<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:blogger='http://schemas.google.com/blogger/2008' xmlns:georss='http://www.georss.org/georss' xmlns:gd="http://schemas.google.com/g/2005" xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-3322876698640921979</id><updated>2026-08-15T09:03:16.897+05:30</updated><category term="Artificial Eye"/><category term="ocularist"/><category term="Artificial Eye India"/><category term="India Ocularists"/><category term="Nusrat Changal"/><category term="Ocularist India"/><category term="Artificial Eye Making"/><category term="eye prosthesis"/><category term="ocular prosthesis or artificial eye"/><category term="ocularist lvpei"/><category term="Artificial Eyes India"/><category term="Artificial eye advantages and disadvantages"/><category term="Chinmaya Ocular prosthetics"/><category term="India  Ocularists in India"/><category term="New Delhi"/><category term="Notable people with glass eye"/><category term="ORBITAL IMPLANTS"/><category term="Ocular Prosthesis"/><category term="Ocularists"/><category term="Prosthetic clinic at at L V Prasad Eye Institute Hyderabad"/><category term="enucleation"/><category term="lvpei ocularist"/><category term="ocular prosthesis or artificial eye india"/><category term="Anophthalmia"/><category term="Articles for Prosthetic eye"/><category term="Artificial Eye  Care Prosthesis manufactures"/><category term="Artificial Eye For The Blind"/><category term="Artificial Eye Lens"/><category term="Artificial Eye Manufacturers"/><category term="Artificial Eye Manufacturers Suppliers"/><category term="Artificial Eyebrows"/><category term="Artificial Eyes  Bengaluru"/><category term="Artificial Eyes Bangalore"/><category term="Artificial Eyes Karnataka"/><category term="Artificial Eyes Kerala"/><category term="Artificial eye abstract"/><category term="Artificial eye fitting"/><category term="Basics"/><category term="Benefits of Prosthetic Eye"/><category term="CYCLODESTRUCTIVE PROCEDURES"/><category term="Cali Kolbergs"/><category term="Celia Vinny (L V Prasad Eye Institute)vinny celia"/><category term="Chennai"/><category term="Contracted eye socket reconstruction"/><category term="Dacryology"/><category term="Diwakar Raj ( Ocularist)"/><category term="Diwakar Raj Ocularist"/><category term="EVISCERATION"/><category term="EXENTRATION"/><category term="Eric"/><category term="FUSION International Masters&#39; Course Pediatric Ophthalmology"/><category term="Facial Aesthetics"/><category term="Glossary of OCULAR PROSTHETICS"/><category term="Good Artificial Eyes"/><category term="Guides"/><category term="History"/><category term="Human Eye Conditions"/><category term="Implant movement"/><category term="Implant types and chemical construction"/><category term="India"/><category term="India  -Ocularists in India"/><category term="India -Diwakar Raj Ocularist"/><category term="LVPEI Ocularists"/><category term="Lindsay Wagner Pronk"/><category term="M-Sphere® Orbital Implant Patient Information"/><category term="Making an Artificial Eye"/><category term="OCULARIST VIDEO"/><category term="Ocular Illusions"/><category term="Ocular Oncology"/><category term="Ocular prosthesis (artificial eyes) camp in chennai"/><category term="Ocularist  and  Artificial Eye Specialist in India"/><category term="Ocularist Bangalore"/><category term="Ocularist Karnataka"/><category term="Orbital Reconstruction After Repeat Orbital Exenteration"/><category term="RAW MATERIALS"/><category term="Raju Kumar- Ocularist"/><category term="Retinal Implant"/><category term="Sachin Gupta"/><category term="Sammy"/><category term="Strabismus  Oculoplasty"/><category term="Surgical procedure"/><category term="THE NECESSITY OF AN ARTIFICIAL EYE"/><category term="The Ocularist"/><category term="The Visual System"/><category term="Video for Prosthetic eye"/><category term="WHO IS ELIGIBLE ?"/><category term="What is artificial eye"/><category term="Whats is artificial eye"/><category term="amp; Kami"/><category term="artificial eye Wikipedia"/><category term="artificial eye cost"/><category term="artificial eye drops"/><category term="artificial eye introduction"/><category term="artificial eye ppt"/><category term="artificial eyelashes"/><category term="artificial eyelashes price"/><category term="bionic eye"/><category term="celia vinny"/><category term="eye loss"/><category term="eye removal"/><category term="kerala ocularist"/><category term="maintenance"/><category term="ocularist kerala"/><category term="prosthetic eyes"/><category term="video ocularist"/><title type='text'>Ocularist and Artificial Eyes in  India</title><subtitle type='html'>Ocularist India  gives best  advise for  the  the  patients  for Artificial Eye</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default?redirect=false'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><link rel='next' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default?start-index=26&amp;max-results=25&amp;redirect=false'/><author><name>Celia Vinny</name><uri>http://www.blogger.com/profile/07138172099486501120</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>145</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-5805308916255206508</id><published>2020-04-29T08:00:00.000+05:30</published><updated>2020-04-28T20:39:39.452+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Artificial Eye For The Blind"/><title type='text'>Artificial Eye For The Blind</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;iframe src=&quot;//www.slideshare.net/slideshow/embed_code/key/jkdyUpCDGDQU6D&quot; width=&quot;595&quot; height=&quot;485&quot; frameborder=&quot;0&quot; marginwidth=&quot;0&quot; marginheight=&quot;0&quot; scrolling=&quot;no&quot; style=&quot;border:1px solid #CCC; border-width:1px; margin-bottom:5px; max-width: 100%;&quot; allowfullscreen&gt; &lt;/iframe&gt; &lt;div style=&quot;margin-bottom:5px&quot;&gt; &lt;strong&gt; &lt;a href=&quot;//www.slideshare.net/VineethSundar1/artificial-eye-for-the-blind&quot; title=&quot;Artificial Eye For The Blind&quot; target=&quot;_blank&quot;&gt;Artificial Eye For The Blind&lt;/a&gt; &lt;/strong&gt; from &lt;strong&gt;&lt;a href=&quot;https://www.slideshare.net/VineethSundar1&quot; target=&quot;_blank&quot;&gt;Vineeth Sundar&lt;/a&gt;&lt;/strong&gt; &lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
1. ARTIFICIAL EYE&lt;br /&gt;2.  Introduction  Components required  Working of artificial vision  Another approach to this  Advantages and disadvantages  Future scope  Conclusion&lt;br /&gt;3. INTRODUCTION • There are 10 billion people in the US who are blind or facing blindness due to diseases of the retina… and there’s little that can be done for them. • For the vast majority, their best hope is through prosthetic devices. • The U.S. Food and Drug Administration (FDA) has market approval to an artificial retina technology, the first bionic eye to be approved for patients in the U.S.&lt;br /&gt;4. Continued… • Scientists claim to have developed a new revolutionary bionic eye that enables blind people to read letters and simple words. • In the mid-20th century, researchers began to explore the idea of creating an artificial eye which could actually see.&lt;br /&gt;5. ARTIFICIAL EYE? • An artificial eye is a prosthesis which is used to replace a missing or damaged eye. • In order to accomplish the goal of creating a visual prosthesis, scientists had to develop a camera which could interact with the brain by stimulating the optic nerve.&lt;br /&gt;6. What happens when we look at an object?  Scattered light from the object enters through the cornea.  The light is projected onto the retina.  The retina sends messages to the brain through the optic nerve.  The brain interprets what the object is.&lt;br /&gt;7. HOW BRAIN WORKS AFTER SEEING AN IMAGE? • After seeing an image the brain takes information from the outside world and encodes it in patterns of electrical activity. • After the creating pattern the brain get an visualization of an image. That can we actually seeing the image from our eyes.&lt;br /&gt;8. Continued…. • In damaged or dysfunctional retina, the photoreceptors stop working, causing blindness • The absence of effective therapeutic remedies for retinitis pigmentosa (RP) and age-related macular degeneration (AMD)&lt;br /&gt;9. ARGUS-II DEVICE  The Argus II Retinal Prosthesis System (“Argus II”) is the world’s first approved device intended to restore some functional vision for people suffering from blindness. transmits images from a small, eye-glass- mounted camera wirelessly to a microelectrode array implanted on a patient’s damaged retina.&lt;br /&gt;10. Artificial silicon retina • Tiny device of diameter 2mm • Thinner than human hair • ASR implantations are two types • Epiretinal and subretinal&lt;br /&gt;11. PARTS OF ARGUS II DEVICE The System has three parts: • a small electronic device implanted in and around the eye, • a tiny video camera attached to a pair of glasses, • and a video processing unit that is worn or carried by the patient.&lt;br /&gt;12. Digital Camera • The camera used for this is the CMOS image sensor. • The camera captures the image and converts it into pixels of black and white. • This camera is placed on the goggles. • The battery required for this is provided from the video processing unit.&lt;br /&gt;13. Video Processing Unit • Video Processing Unit acts as a optogenic transducer unit which simplifies the image as spots of light and then reduces the image to the number of photodiodes. • This is connected to goggles through router. • This unit majorly consists of • Video decoder • Video scalar • DSP processor • Video processor&lt;br /&gt;14. Retinal implant • Electrode implantation is one of the most critical jobs in this artificial vision system • The first step done in this electrode implantation is perforating a platinum foil with each hole having a diameter of 3mm • 68 flat platinum electrodes of 1mm diameter are pierced through the holes into the nucleus of neurons of the occipital lobe&lt;br /&gt;15. Continued……. • Each electrode is connected by separate Teflon insulated wire to a connector contained in the pedestal • The group of wires pass the electrical impulses which are generated by the processor • When the electrode is stimulated by the processor by sending an electrical impulse, the electrode produces closely spaced phosphene (light spots seen by visual field) • By sending the electrical impulses in different combinations and permutations the phosphene can be created in a regular fashion describing the image&lt;br /&gt;16. Video Camera Video processing unit Receiver Retinal ImplantNeuronsBrains&lt;br /&gt;17. Normal vision- Begins when light enters and strike on photoreceptor cells. These cells convert light to electric impulses that are sent to brain via optic nerves. Artificial vision- The camera captures images and sends to retina implant. It stimulates neurons. The stimulated neurons send information to brain via optic nerves.&lt;br /&gt;18. When is it used? • The Argus II Retinal Prosthesis System is intended for patients aged 25 years • and older with bare or no light perception vision caused by advanced retinitis pigmentosa.&lt;br /&gt;19. RESULTS OF THIS SYTEM • identify the location or movement of objects and people; • recognize large letters, words, or Sentences. • and helped in other activities of daily life, such as detecting street curbs and walking on a sidewalk without stepping off.&lt;br /&gt;20. Support for Argus ii device… • Three government organizations provided support for the development of the Argus II. The Department of Energy, National Eye Institute at the National Institutes of Health and the National Science Foundation collaborated to provide grant funding totaling more than $100 million, support for material design and other basic research for the project.&lt;br /&gt;21. Another approach to Artificial vision&lt;br /&gt;22. Advantages • ability to perform visual tasks demonstrated in many patients • Upgradable external hardware and software to benefit from future innovations • the brain has an amazing ability to adapt to new input and to improve his or her understanding of what is being “seen” via an artificial vision system.&lt;br /&gt;23. Disadvantages • The cost of device is too high( $1500) • It is difficult to acquire this technology by common man.&lt;br /&gt;24. •Using ULSI technologies, the device can be further reduced in size&lt;br /&gt;25. CONCLUSION&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/5805308916255206508/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-for-blind.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5805308916255206508'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5805308916255206508'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-for-blind.html' title='Artificial Eye For The Blind'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-4319109977070340934</id><published>2020-04-28T20:36:00.004+05:30</published><updated>2020-04-28T20:36:39.799+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Artificial eye advantages and disadvantages"/><title type='text'> Artificial eye (Prosthetic Eye) advantages and disadvantages</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
Prosthetic eye can’t re-establish vision. After the evacuation of the natural eye and position of a prosthetic eye, a man will have no vision in that eye. Here are some advantages that you might from the prosthetic eyes.&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Apposite Facial Function&lt;/h4&gt;
One more favorable benefit of a prosthetic eye is that it gives our body a chance to work. For example, after losing an eye if an artificial eye is not immediately settled, the eye socket might begin shutting, and the eyelid should get drained and quit working properly.&lt;br /&gt;Getting an artificial eye settled set up gives the eye socket a chance to keep hold of its great shape and size. Besides, it additionally gives the eyelid the opportunity to work precisely.&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Improving Physical Appearance&lt;/h4&gt;
Individuals who are feeling the loss of an eye or both don’t feel good continually wearing a bandage. There are very few alternatives for people with this handicap unless they pick a prosthetic eye.&lt;br /&gt;Luckily, people may have prosthetic eyes hand -crafted by an ocularist that has some expertise in making artificial eyes. Prosthetic eyes are made out of acrylic. During the time spent in making the artificial eye, the iris is hand-painted and made as per the eye of the new owner.&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Working up a Better Personality&lt;/h4&gt;
A few people choose to have an artificial eye to show signs of improving their identity and to be resembling whatever is left of the world. It is not agreeable for many people to demonstrate their inability in the general population, given the look and inconsiderate questions stranger ask to them.&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Boosting up Confidence&lt;/h4&gt;
Having a prosthetic eye that shows up precisely like the other eye indeed builds a person’s confidence since they at no time in the future seem to have an inability. The artificial eyes help to boost up the confidence of the people who don’t have an eye.&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
A Beautiful Facial Look&lt;/h4&gt;
The prosthetic eyes, give a person much beautiful look. It increases the attractiveness of the face.&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Toppics&amp;nbsp; related to artificial eye advantages and disadvantages&lt;/h4&gt;
artificial eye report pdf&lt;br /&gt;uses of artificial eye&lt;br /&gt;prosthetic eye care&lt;br /&gt;prosthetic eye movement&lt;br /&gt;best prosthetic eye doctor&lt;br /&gt;custom prosthetic eyes&lt;br /&gt;fake eye&lt;br /&gt;can you sleep with a prosthetic eye&lt;br /&gt;artificial eye fitting&lt;br /&gt;how are glass eyes made&lt;br /&gt;prosthetic eye bleeding&lt;br /&gt;how to make artificial eye&lt;br /&gt;Can artificial eyes made?&lt;br /&gt;What does a fake eye look like?&lt;br /&gt;How do you take care of an artificial eye?&lt;br /&gt;What are artificial eyes made of?&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/4319109977070340934/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-prosthetic-eye.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/4319109977070340934'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/4319109977070340934'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-prosthetic-eye.html' title=' Artificial eye (Prosthetic Eye) advantages and disadvantages'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-1709511539961947087</id><published>2020-04-22T20:41:00.003+05:30</published><updated>2020-04-22T20:41:37.909+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Contracted eye socket reconstruction"/><title type='text'>Contracted eye socket reconstruction</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;iframe allowfullscreen=&quot;&quot; frameborder=&quot;0&quot; height=&quot;485&quot; marginheight=&quot;0&quot; marginwidth=&quot;0&quot; scrolling=&quot;no&quot; src=&quot;//www.slideshare.net/slideshow/embed_code/key/L6b2iGKZreJcJW&quot; style=&quot;border-width: 1px; border: 1px solid #ccc; margin-bottom: 5px; max-width: 100%;&quot; width=&quot;595&quot;&gt; &lt;/iframe&gt; &lt;br /&gt;
&lt;div style=&quot;margin-bottom: 5px;&quot;&gt;
&lt;b&gt; &lt;a href=&quot;https://www.slideshare.net/MohammedAljodah/contracted-eye-socket-reconstruction&quot; target=&quot;_blank&quot; title=&quot;Contracted eye socket reconstruction&quot;&gt;Contracted eye socket reconstruction&lt;/a&gt; &lt;/b&gt; from &lt;b&gt;&lt;a href=&quot;https://www.slideshare.net/MohammedAljodah&quot; target=&quot;_blank&quot;&gt;Mohammed Aljodah&lt;/a&gt;&lt;/b&gt; &lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
1. CONTRACTED EYE SOCKET RECONSTRUCTION&lt;br /&gt;
2. Questions to be answered • What is the eye socket? • What is the common causes for enucleation? • What is the contracture of socket? • What cause that? • how to prevent it? • Aims of surgery? • Types of surgery? • Types of implant?&lt;br /&gt;
3. • Enucleation is the removal of the eye that leaves the eye muscles and remaining orbital contents intact. • Exenteration – removal of the contents of the eye socket, including the eyeball, fat, muscles, and other adjacent structures of the eye.&lt;br /&gt;
4. • Tenon&#39;s capsule thin membrane which envelops the eyeball from the optic nerve to the limbus, separating it from the orbital fat and forming a socket in which it moves, In front it adheres to the conjunctiva. • After enucleation orbital implant iserted to the Tenon&#39;s capsule in order to keep the orbital size and to keep eye animation .&lt;br /&gt;
5. The term Eye socket is refer to: • Eyelids • Conjunctival fornices • Orbital structures(bony cavity and soft tissues)&lt;br /&gt;
6. Common causes requiring socket reconstruction • Congenital (anophthalmia ,microphthalmia) • Trauma • Tumour • scarring&lt;br /&gt;
7. contracture of socket It refer to : • extensive loss of conjunctiva surface area • deep scar formation • shrinkage of orbital fat • conjunctiva fornices contracture.&lt;br /&gt;
8. Causes of contracture of socket • irradiation of the socket as after enucleation in some cases of retinoblastoma. • severe socket infections. • faulty or non wearing of the artificial eye. • keloid like mass formation in the socket. • tissue loss due to injury. • scarring of the conjunctiva due to various factors(allergy for ex.)&lt;br /&gt;
9. Main compliants The main presenting complaint : • story of a gradually increasing difficulty in retaining the prostheses. • the patients are not satisfied with the cosmetic appearance.&lt;br /&gt;
10. Preoperative assessment the contracted sockets should be examined clinically and microbiologically. History :In every case, mode, circumstances and duration of the eye loss, and subsequent problems with the prostheses . The socket should be examined for fibrous bands, condition of the various fornices and the state of the conjunctiva.&lt;br /&gt;
