/blogger/2008" xmlns:gd="http://schemas.google.com/g/2005" xmlns:georss="http://www.georss.org/georss" xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd" xmlns:openSearch="http://a9.com/-/spec/opensearchrss/1.0/" xmlns:thr="http://purl.org/syndication/thread/1.0" version="2.0"><channel><atom:id>tag:blogger.com,1999:blog-8798529497783667034</atom:id><lastBuildDate>Fri, 30 Aug 2024 16:58:47 +0000</lastBuildDate><title>ITED</title><description>O essencial sobre ITED</description><link>http://electricidade-ited.blogspot.com/</link><managingEditor>noreply@blogger.com (Unknown)</managingEditor><generator>Blogger</generator><openSearch:totalResults>21</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><language>en-us</language><itunes:explicit>no</itunes:explicit><itunes:subtitle>O essencial sobre ITED</itunes:subtitle><itunes:owner><itunes:email>noreply@blogger.com</itunes:email></itunes:owner><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-6032154177322619700</guid><pubDate>Thu, 25 Oct 2007 11:33:00 +0000</pubDate><atom:updated>2008-01-10T18:54:31.334+00:00</atom:updated><title/><description>&lt;div align="center"&gt;&lt;a href="http://www.icp.pt/streaming/Manual_ITED_1Julho2004_2.pdf?categoryId=114719&amp;contentId=199931&amp;field=ATTACHED_FILE"&gt;Manual_ITED_1Julho2004_2 pdf&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgyXO9LBG8OwdyajKjwl05JIXHFElNU494M7FUFHkDw6T3j8AGwmJasjYD9Tyh1enoZPrbYEBRB9856-85rqm5UyXCSikcKEQJZHaVTEesTcsXqvJYYXSN2uKT9K956X4TaNz4tOmxjaW3N/s1600-h/Manual_ITED_1Julho2004_2.JPG"&gt;&lt;/a&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/manualited1julho20042-pdf_25.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-6016627998821552892</guid><pubDate>Thu, 18 Oct 2007 20:09:00 +0000</pubDate><atom:updated>2007-10-20T21:49:25.886+01:00</atom:updated><title>Alterações ao projecto - ITED</title><description>&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;Alterações ao projecto - ITED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;p&gt;&lt;br /&gt;O instalador ou entidade certificadora poderão constatar ser inevitável um desvio em relação ao &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt; nomeadamente nos seguintes momentos:&lt;br /&gt;. Instalação . Testes . Certificação&lt;br /&gt;O referido desvio deverá ser concretizado através de uma alteração ao projecto, devendo para tal cumprir-se as seguintes condições: - as alterações ao projecto são da autoria de um &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projectista de ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;- as alterações deverão estar de acordo com o estipulado no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;Manual de ITED&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;Nas alterações a um projecto já existente, dever-se-ão utilizar critérios de representação que as identifiquem claramente. Embora o &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projectista&lt;/span&gt; &lt;/strong&gt;seja livre de utilizar os critérios, que entenda como mais adequados, recomenda-se a utilização da seguinte nomenclatura:&lt;br /&gt;- a instalar, a traço fino e/ou cor vermelha&lt;br /&gt;- a retirar, a traço fino e cruzes (x x x) e/ou cor amarela - a manter, traço e cores originais &lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/alteraes-ao-projecto-ited.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-4116910965353787231</guid><pubDate>Sat, 13 Oct 2007 10:03:00 +0000</pubDate><atom:updated>2007-10-20T21:47:08.655+01:00</atom:updated><title>Obrigações do Projectista - ITED</title><description>&lt;div align="center"&gt;&lt;strong&gt;&lt;br /&gt;&lt;span style="font-size:180%;"&gt;Obrigações do Projectista - ITED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="left"&gt;&lt;br /&gt;&lt;strong&gt;•Prestar esclarecimentos:&lt;/strong&gt;&lt;br /&gt;- ao dono de obra&lt;br /&gt;- ao instalador&lt;br /&gt;- à entidade certificadora&lt;br /&gt;. Prestar assistência (selecção de materiais)&lt;br /&gt;- ao dono de obra&lt;br /&gt;- ao instalador&lt;br /&gt;&lt;br /&gt;•Assegurar, por si ou seu mandatário o acompanhamento da obra&lt;br /&gt;•Colaborar nas acções realizadas pelas entidades responsáveis por vistorias e fiscalizações&lt;br /&gt;•Contribuir para a melhoria das características técnicas das infraestruturas (estado de arte)&lt;br /&gt;•Disponibilizar o projecto ao dono de obra, ao condomínio, ao instalador e à entidade certificadora &lt;/div&gt;&lt;div align="left"&gt;•Enviar à &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ANACOM&lt;/span&gt;&lt;/strong&gt; os termos de responsabilidade &lt;/div&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/obrigaes-do-projectista.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-3742622732650412574</guid><pubDate>Tue, 09 Oct 2007 18:24:00 +0000</pubDate><atom:updated>2007-10-20T21:46:34.399+01:00</atom:updated><title>FIBRAS ÓPTICAS - ITED</title><description>&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;FIBRAS ÓPTICAS - ITED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119405467956217890" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjQ18sTB-ygjJXeA5fp88iKC1sEPL83vrciTzIZS_vAp7JXmGx0fdTx59J5dL3GL7naMo7R6exGGpkS5UaiPocCgHljxyRK0z3uTfk5vvo-yiSnUKlFsXrz7YjUHdvVH-Cc50qIoQFBcpxF/s320/FIBRA+OPTICA.JPG" border="0" /&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119405906042882098" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi7mZOsSquI7ytwjUzwQl5LxsHQf2i4yKsewbvkuWYgd7vMoG5q2EbbH7r3imgzQdwLTGThzt-MhtHGyTtZ42n69G1ecyNRlD-MNvgCMcGPOdy7XcQ6xMkXfCg0H0egivrH0wD2pOphTL7y/s320/FIBRA+OPTICA+TABELAS.JPG" border="0" /&gt;&lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/fibras-pticas.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjQ18sTB-ygjJXeA5fp88iKC1sEPL83vrciTzIZS_vAp7JXmGx0fdTx59J5dL3GL7naMo7R6exGGpkS5UaiPocCgHljxyRK0z3uTfk5vvo-yiSnUKlFsXrz7YjUHdvVH-Cc50qIoQFBcpxF/s72-c/FIBRA+OPTICA.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-1773698515567126456</guid><pubDate>Tue, 09 Oct 2007 18:13:00 +0000</pubDate><atom:updated>2007-10-20T21:46:08.445+01:00</atom:updated><title>CABOS COAXIAIS -ITED</title><description>&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;CABOS COAXIAIS - ITED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119402646162704386" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhiSujLyeqXrHBnxCz6FlTrw0HS52xz5yZhDzj1tSUtoCaslHSobcQT1RvlhVjIWNudjAA4x2xb3bzRKlnqDJiwmvLvPEfkWWgYKtLoyg8PzXdO18_iJbZuYxlPTKie0id_rw07l2w8t_EJ/s320/COAXIAL.JPG" border="0" /&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;1. Revestimento exterior&lt;br /&gt;2. Malha de blindagem&lt;br /&gt;3. Fita de blindagem&lt;br /&gt;4. Dieléctrico&lt;br /&gt;5. Condutor central&lt;br /&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;br /&gt;&lt;p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119403127199041554" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjhoQK2a5GmcexQl3kq9MGrssQor_y9w9OyK9znp3gn9BpjD5v0y4CwuH0ns9yEIniKpUsbE9oPATBw6TRrPGaFIr44NYWS3bUwbxmBZlbhAPqCbxKAduLry57KpJP2k-BLsFuDy7wh-L2A/s320/COAXIAL+TABELA.JPG" border="0" /&gt;&lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/cabos-coaxiais-ited.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhiSujLyeqXrHBnxCz6FlTrw0HS52xz5yZhDzj1tSUtoCaslHSobcQT1RvlhVjIWNudjAA4x2xb3bzRKlnqDJiwmvLvPEfkWWgYKtLoyg8PzXdO18_iJbZuYxlPTKie0id_rw07l2w8t_EJ/s72-c/COAXIAL.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-3888922474911108320</guid><pubDate>Tue, 09 Oct 2007 17:59:00 +0000</pubDate><atom:updated>2007-10-20T21:45:26.688+01:00</atom:updated><title>PARES DE COBRE - ITED</title><description>&lt;div align="center"&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;Pares de cobre - ITED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p align="left"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119399772829583330" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiLos-CT7r6Tv6Xt0AuNxL5ou4zo3C74Q9irhpuTgHT8oUFeT3HJBsd5ouO0PlCyZ2T5aftaaPGkAb5bgWpiaT9v4CspPOZv6-xThUahPvEEwsnhI8vdJiiPeBxI9hY5xiMppye4bduMMOP/s320/utp.JPG" border="0" /&gt;&lt;/p&gt;&lt;br /&gt;Os &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabos UTP&lt;/span&gt;&lt;/strong&gt; são divididos em 5 categorias, levando em conta o nível de segurança e a espessura do fio, onde os números maiores indicam fios com diâmetros menores, veja em abaixo um resumo simplificado dos cabos &lt;strong&gt;&lt;span style="font-size:180%;"&gt;UTP.&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;Categoria 1 Voz (Cabo Telefónico)&lt;br /&gt;&lt;br /&gt;Categoria 2 Dados a 4 Mbps (LocalTalk)&lt;br /&gt;&lt;br /&gt;Categoria 3 Transmissão de até 16 MHz. Dados a 10 Mbps (Ethernet)&lt;br /&gt;&lt;br /&gt;Categoria 4 Transmissão de até 20 MHz. Dados a 20 Mbps (16 Mbps Token Ring)&lt;br /&gt;&lt;br /&gt;Categoria 5 Transmissão de até 100 MHz. Dados a 100 Mbps (Fast Ethernet)&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img id="BLOGGER_PHOTO_ID_5119401336197679090" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiklb_LxxThgjZpiHd5pfJ7o9QYDF4Qaf35KpNwouuh37xM8pwvnd9BKeBoQE57K99efK1L-stAC8_6oX1o-Utyo5qYp56KsU7wMxhTcO-Bnsxved_20LHNaqfbnylTABroCvy1C9-HIpzk/s320/Stp.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;Há cabos normalizados com capacidade de 4, 8, 12, 16, 20, 32, 40, 60, 100, 200 e 300 pares de cobre.