11. • Never forget to Assess the prosthesis shape and size . • Look for orbital implant exposure.&lt;br /&gt;
12. Grades of contracted sockets. • The soft tissue sockets were divided into five grades for the sake of convenience in management of contracted sockets. Grade-0: Socket is lined with the healthy conjunctiva and has deep and well formed fornices. Grade-I: Socket is characterized by the shallow lower fornix or shelving of the lower fornix. Here the lower fornix is converted into a downwards sloping shelf which pushes the lower lid down and out, preventing retention of a artificial eye&lt;br /&gt;
13. • Frequently there is shallow lower fornix and deep upper fornix resulting in upward migration of the prosthesis.&lt;br /&gt;
14. Grade-II: Socket is characterized by the loss of the upper and lower fornices&lt;br /&gt;
15. Grade- III: Socket is characterized by the loss of the upper, lower, medial and lateral fornices&lt;br /&gt;
16. Grade-IV: Socket is characterized by the loss of all the fornices, and reduction of palpebral aperture in horizontal and vertical dimensions&lt;br /&gt;
17. Grade-V: In some cases, there is recur- rence of contracture of the socket after repeated trial of reconstruction&lt;br /&gt;
18. Aims of reconstruction • To establish stable fornices by increasing the surface area by (hard palate ,oral mucosal,skin graft) and if necessary by increasing size by orbital implant. • The ocular prostheses should be light and take its support from infraorbital rim not from the lids.&lt;br /&gt;
19. Prevention • By use of conformer made by ocularist placed inside orbit to help support the growth of eye socket and bones in the face. • the conformer used during healing for about 6 weeks then ocular shell prosthesis used there after.&lt;br /&gt;
20. Types of ocular prosthesis • Spherical or oval • Stock or custom made • Porous or non porous • Chemical make up • Presence or absence of motility post.&lt;br /&gt;
21. Surgical principle • First : obtain adequate palpepral aperture size (canthoplasty may be needed in grade3,4,5) • Second : create adequate fornixes (lower,upper,lateral) insicion central in grade 2 while it can be at inferior position in grade 1. • Third : perfect lining of the created fornix (hard palate ,oral mucosal,skin graft ,amniotic membrane) • Fourth be sure that the fornix created supported by orbital bony rim to create a stable and deep lower fornix, the lower edge of the graft should be sutured to the inferior orbital bone rim using anchor sutures .&lt;br /&gt;
22. • Fifth: the conformer used during healing for about 6 weeks then ocular shell prosthesis used there after. • Sixth : central temporary tarsorrhaphy may be used.&lt;br /&gt;
23. Orbital implant exposure • One of the most important aspect of eye socket reconstruction can present with or without socket contracture.&lt;br /&gt;
24. Orbital implant exposure&lt;br /&gt;
25. • Autogenous Derma-Fat Graft used usally in case of Exenteration and in cases of extrusion or implant exposure.&lt;br /&gt;
26. The extraocular muscles and conjunctiva is sutured into the border of the DFG&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/1709511539961947087/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/contracted-eye-socket-reconstruction.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/1709511539961947087'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/1709511539961947087'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/contracted-eye-socket-reconstruction.html' title='Contracted eye socket reconstruction'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-5679635771624023114</id><published>2020-04-21T23:43:00.001+05:30</published><updated>2020-04-21T23:43:51.705+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Artificial eye advantages and disadvantages"/><title type='text'>Artificial eye advantages and disadvantages</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;An artificial eye is a replacement for a natural eye lost because of injury or disease. ... This material had the advantage of being unbreakable as well as malleable. ... Called stock eyes, they have the disadvantage of not being properly fitted&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Topics Related&amp;nbsp; to artificial eye advantages and disadvantages&lt;/h4&gt;
&lt;ul style=&quot;text-align: left;&quot;&gt;
&lt;li&gt;artificial eye report pdf&lt;/li&gt;
&lt;li&gt;prosthetic eye care&lt;/li&gt;
&lt;li&gt;uses of artificial eye&lt;/li&gt;
&lt;li&gt;prosthetic eye movement&lt;/li&gt;
&lt;li&gt;best prosthetic eye doctor&lt;/li&gt;
&lt;li&gt;fake eye&lt;/li&gt;
&lt;li&gt;custom prosthetic eyes&lt;/li&gt;
&lt;li&gt;can you sleep with a prosthetic eye&lt;/li&gt;
&lt;li&gt;How long does a prosthetic eye last?&lt;/li&gt;
&lt;li&gt;Can artificial eyes made?&lt;/li&gt;
&lt;li&gt;How does an artificial eye work?&lt;/li&gt;
&lt;li&gt;How do you take care of an artificial eye?&lt;/li&gt;
&lt;/ul&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/5679635771624023114/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-advantages-and.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5679635771624023114'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5679635771624023114'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-advantages-and.html' title='Artificial eye advantages and disadvantages'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-8505164355807606141</id><published>2020-04-18T20:26:00.001+05:30</published><updated>2020-04-18T20:26:10.303+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="ORBITAL IMPLANTS"/><title type='text'>Orbital implant</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;iframe allowfullscreen=&quot;&quot; frameborder=&quot;0&quot; height=&quot;485&quot; marginheight=&quot;0&quot; marginwidth=&quot;0&quot; scrolling=&quot;no&quot; src=&quot;//www.slideshare.net/slideshow/embed_code/key/E6K14VrbfANubb&quot; style=&quot;border-width: 1px; border: 1px solid #ccc; margin-bottom: 5px; max-width: 100%;&quot; width=&quot;595&quot;&gt; &lt;/iframe&gt; &lt;br /&gt;
&lt;div style=&quot;margin-bottom: 5px;&quot;&gt;
&lt;b&gt; &lt;a href=&quot;https://www.slideshare.net/samialbdairat/orbital-implants&quot; target=&quot;_blank&quot; title=&quot;Orbital implants&quot;&gt;Orbital implants&lt;/a&gt; &lt;/b&gt; from &lt;b&gt;&lt;a href=&quot;https://www.slideshare.net/samialbdairat&quot; target=&quot;_blank&quot;&gt;samialbdairat&lt;/a&gt;&lt;/b&gt; &lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Orbital implants&lt;br /&gt;
1. SAMI AL-BDAIRAT, MD ORBITAL IMPLANTS&lt;br /&gt;
2. ANOPHTHALMIA • Anophthalmia is absence of globe • Congenital or acquired&lt;br /&gt;
3. ACQUIRED ANOPHTHALMOS • After enucleation/evisceration/exenteration&lt;br /&gt;
4. enucleation, evisceration, or secondary implantation surgery Conformer is placed in the conjunctival fornices to maintain the conjunctival space conformer is replaced with a custom-made ocular prosthesis typically fashioned 4–6 weeks&lt;br /&gt;
5. ANOPHTHALMIC SURGERY • Successful anophthalmic surgery is achieved when the anophthalmic patient obtains a painless, non-inflamed eye socket with adequate volume restoration and an artificial eye that looks and moves almost as naturally as a normal eye. • The optimal time to achieve the best functional and cosmetic result for the anophthalmic patient is at the time of enucleation&lt;br /&gt;
6. • orbital implant is typically placed at the time of evisceration or enucleation • ocular prosthesis is fitted subsequently.&lt;br /&gt;
7. DISPOSABLE SIZING KIT&lt;br /&gt;
8. ORBITAL SPHERE INTRODUCER Stainless Steel&lt;br /&gt;
9. CONFORMERS Translucent, Polyamide 12 Small 20mm Medium 23mm Large 26mm&lt;br /&gt;
10. • Anophthalmic implant: Material or substance used to replace an enucleated or eviscerated globe (e.g. polymethylmethacrylate, silicone,hydroxyapatite, aluminum oxide, porous polyethylene, etc.) • Porous implant: Refers to an implant with numerous interconnected pores or channels throughout its structure that permit fibrovascular ingrowth (e.g. hydroxyapatite, aluminum oxide, porous polyethylene) • Nonporous implant: Refers to an implant that is solid and does not allow fibrovascular ingrowth (e.g. polymethylmethacrylate, silicone)&lt;br /&gt;
11. • Buried implant: an implant that has been placed within the anophthalmic socket with an overlying closed, smooth, uninterrupted conjunctival surface completely covering the anophthalmic implant • Exposed implant: an implant that does not have an overlying closed, smooth, uninterrupted surface completely covering it. An exposed implant is an unwanted complication postoperatively with any implant&lt;br /&gt;
12. • Integrated implant: an implant that can be directly coupled to the overlying prosthetic eye with a peg system. As there is a small break in the overlying conjunctiva through which the peg protrudes, there is some debate whether this type of implant should also be known as a partially “exposed integrated implant • Non-integrated implant An implant that has been placed within the anophthalmic socket that has no connection with the overlying prosthetic eye. There is a closed, smooth, uninterrupted conjunctival surface completely covering the anophthalmic implant. Also known as a “buried non-integrated implant”&lt;br /&gt;
13. Peg: A motility coupling post, made of titanium, which permits direct coupling of the implant movement to an overlying prosthesis. Pegs may be inserted within sleeves that are drilled into the anterior aspect of the implant.&lt;br /&gt;
14. QUASI-INTEGRATED IMPLANT • An implant that has been placed within the anophthalmic socket with a closed, uninterrupted conjunctival surface completely covering an anophthalmic implant that has an irregular anterior surface, allowing indirect coupling (“quasi-integration”) of implant to overlying, modified prosthesis (e.g., Allen, Iowa, Universal, MEDPOR Quad implants). Also known as a “buried integrated implant” or an “indirectly integrated implant.” Recently designed magnetic coupling systems may also be classified as quasi- integrated .&lt;br /&gt;
15. ADVANTAGES OF EVISCERATION OVER ENUCLEATION • Less disruption of orbital anatomy. • Good motility of prosthesis • Lower rate of migration ,extrusion , reoperation.&lt;br /&gt;
16. HISTORY • As early as 500 B.C., Egyptians and Romans wore ocular prostheses (made of clay) designed by pagan priests. • Johannes Lange in 1555 (Lowenberg, Germany) was the first to mention enucleation (or extirpation as it was called then), no details of the operative procedure were given • George Bartisch, in 1583 the first recorded description of removal of an eye for treatment of severe ocular disease(Extirpation)&lt;br /&gt;
17. EXTIRPATION METHOD OF BARTISCH&lt;br /&gt;
18. HISTORY • Ambroise Pare in 1579 described the first prosthesis which was made of metal and coated with paint . • In 1841 current enucleation technique was established in separate reports (only weeks apart) by O’Ferrall (Dublin) and Bonnet (Paris) • The first recorded evisceration is credited to James Bear in 1817. • The first to perform a routine evisceration procedure was Noyes who, in 1874&lt;br /&gt;
19. HISTORY • In 1884, P.H. Mules developed a unique technique for evisceration, which has proved to be a milestone in ophthalmic surgery. He was the first to insert a hollow glass sphere (the “Mules” sphere) into the scleral cavity after removal of the cornea and intraocular contents • Since then Sponge, rubber, paraffin, ivory, wool, cork, cartilage, fat, bone, Vitallium, platinum, aluminum, silver, and gold were used as implant. • By the 1950s, A variety of implant designs were tried with an attempt to indirectly couple the buried implant to an overlying artificial eye by modifying the anterior surface of the implant as well as the posterior surface of the prosthesis. The Allen and subsequently the Iowa enucleation implants were buried integrated ( “quasi- integrated”) implants.&lt;br /&gt;
20. HISTORY • Troutman, Uribe, Iliff, magnetic implants – 1950s and 1960s), • Universal implant (1987) • By 1989, spherical implants made of silicone, glass, or polymethylmethacrylate (PMMA) were the implants most widely used by ophthalmic plastic surgeons • The introduction of coralline hydroxyapatite orbital implants in the mid- to late 1980s in enucleation, evisceration, or secondary orbital implant surgery ushered in a new era in anophthalmic socket reconstruction. • Several other porous implant materials have since been introduced as alternatives (e.g. synthetic hydroxyapatite, porous polyethylene, aluminum oxide).&lt;br /&gt;
21. IDEAL ANOPHTHALMIC SOCKET 1.A centrally placed, well-covered, buried implant of adequate volume, fabricated from a bio-inert material 2. A socket lined with healthy conjunctiva and fornices deep enough to retain a prosthesis and to permit horizontal and vertical excursion of an artificial eye 3. Eyelids with normal position and appearance, as well as adequate tone to support a prosthesis 4. A supratarsal eyelid fold that is symmetric with the supratarsal fold of the contralateral eyelid 5. Normal position of the eyelashes and eyelid margin 6. Good transmission of motility from the implant to the overlying prosthesis 7. A comfortable ocular prosthesis that looks similar to the sighted, contralateral globe and in the same horizontal plane&lt;br /&gt;
22. IDEAL ORBITAL IMPLANT • Maintain Natural Lid Shape : ability to receive a motility/support peg, to support the weight of the artificial eye to prevent lower lid laxity and malposition over time . • Light Weight • Porosity: The implant must allow vascular orbital tissues to invade its structure to: a) lock it into place and prevent migration, b) allow it to fight infections from within the implant via the vascular bed infiltrating the implant, and c) support &quot;healing from within&quot; of any defect in the conjunctival-Tenon&#39;s closure • True Integration The implant must be directly integrated (e.g., via a peg) with the artificial eye to allow direct transfer of all available movement from the rectus muscles to the artificial eye • Natural Biocompatibility: the implant must be a natural material and readily accepted by the tissues of the orbit to prevent &quot;synthetic implant syndrome&quot; i.e., pseudocapsule formation around the implant. This pseudocapsule is the body&#39;s way of walling off a foreign material • Non toxic non allergic&lt;br /&gt;
23. CURRENT CLASSIFICATION OF IMPLANTS • porous or nonporous, and in either category, the implants are non-integrated, integrated, or quasi- integrated • Porous implants (hydroxyapatite, porous polyethylene, aluminum oxide) • nonporous implants (silicone,polymethylmethacrylate) • Quasi integrated (or indirectly integrated) implants may be porous or nonporous and, because of their irregular anterior surface, are partially coupled to the overlying prosthetic eye (e.g., Allen, Iowa, Universal, MEDPOR ® Quad implant).&lt;br /&gt;
24. • non porous Inert spherical implants • Acrylic sphere • is the most basic implant. • Acrylic, or methylmethacrylate, • non-porous material • is best used in cases of trauma, such as a severe gunshot wound to the orbit • silicone sphere. This non-porous implant is similar to an acrylic implant, but slightly more pliable.&lt;br /&gt;
25. NON POROUS INERT SPHERICAL IMPLANTS Advantages • Provide comfort and low rates of extrusion. • Cost-effective choice in patients. Disadvantages • decreased motility and implant migration.&lt;br /&gt;
26. POROUS ORBITAL IMPLANTS hydroxyapatite • Perry (1985) introduced coralline (sea coral)(HA) spheres • complex calcium phosphate • regular and complete system of interconnecting pores ( 500- µm pore size ) • secure attachment of the extra ocular muscles • The most suitable for peg–sleeve system. •&lt;br /&gt;
27. hydroxyapatite Disadvantages: surface is abrasive Conjonctival thining extrusion or exposure infection. pyogenic granuloma formation, Costy Synthetic HA implants developed by FCI Chinese HA Brazilian HA Less expensive Poor porous structure&lt;br /&gt;
28. SYNTHETIC POROUS POLYETHYLENE (MEDPOR) • a porous type of plastic • Less biocompatible than HA • Well tolerated by orbital soft tissue • The surface is nonabrasive so extrusion is rare. They may be used with or without a wrapping material • extra ocular muscles can be sutured directly onto the implant&lt;br /&gt;
29. SYNTHETIC POROUS POLYETHYLENE (MEDPOR) • available in spherical, egg, conical, and mounded shapes (MEDPOR ® Quad implant) • The anterior surface can also be manufactured with a smooth, nonporous surface to prevent abrasion of the overlying tissue (e.g., MEDPOR ® smooth surface tunnel implant – SST™.&lt;br /&gt;
30. ALUMINUM OXIDE (AL 2 O 3, ALUMINA, BIOCERAMIC IMPLANT • porous, inert substance • permit host fibrovascular ingrowth • Human fibroblasts and osteoblasts proliferate more rapidly on aluminum oxide than HA suggesting it is a more biocompatible substance than HA • lightweight and has a uniform pore structure and excellent pore interconnectivity • The microcrystalline structure is smoother than the rough surfaced Bio-Eye • A protein coating that forms after insertion prevents the implant from being recognized as a foreign body This inert nature of these implants is a potentially critical advantage in minimizing socket inflammation. • Less expensive&lt;br /&gt;
31. VARIETY OF SHAPES Mesh-Wrapped Egg-Shaped Spherical&lt;br /&gt;
32. ADVANTAGES OF VICRYL MESH WRAP  Facilitates entry into the orbit by decreasing drag on surrounding structures  Allows suturing directly to implant  Eliminates need for donor tissue  No risk of disease transmission  Eliminates second surgical site  Absorbable  Allows 360 degree entry of fibrovascular tissue (as opposed to entry through scleral windows)&lt;br /&gt;
33. PEGGING • Is an option of any of the porous implants, most commonly done with hydroxyapatite. • The thought behind pegging is that it improves motility by allowing the pegged surface to fit into a corresponding groove in the back of the prosthesis . • can promote infection and lead to extrusion&lt;br /&gt;
34. DERMIS FAT GRAFT&lt;br /&gt;
35. ORBITAL IMPLANT SELECTION IN ADULTS • spherical versus shaped implants, wrapped versus unwrapped implants, and pegged versus unpegged implants. • In a 2004 survey of orbital surgeons, of 1,919 primary orbital implants used following enucleation, porous polyethylene was used in 42.7% of cases followed bycoralline HA (27.3%), nonporous alloplastic (PMMA, silicone) implants (19.9%), dermis-fat grafts (7.2%), Bioceramic (1.8%), synthetic HA (0.9%), and mammalian bone (0.2%)&lt;br /&gt;
36. ORBITAL IMPLANT SELECTION IN ADULTS • porous implant between the ages of 15 and 65 years old • quasi-integrated implant such as the Universal (PMMA – mounded) or MEDPOR ® Quad implant (mounded) • A nonporous sphere (e.g., PMMA, silicone), wrapped, centered within the muscle cone, and attached to each of the rectus muscles and inferior oblique muscle, • A nonporous implant simply placed into the orbit, without a wrap and without connection to the rectus muscles ……seventh decade or beyond),&lt;br /&gt;
37. ORBITAL IMPLANT SELECTION IN CHILDREN • less than 5 years age …..wrapped nonporous sphere implant 16- or 18-mm diameter Exchange with porous and bigger size is possible….autogenous dermis-fat grafts. • 5 to 15 years age ,nonporous implants, either a PMMA mounded implant (e.g. Universal) or a wrapped sphere (e.g. PMMA, silicone).&lt;br /&gt;
38. EXPOSURE AND EXTRUSION OF IMPLANT predisposing Factors  1. closing the wound under tension 2. poor wound closure techniques 3. Infection 4. mechanical or inflammatory irritation from the speculated surface of the porous implant 5. Delayed ingrowth of fibrovascular tissue with subsequent tissue breakdown&lt;br /&gt;
39. Preventive measures for implant exposure • proper placement of the implant within the orbit followed by a two-layered closure of anterior Tenon’s capsule and conjunctiva • Treatment : If few weeks, • No infection ,simple reclosure or with a patch graft (e.G., Sclera, temporalis fascia) is required • If infection is suspected and treated vigorously with topical and systemic antibiotics, an extrusion and removal of the implant may be avoided.&lt;br /&gt;
40. beyond 4–6 months, • If non porous implant, The defect should not be closed, and secondary orbital implant surgery should be arranged • If porous, exposure &amp;lt;3mm &amp;gt;3mm Treat conservatively Wait 8 weeks for spontaneous closure no Close with scleral patch graft surgical repair is indicated Using sclera patch graft or temporalis fascia patch graft&lt;br /&gt;
41. SUMMARY • Ophthalmic surgeons working closely with qualified ocularists must be focused on restoring a patient’s natural eye appearance with prosthetic motility as near normal as possible. • We currently prefer implantation of a porous implants, with or without polyglactin 910 mesh wrapp with attachment of all rectus muscles and inferior oblique to the covered implant. • Pegging may not be appropriate for all implant surgeons or anophthalmic patients. • We hope in the future….&lt;br /&gt;
42. THANK YOU&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/8505164355807606141/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/orbital-implant.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/8505164355807606141'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/8505164355807606141'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/orbital-implant.html' title='Orbital implant'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-3578294538771167245</id><published>2020-04-18T20:22:00.004+05:30</published><updated>2020-04-18T20:22:53.526+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="ORBITAL IMPLANTS"/><title type='text'> ORBITAL IMPLANTS</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;iframe allowfullscreen=&quot;&quot; frameborder=&quot;0&quot; height=&quot;485&quot; marginheight=&quot;0&quot; marginwidth=&quot;0&quot; scrolling=&quot;no&quot; src=&quot;//www.slideshare.net/slideshow/embed_code/key/3aMBlpo5tKsMpE&quot; style=&quot;border-width: 1px; border: 1px solid #ccc; margin-bottom: 5px; max-width: 100%;&quot; width=&quot;595&quot;&gt; &lt;/iframe&gt; &lt;br /&gt;
&lt;div style=&quot;margin-bottom: 5px;&quot;&gt;
&lt;b&gt; &lt;a href=&quot;https://www.slideshare.net/ReshmaPeter3/orbital-implants-77758093&quot; target=&quot;_blank&quot; title=&quot;Orbital implants&quot;&gt;Orbital implants&lt;/a&gt; &lt;/b&gt; from &lt;b&gt;&lt;a href=&quot;https://www.slideshare.net/ReshmaPeter3&quot; target=&quot;_blank&quot;&gt;Reshma Peter&lt;/a&gt;&lt;/b&gt; &lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
1. ORBITAL IMPLANTS DR. RESHMA PETER&lt;br /&gt;
2.  Anophthalmia-Absence of globe  Defined as an orbit not containing an eye ball, but has orbital soft tissues  usually acquired, rarely congenital  The most common cause - enucleation of the globe&lt;br /&gt;
3. SURGICAL PROCEDURES IN THE REMOVAL OF AN EYE Classified into three categories Evisceration- Removal of the contents of the globe leaves the sclera ,fat,EOM, and other adjacent structures of the eye intact and sometimes the cornea in place. Enucleation- Removal of the eye leaves EOM and remaining orbital contents intact. Exenteration Removal of the entire contents of the orbit including EOM&lt;br /&gt;
4. Tenon&#39;s capsule-  Thin membrane which envelops the eyeball from the optic nerve to the limbus  Separates eyeball from the orbital fat  Forms a socket in which it moves  In front it adheres to the conjunctiva. After enucleation orbital implant inserted to the Tenon&#39;s capsule in order  to keep the orbital size  to keep eye animation&lt;br /&gt;
5. Eye socket Eyelids Conjunctival fornices Orbital structures(bony cavity and soft tissues)&lt;br /&gt;
6. Common causes requiring socket reconstruction  Congenital (anophthalmia ,microphthalmia)  Trauma  Tumour  scarring&lt;br /&gt;
7. Acquired anophthalmos After enucleation/evisceration/exenteration&lt;br /&gt;
8. Ideal anophthalmic socket 1.A centrally placed, well-covered, buried implant of adequate volume, fabricated from a bio-inert material 2. A socket lined with healthy conjunctiva and fornices deep enough to retain a prosthesis and to permit horizontal and vertical movements of an artificial eye 3. Eyelids with normal position ,appearance and adequate tone to support a prosthesis 4. A supratarsal eyelid fold that is symmetric with that of the C/l eyelid&lt;br /&gt;
9. 5. Normal position of the eyelashes and eyelid margin 6. Good transmission of motility from the implant to the overlying prosthesis 7. A comfortable ocular prosthesis that looks similar to the sighted, contralateral globe and in the same horizontal plane&lt;br /&gt;
10. Enucleation/evisceration secondary implantation surgery Conformer is placed in the conjunctival fornices to maintain the conjunctival space conformer is replaced with a custom-made ocular prosthesis typically fashioned 4–6 weeks ORBITAL IMPLANT CONFORMER OCULAR PROSTHESIS&lt;br /&gt;
11. Orbital implant typically placed at the time of evisceration or enucleation Ocular prosthesis fitted subsequently&lt;br /&gt;
12. Anophthalmic surgery Successful anophthalmic surgery is achieved when the anophthalmic patient obtains  a painless, non-inflamed eye socket  with adequate volume restoration  an artificial eye that looks and moves almost as naturally as a normal eye The optimal time to achieve the best functional and cosmetic result for the anophthalmic patient is at the time of enucleation&lt;br /&gt;
13. Most socket reconstructive surgeries are required to address the following problems: 1. A volume deﬁcit following loss of the globe 2. Contracture of the socket 3. Orbital implant exposure, extrusion, and malposition&lt;br /&gt;
14. History  500 B.C.:Egyptians and Romans wore ocular prostheses  1555 :Johannes Lange (Lowenberg, Germany) 1st to mention enucleation (or extirpation as it was called then)  1583 :George Bartisch 1st recorded description of removal of an eye for treatment of severe ocular disease (Extirpation)&lt;br /&gt;
15. • 1579 :Ambroise Pare described the 1st prosthesis which was made of metal and coated with paint . • 1841: O’Ferrall (Dublin) and Bonnet (Paris) established current enucleation technique • 1817 :1st recorded evisceration by James Bear • 1874: Noyes -1st to perform a routine evisceration procedure •&lt;br /&gt;
16.  1884: P.H. Mules developed a unique technique for evisceration  a milestone in ophthalmic surgery  He inserted a hollow glass sphere (the “Mules” sphere) into the scleral cavity after removal of the cornea and intraocular contents Since then Sponge, rubber, paraffin, ivory, wool, cork, cartilage, fat, bone, Vitallium, platinum, aluminum, silver, and gold were used as implant.&lt;br /&gt;
17. 1886:Frost 1st described the placement of an orbital implant into an enucleated socket 1820s-1890s :Enamel prostheses introduced ;expensive and not durable.  1835 :Germans introduced cryolite glass  made of arsenic oxide and cryolite from NaAlF  grayish-white color suitable for a prosthetic eye  a tube of glass was heated on one end until the form of a ball obtained.  Various colors of glass used to imitate the natural eye color&lt;br /&gt;
18. • 19th century:German craftsmen (&quot;ocularists&quot;) began to tour the US and other parts of the world, fabricated eyes and fit them to patients • Stock eyes (or pre-made eyes) were also utilized. An &quot;eye doctor&quot; might keep hundreds of glass stock eyes in cabinets, and would fit patients with the best eye right out of the drawer.&lt;br /&gt;
19.  After the onset of WW II, when German glass blowers no longer toured US,the US and practitioners developed prostheses using oil pigments and plastics. •1940 :Naval dental school used acrylic resin in fabricating a custom ocular prosthesis. The acrylic eye was •easy to fit and adjust •Unbreakable • inert to ocular fluids •aesthetical good •longer lasting •easier to fabricate&lt;br /&gt;
20. • 1950s:A variety of implant designs were tried with an attempt to indirectly couple the implant to an overlying artificial eye by modifying the anterior surface of the implant as as the posterior surface of the prosthesis. • The Allen and subsequently the Iowa enucleation implants were buried integrated ( integrated”) implants.&lt;br /&gt;
21.  1950s and 1960s :Troutman, Uribe, Iliff - magnetic implants  1987 :Universal implant  1989:spherical implants made of silicone, glass, or polymethylmethacrylate (PMMA)  mid- to late 1980s The introduction of coralline hydroxyapatite orbital implants in enucleation, evisceration, or secondary orbital implant surgery  Several other porous implant materials have since been introduced as alternatives (e.g. synthetic hydroxyapatite, porous polyethylene, aluminum oxide).&lt;br /&gt;
22.  Anophthalmic implant: Material or substance used to replace an enucleated or eviscerated globe (e.g. polymethylmethacrylate, silicone,hydroxyapatite, aluminum oxide, porous polyethylene, etc.)  Porous implant: Refers to an implant with numerous interconnected pores or channels throughout its structure that permit fibrovascular ingrowth (e.g. hydroxyapatite, aluminum oxide, porous polyethylene)  Nonporous implant: Refers to an implant that is solid and does not allow fibrovascular ingrowth (e.g. polymethylmethacrylate, silicone)&lt;br /&gt;
23.  Buried implant: an implant that has been placed within the anophthalmic socket with an overlying closed, smooth, uninterrupted conjunctival surface completely covering the anophthalmic implant  Exposed implant: an implant that does not have an overlying closed, smooth, uninterrupted surface completely covering it. An exposed implant is an unwanted complication postoperatively with any implant&lt;br /&gt;
24.  Integrated implant: an implant that can be directly coupled to the overlying prosthetic eye with a peg system. As there is a small break in the overlying conjunctiva through which the peg protrudes, Sometimes known as a partially exposed integrated implant  Non-integrated implant An implant that has been placed within the anophthalmic socket that has no connection with the overlying prosthetic eye. There is a closed, smooth, uninterrupted conjunctival surface completely covering the anophthalmic implant. Also known as a “buried non-integrated implant”&lt;br /&gt;
25. Peg: A motility coupling post, made of titanium, which permits direct coupling of the implant movement to an overlying prosthesis. Pegs may be inserted within sleeves that are drilled into the anterior aspect of the implant.&lt;br /&gt;
26. Quasi-integrated implant (buried integrated implant OR indirectly integrated implant) An implant that has been placed within the anophthalmic socket with a closed, uninterrupted conjunctival surface completely covering an anophthalmic implant that has an irregular anterior surface, allowing indirect coupling (“quasi-integration”) of implant to overlying, modified prosthesis (e.g., Allen, Iowa, Universal, MEDPOR Quad implants). Recently designed magnetic coupling systems may also be classified as quasi-integrated .&lt;br /&gt;
27. Integrated implants  designed to improve prosthesis motility by coupling to the overlying prosthesis.  Implant is exposed through the conjunctiva  directly coupled to the prosthesis with a peg, pin, screw or other method.&lt;br /&gt;
28. Semi-integrated ocular implants • consist of an acrylic resin implant with 4 protruding mounds on the anterior surface • These acrylic resin mounds protrude against the encapsulating tissue • The ocular prosthesis is made with a counter contour to the implant on the posterior surface of the prosthesis.&lt;br /&gt;
29. Nonintegrated implant done by placing a hollow or solid acrylic resin sphere ranging from 10 to 22mm in diameter.&lt;br /&gt;
30. Ideal orbital implant  Maintain Natural Lid Shape : ability to receive a motility/support peg, to support the weight of the artificial eye to prevent lower lid laxity and malposition over time .  Light Weight  Porosity: The implant must allow vascular orbital tissues to invade its structure to: a) lock it into place and prevent migration b) allow it to fight infections from within the implant via the vascular bed infiltrating the implant c) support &quot;healing from within&quot; of any defect in the conjunctival-Tenon&#39;s closure&lt;br /&gt;
31.  True Integration The implant must be directly integrated (e.g., via a peg) with the artificial eye to allow direct transfer of all available movement from the rectus muscles to the artificial eye  Natural Biocompatibility: the implant must be a natural material and readily accepted by the tissues of the orbit to prevent &quot;synthetic implant syndrome&quot; i.e., pseudocapsule formation around the implant. This pseudocapsule is the body&#39;s way of walling off a foreign material  Non toxic  non allergic&lt;br /&gt;
32. Current Classification of Implants porous or nonporous, and in either category, the implants are non-integrated, integrated, or quasi-integrated  Porous implants (hydroxyapatite, porous polyethylene, aluminum oxide)  Nonporous implants (silicone,polymethylmethacrylate) Quasi integrated (or indirectly integrated) implants may be porous or nonporous and, because of their irregular anterior surface, are partially coupled to the overlying prosthetic eye (e.g., Allen, Iowa, Universal, MEDPOR ® Quad implant).&lt;br /&gt;
33. Acrylic sphere  Acrylic, or methylmethacrylate  is the most basic implant  best used in cases of trauma, such as a severe gunshot wound to the orbit Silicone sphere  similar to an acrylic implant but slightly more pliable. Non porous inert spherical implants&lt;br /&gt;
34. Non porous inert spherical implants Advantages  Provide comfort and low rates of extrusion.  Cost-effective choice in patients. Disadvantages  decreased motility and implant migration.&lt;br /&gt;
35. Porous Orbital Implants Hydroxyapatite  Perry (1985) introduced coralline (sea coral)(HA) spheres  complex calcium phosphate  regular and complete system of interconnecting pores ( 500-µm pore size )  secure attachment of the extra ocular muscles  The most suitable for peg–sleeve system.&lt;br /&gt;
36. Disadvantages of HA:  Surface is abrasive  conjonctival thinning  Extrusion or exposure  infection  Pyogenic granuloma formation  Costly Synthetic HA implants developed by FCI Chinese HA Brazilian HA  Less expensive  Poor porous structure&lt;br /&gt;
37. Synthetic porous polyethylene (MEDPOR)  a porous type of plastic  Less biocompatible than HA  Well tolerated by orbital soft tissue  The surface is nonabrasive so extrusion is rare.  They may be used with or without a wrapping material  extra ocular muscles can be sutured directly onto the implant&lt;br /&gt;
38.  available in spherical, egg, conical, and mounded shapes (MEDPOR ® Quad implant)  The anterior surface can also be manufactured with a smooth, nonporous surface to prevent abrasion of the overlying tissue (e.g., MEDPOR ® smooth surface tunnel implant – SST™.&lt;br /&gt;
39. Aluminum oxide (Al 2 O 3, Alumina, Bioceramic implant)  porous, inert substance  permit host fibrovascular ingrowth  Human fibroblasts and osteoblasts proliferate more rapidly on aluminum oxide than HA suggesting it is a more biocompatible substance than HA  lightweight  has a uniform pore structure and excellent pore interconnectivity  The microcrystalline structure is smoother than the rough surfaced Bio-Eye  A protein coating that forms after insertion prevents the implant from being recognized as a foreign body This inert nature of these implants is a potentially critical advantage in minimizing socket inflammation.  Less expensive&lt;br /&gt;
40. Variety of Shapes Mesh- Spherical eggshaped&lt;br /&gt;
41. Advantages of vicryl mesh wrap  Facilitates entry into the orbit by decreasing drag on surrounding structures  Allows suturing directly to implant  Eliminates need for donor tissue  No risk of disease transmission  Eliminates second surgical site  Absorbable  Allows 360 degree entry of fibrovascular tissue (as opposed to entry through scleral windows)&lt;br /&gt;
42. Non integrated Semi integrated Fully integrated Expandable implants IMPLANTS&lt;br /&gt;
43. Pegging  Is an option of any of the porous implants, most commonly done with hydroxyapatite.  It improves motility by allowing the pegged surface to fit into a corresponding groove in the back of the prosthesis .  can promote infection and lead to extrusion&lt;br /&gt;
44. Orbital Implant Selection in Adults BETWEEN 15 AND 65 YEARS OLD  porous implant -quasi-integrated implant such as the Universal (PMMA – mounded) or MEDPOR ® Quad implant (mounded)  A nonporous sphere (e.g., PMMA, silicone), wrapped, centered within the muscle cone, and attached to each of the rectus muscles and inferior oblique muscle, SEVENTH DECADE OR BEYOND  A nonporous implant simply placed into the orbit, without a wrap and without connection to the rectus muscles&lt;br /&gt;
45. Orbital Implant Selection in Children LESS THAN 5 YEARS AGE  wrapped nonporous sphere implant 16- or 18-mm diameter  Exchange with porous and bigger size is possible  autogenous dermis-fat grafts 5 TO 15 YEARS AGE  nonporous implants, either a PMMA mounded implant (e.g. Universal) or a wrapped sphere (e.g. PMMA, silicone).&lt;br /&gt;
46. The orbital defect  The ideal defect is circumscribed fully by bony orbital rim.  The eyebrow should be intact.  The soft tissue defining the defect should be thin and immobile.  The surface with in the defect may be lined with a skin graft or even a free tissue flap.  may be the result of a congential anomaly (facial cleft), trauma (gunshot wound, road traffic accident) or surgery.&lt;br /&gt;
47.  Even with the advent of microscovascular surgery and free tissue transfers, surgical reconstruction alone cannot fully restore this area.  Prosthetic rehabilitation is needed.  If the defect is more extensive, bone and softissue grafting should be considered to missing portions of the orbital rim, zygoma, or temporal or midface regions before placement.  The surgical restoration of contour can contribute to a less extensive prosthesis.&lt;br /&gt;
48. Implant Placement  Implants are commonly placed in the orbital rim most often superiorly and laterally.  Placement in the inferior rim is desirable if the shape of the defect and access permit.  This improves the stability and retention of prosthesis.  In larger defects extending beyond the orbital rim, implants can be placed in the zygoma or maxilla.  Even a single implant can help stabilize and retain a prosthesis.&lt;br /&gt;
49. Surgical Positioner  Actual placement of the implants is guided by a surgical positioner.  This is an acrylic resin prototype of the prosthesis that is used intraoperatively.  It indicates the ideal position for implant placement.  It also serves as guide for selection of the retentive mechanism and later as a time saving reference for the shape of the prosthesis.  It helps determine if preprosthetic surgery is needed before implant placement.  Most often, the lateral superior aspect of the orbital rim needs reduction to place an implant at the location and remain with in guidelines of the positioner .&lt;br /&gt;
50.  Implant angulation should be parallel to the frontal plane of the face or be inward slightly.  A protrusive angulation can interfere with positioner contour and require compromise of the ideal shape of the prosthesis.  At the same time implant should not be over-angulated inward because prosthetic access for fabrication of retentive mechanism can be hampered.  This is true especially in smaller shallow defects when a soft-tissue flap has been used to close the opening of the defect.&lt;br /&gt;
51.  At second-stage surgery, the gauze strip surgical dressing should be wrapped carefully around the abutments and under the healing caps so that close adaptation of skin to the abutment and underlying bone is achieved.&lt;br /&gt;