&lt;/p&gt;&lt;p&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabo UTP&lt;/span&gt;&lt;/strong&gt; categoria 5e tambem pode ser utilizado para redes informaticas até 100Mbps. &lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/pares-de-cobre.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiLos-CT7r6Tv6Xt0AuNxL5ou4zo3C74Q9irhpuTgHT8oUFeT3HJBsd5ouO0PlCyZ2T5aftaaPGkAb5bgWpiaT9v4CspPOZv6-xThUahPvEEwsnhI8vdJiiPeBxI9hY5xiMppye4bduMMOP/s72-c/utp.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-1454902883754163200</guid><pubDate>Tue, 09 Oct 2007 17:54:00 +0000</pubDate><atom:updated>2007-10-29T13:57:35.697+00:00</atom:updated><title>Repartidor Geral</title><description>&lt;a name="RG"&gt;&lt;/a&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG (Repartidor Geral)&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;Repartidor Geral de Par de Cobre (RG-PC):&lt;/span&gt;&lt;/strong&gt; dispositivo que faz a interligação dos cabos de pares de cobre dos diversos operadores, à rede de cabos de pares de cobre do edifício.&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC&lt;/span&gt;&lt;/strong&gt; é basicamente constituído por dispositivos de ligação e distribuição, sendo o elemento base a unidade modular, como por exemplo do tipo &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDS&lt;/span&gt;&lt;/strong&gt; (Dispositivo de Distribuição Simples) ou &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDE&lt;/span&gt;&lt;/strong&gt; (Dispositivo de Distribuição de Corte e Ensaio).&lt;br /&gt;O &lt;span style="font-size:180%;"&gt;&lt;strong&gt;RG-PC&lt;/strong&gt;&lt;/span&gt; é composto por:&lt;br /&gt;- Primário, onde se vão ligar os cabos de entrada dos vários operadores, constituídos por &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDS&lt;/span&gt;&lt;/strong&gt; ou&lt;strong&gt;&lt;span style="font-size:180%;"&gt; DDE&lt;/span&gt;&lt;/strong&gt;;&lt;br /&gt;- Secundário, onde se liga a rede do edifício, constituído por &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDE.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;Os primários localizam-se normalmente do lado esquerdo do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC&lt;/span&gt;&lt;/strong&gt;. Quando for necessária a utilização de órgãos de protecção (descarregadores de sobretensão), estes são colocados nas unidades modulares que constituem os primários.&lt;br /&gt;Secundário&lt;br /&gt;Primário&lt;br /&gt;As unidades modulares do secundário localizam-se normalmente do lado direito, ou na retaguarda, do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC.&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img id="BLOGGER_PHOTO_ID_5119397509381818322" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiAoCxLufKOp2cicG-gaR69SBijL6S-ZJ8cTQrs8-ExJlLwGAM4Z-8T1FFmv3WZShaDg88-6TU1O9PjJdpdK8EV7EIWo7QL2Ls8pEfmgey39yoFnjF2A3zctXZ20eD4_kUFJrEqr2VJU0wa/s320/DC.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;Repartidor Geral de Par de Cobre+ (RG-PC+&lt;/span&gt;):&lt;/strong&gt; dispositivo que faz a interligação da rede de acesso dos diversos operadores (em par de cobre, cabo coaxial ou fibra óptica), à rede de cabos de pares de cobre do edifício.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;Repartidor Geral de Cabo Coaxial (RG-CC):&lt;/span&gt;&lt;/strong&gt; dispositivo que faz a interligação dos cabos coaxiais dos diversos operadores, à rede de distribuição em cabo coaxial do edifício.&lt;br /&gt;&lt;strong&gt;&lt;br /&gt;&lt;span style="font-size:180%;"&gt;Repartidor Geral de Fibra Óptica (RG-FO):&lt;/span&gt;&lt;/strong&gt; dispositivo que faz a interligação dos cabos de fibra óptica dos diversos operadores, à rede de cabos de fibra óptica do edifício.&lt;/p&gt;&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG Repartidor Geral de Par de Cobre (RG-PC):&lt;/span&gt;&lt;/strong&gt; dispositivo que faz a interligação dos cabos de pares de cobre dos diversos operadores, à rede de cabos de pares de cobre do edifício. O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC&lt;/span&gt;&lt;/strong&gt; é basicamente constituído por dispositivos de ligação e distribuição, sendo o elemento base a unidade modular, como por exemplo do tipo &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDS &lt;/span&gt;&lt;/strong&gt;(Dispositivo de Distribuição Simples) ou &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDE&lt;/span&gt;&lt;/strong&gt; (Dispositivo de Distribuição de Corte e Ensaio). O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC&lt;/span&gt;&lt;/strong&gt; é composto por: - Primário, onde se vão ligar os cabos de entrada dos vários operadores, constituídos por &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDS&lt;/span&gt;&lt;/strong&gt; ou &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDE&lt;/span&gt;&lt;/strong&gt;; - Secundário, onde se liga a rede do edifício, constituído por &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDE.&lt;/span&gt;&lt;/strong&gt; Os primários localizam-se normalmente do lado esquerdo do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC.&lt;/span&gt;&lt;/strong&gt; Quando for necessária a utilização de órgãos de protecção (descarregadores de sobretensão), estes são colocados nas unidades modulares que constituem os primários. &lt;/p&gt;&lt;p&gt;As unidades modulares do secundário localizam-se normalmente do lado direito, ou na retaguarda, do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC. &lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/rg.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiAoCxLufKOp2cicG-gaR69SBijL6S-ZJ8cTQrs8-ExJlLwGAM4Z-8T1FFmv3WZShaDg88-6TU1O9PjJdpdK8EV7EIWo7QL2Ls8pEfmgey39yoFnjF2A3zctXZ20eD4_kUFJrEqr2VJU0wa/s72-c/DC.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-6940467365907241202</guid><pubDate>Tue, 09 Oct 2007 17:43:00 +0000</pubDate><atom:updated>2007-10-20T21:39:57.786+01:00</atom:updated><title>CEMU</title><description>&lt;strong&gt;&lt;span style="font-size:180%;"&gt;CEMU (Caixa de Entrada de Moradia Unifamiliar)&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;A &lt;span style="font-size:180%;"&gt;CEMU&lt;/span&gt; é uma caixa utilizada nas moradias unifamiliares, destinada ao alojamento de dispositivos de derivação ou transição. Esta caixa faz a transição entre as redes públicas de telecomunicações e a rede individual de cabos. &lt;img id="BLOGGER_PHOTO_ID_5119395331833399234" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirjUGWfAJisefaxwxNpRwvMAnUY1Z54AooktVkVn4eRivN-asHi87dfAz4TXauWWS3GpzYUGJtDskFceaH8zcZ6gmmHEWWUyvDbNMN5ZKk-tDFKzOY6jZmyYLyx-OXLWDx8y8Ejxr0yPxc/s320/CEMU.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Como mínimo entende-se que contenha o seguinte:&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;• 1 Dispositivo de ligação e distribuição com capacidade para ligação de 4 pares de cobre. A este bloco é ligado, para jusante, o cabo de pares de cobre que se dirige ao &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;. Para montante são ligados os cabos de operador.&lt;br /&gt;&lt;br /&gt;• Ficha na parte terminal do cabo coaxial proveniente da rede individual, que permita uma ligação conveniente dos cabos de operador.</description><link>http://electricidade-ited.blogspot.com/2007/10/cemu.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirjUGWfAJisefaxwxNpRwvMAnUY1Z54AooktVkVn4eRivN-asHi87dfAz4TXauWWS3GpzYUGJtDskFceaH8zcZ6gmmHEWWUyvDbNMN5ZKk-tDFKzOY6jZmyYLyx-OXLWDx8y8Ejxr0yPxc/s72-c/CEMU.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-2249331210761600510</guid><pubDate>Tue, 09 Oct 2007 17:41:00 +0000</pubDate><atom:updated>2007-10-20T21:38:58.258+01:00</atom:updated><title>ATE</title><description>&lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE (Armário de Telecomunicações do Edifício)&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;Os Armários de Telecomunicações do Edifício &lt;strong&gt;&lt;span style="font-size:180%;"&gt;(ATE)&lt;/span&gt;&lt;/strong&gt; fazem parte da rede colectiva de tubagens e vão alojar os vários Repartidores Gerais (&lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG&lt;/span&gt;&lt;/strong&gt;) que possam existir.&lt;br /&gt;O&lt;strong&gt;&lt;span style="font-size:180%;"&gt; ATE&lt;/span&gt;&lt;/strong&gt; é o ponto de confluência das redes dos operadores, sejam elas em par de cobre, em cabo coaxial ou em fibra óptica.&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE &lt;/span&gt;&lt;/strong&gt;contém obrigatoriamente um barramento de terras, onde se vão ligar as terras de protecção das &lt;strong&gt;ITED&lt;/strong&gt;. Este barramento (barramento geral de terras das &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED - BGT&lt;/span&gt;&lt;/strong&gt;) é por sua vez interligado ao barramento geral de terras do edifício.&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; deve disponibilizar espaço suficiente para o acesso de, no mínimo, 4 redes de operadores de telecomunicações.&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; deve disponibilizar circuitos de energia 230 V AC, para fazer face às necessidades de alimentação eléctrica. Serão disponibilizados, no mínimo, 4 tomadas com terra.&lt;br /&gt;&lt;br /&gt;O&lt;strong&gt;&lt;span style="font-size:180%;"&gt; ATE&lt;/span&gt;&lt;/strong&gt; inferior, localizado no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ETI&lt;/span&gt;&lt;/strong&gt; (Espaço de Telecomunicações Inferior), contém pelo menos dois repartidores gerais: o &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-PC&lt;/span&gt;&lt;/strong&gt; (par de cobre) e o RG-CC (cabo coaxial).