52. TECHNIQUE OF IMPLANT INSERTION Soil described an improved surgical method of placing the orbital implant following the enucleation of the eye  The optic nerve and its associated vessels are severed and tied close to the posterior wall of the capsule.  The implant is placed deep within the muscle cone, and buried beneath the posterior layer of Tenon’s capsule  The posterior portion of Tenon’s capsule is closed over the implant providing the first layer of closure.&lt;br /&gt;
53.  Next, the anterior portion of Tenon’s capsule and conjunctiva are then closed to form the second and third layers over the implant.  The horizontal rectus muscles are then attached to the medial and lateral fornix.  It is the movement of the fornix in the enucleated socket that provides the motility to the artificial eye. For example, as a person looks up. the inferior fomix shortens, the superior fornix deepens and the prosthesis revolves upward&lt;br /&gt;
54.  By utilizing the posterior layer of Tenon’s capsule,a larger implant can be placed deep within the muscle cone which  decreases the incidence of implant migration  reduces the tension on the anterior Tenon’s capsule sutures  reduces the volume deficit in the superior and inferior sulcus preventing enophthalmos which can be produced by smaller implants Orbital Sphere Introducer&lt;br /&gt;
55.  Postoperative complications may develop during the first weeks following surgery.  Early extrusion of the implant may occur secondary to  orbital hematoma formation and infection  traumatic manipulation of the tissues  placement of too large an implant thus creating excess tension on Tenon’s capsule  The technique of wrapping the orbital implant with fresh or preserved scleral tissue is thought to be a deterrent for extrusion and migration of the implant and it is a technique used quite frequently with enucleation&lt;br /&gt;
56.  After enucleation. a plastic conformer and corticosieroid antibiotic ointment is placed in the socket.  The conformer should fit the contour of the socket and fill the depths of the fornices.  The conformer should not be removed by the patient, as it is designed with drainage holes  to allow mucoid discharge to escape  for insertion of postoperative medication  The plastic conformer is left in place for 4 to 6 weeks to reduce edema and maintain the socket contours by stretching the fornices for the prosthetic eye. SMALL MEDIUM LARGE 20mm 23mm 26mm&lt;br /&gt;
57. • Following healing of the anophthalmic socket, a stock or custom eye should be placed temporarily for cosmetic and psychological reasons. • Patient should be taught how to insert and remove the eye (devote separate time, quiet room and a mirror) • Patient should be encouraged to minimize handling the artificial eye. • Daily removal and cleaning is not necessary.&lt;br /&gt;
58. Notch is superonasally&lt;br /&gt;
59.  Lubrication may improve comfort (no tap water! Ringers, Saline or Artificial Tears may work well instead, packed in the eyedrops bottles)  There is only one eye now.  Encourage using the protective plastic glasses  One artificial eye should serve for 6-8 years.  Easily gets damaged while dropped down  Advise annual check up.&lt;br /&gt;
60. Evaluating the socket of anophthalmic patient: 1) Socket is fit or infmalmed? 2) Lower lid is healthy or lax? 3) Can the patient blink naturally? 4) Any lagophthalmos? 5) Are the fornices deep enough? 6) Giant papillae of upper tarsal conjunctiva?&lt;br /&gt;
61. Evaluating the prosthesis 1) Artificial eye is well centered? 2) Horizontal symmetry? 3) Equal prominence? 4) High gloss, wet shine? 5) Scratches, debris of the surface? 6) Moving naturally within 10-15 degrees?&lt;br /&gt;
62. Types of ocular prosthesis  Spherical or oval  Stock or custom made  Porous or non porous  Chemical make up  Presence or absence of motility post.&lt;br /&gt;
63. impression of the socket is taken Once the impression material sets to a firm consistency, the shape is copied into a wax mold prepared iris–cornea piece is positioned on the front surface of the wax pattern. mold is placed into the socket and modifi ed (reshaped) for comfort and to improve cosmesis The wax shape is then translated (using additional molds) into fine quality acrylic (from methyl methacrylate resin), painted, cured, and polished. Modified impression technique&lt;br /&gt;
64. Prosthesis&lt;br /&gt;
65. CRITERIA FOR SUCCESS OF CRANIOFACIAL OSSEOINTEGRATED IMPLANTS (According to “Swedish council on Technology assessment in Health care”)  Implants are immobile as verified by clinical examination.  No prolonged symptoms, such as pain, infection, tactile disorders or nerve damage should be present in connection with the implants.  Penetrated soft tissue should be free from irritation in at least 85% of regular out patient postoperative checks.  At least 95% of the temporal bone implants and at least 75% of other extraoral implants should be functional after 5 years.&lt;br /&gt;
66. PROSTHETIC TECHNIQUES: I) Fabrication of the ocular prosthesis:  Ocular prosthesis is made in conjunction with the surgical positioner because its shape and position relate to the overall shape of the orbital prosthesis.  A stock eye piece can be used. However, custom fabrication yields the best aesthetic results.  A pyramidal index of acrylic resin is incorporated on to the back surface of the eyepiece to aid in registering its position in the wax prototype and for subsequent mold making&lt;br /&gt;
67. II) Impression making: Impression making for an orbital prosthesis varies depending on the anatomic the orbital defect, location of implants and type of retention system selected daily hygiene procedures should be performed by the patient to maintain the health of the soft stabilization of the soft tissue to ensure fit and marginal adaptation of the prosthesis. This allows time for adequate healing Impression is made 8 – 12 weeks after of the abutments.&lt;br /&gt;
68.  If individual magnets are used for retention, the MAGNACAPs are threaded into the abutments, and the transfer magnets are placed on them.  These can be connected with autopolymerising resin to stablize them in impression.  The impression can be made using irreversible hydrocolloid, a silicone rubber .  The impression should include the entire midface to provide adequate references and landmarks for accurate sculpting&lt;br /&gt;
69.  Orientation lines are marked on the patient indelible pencil and will be transferred to the cast to aid this process.  After removal of the impression and disinfection, LAB-ANALOGUE CAPS are placed the transfer magnets and the impression is poured in dental stone.&lt;br /&gt;
70. III Design and Fabrication of resin plate  The resin plate retains the retentive components in a rigid base and provides stability for the prosthesis.  In most cases, it should be as small as possible so as not to interfere with the placement of the ocular prosthesis  Magnets are placed on the lab-analogue caps on the cast.  Wax is used to block out the defect and the abutments&lt;br /&gt;
71.  The resin engages this area to help retain the magnets in the plate.  The area is bordered with boxing wax, and clear autopolymerising acrylic resin is poured over the area, covering the magnets and engaging the retentive rim.  The thickness should be minimal and uniform to control distortion  A sprinkle on method can be used to apply the resin to better control the thickness of the plate.  Alternatively, colourless urethane dimethacrylate visible light cure resin can be used to fabricate the plate.  It is cured initially on the cast with a handheld light and then placed in the curing unit to complete curing.  The processed plate is shaped not to interfere with the ideal contour of the prosthesis. It is adjusted on cast and then tried on the patient. Complete engagement of retentive elements should be verified&lt;br /&gt;
72. IV Sculpting the wax prototype:  To achieve a life like orbital prosthesis, attention to anatomy and surface detail is important.  Input from the patient and family members is encouraged during this process.  To begin the sculpting process, the ocular prosthesis is attached to resin plate with utility wax while both are on the mastercast, using the orientation lines as a guide. When the prosthesis is transferred to the patient, depth, position, and gaze are evaluated relative to natural eye.&lt;br /&gt;
73. One or more of the following are helpful in creating the wax prototype : the patient tissue conforme r computeri zed images Surgical positioner photograp hs measuring devices (boley and contour gauges, calipers)&lt;br /&gt;
74. V Mold making:  A three – piece mold of white improved dental stone is made : tissue side, eyepiece and outer surface.  Once the wax prototype is completed, its outline is marked on the cast with indelible pencil .  An impression of the defect extending beyond the margins of the prosthesis is made with duplicating silicone elastomer and resin forced with plaster backing.  The periphery of this impression is poured in stone so that the center of the defect is left open.  Registration keys are placed in the tissue side of the mold.  Lab-analogues of magnetic caps are placed on the magnets with in the resin plate&lt;br /&gt;
75.  The wax prototype is seated back on the cast by using the transferred pencil line as guide for orientation, and the margins are sealed.  Skin surface detail can be refined at this time  Stone is poured into the back of the wax prototype through the opening of the cast .  Once set, wax spacers to facilitate later mold seperation are placed in the first piece of the mold, a seperator is applied to the stone surface, paper tape or wax is used to box the mold, and the top portion or outer surface of the mold is poured .  Once the stone has set, the mold is separated and the eyepiece and resin plate are removed. The mold is cleaned with boiling water and detergent to remove all wax residue&lt;br /&gt;
76.  Before casting the prosthesis, silicone elastomer is used to make a mold of the outer surface of the resin plate while it is in place of on the tissue side of the mold.  The impression material should be applied with a syringe around the edges to capture the ledge on the tissue side of the plate.  Then a two piece silicone mold is of the eyepiece and this is poured in stone.  This stone reproduction is used in the mold in place of resin eyepiece during processing to protect it from damage.  These steps allow the resin plate and prosthesis to be remade without the patient and the prosthesis present, when a replacement prosthesis is necessary.&lt;br /&gt;
77. Maintenance of Prosthesis  To maintain the health of the implants and surrounding soft tissue and to preserve the prosthesis and retention mechanism.  Bone anchored facial prosthesis require more care on the patient’s part and closer professional follow-up than one retained with adhesive.&lt;br /&gt;
78. HOME CARE AFTER ABUTMENT CONNECTION  Follow up management actually begins once the abutments have been placed.  After the initial healing period and once a surgical dressing is no longer needed, the patient should be instructed to clean this area on a daily basis  to remove cellular material on the skin or abutment, which can come from the interface of the epithelium and abutment.&lt;br /&gt;
79.  This is performed with a soft, end tuft nylon bristle toothbrush, an interproximal dental brush or a cotton swab.  The area should be moistened first with an even mixture of H2O2 and H2O to soften any dried debris  When checking abutment tightness, an abutment clamp should be placed on the abutment body to provide countertorque so that undue force is not placed on the implant.  If the abutment loosens, complete seating should be verified before retightening. This is done with an abutment holder.&lt;br /&gt;
80. HOME CARE AFTER PROSTHESIS PLACEMENT  On the day that the prosthesis is given to the patient,adequate time should be allotted for instructions on placing and removing the prosthesis as well as proper maintenance of the prosthesis, abutments, and surrounding skin areas.  patient should be careful when removing the prosthesis so that the thin margins do not tear and the silicone rubber does not separate from the resin plate  At night, the prosthesis should be removed and cleaned.  The patients should wash their hands first to decrease chances of soiling the prosthesis during handling.  All surfaces of the prosthesis should be cleaned gently with a soft, nylon-bristle toothbrush and mild soap and water&lt;br /&gt;
81.  The prosthesis should be patted dry with a towel and placed in a covered container.  Should be stored away from extreme heat or direct sunlight, which can cause degradation and discolouration of the prosthetic material.  The prosthesis should not be worn during sleep so that air can circulate around the abutments to help maintain skin health&lt;br /&gt;
82. Complications&lt;br /&gt;
83. Exposure and Extrusion of Implant  Implant exposure may occur with any type of implant or at any time  may lead to implant extrusion or explantation&lt;br /&gt;
84. Porous orbital implants have a lower incidence of implant exposure than traditional nonporous implants Predisposing factors  1. closing the wound under tension 2. poor wound closure techniques 3. Infection 4. mechanical or inflammatory irritation from the speculated surface of the porous implant 5. Delayed ingrowth of fibrovascular tissue with subsequent tissue breakdown&lt;br /&gt;
85. Preventive measures for implant exposure  proper placement of the implant within the orbit  two-layered closure of anterior Tenon’s capsule and conjunctiva Treatment : If few weeks,  No infection simple reclosure or with a patch graft (eg, Sclera, temporalis fascia)  If infection is suspected vigorous treatment with topical and systemic antibiotics an extrusion and removal of the implant may be avoided.&lt;br /&gt;
86. beyond 4–6 months,  If non porous  The defect should not be closed secondary orbital implant surgery should be arranged  If porous, exposure &amp;lt;3mm &amp;gt;3mm Treat conservatively Wait 8 weeks for spontaneous closure no Close with scleral patch graft surgical repair is indicated Using sclera patch graft or temporalis fascia patch graft&lt;br /&gt;
87. TREATMENT OF VOLUME DEFECIT&lt;br /&gt;
88. Dermis fat graft&lt;br /&gt;
89. TREATMENT OF LID LAXITY&lt;br /&gt;
90. Lax socket and inferior fornix shelving :  results from shifting of tissues within the orbit  With time there is involutional relaxation of the supporting tissues of the inferior eyelid  the weight and pressure effect of the prosthesis  laxity of the lid  inability to retain the prosthesis Treatment  Use prosthesis of optimal weight and size  Lateral tarsal strip  fornix formation sutures to increase the depth of inferior fornix&lt;br /&gt;
91. FORNIX DEEPENING SUTURES&lt;br /&gt;
92. Anophthalmic ptosis  Inadequate implant size  Migration of the orbital implant  Poorly ﬁt prosthesis  Laxity of the ﬁbrous connective tissue  Orbit trauma from the original injury/surgery  Senile dehiscence of the levator aponeurosis  Frequent manipulation of the eyelids to insert and remove the artificial eye also stretches the upper eyelid tissues  drooping eyelid.&lt;br /&gt;
93. Pseudoptosis  Due to the loss of volume between the implant and the lids after removal of the eye.  Occurs with a small, poorly fitted prostheses  If the physiological function of the eyelids is intact, correction of pseudoptosis is achieved by increasing the volume of the prosthesis in the socket.  A simple technique of correcting pseudoptosis is to make a larger prosthesis that will thrust forward and separate the eyelids&lt;br /&gt;
94. Treatment  Small amounts of ptosis may be managed by modification of the prosthesis  correction of socket volume deficiency should be considered prior to levator surgery  Once the other factors contributing to ptosis in the anophthalmic socket have been addressed tightening of the levator aponeurosis can be done&lt;br /&gt;
95. Treatment of enophthalmos :  placement of a secondary orbital implant if no implant was placed at the time of primary surgery  Dermis fat graft (DFG) is an option in patients with associated surface contracture  Orbital floor implants. Autologous bone grafts Non autologous medpor Treatment of superior sulcal deformity  implantation of fascia lata / sclera / bone / fat/ alloplastic material in upper eyelid&lt;br /&gt;
96. Anophthalmic ectropion  Frequently associated with significant lower eyelid laxity  A large or heavy prosthesis or frequent prosthesis removal may contribute to a stretching of the medial and/or lateral canthal tendons  Rotation of the orbital contents inferiorly and anteriorly contribute to a shallow inferior fornix, tilt of the prosthesis, and lower eyelid ectropion&lt;br /&gt;
97. Treatment  If the prosthesis is &amp;gt;5 years old, a new one may be required  If the prosthesis is large then a thinner or lighter prosthesis may help correct the malposition  Tightening the lateral or medial canthal tendon may remedy the situation  Correction of eyelid retraction by recession of IR/ grafting of mucus membrane tissue inferior fornix&lt;br /&gt;
98. Contracted socket  extensive loss of conjunctiva surface area  deep scar formation  shrinkage of orbital fat  conjunctiva fornices contracture.  the shrinkage and shortening of orbital tissues  decrease in depth of fornices and orbital volume  leading to inability to retain prosthesis. Guibor has classified clinically contracted socket into 4 morphological types&lt;br /&gt;
99. Causes Etiology related ・Alkali burns ・Radiation therapy Surgery related  Fibrosis from the initial injury  Poor surgical techniques during previous surgeries -enucleation /evisceration with extensive dissection of orbital tissue  Excessive sacrifice of the conjunctiva and tenons capsule  Traumatic dissection within the socket leading to scar tissue  Multiple socket operations&lt;br /&gt;
100. Site related  Poor vascular supply  Severe ischemic ocular disease in the past  Cicatrizing conjunctival diseases  Chronic inflammation and infection Implant and prosthesis related  Implant migration  Implant exposure  Not wearing a conformer/prosthesis  Ill fitting prosthesis&lt;br /&gt;
101. Grades of contracted sockets.  The soft tissue sockets were divided into five grades for the sake of convenience in management of contracted sockets. Grade-0: Socket is lined with the healthy conjunctiva and has deep and well formed fornices.&lt;br /&gt;
102. Grade-I: Shallow lower fornix or shelving of lower fornix Here the lower fornix is converted into a downwards sloping shelf which pushes the lower lid down and out, preventing retention of a artificial eye. shallow lower fornix and deep upper fornix resulting in upward migration of the prosthesis&lt;br /&gt;
103. Grade-II: Socket is characterized by the loss of the upper and lower fornices&lt;br /&gt;
104. Grade- III: Socket is characterized by the loss of the upper, lower, medial and lateral fornices&lt;br /&gt;
105. Grade-IV: Socket is characterized by the loss of all the fornices, and reduction of palpebral aperture in horizontal and vertical dimensions&lt;br /&gt;
106. Grade-V: In some cases, there is recurrence of contracture of the socket after repeated trial of reconstruction&lt;br /&gt;
107. Aims of reconstruction  To establish stable fornices by increasing the surface area by (hard palate ,oral mucosal,skin graft) and if necessary by increasing size by orbital implant.  The ocular prostheses should be light and take its support from infraorbital rim not from the lids.&lt;br /&gt;
108. Surgical principle  First : obtain adequate palpepral aperture size (canthoplasty may be needed in grade3,4,5)  Second : create adequate fornixes (lower,upper,lateral) insicion central in grade 2 while it can be at inferior position in grade 1.  Third : perfect lining of the created fornix (hard palate ,oral mucosal,skin graft ,amniotic membrane)&lt;br /&gt;
109.  Fourth be sure that the fornix created supported by orbital bony rim to create a stable and deep lower fornix, the lower edge of the graft should be sutured to the inferior orbital bone rim using anchor sutures .  Fifth: the conformer used during healing for about 6 weeks then ocular shell prosthesis used there after.  Sixth : central temporary tarsorrhaphy may be used.&lt;br /&gt;
110.  Bone anchored implant  offers increased security especially with large defects or where the prosthesis rests on highly mobile tissues.  Perspiration and vigorous physical activity will not affect the retention  Independence from reliance on adhesives frees the patient from tedious task of applying and removing adhesive at each application and removal of prosthesis.  It prolongs the life of prosthesis, as the edges are not subjected to excessive handling  Follow-up for the clinical evaluation of implant tissues and the maintenance and periodic replacement of the facial prosthesis are a must&lt;br /&gt;
111. REFERENCES  Clinical Maxillofacial Prosthetics-Thomas d. Taylor  Maxillo Facial Rehabilitation – Prosthodontic and surgical consideration -JOHN BEUMER  Prosthetic rehabilitation-Keith.F.Thomas  Ophthalmic and Plastic and Reconstructive Surgery&lt;br /&gt;
112. THANK YOU!!!&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/3578294538771167245/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/orbital-implants.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/3578294538771167245'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/3578294538771167245'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/orbital-implants.html' title=' ORBITAL IMPLANTS'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-3306407834059684288</id><published>2020-04-17T20:30:00.000+05:30</published><updated>2020-04-17T20:30:05.742+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="CYCLODESTRUCTIVE PROCEDURES"/><category scheme="http://www.blogger.com/atom/ns#" term="enucleation"/><category scheme="http://www.blogger.com/atom/ns#" term="EVISCERATION"/><category scheme="http://www.blogger.com/atom/ns#" term="EXENTRATION"/><title type='text'>EVISCERATION, ENUCLEATION, EXENTRATION, CYCLODESTRUCTIVE PROCEDURES</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;iframe src=&quot;//www.slideshare.net/slideshow/embed_code/key/6kQUBPwlLAYqpX&quot; width=&quot;595&quot; height=&quot;485&quot; frameborder=&quot;0&quot; marginwidth=&quot;0&quot; marginheight=&quot;0&quot; scrolling=&quot;no&quot; style=&quot;border:1px solid #CCC; border-width:1px; margin-bottom:5px; max-width: 100%;&quot; allowfullscreen&gt; &lt;/iframe&gt; &lt;div style=&quot;margin-bottom:5px&quot;&gt; &lt;strong&gt; &lt;a href=&quot;//www.slideshare.net/ReshmaPeter3/evisceration-enucleation-exentration-cyclodestructive-procedures&quot; title=&quot;EVISCERATION, ENUCLEATION, EXENTRATION, CYCLODESTRUCTIVE PROCEDURES&quot; target=&quot;_blank&quot;&gt;EVISCERATION, ENUCLEATION, EXENTRATION, CYCLODESTRUCTIVE PROCEDURES&lt;/a&gt; &lt;/strong&gt; from &lt;strong&gt;&lt;a href=&quot;https://www.slideshare.net/ReshmaPeter3&quot; target=&quot;_blank&quot;&gt;Reshma Peter&lt;/a&gt;&lt;/strong&gt; &lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
1. EVISCERATION ,ENUCLEATION ,EXENTRATION AND CYCLODESTRUCTIVE PROCEDURES Dr. Reshma Peter&lt;br /&gt;
2. SURGICAL PROCEDURES IN THE REMOVAL OF AN EYE Classified into three categories EVISCERATION Removal of the contents of the globe leaves the sclera ,fat,EOM, and other adjacent structures of the eye intact and sometimes the cornea in place. ENUCLEATION Removal of the eye leaves EOM and remaining orbital contents intact. EXENTERATION Removal of the entire contents of the orbit including EOM&lt;br /&gt;
3. EVISCERATION • A surgical technique by which all intraocular contents are removed • Scleral shell, EOM attachments, surrounding orbital adnexa preserved • The surgery often includes placement of an implant into the cavity to maintain appropriate orbital volume.&lt;br /&gt;
4. Indications • Panophthalmitis, Endophthalmitis • Penetrating ocular trauma • Blind, painful eye • Expulsive Choroidal haemmorhage • Bleeding Anterior Staphyloma&lt;br /&gt;
5. Contraindications • Known or suspected intraocular malignancy Relative Contraindications • Phthisis bulbi • Microphthalmia&lt;br /&gt;
6. • Careful pre-operative evaluation to ensure there is no intraocular malignancy in the operative eye • Performed under GA or in some cases, IV monitored sedation. • Retrobulbar anesthesia with epinephrine is often given to reduce intraoperative bleeding and postoperative pain.&lt;br /&gt;
7. Surgical Technique • A 360-degree conjunctival peritomy is then made at the limbus utilizing Wescott scissors undermine the conjunctiva and Tenon’s capsule • A full-thickness incision is then made at the limbus so that scissors may be introduced to excise the cornea in a circumferential manner. • All intraocular contents, including uveal tract, crystalline lens, vitreous humor, and retina are then removed by using an evisceration spoon, spatula, suction. • These contents are sent for histopathologic examination. • Sclera is swabbed with Absolute Alcohol to denature adherent uveal remnants and irrigated properly to remove alcohol&lt;br /&gt;
8. • Hemostasis of the nerve and vortex veins may then be achieved with cautery and direct pressure. • In some cases, a posterior sclerotomy or radial scleral relaxing incisions to allow for a larger implant to be placed. • The best implant size to restore orbital volume is selected while ensuring appropriate position. • Implant material is made of different materials like acrylic, PMMA, silicone, and hydroxyapatite. • The implant may be placed directly into the scleral shell&lt;br /&gt;
9. • The anterior sclera, Tenon’s capsule, and conjunctiva is then carefully closed in a layered approach before placement of a conformer. • Sclera is sutured with interrupted 6-0 Vicryl • • Conjunctiva with running mattress 6-0 Vicryl • A temporary tarsorrhaphy may be performed to help the conformer remain in place to maintain the fornices till prosthesis can be placed&lt;br /&gt;
10. • Perioperative antibiotics are often administered and are especially important in the setting of endophthalmitis. • A pressure patch may be applied and kept in place for approximately 5 days following surgery. • Ice cold compresses help with post-operative edema and comfort • Once the conjunctiva closure has healed, generally about 4-8 weeks postoperatively, patients are referred to an ocularist for fitting of an ocular prosthetic fitting.&lt;br /&gt;
11. 4-petal technique of Evisceration It has several advantages over the traditional evisceration technique. • allows placement of a larger implant • enables double-breasting of scleral cover • eliminates the need for a myo-conjunctival technique. • The vertical closure of the conjunctiva retains the depth of the lower fornix, which is of importance to retain the ocular prosthesis.&lt;br /&gt;
12. Frill evisceration Technique only 3mm frill of sclera is left around Optic Nerve • If a scleral buckle or glaucoma drainage device is present in the eviscerated eye, it should be removed. • If silicone oil is present within the eye, the limbus can be incised and the silicone oil irrigated from the eye prior to peritomy. • Evisceration with removal of cornea done for those with corneal sensation /pain or in CT disorders/ RA –chances of corneal thinning&lt;br /&gt;
13. Complications • Retrobulbar hemorrhage • Orbital edema • Dissemination of unexpected intraocular neoplasm • Extrusion of implant&lt;br /&gt;
14. Advantages of Evisceration over Enucleation 1. Shorter operative time 2. More cost efficient 3. A technically simpler procedure 4. A less invasive procedure (important in cases when GA is contraindicated or in bleeding disorders) 5. Less disruption of orbital tissues – chance of injury to EOM ,nerves and fat atrophy is reduced – Relationships between the muscles, globe, eyelids, and fornices remain undisturbed – Less chance of spread of infection to nervous system&lt;br /&gt;
15. 6. Less painful 7. Better cosmesis 8. Good motility of the prosthesis- EOM remain attached to the sclera 9.Lower rate of migration, extrusion, reoperation and socket complications 10.Preferred by some surgeons in cases of endophthalmitis as drainage of the ocular contents can be done without invasion of the orbit. • The chance of contamination of the orbit with orbital cellulitis or intracranial extension is therefore theoretically reduced.&lt;br /&gt;
16. Disadvantages of Evisceration over Enucleation • Risk of sympathetic ophthalmia • Risk of dissemination of intraocular tumors • Offers a less complete specimen for pathologic examinations. • Not every patient is a candidate. C/I if intraocular tumours are suspected and in Severe Pthisis&lt;br /&gt;
17. ENUCLEATION • A surgical procedure that involves removal of the entire globe and its contents. • all other periorbital and orbital structures including parts of EOM and orbital fat preserved.&lt;br /&gt;
18. Indications • Eye donation • Intraocular malignancy or high suspicion for intraocular malignancy (most commonly uveal melanoma and retinoblastoma) • Trauma • Blind, painful eye • Sympathetic ophthalmia • Microphthalmia • Phthisis bulbi • Endophthalmitis • Cosmetic deformity&lt;br /&gt;
19. • Performed under GA or LA • A retrobulbar block of local anesthetic with epinephrine is administered to aid in hemostasis and postoperative pain management. • Lateral canthotomy to get adequate space (especially in paediatric RB)&lt;br /&gt;
20. Surgical Technique • A 360 degrees limbal conjunctival peritomy is performed with Wescott scissors • Blunt dissection in the sub-Tenon&#39;s plane is then carried out in each of the oblique quadrants. • Each rectus muscle is then identified, isolated with a muscle hook, secured with double arm 6-0 vicryl suture, and cut at the insertion to the globe leaving an adequate stump with traction suture • The superior and inferior oblique muscles are isolated and transected. • Once the globe is determined to rotate freely, the optic nerve is identified, strummed, and cut with enucleation scissors or an enucleation snare wire.&lt;br /&gt;
21. • A long segment of the optic nerve is cut , particularly in intraocular malignancy for histologic examination. Curved scissors inserted orbital apex palpated with tip, withdraw slightly, confirm Optic N. which is severed with a single cut • Additional hemostasis achieved with direct pressure in the intraconal space and cautery of the optic nerve if needed. • Needles of double armed recti sutures passed through respective fornices and tied on ant surface of conjunctiva thus securing recti to fornix. • An implant is then placed in the intraconal space to replace volume lost, achieve cosmetic symmetry with the fellow socket, and allow for motility of the prosthesis. • To determine appropriate diameter of the implant, the formula axial length-2 mm has been shown to provide for adequate replacement of lost volume and minimize superior sulcus deformity and enophthalmos.&lt;br /&gt;
22. • In severe infection,implant is placed in a second surgery. • A two-layered closure with 6-0 vicryl is then carried out with absorbable sutures, first of tenon’s capsule (interrupted suture)and then of the conjunctiva(running mattress suture). • Antibiotic ointment is applied, a clear plastic conformer is placed over the closed conjunctiva • A pressure patch is placed over the socket. • Once the conjunctiva closure has healed,about 4-8 weeks postoperatively, patients are referred to an ocularist for fitting of an ocular prosthetic fitting. • Patients will require regular follow up with both an oculoplastic surgeon and an ocularist to maintain the health of their socket.&lt;br /&gt;
23. Advantages • Enucleation allows for histologic examination of an intact globe and optic nerve. • This is important in biopsy of proven or suspected intraocular malignancy, where it is essential to determine the margins of the malignancy and invasion of the optic nerve, if any. • Enucleation classically has been thought to decrease the risk of sympathetic ophthalmia as it avoids exposure to uveal antigens that may occur during an evisceration.&lt;br /&gt;
24. Disadvantages A reduction in implant motility is often noted in enucleation.&lt;br /&gt;
25. Complications Intraoperative • Removal of the wrong eye • Damage to or loss of extraocular muscles • Hemorrhage Postoperative • Infection • Hemorrhage • Wound dehiscence • Extrusion of the conformer • Contraction of the fornices • Exposure of the implant • Extrusion of the implant • Migration of the implant • Ptosis • Ectropion • Entropion • Hollow or deep superior sulcus • Poorly fitting prosthesis • Enophthalmos • Socket contracture • Orbital cellulitis&lt;br /&gt;
26. EXENTRATION • A surgical procedure involving removal of the entire globe and its surrounding structures including muscles, fat, nerves, and eyelids (extent determined by disease being treated) • The goal is to remove all lesions along with appropriate margins of adjacent tissue while retaining as much healthy tissue as possible. • The technique selected depends on the pathologic process.&lt;br /&gt;
27. Varieties of orbital exenteration Subtotal : The eye and adjacent intraorbital tissues are removed such that the lesion is locally excised (leaving the periorbita and part or all of the eyelids). This technique is used for some locally invasive tumors, for debulking of disseminated tumors, or for partial treatment in selected patients. Total: All intraorbital soft tissues, including periorbita, are removed, with or without the skin of the eyelids. Extended: All intraorbital soft tissues are removed, together with adjacent structures(usually bony walls and sinuses).&lt;br /&gt;
28. Varieties of orbital exenteration • Anterior (part or full eyelids, conjunctiva, eyeball, anterior orbit) • Anterior and short of apex • Total/radical (all the above upto apex) • Extended (orbit and one of the paranasal sinuses) • Super (exenteration with orbitectomy) • Eyelid-sparing (can be used with any of the above). Following removal of the orbital contents, the bony socket may be  allowed to spontaneously granulate and epithelialize or  covered by a split-thickness skin graft, which may be placed onto bare bone or over a temporalis muscle or temporoparietalfascial flap.&lt;br /&gt;
29. Indications • Orbital malignancies  Cutaneous tumours with orbital adnexa invasion including squamous cell carcinoma, basal cell carcinoma, and sebaceous cell carcinoma.  Less common tumors include conjunctival malignant melanoma, adenoid cystic carcinoma of the lacrimal gland, and uveal melanoma with extrascleral extension  Intraocular melanomas or retinoblastomas • Painful or life-threatening orbital infections • Mucormycosis • Chronic orbital pain • Orbital deformities&lt;br /&gt;
30. Lid Sparing Exenteration Technique • GA should be used if possible. • If GA is C/I ,local retrobulbar, infraorbital, and periorbital nerve blocks may be used • A 4-0 black silk suture is passed through the skin, orbicularis muscle, and superficial tarsus of the upper and lower lids and tied together to close the eyelids and to provide traction during the procedure. • A skin incision is outlined 2 mm above and below the upper and lower lash line and extended to just beyond the medial and lateral canthi&lt;br /&gt;
31. • The incision is placed only through the eyelid skin and orbicularis oculi muscle, which is then undermined superiorly and inferiorly until the periosteum just outside the orbital rim is exposed for 360°. • An incision is then made through the periosteum for 360° about 2 mm outside of the orbital rim to expose the underlying bone. • A periosteal elevator is used to free the periosteum for 360° around the bony orbital margin and into the orbital cavity. • Small bleeding vessels posteriorly between the periosteum and the bone may be difficult to control.&lt;br /&gt;
32. • When the periosteum is free posteriorly, the enucleation scissors are inserted between the periosteum and bone on the inferonasal side and gently advanced to the orbital apex. • The tissues are then cut as near to the orbital apex as possible, and the orbital contents are removed by continued traction on the silk sutures in the eyelids while cutting the residual adhesions in the posterior orbit. • The socket is immediately packed with moist gauze, which is left in place for 5 to 10 minutes. • The gauze is then removed and the orbital apex inspected. •&lt;br /&gt;
33. • Residual soft tissue at the orbital apex is removed piecemeal, and Bovie cautery and repeat packing are used until there is no further bleeding. • A rubber drain is placed in the socket after complete hemostasis, and the skin of the upper and lower eyelids are sutured together with interrupted 5-0 silk sutures. • This leaves the residual orbital cavity filled with air. • One skin suture is tied to the drain.&lt;br /&gt;
34. • The drain suture is removed in 12 to 24 hours, and the drain is removed in 24 to 48 hours, depending on when drainage has ceased. • The skin sutures are removed in about 1 week, and dressings are not required. • The remaining eyelid skin gradually retracts into the socket and provides a more cosmetically acceptable lining of the socket after exenteration. • An orbital prosthesis can be fitted within 3 to 4 weeks.&lt;br /&gt;
35. Advantages to a lid-sparing technique • The wound heals faster • less postoperative follow-up is required. • The quicker healing allows radiotherapy where required. • A smooth healthy surface of the socket allows the use of a stick-on orbital prosthesis, rather than a spectacle mounted one.&lt;br /&gt;
36. Total Exenteration Technique • Two 4-0 silk tarsorrhaphy sutures are placed which will also act as traction sutures throughout the case. • A monopolar cautery is then used to make an incision through the skin and orbicularis muscle at the orbital rim 360 degrees. • Dissection is the carried out to the orbital rim laterally as well as inferiorly. • The superior orbital rim is identified and the periosteum is elevated. The lateral orbital rim is incised along the periosteum.&lt;br /&gt;
37. • Laterally the periosteum is elevated from the lateral orbital rim and lateral wall. • In this area one will usually encounter structures corresponding to the zygomatico facial and zygomatico maxillary neurovascular bundles. • The supraorbital neurovascular bundle is identified and transected with the monopolar cautery. • Medially, the anterior ethmoidal neurovascular bundle is identified and cauterized.&lt;br /&gt;
38. • Posteriorly, the posterior ethmoidal neurovascular bundle is identified and cauterized. • After transection of the infraorbital fissure as well as the nasolacrimal duct, the curved scissors are used to transect the posterior obit. • One can apply a snare prior to transection as the ophthalmic artery is transected and there will be significant bleeding. • Hemostasis is attained with the bipolar cautery. • A posterior orbital biopsy can be obtained if needed. • The area is then packed for hemostasis prior to harvesting of the split thickness skin graft.&lt;br /&gt;
39. Complications • Extensive bleeding, rarely necessitate a blood transfusion. • Fracture of thin ethmoid bones during the surgery, leading to an opening between the orbit and the nasal cavity. • Postoperative infection-appropriate antibiotics. • Sloughing of the skin graft. • Sino orbital fistula • Intracranial infections –CSF leak can be eliminated by obliterating the cavity in its entirety with soft- tissue free-flaps which provides  a safer and more therapeutic management of the socket leading to improved postoperative management and cosmetic outcome.  protective barrier that protects the cranium from a potential infection.&lt;br /&gt;