&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; superior, localizado no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ETS&lt;/span&gt;&lt;/strong&gt; (Espaço de Telecomunicações Superior), contém pelo menos o &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG-CC&lt;/span&gt;&lt;/strong&gt; (cabo coaxial), para a rede de cablagem de recepção e distribuição de sinais de radiodifusão sonora e televisiva, no caso de edifícios de quatro ou mais fracções autónomas.</description><link>http://electricidade-ited.blogspot.com/2007/10/ate.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-1684863384711144804</guid><pubDate>Tue, 09 Oct 2007 16:49:00 +0000</pubDate><atom:updated>2007-10-20T21:35:20.774+01:00</atom:updated><title>ATI</title><description>&lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI (Armário de Telecomunicações Individual)&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;No diagrama seguinte apresenta-se uma solução de &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, com ligação a 2 redes de cabo coaxial e a 1 rede de cabos de pares de cobre.&lt;br /&gt;Estão incluídos um barramento de terras e 1 tomada 230V AC.&lt;br /&gt;As tomadas mistas de 1 a 4 estão ligadas à rede de CATV (Community Antenna Television) e a um operador em par de cobre. As tomadas 5 e 6 recebem sinal de um sistema de MATV (Master Antenna Television) e de um segundo operador em par de cobre.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img id="BLOGGER_PHOTO_ID_5119381261520537490" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg6ot5f14AIq2eQgMnSxq8_zkhqM2fiVwX_bwqxGVVmQZWy1HgXTexIF7-UNxrb3MuToS3CtIwMZA1Nbe8KQeln0Fa7XVBmFHUu3SOzTOxdxSRzsfZyG9SqFxm22TAkCJH3rlLWnTz6-ljW/s320/ATI.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;TC – Tap de Cliente (Terminal de Acesso de Cliente)&lt;/span&gt;&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;Apresenta-se de seguida o esquema de constituição de um possível TC e respectivas interligações, integrados num&lt;strong&gt; &lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;.&lt;br /&gt;Na figura seguinte representam-se 2 TC. Existem 6 tomadas de cliente e foram instalados TC de 8 saídas. Um dos repartidores está ligado à rede coaxial de CATV (Community Antenna Television) e o outro à rede coaxial de MATV (Master Antenna Television).&lt;br /&gt;As tomadas de cliente, embora possam ser directamente ligadas aos repartidores, estão neste caso terminadas num painel de fichas “F” – fêmea. Esta solução introduz, no entanto, maiores atenuações.&lt;br /&gt;Na figura seguinte representa-se a interligação entre as redes coaxiais e as tomadas de cliente.&lt;br /&gt;A interligação referida é feita à custa de chicotes de interligação “F”-macho, disponibilizados no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;. As 4 primeiras tomadas recebem o sinal proveniente da rede de CATV enquanto que as tomadas 5 e 6 estão ligadas à rede de MATV.As saídas não usadas estão carregadas com cargas simples de 75 Ohm.&lt;/p&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119387970259453858" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiUR5XYq_8g7LfuVpfFbnQHhzEOVxK58WswiQgdP5NflcobvUJIG8tCTBrksTx5B22Lchd8VV-I23Ot5sa54ipxOXxs_R7yNDn8dxhbpA1PU-TqCLzvAs9OQO8MEnj_vNUo-E0QRgNknqx4/s320/ATI+1.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;p&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC (Dispositivo de Derivação de Cliente)&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Apresenta-se de seguida o esquema de constituição de um possível &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC&lt;/span&gt;&lt;/strong&gt;, integrado num &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;. Na figura estão representadas, a tracejado (----), as ligações realizadas na parte traseira das tomadas de 8 contactos.&lt;br /&gt;A figura seguinte permite que dois operadores cheguem à fracção autónoma, em que um utiliza o PAR 1 e outro o PAR 3 e 4. As tomadas de cliente, por manobra dos chicotes de interligação no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC&lt;/span&gt;&lt;/strong&gt;, estão assim divididas pelos dois operadores: tomadas 1 e 2 para o 1º operador; tomadas 3, 4 e 5 para o 2º operador.&lt;br /&gt;As tomadas dentro do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC&lt;/span&gt;&lt;/strong&gt; (identificadas de 1 a 5 – secundário do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC&lt;/span&gt;&lt;/strong&gt;) estão ligadas em conjuntos de duas, em paralelo, permitindo (em conjugação com chicotes) a individualização do sinal que chega a cada uma das tomadas. Os chicotes de interligação são constituídos por duas fichas de 8 contactos (RJ45 por exemplo) interligadas por um cabo de 4 pares de cobre (UTP, por exemplo).&lt;br /&gt;Por último, cada um dos referidos conjuntos está ligado, em 4 pares de cobre, a cada uma das tomadas de cliente, também identificadas de 1 a 5.&lt;/p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119392965306419122" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgfPg78vPOOrbT-wVY-n9KI6udpXAd4kmBgRINMbs8hE3ZMAoajCUN2l2gQrW64MT2EsZBgDsygJXokZMEf6pQJ7Z8aXIstB4vgXM3360ZUjJTJIgxT9zZFIztlDf3zfEOMGTNN5cZV5Ahx/s320/ATI2.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/ati.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg6ot5f14AIq2eQgMnSxq8_zkhqM2fiVwX_bwqxGVVmQZWy1HgXTexIF7-UNxrb3MuToS3CtIwMZA1Nbe8KQeln0Fa7XVBmFHUu3SOzTOxdxSRzsfZyG9SqFxm22TAkCJH3rlLWnTz6-ljW/s72-c/ATI.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-4188849027152675996</guid><pubDate>Tue, 09 Oct 2007 16:43:00 +0000</pubDate><atom:updated>2007-10-20T21:32:20.619+01:00</atom:updated><title>REDES DE CABOS – REDE COLECTIVA - ITED</title><description>&lt;strong&gt;&lt;span style="font-size:180%;"&gt;REDES DE CABOS – REDE COLECTIVA - ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;· A rede em par de cobre é constituída por componentes de categoria 3 (frequência máxima 16 MHz / Nível de qualidade NQ1a), como mínimo.&lt;br /&gt;&lt;br /&gt;· &lt;strong&gt;&lt;span style="font-size:180%;"&gt;Cabos de pares de cobre:&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;- O somatório dos pares utilizados nas redes individuais deve ser multiplicado por 1,2 (+20%) e deve ser escolhido o cabo normalizado, com capacidade imediatamente superior ao valor calculado.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:180%;"&gt;&lt;strong&gt;Cabos coaxiais:&lt;/strong&gt;&lt;br /&gt;&lt;/span&gt;- Devem ser utilizados &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabos coaxiais&lt;/span&gt;&lt;/strong&gt; do tipo RG11,RG7 ou RG6, apropriados a frequências até 1Ghz.</description><link>http://electricidade-ited.blogspot.com/2007/10/redes-de-cabos-rede-colectiva-ited.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-1669849973277686719</guid><pubDate>Mon, 08 Oct 2007 20:31:00 +0000</pubDate><atom:updated>2007-10-20T21:30:20.631+01:00</atom:updated><title>REDES DE TUBAGENS – REDE COLECTIVA - ITED</title><description>&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;REDE de TUBAGENS– REDE COLECTIVA - ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;/div&gt;&lt;p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119066801194993522" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSPypyjk7uL0Aw9PtsXV9kqukxLNCOru9ktZ7pps5b2TC83zWcMV_pq7GX2IYCh2QfTIhC5-t2qOBMSvmqXn-JV1HTB1NRNBDd8uV0Tly6r7UtlYgKDzs4bJXmgcPJU0SSaYOAhyphenhyphenzrO5OK/s320/REDES+DE+TUBAGENS+%E2%80%93+REDE+COLECTIVA.JPG" border="0" /&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p align="left"&gt;Coluna montante para cabos de &lt;strong&gt;&lt;span style="font-size:180%;"&gt;pares de cobre&lt;/span&gt;&lt;/strong&gt; com 2 tubos = 40 mm, sendo um deles de reserva.&lt;br /&gt;&lt;br /&gt;Coluna montante para cabos cabos coaxiais e &lt;strong&gt;&lt;span style="font-size:180%;"&gt;fibras ópticas&lt;/span&gt;&lt;/strong&gt; com 2 tubos = 40 mm, sendo um deles de reserva.&lt;br /&gt;&lt;br /&gt;1 Tubo = 25 mm da coluna montante até cada &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI &lt;/span&gt;&lt;/strong&gt;(Armário de Telecomunicações Individual), para passagem dos cabos de pares de cobre.&lt;br /&gt;&lt;br /&gt;1 Tubo = 32 mm da coluna montante até cada &lt;span style="font-size:180%;"&gt;&lt;strong&gt;ATI&lt;/strong&gt;&lt;/span&gt;, para passagem dos cabos coaxiais e fibras ópticas.&lt;br /&gt;&lt;br /&gt;A &lt;strong&gt;&lt;span style="font-size:180%;"&gt;PAT&lt;/span&gt;&lt;/strong&gt; (Passagem Aérea de Topo) para ligação a antenas é realizada com 2 tubos com diâmetro = 40mm.&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; (Armário de Telecomunicações do Edifício) que contém o &lt;strong&gt;&lt;span style="font-size:180%;"&gt;RG &lt;/span&gt;&lt;/strong&gt;(Repartidor Geral) é interligado ao quadro de energia eléctrica (QE) por dois tubos de diâmetro ≥ 20 mm (um tubo para o circuito de tomadas do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; e o outro tubo para o condutor de terra).&lt;br /&gt;&lt;br /&gt;No cálculo da entrada subterrânea, ligada ao &lt;strong&gt;ATE&lt;/strong&gt;, deverá ser consultada a Tabela 15 do Manual &lt;strong&gt;ITED&lt;/strong&gt; da &lt;strong&gt;ANACOM&lt;/strong&gt;.&lt;br /&gt;&lt;br /&gt;No caso da existência de entradas aéreas ao nível do piso térreo, consideram-se 2 tubos com diâmetro = 25 mm।