40. Ideal anophthalmic socket 1. A socket lined with healthy conjunctiva and fornices deep enough to retain a prosthesis and to permit horizontal and vertical movements of an artificial eye 2. Eyelids with normal position ,appearance and adequate tone to support a prosthesis 3. A supratarsal eyelid fold that is symmetric with that of the C/l eyelid&lt;br /&gt;
41. 4. Normal position of the eyelashes and eyelid margin 5.A centrally placed, well-covered, buried implant of adequate volume, fabricated from a bio-inert material 6. Good transmission of motility from the implant to the overlying prosthesis 7. A comfortable ocular prosthesis that looks similar to the sighted, contralateral globe and in the same horizontal plane&lt;br /&gt;
42. CYCLODESTRUCTIVE PROCEDURES • Destruction of the ciliary body has been used to treat glaucoma since the 1930s. • In cyclodestructive procedures, the secretory epithelium of the ciliary epithelium is damaged, which leads to reduced aqueous humor secretion and lower IOP. • Coagulation of proteins of epithelial cells ,closing nearby capillariesablation of ciliary epithelium without destroying ciliary body • Because the ciliary epithelium can regenerate, multiple treatments are necessary in some patients to achieve the desired long term IOP lowering effect.&lt;br /&gt;
43. The different modalities to achieve cyclodestruction are: diathermy, surgical excision, cryotherapy, ultrasound, and laser light Cyclophotocoagulation (CPC) is the most common procedure to perform cyclodestruction. It can be performed using different laser wavelengths • CPC was first performed by Beckman using a ruby laser (693 nm wavelength). • Nd:YAG laser (1064 nm wavelength has been used either with non-contact or contact methods to achieve cyclodestruction.&lt;br /&gt;
44. Contact Nd Yag- • Uses hand held probe placed on conjunctiva to to allow energy transmission directly to ocular surface • lesser power required as contact pressure increases scleral transparency • 32 to 40 spots over 360 degrees • 7 watts for 0.7 seconds for each spot Non Contact Nd Yag- • Transmits laser through air from slitlamp delivery system • 32 to 40 spots over 360 degrees • 8 Joules for 20 msec&lt;br /&gt;
45. • Presently, diode laser (810 nm wavelength) either transsceral or with an endoscopic probe is used to perform CPC. • The diode laser is preferred over other wavelengths since the melanin in the ciliary epithelium better absorbs this wavelength than others and therefore causes more targeted destruction with less inflammation. • It requires 50 %lesser power than with Nd Yag&lt;br /&gt;
46. There are 3 basic approaches to cyclodestruction (cycloablation): • Cyclocryotherapy • Trans-scleral laser cycloablation • Endoscopic laser cycloablation All 3 techniques share the common goal of decreased aqueous production, and all share the possible side effects of inflammation (including possible sympathetic ophthalmia), ineffective treatment, and over-treatment with resultant hypotony or even phthisis.&lt;br /&gt;
47. • cycloablation procedures mostly reserved for those cases refractory to, or not amenable to angle surgery, glaucoma drainage implant surgery, and trabeculectomy • For Refractory pediatric glaucoma , cyclodestruction represents a valid method of attempting control of glaucoma that threatens residual vision or causes ongoing damage to the structure of the child&#39;s eye. • Conventionally used only in eyes with poor visual potential, but can be employed in cases with reasonable vision to prevent severe glaucomatous damage occurring whilst neovascularization is brought under control. • Lowering IOP improves comfort, and clearing corneal oedema may facilitate an adequate retinal view for PRP • Recently TS-CPC has been performed in patients with good vision with good results.&lt;br /&gt;
48. CYCLOCRYOTHERAPY Indications • Other treatment modalities exhausted • Cases when TDC or ECP is anatomically challenging to perform&lt;br /&gt;
49. Technique • The oldest cyclodestructive method • involves freezing the ciliary processes from an external approach • reserved for those refractory pediatric glaucoma cases in which anatomy limits the likelihood of successful ciliary body treatment with either trans-scleral or endoscopic cyclophotocoagulation or access to these technologies is truly unavailable and incisional surgery is impossible&lt;br /&gt;
50. • cyclocryotherapy in pediatric eyes should be limited to a maximum of 6 clock hours (180 degrees of the eye&#39;s circumference) at any 1 session, using approximately 1 freeze-spot per clock-hour (45–60 seconds each at 280ºC) • Given with the anterior edge of a &quot;large&quot; 2.5-mm diameter cryoprobe attached to liquid Nitrogen supply placed at 1–1.5 mm posterior to the limbus in a nonbuphthalmic globe • avoid the 3 and 9 o&#39;clock locations to minimize damage to the long posterior ciliary vessels.&lt;br /&gt;
51. • Extent of freeze ball -10 -12 mm , extending up to corneal limbus • Any especially thin area of the limbus should also be avoided • care should be taken to avoid contact with adjacent lid tissue and to shorten treatment if the &quot;freeze zone&quot; gets larger than approximately 1 cm, which can happen as the entire eye &quot;cools down&quot; with sequential freeze applications.&lt;br /&gt;
52. • Where limbal anatomy is distorted or difficult to evaluate, transillumination can help identify the proper treatment location. • During cyclocryotherapy repeat sessions, care should be taken to leave at least 1 quadrant untreated because with overtreatment, chronic hypotony or phthisis can be permanent.&lt;br /&gt;
53. Advantages • Short surgical time and rapid rehabilitation • Technically easy&lt;br /&gt;
54. Disadvantages • Often needs to be repeated due to ciliary body recovery • Most patients remain on medical therapy. • Risk of phthisis bulbi • Scleral thinning at cryo sites can affect future drainage device surgery. • Proinflammatory and can accelerate cataract formation • Post op IOP spike- due to volumetric change in intraocular contents caused by intravitreal iceball.&lt;br /&gt;
55. TRANS-SCLERAL DIODE-LASER CYCLOPHOTOCOAGULATION (DIODE TS-CPC) • Laser energy can be directed through the sclera to treat the ciliary processes using a probe in contact with the sclera over the intended treatment site. • Used in pediatric glaucoma, refractory to other measures using both the Nd:YAG laser and the diode laser. • Although reported to produce less inflammation than cyclocryotherapy in adults, risks of serious complications • Ultrasound biomicroscopy recently has been described as a guide to proper placement of the probe for TDC&lt;br /&gt;
56. TRANS-SCLERAL DIODE-LASER CYCLOPHOTOCOAGULATION (DIODE TS-CPC) • The only eligibility requirement-eye must have some degree of functioning aqueous outflow. • TSCPC decreases aqueous outflow , thereby decreasing IOP • C/I in Uveitis • Preop vasoconstriction with Alpha agonist (Alphagan P) decrease energy absorption by conjunctival vesselsless likelihood of SCH&lt;br /&gt;
57. Indications for Transcleral Cyclophotocoagulation • Elevated IOP with poor vision or poor visual potential • Pain relief due to elevated IOP in a blind painful eye • Uncontrolled glaucoma in the presence of conjunctival scarring from previous surgery • Patient&#39;s medical condition preclude going to operating room • Patient refuses surgery in OT • Failed angle surgery and minimal visual potential • Failed trabeculectomy and/or aqueous drainage with poor central vision • Inadequate IOP control after drainage device • Anatomy precluding trabeculectomy or glaucoma drainage device, e.g., disorganized anterior segment, thin limbus • Gravely ill children, poor follow-up, blind in fellow eye from complication of intraocular surgery • Uncontrolled IOP post surgery in Primary open-angle glaucoma,Angle-closure glaucoma,Neovascular glaucoma,Pseudophakic/aphakic glaucoma,Pediatric glaucoma,Glaucoma after penetrating keratoplasty,Uveitic glaucoma,Silicone oil induced glaucoma&lt;br /&gt;
58. Procedure • Diode TS-CPC can be performed in a minor procedure room or in an OT. • Retrobulbar or peribulbar anesthesia is needed, as the procedure is painful. • A lid speculum helps to provide better exposure to the peri-limbal area. • A semi-conductor solid state diode laser with a wavelength of 810 nm • A handpiece –G probe is used to deliver the laser energy.&lt;br /&gt;
59. • G probe- 600u diameter Quartz glass fibre , placed 1mm posterior to limbus, mild pressure to indent conj and sclera • Initial power of 1250 mW and duration of 4 seconds. • The power is increased in 150 mW increments until an audible “pop” is heard. • The audible “pop” signifies tissue explosion of the ciliary process, the iris root, or the retina&lt;br /&gt;
60. • When a “pop” is heard the power is decreased by 150 mW until there is no audible “pop”. • The maximum power used is 2250 mW. • Others will start at 2000 mW and 2 seconds and titrate the energy down. Generally 6 spots are used per quadrant for a total of 18 spots.&lt;br /&gt;
61. • Some surgeons recommend treating only 3 quadrants to avoid anterior segment necrosis and many recommend sparing the 3:00 and 9:00 positions. • After completion of the procedure a topical antibiotic, steroid, and cycloplegic agents are placed on the eye. • The eye should be patched after a block is used to protect the cornea. • The patient is seen the next day for follow-up.&lt;br /&gt;
62. Advantages • Short surgical time and rapid rehabilitation • Technically easy • Lesser power as compared with cryo as more efficiently absorbed by ciliary body In cryodiffusely absorbed by all structures • Contact method-less scatter , thus less energy required&lt;br /&gt;
63. Disadvantages • Often needs to be repeated due to ciliary body recovery • Most patients remain on medical therapy. • Risk of phthisis bulbi, but less than cryo • Beware risk of perforation at sites of scleral thinning. • Proinflammatory and can accelerate cataract formation&lt;br /&gt;
64. Complications • IOP spikes –Preop and post op oral CAI –Azetazolamide or Methazolamide • Pain is usually transient and controlled with analgesics • Hyphema more frequently in neovascular glaucoma patients. • Iridocyclitis occurs commonly after TS-CPC. Few patients can develop a chronic low-grade anterior chamber inflammation due to a breakdown in the blood-aqueous barrier. • Conjunctival burns rarely if conjunctival surface becomes dry during laser with high energy settings ,in darkly pigmented conjunctiva and due to the use of defective, damaged, or soiled laser probes. • Hypotony&lt;br /&gt;
65. • Vision loss can occur after TS-CPC • Phthisis bulbi is a rare complication • Malignant glaucoma • necrotizing scleritis • sympathetic ophthalmia • Scleral perforation has been reported with TDC so care should be taken to ensure that the probe surface is clean of debris and to avoid areas of obvious scleral thinning and the site of previous surgeries (do not laser where the tube passes and the previous trabeculectomy site).&lt;br /&gt;
66. Variation in clinical response • Variation in pressure exerted over sclera • Difference in scleral thickness • Variation in probe inclination&lt;br /&gt;
67. ENDOCYCLOPHOTOCOAGULATION (ECP) Employs fibreoptic cable to deliver pulsed continuous wave diode laser energy to ciliary processes under direct endoscopic visualization using video monitor • Used as a treatment for refractory pediatric glaucoma, allowing more precise localization of the target and treatment with much lower energy than required for trans- scleral laser. • The most commonly used system uses a diode laser equipped with a 20-gauge probe, within which is housed fiber optics for a video monitor, diode laser endophotocoagulation, and illumination • ECP can be combined with phacoemulsification to treat cataract and glaucoma at the same time In combined cases ECP can be performed before or after inserting the intraocular lens in the lens bag.&lt;br /&gt;
68. Indications for Endocyclophotocoagulation • Same indications as TDC but anatomy of eye allowing limbal or pars plana approach to ciliary processes but beware of cataract in phakic eyes • To Consider after TDC has failed. • Patients who are poor candidates for glaucoma filtration surgery or glaucoma drainage implant • Distorted anterior segments • In uncontrolled Primary open-angle glaucoma,Pseudoexfoliation glaucoma,Neovascular glaucoma,Pseudophakic glaucoma,Glaucoma after penetrating keratoplasty,Glaucoma associated with retinal surgery,Pediatric glaucoma,Angle-closure glaucoma&lt;br /&gt;
69. Technique • The ECP laser unit has 4 different components, the diode laser (pulsed continuous-wave energy at 810 nm), a xenon light source, a helium-neon laser aiming beam, and video monitor and recorder. • The probe is 20 gauge with a full view of 110 degrees and depth of focus of 1-30mm. • The equipment console consists of the video camera, light source, video monitor, and the video recorder.&lt;br /&gt;
70. • Initially the laser probe is placed into the anterior chamber by looking through the surgical microscope. • Then the surgeon looks through the video monitor to locate the ciliary processes and perform the laser photocoagulation • The goal of each laser application is to whiten and shrink the ciliary process. • The entire ciliary process should be treated. • Generally 270-360 degrees of the ciliary processes are treated.&lt;br /&gt;
71. • Gas bubble formation, pigmentary dispersion, audible “pops”, photocoagulation of non-ciliary process tissue should be avoided • The laser settings are as follows: Power 0.2 W, continuous-wave mode. • The power is titrated to achieve whitening and shrinkage of the ciliary process by positioning the probe either closer or further from the processes. • Ideally, 3 processes should be within view during treatment.&lt;br /&gt;
72. • ECP can be performed in phakic, pseudophakic, or aphakic eye with the endolaser probe through the limbus or pars plana. In the limbal approach, • a 1.5-2.0 mm incision is made in the clear cornea or sclera. • A cohesive viscoelastic is injected posterior to the iris and anterior to the lens capsule to deepen the ciliary sulcus space. • Next the probe is placed in the anterior chamber. • The ciliary processes are visualized and treated. • The viscoelastic is removed.&lt;br /&gt;
73. • In phakic patients great care should be taken not to nick the anterior lens capsule. • In pseudophakic/aphakic eyes, the pars plana approach is advantageous since the ciliary processes are better visualized. • The incision is made 3.5-4.0mm posterior to the limbus. • Infusion port through pars plana • 2 superior entries for vitrectomy and illumination • Anterior vitrectomy is performed for adequate and safe access to ciliary processes • Then cyclophotocoagulation with the endolaser probe is performed.&lt;br /&gt;
74. Post-operative Management • Cycloplegics (atropine 1% BD for 2 weeks) • Topical corticosteroids (prednisolone acetate 1% QID; In extensive anterior chamber inflammation increase frequency) • Topical antibiotics • Subtenon’s steroid injection and/or oral steroids • The pre-laser glaucoma medications continued post- operatively and tapered based on the IOP lowering effect of the laser.&lt;br /&gt;
75. • Miotics should be stopped because they can enhance the inflammatory response and cause posterior synechiae. • Consideration stopping PG analogs if IOP is well controlled since they can cause anterior chamber inflammation.&lt;br /&gt;
76. Advantages • Short surgical time and rapid rehabilitation • Allows precise treatment due to direct visualization and avoids risk of scleral perforation • Important in Severe Congenital Glaucoma where eyeball is enlarged and ciliary processes may be displaced • Can produce less inflammation and collateral tissue damage than TDC and cryo • less power needed&lt;br /&gt;
77. Disadvantages • Often needs to be repeated due to ciliary body recovery • Most patients remain on medical therapy • Risk of phthisis bulbi, but less than TDC and cryo • Proinflammatory, but less than TDC and cryotherapy • Intraocular approach with risk of endophthalmitis and cataract formation&lt;br /&gt;
78. Complications • IOP spikes • Fibrin exudates • Hyphema • Cystoid edema • Vision loss of 2 lines or more • Hypotony • Zonular damage • Rarely ,phthisis bulbi, endophthalmitis, or sympathetic ophthalmia • Retinal detachment • Serous and haemorrhagic choroidal detachment • Traumatic injury to the iris Mechanical trauma/ laser improperly applied to the iris&lt;br /&gt;
79. Transpupillary cyclophotocoagulation • In people with visible ciliary processes • In traumatic aniridia and in people with large iridectomies • in advanced neovascular glaucoma, when iris is pulled ant and peripherally • With a slit lamp delivery system through Goldmann 3 mirror lens • Using Argon green or Nd YAG • 3-4 applications to coagulate all visible portion • End point is blanching of ciliary body, blisters,/effusion of pigment&lt;br /&gt;
80. • Cyclodestruction has limited success and the risk of severe complications when used for treatment of refractory pediatric glaucoma. • Nonetheless, this modality retains an important role in the management of selected eyes with refractory glaucoma. • Cyclodestruction in the treatment algorithm depends on several factors  visual potential  anatomic features  prior surgical interventions  glaucoma severity  overall health&lt;br /&gt;
81. • Both TDC and ECP can represent adjunctive techniques after prior glaucoma drainage device surgery has incompletely controlled the IOP and can be reasonable primary surgery in selected eyes with challenging anatomy for other intraocular glaucoma procedures. • Cyclodestruction should be used with extreme caution in eyes with uveitis because all 3 techniques produce significant inflammation as well as the potential to produce retinal detachment, hypotony, phthisis, and even sympathetic ophthalmia.&lt;br /&gt;
82. References 1. Bosniak –Ophthalmic Plastic and reconstructive Surgery 2. AAO series –Orbit 3. Stellard’s Eye Surgery 4. Becker schaffer’s Diagnosis and therapy of Glaucomas 5. Kanski ‘s Clinical Ophthalmology 6. Post Graduate Ophthalmology by Zia CHaudhuri 6. AAO series- Glaucoma&lt;br /&gt;
83. THANK YOU !!&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/3306407834059684288/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/evisceration-enucleation-exentration.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/3306407834059684288'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/3306407834059684288'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/evisceration-enucleation-exentration.html' title='EVISCERATION, ENUCLEATION, EXENTRATION, CYCLODESTRUCTIVE PROCEDURES'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-6284582177236124812</id><published>2020-04-17T19:00:00.000+05:30</published><updated>2020-04-17T19:00:04.354+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Orbital Reconstruction After Repeat Orbital Exenteration"/><title type='text'>Orbital Reconstruction After Repeat Orbital Exenteration</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;iframe allowfullscreen=&quot;&quot; frameborder=&quot;0&quot; height=&quot;485&quot; marginheight=&quot;0&quot; marginwidth=&quot;0&quot; scrolling=&quot;no&quot; src=&quot;//www.slideshare.net/slideshow/embed_code/key/EiOwPLVZv64jyW&quot; style=&quot;border-width: 1px; border: 1px solid #ccc; margin-bottom: 5px; max-width: 100%;&quot; width=&quot;595&quot;&gt; &lt;/iframe&gt; &lt;br /&gt;
&lt;div style=&quot;margin-bottom: 5px;&quot;&gt;
&lt;b&gt; &lt;a href=&quot;https://www.slideshare.net/DrJagannathBoramani/orbital-reconstruction-after-repeat-orbital-exenteration&quot; target=&quot;_blank&quot; title=&quot;Orbital Reconstruction After Repeat Orbital Exenteration&quot;&gt;Orbital Reconstruction After Repeat Orbital Exenteration&lt;/a&gt; &lt;/b&gt; from &lt;b&gt;&lt;a href=&quot;https://www.slideshare.net/DrJagannathBoramani&quot; target=&quot;_blank&quot;&gt;Dr. Jagannath Boramani&lt;/a&gt;&lt;/b&gt; &lt;/div&gt;
&lt;br /&gt;
&lt;!--[if gte mso 9]&gt;&lt;xml&gt;
 &lt;o:OfficeDocumentSettings&gt;
  &lt;o:AllowPNG/&gt;
 &lt;/o:OfficeDocumentSettings&gt;
&lt;/xml&gt;&lt;![endif]--&gt;&lt;!--[if gte mso 9]&gt;&lt;xml&gt;
 &lt;w:WordDocument&gt;
  &lt;w:View&gt;Normal&lt;/w:View&gt;
  &lt;w:Zoom&gt;0&lt;/w:Zoom&gt;
  &lt;w:TrackMoves/&gt;
  &lt;w:TrackFormatting/&gt;
  &lt;w:PunctuationKerning/&gt;
  &lt;w:ValidateAgainstSchemas/&gt;
  &lt;w:SaveIfXMLInvalid&gt;false&lt;/w:SaveIfXMLInvalid&gt;
  &lt;w:IgnoreMixedContent&gt;false&lt;/w:IgnoreMixedContent&gt;
  &lt;w:AlwaysShowPlaceholderText&gt;false&lt;/w:AlwaysShowPlaceholderText&gt;
  &lt;w:DoNotPromoteQF/&gt;
  &lt;w:LidThemeOther&gt;EN-US&lt;/w:LidThemeOther&gt;
  &lt;w:LidThemeAsian&gt;X-NONE&lt;/w:LidThemeAsian&gt;
  &lt;w:LidThemeComplexScript&gt;ML&lt;/w:LidThemeComplexScript&gt;
  &lt;w:Compatibility&gt;
   &lt;w:BreakWrappedTables/&gt;
   &lt;w:SnapToGridInCell/&gt;
   &lt;w:WrapTextWithPunct/&gt;
   &lt;w:UseAsianBreakRules/&gt;
   &lt;w:DontGrowAutofit/&gt;
   &lt;w:SplitPgBreakAndParaMark/&gt;
   &lt;w:EnableOpenTypeKerning/&gt;
   &lt;w:DontFlipMirrorIndents/&gt;
   &lt;w:OverrideTableStyleHps/&gt;
  &lt;/w:Compatibility&gt;
  &lt;m:mathPr&gt;
   &lt;m:mathFont m:val=&quot;Cambria Math&quot;/&gt;
   &lt;m:brkBin m:val=&quot;before&quot;/&gt;
   &lt;m:brkBinSub m:val=&quot;&amp;#45;-&quot;/&gt;
   &lt;m:smallFrac m:val=&quot;off&quot;/&gt;
   &lt;m:dispDef/&gt;
   &lt;m:lMargin m:val=&quot;0&quot;/&gt;
   &lt;m:rMargin m:val=&quot;0&quot;/&gt;
   &lt;m:defJc m:val=&quot;centerGroup&quot;/&gt;
   &lt;m:wrapIndent m:val=&quot;1440&quot;/&gt;
   &lt;m:intLim m:val=&quot;subSup&quot;/&gt;
   &lt;m:naryLim m:val=&quot;undOvr&quot;/&gt;
  &lt;/m:mathPr&gt;&lt;/w:WordDocument&gt;
&lt;/xml&gt;&lt;![endif]--&gt;&lt;!--[if gte mso 9]&gt;&lt;xml&gt;
 &lt;w:LatentStyles DefLockedState=&quot;false&quot; DefUnhideWhenUsed=&quot;true&quot;
  DefSemiHidden=&quot;true&quot; DefQFormat=&quot;false&quot; DefPriority=&quot;99&quot;
  LatentStyleCount=&quot;267&quot;&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;0&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Normal&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;heading 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 7&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 8&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 9&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 7&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 8&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 9&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;35&quot; QFormat=&quot;true&quot; Name=&quot;caption&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;10&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Title&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;1&quot; Name=&quot;Default Paragraph Font&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;11&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Subtitle&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;22&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Strong&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;20&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Emphasis&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;59&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Table Grid&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; UnhideWhenUsed=&quot;false&quot; Name=&quot;Placeholder Text&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;1&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;No Spacing&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; UnhideWhenUsed=&quot;false&quot; Name=&quot;Revision&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;34&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;List Paragraph&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;29&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Quote&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;30&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Intense Quote&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;19&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Subtle Emphasis&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;21&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Intense Emphasis&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;31&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Subtle Reference&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;32&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Intense Reference&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;33&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Book Title&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;37&quot; Name=&quot;Bibliography&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; QFormat=&quot;true&quot; Name=&quot;TOC Heading&quot;/&gt;
 &lt;/w:LatentStyles&gt;
&lt;/xml&gt;&lt;![endif]--&gt;&lt;!--[if gte mso 10]&gt;
&lt;style&gt;
 /* Style Definitions */
 table.MsoNormalTable
 {mso-style-name:&quot;Table Normal&quot;;
 mso-tstyle-rowband-size:0;
 mso-tstyle-colband-size:0;
 mso-style-noshow:yes;
 mso-style-priority:99;
 mso-style-parent:&quot;&quot;;
 mso-padding-alt:0in 5.4pt 0in 5.4pt;
 mso-para-margin-top:0in;
 mso-para-margin-right:0in;
 mso-para-margin-bottom:10.0pt;
 mso-para-margin-left:0in;
 line-height:115%;
 mso-pagination:widow-orphan;
 font-size:11.0pt;
 font-family:&quot;Calibri&quot;,&quot;sans-serif&quot;;
 mso-ascii-font-family:Calibri;
 mso-ascii-theme-font:minor-latin;
 mso-hansi-font-family:Calibri;
 mso-hansi-theme-font:minor-latin;
 mso-bidi-language:AR-SA;}
&lt;/style&gt;
&lt;![endif]--&gt;

&lt;br /&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
1. Orbital Reconstruction after Repeat Orbital Exenteration
HIMIKA GUPTA*# , DEEPA NAIR 1 * ASST. PROFESSOR IN OPHTHALMOLOGY, MGM
UNIVERSITY,NAVI MUMBAI #OCULAR ONCOLOGIST, SPECTRA EYE CARE CLINIC, SECTOR 5
,BELAPUR,NAVI MUMBAI 1.ASST. PROFESSOR, TATA MEMORIAL CANCER CENTRE,MUMBAI&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
2. CASE • 8 month/Female • Exenterated for orbital teratoma
• Temporalis muscle flap reconstruction done • Eyelid skin lining • Recurrent
disease abutting the cavernous sinus • Wound infection&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
3. Intra operatively • Infected Lacrimal sac • No remnants
of temporalis muscle identified • Minimal CSF leak at apex • Complete tumour
resection • Unhealthy lid skin resected Options for exenteration defect
reconstruction  Lid skin  Granulate  Split skin graft  Temporalis muscle
Flap&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
4. Ideal reconstruction Cushion the exposed cavernous sinus
structures Plug the CSF leak Avoid infection Ensure defect is closed Avoid
daily dressings(infant) ?Adequate Vascularization Dermis Fat Graft&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
5. Post operative POD#7 POD#14POD#7 • Donor site healed • No
sloughing • No infection • No signs of uptake&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
6. POD # 70 - ‘Auto’ debridement Superficial layer of dermis
and fat did not ‘take’ and sloughed off 2.5 months post surgery, leaving behind
a defect covered with vascularized fat and healing skin epithelial margins&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
7. Healing defect • Placental extract • Collagen • Minimal
use of antibiotics&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
8. Dual action of DFG for exenteration Temporary biological
dressing till skin epithelialises (Subsequently sloughed off) + Live fat graft
Incorporated to provide volume and cushioning&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
9. Review of literature • Dermis Fat Graft on a vascular bed
of temporalis muscle # • Biological dressings for temporary wound closure.* #
Shore JW, Burks R, Leone CR Jr, McCord CD Jr. Dermis-fat graft for orbital
reconstruction after subtotal exenteration. Am J Ophthalmol. 1986 Aug
15;102(2):228-36. *May SR. The effects of biological wound dressings on the
healing process. Clin Mater. 1991;8(3-4):243-9.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
10. Conclusion • Reconstruction of repeat exenteration –
challenging • Exposed dura/Infancy , lack of eyelid skin or temporalis muscle
limited the choice of graft • Dermis fat graft acts as Dual action- temporary
biological dressing + soft tissue graft.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
11. Acknowledgement • Skull Base Clinic Team • Pediatric DMG
Team Tata Memorial Cancer Centre, Mumbai THANK YOU ! spectraeyeclinic@gmail.com
himika.gupta@gmail.com&lt;/div&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/6284582177236124812/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/orbital-reconstruction-after-repeat.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/6284582177236124812'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/6284582177236124812'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/orbital-reconstruction-after-repeat.html' title='Orbital Reconstruction After Repeat Orbital Exenteration'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-7015430367932331981</id><published>2020-04-17T16:00:00.000+05:30</published><updated>2020-04-17T16:00:10.769+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Benefits of Prosthetic Eye"/><title type='text'>Benefits of Prosthetic Eye</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;iframe width=&quot;853&quot; height=&quot;480&quot; src=&quot;https://www.youtube.com/embed/U1jJt4AyBuY&quot; frameborder=&quot;0&quot; allow=&quot;accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen&gt;&lt;/iframe&gt;
&lt;br /&gt;
&lt;br /&gt;SouthwesternEye&lt;br /&gt;Benefits of Prosthetic Eye&lt;br /&gt;by Southwestern Eye Center http://youtu.be/U1jJt4AyBuY&lt;br /&gt;&lt;br /&gt;One of the scariest and most traumatic things that can happen to anyone is losing an eye. But with the advancement of science, there is an option to help people who lose an eye.&lt;br /&gt;&lt;br /&gt;A prosthetic eye implant is usually recommended for individuals who have had an eye removed due to disease or damage. The prosthetic eye or &quot;fake eye&quot; cannot restore vision, but it can help enhance one&#39;s appearance. &lt;br /&gt;&lt;br /&gt;In this video, Southwestern Eye Center&#39;s Dr. Matthew Palmer, O.D., gives insights about prosthetic eyes. Watch this video to learn more about prosthetic eyes.&lt;br /&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/7015430367932331981/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/benefits-of-prosthetic-eye.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7015430367932331981'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7015430367932331981'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/benefits-of-prosthetic-eye.html' title='Benefits of Prosthetic Eye'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://img.youtube.com/vi/U1jJt4AyBuY/default.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-4990099159004758666</id><published>2020-04-17T13:15:00.002+05:30</published><updated>2020-04-17T13:15:38.028+05:30</updated><title type='text'>Alloplastic Materials </title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt; Benefits to using alloplastic 
materials, there is currently a strong interest in developing the ideal 
implant material which would possess the following characteristics: it 
should&amp;nbsp;&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (1) be chemically inert;&amp;nbsp;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (2) be incapable of producing 
hypersensitivity or a foreign body reaction;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (3) be easily contoured;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (4) retain stable shape over time (except when desired);&amp;nbsp;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (5) be 
noncarcinogenic;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (6) become ingrown or replaced by living tissue;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (7) be
 easy to remove and sterilize; and&amp;nbsp;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;&amp;nbsp; (8) not interfere with radiographic 
imaging.&amp;nbsp;&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;arial&amp;quot;;&quot;&gt;Despite much effort and ingenuity, creation of the ideal 
implant material has yet to be accomplished. However, various 
alloplastic materials are being used today in plastic and reconstructive
 procedures, and many of them have proven quite promising.&lt;/span&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/4990099159004758666/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/alloplastic-materials.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/4990099159004758666'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/4990099159004758666'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/alloplastic-materials.html' title='Alloplastic Materials '/><author><name>Celia Vinny</name><uri>http://www.blogger.com/profile/07138172099486501120</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-7186393032125892837</id><published>2020-04-17T13:14:00.002+05:30</published><updated>2020-04-17T13:14:38.277+05:30</updated><title type='text'>Patient resource</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;span style=&quot;font-family: &amp;quot;calibri&amp;quot; , &amp;quot;sans-serif&amp;quot;; font-size: 11.0pt; line-height: 115%;&quot;&gt;causes of eye loss&lt;br /&gt;
&lt;br /&gt;
Microphthalmia / Anophthalmia&lt;br /&gt;
&lt;br /&gt;
micropthalmia is a developmental disorder of the eye that literally&lt;br /&gt;
means small eye.One (Unilateral Microphthalmia) or both (Bilateral&lt;br /&gt;
Microphthalmia) eyes may be involved.Anophthalmia is the congenital&lt;br /&gt;
absence of one or both eyes.&lt;br /&gt;
&lt;br /&gt;
Retinoblastoma&lt;br /&gt;
&lt;br /&gt;
Retinoblastoma (Rb) is a rapidly developing cancer which develops in&lt;br /&gt;
the cells of retina, the light detecting tissue of the eye.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;!--[if !supportLineBreakNewLine]--&gt;&lt;br /&gt;
&lt;!--[endif]--&gt;&lt;/span&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/7186393032125892837/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/patient-resource.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7186393032125892837'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7186393032125892837'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/patient-resource.html' title='Patient resource'/><author><name>Celia Vinny</name><uri>http://www.blogger.com/profile/07138172099486501120</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-862954314479041337</id><published>2020-04-17T13:14:00.000+05:30</published><updated>2020-04-17T13:14:22.404+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Chinmaya Ocular prosthetics"/><category scheme="http://www.blogger.com/atom/ns#" term="India  Ocularists in India"/><category scheme="http://www.blogger.com/atom/ns#" term="New Delhi"/><title type='text'>Chinmaya Ocular prosthetics, New Delhi</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
&lt;b&gt;&lt;span class=&quot;Apple-style-span&quot; style=&quot;color: #cc0000;&quot;&gt;Chinmaya Ocular prosthetics, New Delhi&lt;/span&gt;&lt;/b&gt;&lt;/div&gt;
&lt;div&gt;
&lt;b&gt;&lt;span class=&quot;Apple-style-span&quot; style=&quot;color: #cc0000;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/b&gt;&lt;/div&gt;
&lt;div&gt;
Chinmaya Ocular prosthetics, New Delhi&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
Postal Address :&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
Chinmaya Prosthetics Center,&lt;/div&gt;
&lt;div&gt;
28, Bhera Enclave, Outer Ring Road,&lt;/div&gt;
&lt;div&gt;
Paschim Vihar,&lt;/div&gt;
&lt;div&gt;
New Delhi,&lt;/div&gt;
&lt;div&gt;
India.&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
PIN : 110087&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
Phone Number : &lt;span class=&quot;Apple-tab-span&quot; style=&quot;white-space: pre;&quot;&gt; &lt;/span&gt;91-011-25274842&lt;/div&gt;
&lt;div&gt;
&lt;span class=&quot;Apple-tab-span&quot; style=&quot;white-space: pre;&quot;&gt; &lt;/span&gt;91-011-25282864&lt;/div&gt;
&lt;div&gt;
Office Hours: &lt;span class=&quot;Apple-tab-span&quot; style=&quot;white-space: pre;&quot;&gt; &lt;/span&gt;Monday – Saturday&lt;/div&gt;
&lt;div&gt;
&lt;span class=&quot;Apple-tab-span&quot; style=&quot;white-space: pre;&quot;&gt; &lt;/span&gt;10 am – 6 pm&lt;/div&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/862954314479041337/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/chinmaya-ocular-prosthetics-new-delhi.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/862954314479041337'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/862954314479041337'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/chinmaya-ocular-prosthetics-new-delhi.html' title='Chinmaya Ocular prosthetics, New Delhi'/><author><name>Celia Vinny</name><uri>http://www.blogger.com/profile/07138172099486501120</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-6119758053925088795</id><published>2020-04-17T13:13:00.004+05:30</published><updated>2020-04-17T13:13:58.437+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Artificial Eye"/><title type='text'>artificial eye abstract pdf</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
In the present scenario, where over millions of citizens are affected by visual anomalities, it was with a challenge that this project came into being. This page contains Artificial Eye Seminar and PPT with pdf report. Artificial Eye Seminar Report with ppt and pdf. Human Eye Conditions&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Topics&amp;nbsp; related to artificial eye abstract pdf&lt;/h4&gt;
artificial eye seminar documentation&lt;br /&gt;artificial eye technical seminar report&lt;br /&gt;disadvantages of artificial eye&lt;br /&gt;literature survey of artificial eye&lt;br /&gt;artificial eye introduction&lt;br /&gt;references for artificial eye&lt;br /&gt;bionic eye technology&lt;br /&gt;how to make artificial eye&lt;br /&gt;artificial retina seminar report pdf&lt;br /&gt;123seminarsonly&lt;br /&gt;eye prosthesis ppt&lt;br /&gt;bionic eye pdf&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/6119758053925088795/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-abstract-pdf.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/6119758053925088795'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/6119758053925088795'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-abstract-pdf.html' title='artificial eye abstract pdf'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-7918240024540969488</id><published>2020-04-17T09:00:00.000+05:30</published><updated>2020-04-17T09:00:06.049+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="eye prosthesis"/><title type='text'>Eye Prosthesis Still the Best Artificial Eye Solution</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;iframe width=&quot;853&quot; height=&quot;480&quot; src=&quot;https://www.youtube.com/embed/SoGeDOddYdo&quot; frameborder=&quot;0&quot; allow=&quot;accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen&gt;&lt;/iframe&gt;
&lt;br /&gt;