&lt;/p&gt;&lt;p align="left"&gt;&lt;br /&gt;&lt;/p&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;/div&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/redes-de-tubagens-rede-colectiva.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSPypyjk7uL0Aw9PtsXV9kqukxLNCOru9ktZ7pps5b2TC83zWcMV_pq7GX2IYCh2QfTIhC5-t2qOBMSvmqXn-JV1HTB1NRNBDd8uV0Tly6r7UtlYgKDzs4bJXmgcPJU0SSaYOAhyphenhyphenzrO5OK/s72-c/REDES+DE+TUBAGENS+%E2%80%93+REDE+COLECTIVA.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-6129881716953477230</guid><pubDate>Mon, 08 Oct 2007 20:27:00 +0000</pubDate><atom:updated>2007-10-20T21:27:40.620+01:00</atom:updated><title>REDES DE CABOS – REDE INDIVIDUAL - ITED</title><description>&lt;div align="left"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;REDES DE CABOS – REDE INDIVIDUAL - ITED&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;1 Dispositivo de ligação e distribuição para cabos de pares de cobre, de categoria 5 (frequência máxima 100 MHz/Nível de qualidade NQ1b) ou superior, instalado na &lt;strong&gt;&lt;span style="font-size:180%;"&gt;CEMU &lt;/span&gt;&lt;/strong&gt;(Caixa de Entrada da Moradia Unifamiliar). A partir deste dispositivo:&lt;br /&gt;- Um cabo de pares de cobre, de categoria 5 (frequência máxima 100 MHz/Nível de qualidade NQ1b) ou superior, até ao &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC&lt;/span&gt;&lt;/strong&gt; (Dispositivo de Derivação de Cliente).&lt;br /&gt;&lt;br /&gt;1 Dispositivo de ligação coaxial que termina cada cabo coaxial que se dirige ao TC (Tap de Cliente). O dispositivo está instalado na &lt;strong&gt;&lt;span style="font-size:180%;"&gt;CEMU&lt;/span&gt;&lt;/strong&gt;. A partir deste dispositivo:&lt;br /&gt;- Um cabo coaxial até ao TC.&lt;br /&gt;&lt;br /&gt;1 DDC, fazendo parte do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;. A partir do DDC:&lt;br /&gt;&lt;br /&gt;- Distribuição em estrela até às tomadas de cliente, com componentes de categoria 5 (frequência máxima 100 MHz/Nível de qualidade NQ1b);&lt;br /&gt;&lt;br /&gt;- Ligações suportadas em cabo de 4 pares de cobre (UTP, por exemplo);&lt;br /&gt;&lt;br /&gt;- Tomadas de 8 contactos (por exemplo RJ45): 1 tomada por quarto, 1 tomada por sala e 1 tomada na cozinha.&lt;br /&gt;&lt;br /&gt;1 TC, fazendo parte do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, por cada rede de cablagem coaxial instalada. A partir do TC:&lt;br /&gt;&lt;br /&gt;- Distribuição em estrela até às tomadas de cliente, em cabo coaxial RG59, RG6 ou RG7;&lt;br /&gt;&lt;br /&gt;- Tomadas coaxiais: 1 tomada por quarto, 1 tomada por sala e 1 tomada na cozinha. &lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119065564244412258" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEifC3n5EKxQ3c8l6jZw3AWeUcWKeUEkgIp5NEsQANMo8PEWXkb9yy3-XghbkdVvFL3_CVc9mKY3RUr7AQyYE1Wj-q7a78WLP-p8pBpxHHJ_rRNKvAp9_F3XdI76tGd-59rKDQ4zPBtivbXA/s320/REDES+DE+CABOS+%E2%80%93+REDE+INDIVIDUAL.JPG" border="0" /&gt; &lt;/p&gt;&lt;br /&gt;&lt;p&gt;· 1&lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC&lt;/span&gt;&lt;/strong&gt; (Dispositivo de Derivação de Cliente), fazendo parte do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; (Armário de Telecomunicações Individual). A partir do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;DDC&lt;/span&gt;&lt;/strong&gt;:&lt;br /&gt;&lt;br /&gt;- Distribuição em estrela até às tomadas de cliente, com componentes de categoria 5 (frequência máxima 100 MHz/Nível de qualidade NQ1b);&lt;br /&gt;- Ligações suportadas em cabo de 4 &lt;strong&gt;&lt;span style="font-size:180%;"&gt;pares de cobre&lt;/span&gt;&lt;/strong&gt; (&lt;strong&gt;&lt;span style="font-size:180%;"&gt;UTP,&lt;/span&gt;&lt;/strong&gt; por exemplo);&lt;br /&gt;- Tomadas de 8 contactos (por exemplo RJ45): 1 tomada por quarto, 1 tomada por sala e 1 tomada na cozinha.&lt;br /&gt;-1 tomada por posto de trabalho ou por cada 10m2 de área útil.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;· 1 TC (Tap de Cliente), fazendo parte do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, por cada rede de cablagem coaxial instalada. A partir do TC a distribuição é facultativa. No caso de ser concretizada:&lt;br /&gt;·&lt;br /&gt;&lt;br /&gt;- Distribuição em estrela até às tomadas de cliente, em &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabo coaxial&lt;/span&gt;&lt;/strong&gt; RG59, RG6 ou RG7;&lt;br /&gt;- Tomadas coaxiais: 1 tomada por quarto, 1 tomada por sala e 1 tomada na cozinha.&lt;br /&gt;- Tomadas coaxiais: 1 tomada por posto de trabalho ou por cada 10 m2.&lt;br /&gt;&lt;img id="BLOGGER_PHOTO_ID_5119374174824499074" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiIx7lKXVrLYB4DbxA-4yQMZuzQln_gYAosEMpO1_rWb1ytmDKvLq9UrhGw7rZ3ruAsaO9bgoSKUxqoxHLJ88-dUWo4yOyv7ae4vjUD6OxRJBn8CeZOFyxk19Bd5yRTqyeahhJthFQEj9sh/s320/REDES+DE+TUBAGENS+%E2%80%93+REDE+INDIVIDUAL2.JPG" border="0" /&gt;&lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/redes-de-cabos-rede-individual.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEifC3n5EKxQ3c8l6jZw3AWeUcWKeUEkgIp5NEsQANMo8PEWXkb9yy3-XghbkdVvFL3_CVc9mKY3RUr7AQyYE1Wj-q7a78WLP-p8pBpxHHJ_rRNKvAp9_F3XdI76tGd-59rKDQ4zPBtivbXA/s72-c/REDES+DE+CABOS+%E2%80%93+REDE+INDIVIDUAL.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-2466588791275109728</guid><pubDate>Mon, 08 Oct 2007 20:10:00 +0000</pubDate><atom:updated>2007-10-20T20:51:08.683+01:00</atom:updated><title>REDES DE TUBAGENS – REDE INDIVIDUAL - ITED</title><description>&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;br /&gt;REDES DE TUBAGENS – REDE INDIVIDUAL&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;1 Tubo ≥ 25 mm da &lt;strong&gt;&lt;span style="font-size:180%;"&gt;CEMU&lt;/span&gt;&lt;/strong&gt; (Caixa de Entrada da Moradia Unifamiliar) até ao &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; (Armário de Telecomunicações Individual), para passagem dos cabos de pares de cobre.&lt;br /&gt;&lt;br /&gt;1 Tubo ≥ 32 mm da &lt;strong&gt;&lt;span style="font-size:180%;"&gt;CEMU&lt;/span&gt;&lt;/strong&gt; até ao &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, para passagem dos cabos coaxiais e fibras ópticas.&lt;br /&gt;&lt;br /&gt;A entrada subterrânea, ligada à &lt;strong&gt;&lt;span style="font-size:180%;"&gt;CEMU&lt;/span&gt;&lt;/strong&gt;, é realizada com 2 tubos com diâmetros = 50 mm.&lt;br /&gt;&lt;br /&gt;A &lt;strong&gt;&lt;span style="font-size:180%;"&gt;PAT&lt;/span&gt;&lt;/strong&gt; (Passagem Aérea de Topo) para ligação a antenas é realizada com 2 tubos com diâmetro = 32 mm.&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; é interligado ao quadro de energia eléctrica (Q.E.) por dois tubos de diâmetro ≥ 20 mm (um tubo para o circuito de tomadas do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; e o outro tubo para o condutor de terra).&lt;br /&gt;&lt;br /&gt;O &lt;span style="font-size:180%;"&gt;&lt;strong&gt;ATI&lt;/strong&gt;&lt;/span&gt; é interligado por um tubo de diâmetro ≥ 20 mm a uma caixa (do tipo I1, por exemplo), para interligações futuras a equipamentos activos de cliente que não possam estar no interior do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; nomeadamente uma &lt;strong&gt;&lt;span style="font-size:180%;"&gt;WLAN&lt;/span&gt;&lt;/strong&gt; (Wireless Local Area Network).&lt;br /&gt;&lt;br /&gt;No caso da existência de entrada aérea ao nível do piso térreo, consideram-se 2 tubos com diâmetro = 25 mm.&lt;br /&gt;&lt;br /&gt;A tubagem é partilhada por todos os tipos de cabos de telecomunicações que sejam instalados.&lt;br /&gt;&lt;/div&gt;&lt;img id="BLOGGER_PHOTO_ID_5119064228509583186" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhlQ8BcGZrqCBN8bk4Qicqqaz577psMk7Aa26Jz2zhvPixyGFfk2cG2oM54zUBPeoKfCvLsL6AsJWw9Ch8LKV2SFrPBG2ndbPVi_QmIgCwcFYqIqtn_mOkROsGxekfO5cuqZTGLIMUpGJTb/s320/REDES+DE+TUBAGENS+%E2%80%93+REDE+INDIVIDUAL.JPG" border="0" /&gt; &lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; (Armário de Telecomunicações Individual) é interligado à coluna montante e ao quadro de energia eléctrica (Q.E.) sendo a este último ligado por dois tubos de diâmetro ≥ 20 mm (um tubo para o circuito de tomadas do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; e o outro tubo para o condutor de terra).&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; é interligado por um tubo de diâmetro ≥ 20 mm a uma caixa (do tipo I1, por exemplo), para interligações futuras a equipamentos activos de cliente que não possam estar no interior do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; nomeadamente uma &lt;strong&gt;&lt;span style="font-size:180%;"&gt;WLAN&lt;/span&gt;&lt;/strong&gt; (Wireless Local Area Network).&lt;br /&gt;&lt;br /&gt;A tubagem é partilhada por todos os tipos de cabos de telecomunicações que sejam instalados.&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/redes-de-tubagens-rede-individual.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhlQ8BcGZrqCBN8bk4Qicqqaz577psMk7Aa26Jz2zhvPixyGFfk2cG2oM54zUBPeoKfCvLsL6AsJWw9Ch8LKV2SFrPBG2ndbPVi_QmIgCwcFYqIqtn_mOkROsGxekfO5cuqZTGLIMUpGJTb/s72-c/REDES+DE+TUBAGENS+%E2%80%93+REDE+INDIVIDUAL.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-2930772462564787328</guid><pubDate>Mon, 08 Oct 2007 19:16:00 +0000</pubDate><atom:updated>2007-10-20T20:47:12.630+01:00</atom:updated><title>FICHAS TÉCNICAS - ITED</title><description>&lt;strong&gt;&lt;span style="font-size:180%;"&gt;FICHAS TÉCNICAS - ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjsKO-rEzMvMjxb2esxowyZ8abaFw_upbASIHViOSO2rmgVtkQOIzzdXdmxTR6NkRiB-cl3zeQ9B67yTwT6gvexCOAVuuWCEYUIbP8i2gXpwbRD0JgcG3duDVCzNcsdFd6hWcpohDf3NQKJ/s1600-h/Fichas+Tecnicas+-+ITED.JPG"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119059280707258178" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjsKO-rEzMvMjxb2esxowyZ8abaFw_upbASIHViOSO2rmgVtkQOIzzdXdmxTR6NkRiB-cl3zeQ9B67yTwT6gvexCOAVuuWCEYUIbP8i2gXpwbRD0JgcG3duDVCzNcsdFd6hWcpohDf3NQKJ/s320/Fichas+Tecnicas+-+ITED.JPG" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjvdYsstuApAljuGiLfnPNQyhs4wR0GzOf-V-FiJAEqKJ9Vr5kl__uaojHMWCeizxN2neUOOBGmntCsrhBN3l5ukwttXcPnQFs0Otp8KfWomtVxOjjbZpBdNTrJveQmZ27AvjaLfIWytioe/s1600-h/Fichas+Tecnicas+-+ITED.bmp"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119055307862509362" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjvdYsstuApAljuGiLfnPNQyhs4wR0GzOf-V-FiJAEqKJ9Vr5kl__uaojHMWCeizxN2neUOOBGmntCsrhBN3l5ukwttXcPnQFs0Otp8KfWomtVxOjjbZpBdNTrJveQmZ27AvjaLfIWytioe/s320/Fichas+Tecnicas+-+ITED.bmp" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;/div&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/fichas-tcnicas-ited.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjsKO-rEzMvMjxb2esxowyZ8abaFw_upbASIHViOSO2rmgVtkQOIzzdXdmxTR6NkRiB-cl3zeQ9B67yTwT6gvexCOAVuuWCEYUIbP8i2gXpwbRD0JgcG3duDVCzNcsdFd6hWcpohDf3NQKJ/s72-c/Fichas+Tecnicas+-+ITED.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-2505897626066746490</guid><pubDate>Mon, 08 Oct 2007 18:29:00 +0000</pubDate><atom:updated>2007-10-20T20:45:35.203+01:00</atom:updated><title>PEÇAS DESENHADAS - ITED</title><description>&lt;div align="center"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;PEÇAS DESENHADAS DE UM PROJECTO DE ITED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;Loacalização Do Edificio - ITED&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119040825232787138" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjGyOmHfIcuHf1vusKrUnsIX4MExzwHYyatlJkzRbRgpUWaMceT4lhgpC-8s8ujZ-UBBPDBRSgM81-xzIpZwe-FT2M3mmIKX2u53f2ZBmXHqlD5MDcPAQjVtI0YDyCmDpdCNcoVsuGtj9AR/s320/Planta+de+localiza%C3%A7%C3%A3o+do+edificio.bmp" border="0" /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;Planta de localização de equipamentos terminais - &lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;/div&gt;&lt;img id="BLOGGER_PHOTO_ID_5119042010643760850" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiztJYlQ0O_IjZS0E8t06MxhHxFKglArFdSfJxnyH2kQfYmH8n7hXykbtihFYJlzIKwcFajDFAw82U_jzmabXJYnPtTLv-c2vcYCg2W0uKU-57mi3BFxH45UVA0eYVDrFTaQaoLjBXjoi-7/s320/Planta+de+localiza%C3%A7%C3%A3o+de+equipamentos+terminais+-+ITED.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p align="center"&gt;&lt;strong&gt;Esquema da rede de tubaguens - &lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt; &lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119042715018397410" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiq00ubzo5Gpgg1JUau79dxk8qkIXLV7p6qv3L981yqWxk6UA8V3_3X0JmCz7lSaCb1Cec_lU5HRrUdIwirQw2WA-UF1ATaEqRvQAtIIekoxxoehc5Kscdfjgywcb5lBkAkhUpg3N3pENJB/s320/Esquema+da+rede+de+tubaguens+-+ITED.JPG" border="0" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;p align="center"&gt;&lt;strong&gt;Esquema da rede de cabos PC - &lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;/p&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;img id="BLOGGER_PHOTO_ID_5119043161694996210" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhC0eKwXbEqPy2EE_tq2ADzuolG_RmUZDPxnXLwTHuFWiQyEg_8YMTP54RdggeE3LrwfMH9TZI0qO1EibrcuX03e_1Pl44VhmTMWASVQCQ6OpjaLQIH4T_pcu4aaBuMaFVC-28j19EhFUNL/s320/Esquema+da+rede+de+cabos+PC+-+ITED.JPG" border="0" /&gt;&lt;strong&gt;Esquema da rede de cabos CC - &lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;br /&gt;&lt;br /&gt;&lt;img id="BLOGGER_PHOTO_ID_5119043720040744706" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiZlXdag8SaA_PXoYaTHjEFtLR-e2kJPGAc7oLp3uF_QRl4FO7q5MrbRvwn6SdTcLk0oC-Cx6juF7jKga8BC3PxoybZVbXHFxmhgthhIJpHN5YiVefqGcUk1QYi4PGuOVXs7MBl0gXn7CZ8/s320/Esquema+da+rede+de+cabos+CC+-+ITED.JPG" border="0" /&gt;&lt;/div&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;strong&gt;Quadro Electrico - &lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119044570444269330" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjKHGDUs4F5G5tdKeFmJrSps7T5Nw5SrTeV_qRkkn3jYK1vX-7bTh0z8_sPCEj4kKJf1rDL8tPO7BOaEdPLGuVCLNVtIF2d2-ECbTjUToVkAzoLdeao7hHDcAkcRRL5wbEVOdaXhxfn5PR6/s320/Quadro+Electrico+-+ITED.JPG" border="0" /&gt;&lt;/p&gt;&lt;br /&gt;&lt;p align="center"&gt;&lt;strong&gt;Simbologia - &lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;br /&gt;&lt;p align="center"&gt;&lt;/p&gt;&lt;img id="BLOGGER_PHOTO_ID_5119045343538382626" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh8fh7gJJDnjK68IKm4Ml1OtY48rcSYZL8pGKwtqV-gnaX_sOC3wreWfQplThcYQLH1EnUYoEJTbNAmEHUURmLMDaciYUp47znJvsQx8-wX2rydBmR2KhBqKSG69I78GDRaWJEkgfWJHQuc/s320/Simbologia+-+ITED.JPG" border="0" /&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;/div&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/peas-desenhadas-ited.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjGyOmHfIcuHf1vusKrUnsIX4MExzwHYyatlJkzRbRgpUWaMceT4lhgpC-8s8ujZ-UBBPDBRSgM81-xzIpZwe-FT2M3mmIKX2u53f2ZBmXHqlD5MDcPAQjVtI0YDyCmDpdCNcoVsuGtj9AR/s72-c/Planta+de+localiza%C3%A7%C3%A3o+do+edificio.bmp" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-2962185427681122115</guid><pubDate>Mon, 08 Oct 2007 15:57:00 +0000</pubDate><atom:updated>2007-10-20T21:12:30.307+01:00</atom:updated><title>MEMÓRIA DESCRITIVA  DE UM PROJECTO DE ITED</title><description>&lt;div align="center"&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;PROJECTO DE INFRA-ESTRUTURAS DE TELECOMUNICAÇÕES EM EDIFICIOS&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;strong&gt;&lt;img id="BLOGGER_PHOTO_ID_5118996879127414450" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiYglV0-6JPD9RYaia7TN-bYX4FTDIVssmlXgfoOwsENjcn8koIPwNxHmm9ET4Iu9Hm4zOJzKuzHq69QZbrxpE_nxTsCXV7OUvyZCqiF-Gg91jV0fkvER3pzsxel2cXjmgpmLfuiC4Xl9We/s320/ITED.JPG" border="0" /&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;div align="center"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;MEMÓRIA DESCRITIVA&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;1. Generalidades&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;O Presente &lt;strong&gt;&lt;span style="font-size:180%;"&gt;Projecto&lt;/span&gt;&lt;/strong&gt; refere-se ás seguintes Infra-estruturas de Telecomunicações a executar no edifício a construir no local seguinte:&lt;br /&gt;&lt;br /&gt;Localidade: ___________________&lt;br /&gt;Conselho: ____________________&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;O presente &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt; de Infra-estruturas de Telecomunicações foi elaborado por&lt;br /&gt;&lt;br /&gt;___________&lt;br /&gt;Projectista de &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt; com o Nº__________,_________– _________&lt;br /&gt;Concelho de _____________&lt;/div&gt;&lt;div align="center"&gt;Telm: _________________&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;2. Concepção geral das Infra-estrutura&lt;/strong&gt;&lt;br /&gt;A estrutura do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt; foi elaborada em conformidade com o DL nº 59/2000&lt;br /&gt;de 19 de Abril, e a presente memória descritiva obedece aos critérios do Artº12 do mesmo DL. O presente documento contempla por isso as infra-estruturas de Telecomunicações. Estas infra-estruturas de Telecomunicações destinam-se a uma estabelecimento comercial.&lt;br /&gt;A instalação da moradia será constituída por 4 pontos terminais de ligação nos locais indicados na peça desenhada. Estes pontos terminais destinam-se á ligação de voz e, dados e sinais de CATV.&lt;br /&gt;&lt;br /&gt;A rede individual de distribuição garante os critérios seguintes:&lt;br /&gt;1 Distribuição de Sinais de tipo A e B&lt;br /&gt;2 Acesso a sistemas de SMATV&lt;br /&gt;3 Garantir uma boa recepção e Transição.&lt;br /&gt;4 Facilidade de evolução ou transformação&lt;br /&gt;5 Evitar a exposição a acções mecânicas, magnéticas e preservação da estética&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;3. Classificação do Local&lt;br /&gt;&lt;br /&gt;3.a. Quanto à Utilização&lt;/strong&gt;&lt;br /&gt;Comercio&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;3.b. Quanto ao Ambiente&lt;/strong&gt;&lt;br /&gt;AA4, AB4 e AD1&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;4. Níveis de qualidade&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;Tendo em conta os requisitos resultantes do disposto no DL 59/2000, nomeadamente o artigo 4º, quanto aos níveis de qualidade (NQ) das Infra-estruturas de Telecomunicações, o Mínimo a instalar para o edifício a que se destina o &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt; será:&lt;br /&gt;&lt;br /&gt;NQ1b (pares de cobre de categoria 5)&lt;br /&gt;NQ2b (Cablagem Coaxial à frequência de trabalho até 2150MHz)&lt;br /&gt;&lt;br /&gt;Os dispositivos e equipamentos usados no NQ1b, a cablagem utilizada na rede individual de cabos, deverão ser de categoria 5, ou superior.&lt;br /&gt;No NQ2b todos os materiais, dispositivos e equipamentos usados, deverão ter características de acordo com as características indicadas para os cabos coaxiais deste nível, de modo a garantir-se o cumprimento dos requisitos indicados nas &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;, de acordo com a EN50173-1 ou outras normas equivalentes.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;5. Entrada da Rede Pública&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Após levantamento na área do edifício supracitado, foi definido que a Entrada de Cabos deverá ser constituída por uma entrada subterrânea (Es) interligada com as caixas de visita dos operadores públicos de telecomunicações, por acordo de todas as partes interessadas, e uma entrada aérea (Ea).&lt;br /&gt;&lt;br /&gt;As condutas para as respectivas entradas deverão ter os diâmetros indicados nas peças desenhadas e serem do tipo (PVC) devidamente certificados.&lt;br /&gt;Deverão ser respeitada a profundidade mínima para as condutas de entrada, evitando a penetração de humidades na caixa de Entrada e á profundidade mínima de 600mm do nível do solo.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Será colocada uma caixa de entrada de cabos (&lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt;) e deverá estar localizada numa zona acessível aos operadores públicos de telecomunicações, no limite da propriedade como o desenhado nas peças. Contém no seu interior os dispositivos necessários de interligação entre as redes públicas de telecomunicações (RD) e a rede de cabos do edifício (RCE).&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;6. Espaços&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; (Armário de Telecomunicações Individual) destinado á colocação de Dispositivos (passivos e activos) instalado dentro da fracção individual, permite a interligação dos cabos (pares de cobre e cabos coaxiais) provenientes do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; á restante rede individual.&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, deve satisfazer as seguintes características e requisitos técnicos mínimos:&lt;br /&gt;&lt;br /&gt;1 As caixas têm de ser não metálicas (exemplo: plástico). Poderão no entanto conter partes metálicas, como por exemplo reforços de estrutura ou painéis para fixação de tomadas e dispositivos.&lt;br /&gt;2 Protecção contra impactos mecânicos com uma energia de 0,2 joule.&lt;br /&gt;3 Resistentes à propagação da chama;&lt;br /&gt;4 Identificadas com a palavra “telecomunicações”, marcada de forma indelével na face exterior da porta.&lt;br /&gt;5 As dimensões interiores mínimas do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, são (200x3000x100), onde a largura poderá ser trocada pela altura, permitindo o melhor posicionamento do armário:&lt;br /&gt;6 Terá no seu interior um mini Bastidor adaptado ao nº de tomadas PC, 2 TC e uma tomada de corrente 230V 16A AC 50 a 60Hz com terra.&lt;br /&gt;7 O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; é obrigatoriamente constituído por 2 zonas distintas, uma acessível ao cliente permitindo a troca dos pachcords e outra de acesso restrito aos técnicos de &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;.&lt;br /&gt;&lt;br /&gt;Do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; sai um tubo, com o diâmetro mínimo de 20mm a uma caixa de aparelhagem do tipo I1, permitindo a ligação de equipamentos activos de cliente que não possam estar no interior do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, nomeadamente uma WLAN (Wireless Local Area Network).&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;7. Rede de Tubagens&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;7. a . Tubos&lt;br /&gt;&lt;/strong&gt;Toda a rede de tubagens , será executada em tubo do tipo (PVC), devidamente certificado e normalizado, com os diâmetros indicados no respectivo esquema da rede de Tubagens.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;No &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; irá entrar a entrada subterrânea (Es) com 3 tubos de diâmetro 63 e desta ao &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; 2 tubos, de diâmetro 40. No &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; irá entrar as PAT com 2 tubos de diâmetro 40.&lt;br /&gt;&lt;br /&gt;Do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; para as tomadas de equipamentos terminais irão sair tubos de diâmetro 20 mm como mínimo.&lt;br /&gt;&lt;br /&gt;O diâmetro representado nas peças desenhadas e o diâmetro comercial.&lt;br /&gt;Toda a rede de tubos será representada nas peças desenhadas&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;7. b . Caixas&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Para alojar os dispositivos de transição entre a rede pública de Telecomunicações e a rede individual de cabos, deverá ser instalada uma caixa de ligação de cabos &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt; e &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;.&lt;br /&gt;As caixas a utilizar na rede individual são do tipo I1 e I2.&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="center"&gt;&lt;strong&gt;8. Rede de Cabos do edifício (RCc)&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;Em conformidade com as &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt; em vigor farão parte desta rede todos os cabos, equipamentos activos e passivos correspondentes às duas tecnologias.&lt;br /&gt;&lt;br /&gt;A rede de pares de cobre, será executada com cabos da categoria 5 ou do tipo UTP ou superior ( STP, FTP), cuja capacidade em pares é de 4/ está indicada no esquema rede de cabos.&lt;br /&gt;&lt;br /&gt;Os cabos coaxiais a utilizar nas redes de cabos coaxial, deverão ter as seguintes características Mínimas:&lt;br /&gt;• Flexíveis;&lt;br /&gt;• Impedância característica de 75Ω;&lt;br /&gt;• Cobertura da malha de blindagem não inferior a 70% da superfície do dieléctrico;&lt;br /&gt;• Frequências de trabalho até 2150 MHz adequado à distribuição dos sinais do NQ 2b.&lt;br /&gt;Poderão ser utilizados cabos RG 59, RG6, RG7, RG11 tal como estão representados nos esquemas de cabos coaxiais.&lt;br /&gt;&lt;br /&gt;As redes de cabos dos sistemas de uso exclusivo do edifício, nomeadamente os sistemas de portaria, vídeo-portaria e televigilância, utilizam uma rede de tubagem específica, embora se permita a interligação com as redes das &lt;span style="font-size:180%;"&gt;&lt;strong&gt;ITED&lt;/strong&gt;&lt;/span&gt;, esta interligação será da responsabilidade das entidades responsáveis por estes sistemas.&lt;br /&gt;&lt;br /&gt;A distribuição será em estrela, partindo do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; até às tomadas terminais do tipo TV/Sat. Os níveis de sinal à entrada da cabeça de rede dos cabos coaxiais são de 75dBµV para a frequência 85MHz de 80dBµV para a frequência de 2150MHz.&lt;br /&gt;&lt;br /&gt;. Tomadas&lt;br /&gt;&lt;br /&gt;Em conformidade com as normas aplicáveis, estas serão do tipo RJ 45 (8 pinos), coaxial (TV/SAT) e tomadas mistas ou de espelho comum (dada a existência de diferentes tecnologias de cabos a partilhar a mesma rede individual de tubagens), instaladas em caixas do tipo I1 embebidas na parede a uma altura mínima de 300mm do chão acabado.&lt;br /&gt;Serão instaladas as tomadas e cabos que constam na peça desenhada e nos locais indicados.&lt;br /&gt;&lt;br /&gt;. Derivadores e repartidores, receptores e amplificadores&lt;br /&gt;&lt;br /&gt;Na escolha destes equipamentos deverão ser essencialmente escolhidos em função dês seguintes características:&lt;br /&gt;1 Largura de banda (Hz)&lt;br /&gt;2 Perdas de passagem (dB)&lt;br /&gt;3 Perdas de derivação (dB)&lt;br /&gt;4 Perdas de Inserção (db)&lt;br /&gt;5 Isolamento à corrente DC&lt;br /&gt;6 Numero de derivações necessárias&lt;br /&gt;7 Banda de frequências necessárias (Hz)&lt;br /&gt;8 Relação Sinal Ruído (dB)&lt;br /&gt;9 Compatibilidade Electromagnética&lt;br /&gt;10 Factor de segurança para o utilizador&lt;br /&gt;11 Ganhos (dB)&lt;br /&gt;12 Consumos (W)&lt;br /&gt;13 Certificados de Conformidade&lt;br /&gt;14 Relação preço qualidade&lt;br /&gt;&lt;br /&gt;.&lt;br /&gt;. Antenas&lt;br /&gt;&lt;br /&gt;As antenas e os respectivos sistemas de recepção, amplificação e outros, são parte integrante dos sistemas de cablagem para a distribuição de sinais sonoros e televisivos, dos tipos A e B, bem como FWA.&lt;br /&gt;As antenas são instaladas em mastros ou torres, de forma a poderem assegurar a correcta captação dos sinais de radiodifusão sonora e televisiva. Assim, as antenas e respectivos elementos de suporte, fixação e amarração, devem obedecer aos seguintes requisitos mínimos:&lt;br /&gt;1 Constituídos por materiais resistentes à corrosão, ou com a garantia de um tratamento anticorrosivo;&lt;br /&gt;2 Concebidos de modo a impedir, ou dificultar, a entrada de água no interior;&lt;br /&gt;3 Concebidos de forma a assegurar o escoamento de água que eventualmente penetre nos mesmos;&lt;br /&gt;4 Resistentes a ventos com velocidade aproximada de:&lt;br /&gt;- 130Km/h, para instalações até 20m de altura;&lt;br /&gt;- 150Km/h, para instalações superiores a 20 m de altura&lt;br /&gt;&lt;br /&gt;NOTA: A altura é medida desde a base de fixação do mastro da antena.&lt;br /&gt;1 Os suportes, mastros, torres e amarrações devem ser fixados a elementos de construção resistentes e acessíveis, em locais afastados de outras estruturas de antenas ou pára-raios;&lt;br /&gt;2 As antenas devem ser protegidas contra descargas atmosféricas de acordo com as &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;.&lt;br /&gt;&lt;br /&gt;Para este edifício recomenda-se a colocação do sistema de MATV+FI da TELEVÉS, do qual se representa o esquema de ligações deste equipamento.&lt;br /&gt;&lt;br /&gt;Na instalação de antenas devem ser tidos em conta as publicações seguintes:&lt;br /&gt;• Decreto-lei nº 151-A/2000, de 20 de Julho;&lt;br /&gt;• Decreto Regulamentar nº 1/92, de 18 de Fevereiro;&lt;br /&gt;• Quadro Nacional de Atribuição de Frequências (publicação ICP-ANACOM);&lt;br /&gt;• Publicitação de Frequências (publicação ICP-ANACOM);&lt;br /&gt;• Limitações em Altura e Balizagem de Obstáculos Artificiais à Navegação Aérea;&lt;br /&gt;• Outras normas ou regulamentos equivalentes desde que obedeçam aos requisitos mínimos indicados.&lt;br /&gt;&lt;br /&gt;As antenas e equipamentos a instalar deverão garantir os níveis de sinal mínimos á cabeça de rede compreendidos entre os 75 e 100 dBmV, permitindo captar sinais de tipo B.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;A escolha da antena será escolhida mediante os seguintes factores:&lt;br /&gt;1 Canais pretendidos&lt;br /&gt;2 Selectividade (largura de banda)&lt;br /&gt;3 Ângulo de abertura&lt;br /&gt;4 Ganho&lt;br /&gt;5 Relação frente trás (dB)&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;9. Órgãos de Protecção&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Deverão ser seguidas as indicações constantes das Normas Europeias aplicáveis, nomeadamente as constantes da EN 50310 e as previstas no regulamento de segurança de instalações eléctricas (RSIUEE).&lt;br /&gt;O &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt; será dotado de tomadas de corrente 230 VAC 50 a 60Hz com ligação á terra, será necessário a existência de um barramento de terras de protecção no lado inferior direito dos armários, para a ligação deste barramento ao Barramento Geral de terras do Edifício (BGTE) o condutor de terra de protecção será do tipo H07V - U 2.5 mm2 com as cores verde/amarelo ou verde/vermelho.&lt;br /&gt;O BGTE será ligado ao eléctrodo de terra com um cabo H05 V – U 2.5mm2.&lt;br /&gt;&lt;br /&gt;Considera-se, assim, a existência de um único eléctrodo de terra no edifício, projectado e instalado pelos responsáveis da parte eléctrica.&lt;br /&gt;&lt;br /&gt;No caso dos mastros serem ligados á terra, estes só poderão ser ligados ao BGT se possuírem descarregadores atmosféricos caso contrário terá de ser efectuada uma ligação á terra independente da terra de protecção&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;10. Testes, Ensaios e Medições&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;Após todos os trabalhos referentes à instalação estarem terminados, esta só será dada por concluída quando tiverem sido efectuados os seguintes Ensaios, medições e Testes&lt;br /&gt;Na realização de ensaios nas &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;, a entidade certificadora e o instalador deverão ter em consideração o &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt; técnico e os requisitos do presente manual &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;.&lt;br /&gt;A finalidade dos ensaios, é verificar as características da instalação, nomeadamente no respeitante às redes de cabos e aos sistemas de cablagem.&lt;br /&gt;A entidade certificadora emite um certificado em que atesta o cumprimento das Prescrições e especificações Técnicas que constituem o presente Manual, baseado no seguinte:&lt;br /&gt;1 &lt;strong&gt;&lt;span style="font-size:180%;"&gt;Projecto&lt;/span&gt;&lt;/strong&gt; técnico e eventual &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt; de alterações;&lt;br /&gt;2 Relatório de ensaios de funcionalidade do instalador;&lt;br /&gt;3 Ensaios e inspecções realizadas.&lt;br /&gt;&lt;br /&gt;Resistência de terra e de contacto (todos os NQ)&lt;br /&gt;O ensaio de resistência de terra é obrigatório qualquer que seja o NQ.&lt;br /&gt;Dado não existir definido um valor fixo de resistência de terra, os disjuntores diferenciais deverão estar adaptados ao valor de resistência de terra existente, de modo a que nas partes metálicas acessíveis dos equipamentos e materiais das &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;, não possa surgir uma tensão de contacto superior ao máximo regulamentado no RSIUEE.&lt;br /&gt;O ensaio de resistência de terra é realizado pelo instalador e pela entidade certificadora.&lt;br /&gt;10. a. Ensaios a realizar nas cablagens em par de cobre (NQ1b)&lt;br /&gt;&lt;br /&gt;Continuidade&lt;br /&gt;Com este ensaio pretende verificar-se a continuidade eléctrica dos condutores, os eventuais curto-circuitos ou circuitos abertos, pares trocados ou invertidos.&lt;br /&gt;&lt;br /&gt;Atenuação (em dB)&lt;br /&gt;A atenuação, ou perdas por inserção, pretende calcular a quantidade de energia perdida pelo sinal através da sua propagação no cabo.&lt;br /&gt;&lt;br /&gt;NEXT (em dB)&lt;br /&gt;O ensaio de NEXT (“Near End Cross Talk”), tem como objectivo detectar possíveis induções electromagnéticas entre condutores de pares diferentes. A medida é efectuada junto ao “transmissor”, onde a indução é mais elevada. Quando os valores calculados para a atenuação nas Classes D, E e F forem inferiores a 4.0 dB, o ensaio de NEXT não é necessário.&lt;br /&gt;&lt;br /&gt;ACR (em dB)&lt;br /&gt;O ensaio de ACR (“Attenuation to Crosstalk Ratio”), mede a relação atenuação/diafonia. É um bom indicador de qualidade da ligação.&lt;br /&gt;&lt;br /&gt;Perdas por retorno (em dB)&lt;br /&gt;Este ensaio permite medir a perda de potência de um sinal, devido a desadaptações de impedância.&lt;br /&gt;&lt;br /&gt;Resistência de lacete&lt;br /&gt;Este ensaio mede a resistência combinada de um par de cobre, como se ele estivesse em curto-circuito nas extremidades.&lt;br /&gt;&lt;br /&gt;Atraso de propagação (em s)&lt;br /&gt;O ensaio de atraso de propagação mede o tempo que o sinal demora a propagar-se no cabo.&lt;br /&gt;Atraso diferencial (em s)&lt;br /&gt;Este ensaio mede a diferença do atraso de propagação entre pares do mesmo cabo.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;PSNEXT (em dB)&lt;br /&gt;O ensaio de PSNEXT (“Power Sum NEXT”) é a soma dos NEXT de outros pares, que são recebidos num determinado par.&lt;br /&gt;&lt;br /&gt;PSACR (em dB)&lt;br /&gt;O ensaio de PSACR (“Power Sum ACR”) é a soma dos ACR de outros pares, que são recebidos num determinado par.&lt;br /&gt;&lt;br /&gt;ELFEXT (em dB)&lt;br /&gt;O FEXT (“Far End Cross Talk”) mede a perda de sinal (em dB), que ocorre quando um sinal gerado numa extremidade de um par de cobre é recebido numa outra extremidade de um outro par de cobre. O ensaio de ELFEXT (“Equal Level Near End Cross Talk”) mede a diferença entre o FEXT e a atenuação de um par de cobre.&lt;br /&gt;&lt;br /&gt;PSELFEXT (em dB)&lt;br /&gt;Este ensaio (“Power Sum ELFEXT”) é a soma dos FEXT menos a atenuação de um determinado par de cobre.&lt;br /&gt;10.b Ensaios a realizar nas cablagens coaxiais (NQ2b)&lt;br /&gt;&lt;br /&gt;Níveis de sinal nas tomadas de cliente (em dB ou dBµV)&lt;br /&gt;Este ensaio permite verificar a qualidade e a funcionalidade do sinal nas tomadas de cliente. Consta do ensaio do nível da portadora, relações C/N (portadora/ruído), CSO (distorções de 2º grau) e CTB (distorções de 3º grau).&lt;br /&gt;&lt;br /&gt;Atenuação (em dB)&lt;br /&gt;A atenuação, ou perdas por inserção, pretende calcular a quantidade de energia perdida pelo sinal através da sua propagação no cabo coaxial.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Continuidade&lt;br /&gt;Este ensaio permite verificar a continuidade eléctrica da cablagem coaxial (cabos, conectores e sistemas associados) e os eventuais curtos-circuitos ou circuitos abertos.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Isolamento&lt;br /&gt;Este ensaio permite medir a resistência de isolamento entre os cabos ou entre cabos e equipamentos associados.&lt;br /&gt;1 – Ensaios não obrigatórios mas possíveis de realizar, nomeadamente nas redes de MATV.&lt;br /&gt;2 – Estes ensaios só se justificam se os valores encontrados para os níveis da portadora, diferirem mais ou menos 3 dBµV dos valores estabelecidos no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt;. Nesse caso deverão ser realizados os ensaios possíveis e convenientes, de forma a identificarem-se e corrigirem-se as eventuais anomalias.&lt;br /&gt;Os ensaios são realizados pelo instalador e pela entidade certificadora.&lt;br /&gt;10. c Valores e níveis de sinal&lt;br /&gt;Ensaio dos níveis das portadoras nas tomadas de utilizador&lt;br /&gt;Este ensaio consiste em alimentar as &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;, à entrada do dispositivo terminal presente na CEMU com o nível de sinal referido no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt; às frequências piloto correspondentes, o que permite a leitura, nas tomadas de cliente, dos níveis das portadoras.&lt;br /&gt;Os valores encontrados neste ensaio deverão estar de acordo com:&lt;br /&gt;• Os níveis previstos no &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt;. Admite-se no entanto a possibilidade de existir uma diferença máxima de mais ou menos 3dBentre o medido e o projectado, não havendo necessidade de qualquer correcção.&lt;br /&gt;Os níveis serão medidos às frequências piloto de 85; 750; 1000 e 2150&lt;br /&gt;Os níveis das portadoras de sinal de radiodifusão sonora e televisiva, nas tomadas de utilizador terão comportar as seguintes frequências; 85 a 750MHz e 1000 A 2150 MHz&lt;br /&gt;&lt;br /&gt;.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;11.OMISSOS&lt;br /&gt;&lt;/strong&gt;&lt;br /&gt;Em tudo o que não seja estipulado na presente memória, plantas e demais elementos do &lt;strong&gt;&lt;span style="font-size:180%;"&gt;projecto&lt;/span&gt;&lt;/strong&gt;, respeitar-se-á, nas partes omissas as Prescrições e Especificações Técnicas, Normas e Regulamento em vigor.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;________, __ de _______ de ______&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;O projectista responsável&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;___________________________________&lt;br /&gt;(nome) &lt;/div&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/memria-descritiva-de-um-projecto-de.html</link><author>noreply@blogger.com (Unknown)</author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" height="72" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiYglV0-6JPD9RYaia7TN-bYX4FTDIVssmlXgfoOwsENjcn8koIPwNxHmm9ET4Iu9Hm4zOJzKuzHq69QZbrxpE_nxTsCXV7OUvyZCqiF-Gg91jV0fkvER3pzsxel2cXjmgpmLfuiC4Xl9We/s72-c/ITED.JPG" width="72"/></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-3438216281170652716</guid><pubDate>Mon, 08 Oct 2007 15:41:00 +0000</pubDate><atom:updated>2007-10-20T20:27:28.693+01:00</atom:updated><title>TERMO DE RESPONSABILIDADE DO PROJECTO DE ITED</title><description>&lt;div align="center"&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;TERMO DE RESPONSABILIDADE - ITED&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Eu, __________________________, portador do BI n.º _________ emitido pelo arquivo de Identificação de _______ em __/__/__, domiciliado em __________________, com categoria profissional Técnico Projectista de &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt; com inscrição na &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ANACOM&lt;/span&gt;&lt;/strong&gt; sob o n.º___________ declaro-me responsável, nos termos do Artº 8º do DL nº 59/2000 de 19 de Abril, pelo Projecto das Infra-estruturas de Telecomunicações do ________________, situado _______________________nº__, na freguesia de ________________, concelho de _________________________, de acordo com a regulamentação, especificação e condições técnicas em vigor.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div align="center"&gt;___________, __ de ____________ de ____&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;O Projectista,&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;____________________________________________&lt;br /&gt;(nome)&lt;br /&gt;&lt;/div&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/termo-de-responsabilidade-do-projecto.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-6383277921629744108</guid><pubDate>Mon, 08 Oct 2007 15:33:00 +0000</pubDate><atom:updated>2007-10-20T20:56:00.409+01:00</atom:updated><title>ELABORAÇÃO DE PROJECTO DE ITED</title><description>&lt;strong&gt;&lt;span style="font-size:180%;"&gt;ELABORAÇÃO DE PROJECTO DE ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;•Fichas técnicas&lt;br /&gt;•Memória descritiva&lt;br /&gt;•Planta topográfica de localização do edifício&lt;br /&gt;•Plantas de cada um dos pisos que constituem o edifício, com o traçado das redes e localização das tomadas de cliente, tomando em consideração o local de instalação dos equipamentos terminais&lt;br /&gt;•Desenho, nessas mesmas plantas, da localização das entradas de cabos, dos &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATE&lt;/span&gt;&lt;/strong&gt;, dos &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ATI&lt;/span&gt;&lt;/strong&gt;, da &lt;strong&gt;&lt;span style="font-size:180%;"&gt;PAT&lt;/span&gt;&lt;/strong&gt;, das caixas de passagem, de derivação, de saída e do respectivo traçado de interligação&lt;br /&gt;•Inscrição nos esquemas das capacidades dos dispositivos e cabos, da dimensão da tubagem e do tipo das caixas। (deverá ser inscrito o tipo de ambiente)&lt;br /&gt;•Esquema da rede de tubagens&lt;br /&gt;•Esquema da rede de cabos&lt;br /&gt;•Quadro de dimensionamento para os &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabos de par de cobre&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;•Quadro de dimensionamento para os &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabos coaxiais&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;•Quadro de dimensionamento para os &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabos de fibras ópticas&lt;/span&gt;&lt;/strong&gt; (quando existam)&lt;br /&gt;•Fichas dos repartidores gerais&lt;br /&gt;•Fichas para as caixas de derivação e fichas de encaminhamento para os cabos par de cobre&lt;br /&gt;•Fichas para as caixas de derivação e fichas de encaminhamento para os cabos coaxiais e fibras ópticas&lt;br /&gt;•Cálculo dos níveis de sinal nas redes de &lt;strong&gt;&lt;span style="font-size:180%;"&gt;cabo coaxial&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;•Esquema da instalação eléctrica das &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;•Indicação dos materiais, marcas, modelos e tipos, a instalar nas &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;•Termo de responsabilidade&lt;br /&gt;•Escala mínima das plantas para elaboração dos desenhos deverá ser de 1:100&lt;br /&gt;•No esquema da rede de tubagens é necessário representar a caixa de entrada de cabos, bem como todas as entradas consideradas, respectivo dimensionamento e símbolos&lt;br /&gt;•Para a rede de cabos &lt;strong&gt;&lt;span style="font-size:180%;"&gt;PC&lt;/span&gt;&lt;/strong&gt; são registadas, na &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ficha RG-PC&lt;/span&gt;&lt;/strong&gt; ou do RG-PC+&lt;br /&gt;•Para as &lt;strong&gt;&lt;span style="font-size:180%;"&gt;redes de CC e FO&lt;/span&gt;&lt;/strong&gt;, deverão ser indicadas nos esquemas e no respectivo quadro de dimensionamento&lt;br /&gt;•Os esquemas deverão ainda conter as antenas para os sistemas de recepção do tipo A,B e FWA, bem como os respectivos suportes, mastros ou torres, como parte integrante das &lt;strong&gt;&lt;span style="font-size:180%;"&gt;ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;•Quando o projecto definir de postos principais com comutação automática (PPCA), devem ser apresentados juntamente com a documentação definida, os esquemas de ligação destes à tomada&lt;br /&gt;•Se o projectista considerar conveniente, poderão ser preparados outros documentos complementares</description><link>http://electricidade-ited.blogspot.com/2007/10/elaborao-de-projecto-de-ited.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-8783245413079732587</guid><pubDate>Mon, 08 Oct 2007 15:28:00 +0000</pubDate><atom:updated>2007-10-20T20:24:09.995+01:00</atom:updated><title>ELEMENTOS OBRIGATÓRIOS PARA PROJECTO DE ITED</title><description>&lt;strong&gt;&lt;span style="font-family:arial;font-size:180%;"&gt;Elementos obrigatóriosao projectoart. 12 59/२००० - ITED&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;a)Informação identificadora do projectista, do edifício a que se destina&lt;br /&gt;&lt;br /&gt;b)Memória descritiva, contendo:&lt;br /&gt;&lt;br /&gt;- os esclarecimentos necessários à correcta interpretação do projecto&lt;br /&gt;&lt;br /&gt;- os pressupostos que foram considerados ( interfaces das redes públicas)&lt;br /&gt;&lt;br /&gt;- cálculos técnicos dos parâmetros principais da infra-estrutura&lt;br /&gt;&lt;br /&gt;- referência ao modo como o projecto assegura a não interferência com outras infra-estruturas&lt;br /&gt;&lt;br /&gt;- características técnicas a que devem obedecer os materiais e equipamentos&lt;br /&gt;&lt;br /&gt;- informação especifica sobre as condições dos trabalhos de instalação</description><link>http://electricidade-ited.blogspot.com/2007/10/elementos-obrigatrios-ao-projecto-ited.html</link><author>noreply@blogger.com (Unknown)</author></item><item><guid isPermaLink="false">tag:blogger.com,1999:blog-8798529497783667034.post-460466505768080431</guid><pubDate>Mon, 08 Oct 2007 15:21:00 +0000</pubDate><atom:updated>2007-10-20T20:51:54.543+01:00</atom:updated><title>METEDOLOGIA PARA  ELABORAÇÃO DE PROJECTO - ITED</title><description>&lt;div align="left"&gt;&lt;strong&gt;&lt;span style="font-size:180%;"&gt;METEDOLOGIA PARA ELABORAÇÃO DE PROJECTO - ITED&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;1ª Fase&lt;br /&gt;&lt;/strong&gt;(obtenção das seguintes informações preliminares)&lt;br /&gt;&lt;br /&gt;•Localização exacta do edifício&lt;br /&gt;•Fim a que se destina o edifício&lt;br /&gt;•Numero e características das fracções das&lt;br /&gt;•Fracções autónomas&lt;br /&gt;•Especificação técnica do interface de redes&lt;br /&gt;•Contacto com o dono de obra e eventualmente com os operadores&lt;br /&gt;•Recomenda-se, nesta fase, a aproximação de uma entidade certificadora &lt;/div&gt;&lt;div align="left"&gt;&lt;/div&gt;&lt;div align="left"&gt;&lt;br /&gt;&lt;strong&gt;•2 ª fase&lt;/strong&gt;&lt;br /&gt;•Elaboração do projecto conforme o descrito no ponto 4.6.7&lt;br /&gt;&lt;/div&gt;&lt;div align="left"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div align="left"&gt;&lt;strong&gt;•3 ª fase&lt;br /&gt;&lt;/strong&gt;•Elaboração de um termo de responsabilidade do projectista conforme o previsto no artigo 8 do &lt;/div&gt;&lt;div align="left"&gt;&lt;/div&gt;&lt;div align="left"&gt;DL 59 /2000&lt;br /&gt;•Nota: o projecto técnico deve incluir os elementos previstos no artigo 12 do DL 59/2000 &lt;/div&gt;</description><link>http://electricidade-ited.blogspot.com/2007/10/metodologia-para-elaborao-de-projecto.html</link><author>noreply@blogger.com (Unknown)</author></item></channel></rss>