Scientists say bionic eyes are not too far away, but, until they become widely available, many people around the world will have to continue living with prosthetic eyes. Still, highly trained technicians called ocularists can manufacture prosthetic eyes hardly distinguishable from normal ones, making the lives of their patients much more pleasant. VOA&#39;s George Putic reports.&lt;br /&gt;&lt;br /&gt;Originally published at - https://www.voanews.com/a/eye-prosthe...&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/7918240024540969488/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/eye-prosthesis-still-best-artificial.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7918240024540969488'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7918240024540969488'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/eye-prosthesis-still-best-artificial.html' title='Eye Prosthesis Still the Best Artificial Eye Solution'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://img.youtube.com/vi/SoGeDOddYdo/default.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-5678693665382757726</id><published>2020-04-16T17:00:00.000+05:30</published><updated>2020-04-16T17:00:00.872+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Artificial eye fitting"/><category scheme="http://www.blogger.com/atom/ns#" term="eye loss"/><category scheme="http://www.blogger.com/atom/ns#" term="maintenance"/><title type='text'>Coping with eye loss - 6. Artificial eye fitting and maintenance</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;iframe width=&quot;640&quot; height=&quot;480&quot; src=&quot;https://www.youtube.com/embed/c6f9YXaSXe0&quot; frameborder=&quot;0&quot; allow=&quot;accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen&gt;&lt;/iframe&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/5678693665382757726/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/coping-with-eye-loss-6-artificial-eye.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5678693665382757726'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5678693665382757726'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/coping-with-eye-loss-6-artificial-eye.html' title='Coping with eye loss - 6. Artificial eye fitting and maintenance'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://img.youtube.com/vi/c6f9YXaSXe0/default.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-1792669333713024171</id><published>2020-04-16T09:00:00.000+05:30</published><updated>2020-04-16T09:00:12.835+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="prosthetic eyes"/><title type='text'>Changing lives with prosthetic eyes</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;iframe allow=&quot;accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen=&quot;&quot; frameborder=&quot;0&quot; height=&quot;480&quot; src=&quot;https://www.youtube.com/embed/-FvqfRayk4A&quot; width=&quot;853&quot;&gt;&lt;/iframe&gt;

&lt;br /&gt;
&lt;br /&gt;
An Australian prosthetic eye-maker is keen to share her expertise and improve the lives of patients in developing countries. The highly specialized skill is performed by just a dozen professionals throughout Australia. The prosthetic eye gives the patient comfort and confidence, just like &#39;a normal eye.&#39;&lt;br /&gt;
&lt;br /&gt;
Subscribe to us on YouTube: https://goo.gl/lP12gA&lt;br /&gt;
&lt;br /&gt;
Download our APP on Apple Store (iOS): https://itunes.apple.com/us/app/cctvn...&lt;br /&gt;
&lt;br /&gt;
Download our APP on Google Play (Android): https://play.google.com/store/apps/de...&lt;br /&gt;
&lt;br /&gt;
Follow us on:&lt;br /&gt;
&lt;br /&gt;
Facebook: https://www.facebook.com/ChinaGlobalT...&lt;br /&gt;
Instagram: https://www.instagram.com/cgtn/?hl=zh-cn&lt;br /&gt;
Twitter: https://twitter.com/CGTNOfficial&lt;br /&gt;
Pinterest: https://www.pinterest.com/CGTNOfficial/&lt;br /&gt;
Tumblr: http://cctvnews.tumblr.com/&lt;br /&gt;
Weibo: http://weibo.com/cctvnewsbeijing&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/1792669333713024171/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/changing-lives-with-prosthetic-eyes.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/1792669333713024171'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/1792669333713024171'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/changing-lives-with-prosthetic-eyes.html' title='Changing lives with prosthetic eyes'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://img.youtube.com/vi/-FvqfRayk4A/default.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-7433773918245534234</id><published>2020-04-15T23:37:00.003+05:30</published><updated>2020-04-15T23:37:28.931+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Artificial eye abstract"/><title type='text'>Artificial Eye Abstract</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
The history of the artificial eye, from antiquity to the present, is described. Around the beginning of the nineteenth century, glass eyes replaced the earlier metal ones--not always well tolerated. In 1835, cryolite glass was used instead of lead glass; to this day it remains the lightest and most desirable substance for making artificial eyes.&lt;br /&gt;&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Topics related to artificial eye abstract&lt;/h4&gt;
artificial eye report pdf&lt;br /&gt;artificial eye seminar documentation&lt;br /&gt;artificial eye technical seminar report&lt;br /&gt;disadvantages of artificial eye&lt;br /&gt;literature survey of artificial eye&lt;br /&gt;how artificial eye works&lt;br /&gt;eye prosthesis ppt&lt;br /&gt;bionic eye technology&lt;br /&gt;artificial vision using embedded system&lt;br /&gt;artificial eye introduction&lt;br /&gt;seminar topics&lt;br /&gt;references for artificial eye&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/7433773918245534234/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-abstract.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7433773918245534234'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7433773918245534234'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-abstract.html' title='Artificial Eye Abstract'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-5802745913360482815</id><published>2020-04-13T19:51:00.004+05:30</published><updated>2020-04-13T19:51:53.762+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="eye prosthesis"/><title type='text'>  Eye Prosthesis Presentation </title><content type='html'>
&lt;iframe src=&quot;//www.slideshare.net/slideshow/embed_code/key/brLlUicVMGbuwv&quot; width=&quot;595&quot; height=&quot;485&quot; frameborder=&quot;0&quot; marginwidth=&quot;0&quot; marginheight=&quot;0&quot; scrolling=&quot;no&quot; style=&quot;border:1px solid #CCC; border-width:1px; margin-bottom:5px; max-width: 100%;&quot; allowfullscreen&gt; &lt;/iframe&gt; &lt;div style=&quot;margin-bottom:5px&quot;&gt; &lt;strong&gt; &lt;a href=&quot;//www.slideshare.net/gudurivineeth/eye-prosthesis&quot; title=&quot;Eye Prosthesis&quot; target=&quot;_blank&quot;&gt;Eye Prosthesis&lt;/a&gt; &lt;/strong&gt; from &lt;strong&gt;&lt;a href=&quot;https://www.slideshare.net/gudurivineeth&quot; target=&quot;_blank&quot;&gt;guduri vineeth&lt;/a&gt;&lt;/strong&gt; &lt;/div&gt;

&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;1. By G. Vineeth III MDS Eye Prosthesis&lt;br /&gt;2. Contents • Introduction • History • Types of eye prostheses • Patient evaluation • Treatment planning – Techniques of impression – Techniques of fabrication – Methods of retention – Maintenance • Complications • Conclusion • References&lt;br /&gt;3. Introduction Defects of the eye Marian Pauly MS, DNB, Giridhar A, MS, Iby P. Varghese. Ocular prosthesis. Kerala Journal of Opthalmology 2011; 23(4); 339-41 Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;4. History • Indians – 5600 BC • Iran – 2900 BC • Egyptians – 500 BC • Europeans – 1500 AD • Materials used Wikipedia: Internet Sanjayagouda B. Patil, Roseline Meshramkar, B. H. Naveen and N. P. Patil. Ocular prosthesis: a brief review and fabrication of an ocular prosthesis for a geriatric patient. Gerodontology 2008; 25: 57–62&lt;br /&gt;5. Types of Eye prostheses Conformers Ocular prosthesis Orbital Prosthesis Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000. Sykes, Essop and Veres. Use of custom made conformers in the treatment of ocular defects. J Prosthet Dent 1999;82:362-5&lt;br /&gt;6. Patient evaluation • For ocular defects – Prognosis estimation – Physical evaluation – Muscular evaluation – Desires and expectations of the patient – Counselling the patient • For orbital defects – Pre-operative evaluation better than post-operative – CT, MRI, FNAC useful. Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000. E. L. DaBreo, and David E. Schuller. Surgical and prosthetic considerations in the management of orbital tumors. J Prosthet Dent 1992; 67(1); 106-12&lt;br /&gt;7. Treatment planning • Patient centered model • Multidisciplinary • Initial visit – determine treatment needs and confirm them with patient • Discuss these needs with team members – process and outcome • All the pre-requisites should be planned • Patient confirms regarding the procedure after consultation • Signed consent • Start treatment Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;8. Treatment planning - steps • Planning Retention • Moulage impression and working cast fabriction • Pattern fabrication and try-in • Craniofacial implants placement followed by impression • Cast modification • Pattern try-in • Processing • Insertion and maintenance&lt;br /&gt;9. Methods of retention • Extra-ocular muscles • Adhesives • Mechanical : Eyeglasses/Spectacles • Magnets • Implants: Bar and clip attachments or magnetic attachments Sameera R Shaikh, Pravinkumar G Patil, Santosh Puri. A modified technique for retention of orbital prosthesis. Indian Journal of Dental Research 2011, 22(6), 863-65 Neeraj Khatkar et al. Magnets in prosthetic dentistry. Journal of Dental Sciences &amp;amp; Oral Rehabilitation 2013; 12-13.&lt;br /&gt;10. Modified retention Sameera R Shaikh, Pravinkumar G Patil, Santosh Puri. A modified technique for retention of orbital prosthesis. Indian Journal of Dental Research 2011, 22(6), 863-65&lt;br /&gt;11. Modified retention Gunjan Pruthi, Veena Jain &amp;amp; Swati Sikka. A Novel Method for Retention of an Orbital Prosthesis in a Case with Continuous Maxillary and Orbital Defect. J Ind Prosthodont Soc 2010; 10(2):132–136&lt;br /&gt;12. http://www.ocularist.org/resources_surgical_procedures.asp; American society of ocularists: Internet&lt;br /&gt;13. Techniques of impression • Stock tray impression technique Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;14. Techniques of impression • External tray impression technique Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;15. Techniques of impression Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;16. Techniques of impression 3 D Laser Scanning 3 D Optical Scanning 3 D Image A. M. Bhat. Recent advances in the modelling of extraoral defects. J Ind Prosthodont Soc 2005; 5(4); 180-184&lt;br /&gt;17. Techniques of fabrication • Paper Iris Disk technique Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;18. Techniques of fabrication • Black Iris Disk technique Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;19. Techniques of fabrication Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000.&lt;br /&gt;20. Color matching Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000. Armamentarium Color formulation and mixing machine Spectrophotometer&lt;br /&gt;21. Rapid prototyping Ing Andreas Gebhardt. Textbook; Short course on rapid prototyping. 2010&lt;br /&gt;22. Procedure&lt;br /&gt;23. Procedure&lt;br /&gt;24. Recent trend – Bionic Eye&lt;br /&gt;25. Maintenence • Adjustment to the prosthesis • Period of wear • Removal and replacement • Cleaning • Recall G. R. Parr, B. M. Goldman, and A. 0. Rahn. Postinsertion care of the ocular prosthesis. J Prosthet Dent 1983; 49(2); 220-224&lt;br /&gt;26. Complications • Tissue irritation • Inadequate peri-orbital support • Recurrence of tumor • Implant exposure • Conjunctival thinning • Discharge • Pyogenic granuloma formation (excess healing tissue formation), • Rarely persistent pain or discomfort&lt;br /&gt;27. Conclusion To meet challenges and surpass them is the basic means survival of the fittest. With efficiency and uncompromising efforts, this task becomes easier.&lt;br /&gt;28. References • Marian Pauly MS, DNB, Giridhar A, MS, Iby P. Varghese. Ocular prosthesis. Kerala Journal of Opthalmology 2011; 23(4); 339-41 • Thomas D Taylor, editor. Clinical maxillofacial prosthetics. Quintessence Publishing Co; 2000. • E. L. DaBreo, and David E. Schuller. Surgical and prosthetic considerations in the management of orbital tumors. J Prosthet Dent 1992; 67(1); 106-12. • Sameera R Shaikh, Pravinkumar G Patil, Santosh Puri. A modified technique for retention of orbital prosthesis. Indian Journal of Dental Research 2011, 22(6), 863-65. • G. R. Parr, B. M. Goldman, and A. 0. Rahn. Postinsertion care of the ocular prosthesis. J Prosthet Dent 1983; 49(2); 220-224 • Sykes, Essop and Veres. Use of custom made conformers in the treatment of ocular defects. J Prosthet Dent 1999;82:362-5&lt;br /&gt;29. References • Sanjayagouda B. Patil, Roseline Meshramkar, B. H. Naveen and N. P. Patil. Ocular prosthesis: a brief review and fabrication of an ocular prosthesis for a geriatric patient. Gerodontology 2008; 25: 57–62 • Wikipedia: Internet • Neeraj Khatkar et al. Magnets in prosthetic dentistry. Journal of Dental Sciences &amp;amp; Oral Rehabilitation 2013; 12-13. • Gunjan Pruthi, Veena Jain &amp;amp; Swati Sikka. A Novel Method for Retention of an Orbital Prosthesis in a Case with Continuous Maxillary and Orbital Defect. J Ind Prosthodont Soc 2010; 10(2):132–136 • http://www.ocularist.org/resources_surgical_procedures.asp; American society of ocularists: Internet • A. M. Bhat. Recent advances in the modelling of extraoral defects. J Ind Prosthodont Soc 2005; 5(4); 180-184 • Ing Andreas Gebhardt. Textbook; Short course on rapid prototyping. 2010&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/5802745913360482815/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/eye-prosthesis-presentation.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5802745913360482815'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5802745913360482815'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/eye-prosthesis-presentation.html' title='  Eye Prosthesis Presentation '/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-5403080657055989012</id><published>2020-04-13T19:45:00.001+05:30</published><updated>2020-04-13T19:45:09.618+05:30</updated><title type='text'>artificial eye lashes</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
The best part about false eyelashes is that they come in different colors. If you have naturally black lashes, you can choose black ones available in several brands&lt;br /&gt;
&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Topics Related to artificial eye lashes&lt;/h4&gt;
How do you fix false eyelashes?&lt;br /&gt;&lt;br /&gt;How long can you keep on false eyelashes?&lt;br /&gt;&lt;br /&gt;Which fake lashes are the best?&lt;br /&gt;&lt;br /&gt;What is the cost of false eyelashes?&lt;br /&gt;&lt;br /&gt;eye lashes price&lt;br /&gt;&lt;br /&gt;eyelashes price in amazon&lt;br /&gt;&lt;br /&gt;how to put on false eyelashes for beginners&lt;br /&gt;&lt;br /&gt;eyelashes meaning&lt;br /&gt;&lt;br /&gt;easiest way to put on fake eyelashes&lt;br /&gt;&lt;br /&gt;eyelashes growth&lt;br /&gt;&lt;br /&gt;mac eyelashes price&lt;br /&gt;&lt;br /&gt;do i put mascara on before fake lashes&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/5403080657055989012/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-lashes.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5403080657055989012'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/5403080657055989012'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-lashes.html' title='artificial eye lashes'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-3385641375932701268</id><published>2020-04-11T14:13:00.000+05:30</published><updated>2020-04-11T14:13:01.327+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Ocular Prosthesis"/><title type='text'>Ocular prosthesis Presentation</title><content type='html'>
&lt;iframe src=&quot;//www.slideshare.net/slideshow/embed_code/key/vgpVudK5VssnBp&quot; width=&quot;595&quot; height=&quot;485&quot; frameborder=&quot;0&quot; marginwidth=&quot;0&quot; marginheight=&quot;0&quot; scrolling=&quot;no&quot; style=&quot;border:1px solid #CCC; border-width:1px; margin-bottom:5px; max-width: 100%;&quot; allowfullscreen&gt; &lt;/iframe&gt; &lt;div style=&quot;margin-bottom:5px&quot;&gt; &lt;strong&gt; &lt;a href=&quot;//www.slideshare.net/sailichandavarkar/ocular-prosthesis-1&quot; title=&quot;Ocular prosthesis 1&quot; target=&quot;_blank&quot;&gt;Ocular prosthesis 1&lt;/a&gt; &lt;/strong&gt; from &lt;strong&gt;&lt;a href=&quot;//www.slideshare.net/sailichandavarkar&quot; target=&quot;_blank&quot;&gt;Saili Chandavarkar&lt;/a&gt;&lt;/strong&gt; &lt;/div&gt;

&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;

&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
Ocular prosthesis &lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
1. The eye was a symbol of life to the ancient world,
particularly in Egypt, where bronze and precious stone eyes were placed on the
deceased. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The Romans decorated statues
with artificial eyes made of silver. history&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
2. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Ambrose Paré
(1510-1590), a famous French surgeon, was the first to describe the use of
artificial eyes to fit an eye socket. These pieces were made of gold and
silver.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
3. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Enamel prostheses
(1820s-1890s) were attractive but were expensive and not very durable. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The introduction of cryolite glass, made of
arsenic oxide and cryolite from sodium-aluminum fluoride (Na6A2F12), produced a
grayish- white color suitable for a prosthetic eye.German craftsmen are
credited with this invention in 1835.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
4. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;To make these
glass eyes, a tube of glass was heated on one end until the form of a ball was
obtained. Various colors of glass were used like paintbrushes to imitate the
natural color of the eye &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The glass art
form flourished in France and Germany where fabricating secrets were handed
down from one generation to the next.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
5. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The town of
Lausche, Germany, had a particularly rich history in both decorative (doll
eyes, Christmas ornaments) and prosthetic arts. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;In the 19th century, German craftsmen
(&quot;ocularists&quot;) began to tour the United States and other parts of the
world, fabricated eyes and fit them to patients.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
6. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Stock eyes (or
pre-made eyes) were also utilized. An &quot;eye doctor&quot; might keep
hundreds of glass stock eyes in cabinets, and would fit patients with the best
eye right out of the drawer.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
7. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;In the United
States, eyes continued to be made of glass until the onset of World War II,
when German goods were limited and German glass blowers no longer toured the
United States. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The United States
military, along with a few private practitioners, developed a technique of
fabricating prostheses using oil pigments and plastics. Since World War II,
plastic has become the preferred material for the artificial eye in the United
States.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
8. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;By the mid-1940s,
glass eyes were being replaced by plastic counterparts. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;In Virginia, this was led by Joseph Galeski
(of Richmond, Virginia), &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Although
American Optical and several military hospitals started to experiment and
dispense plastic artificial eyes.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
9. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;An ocular implant
replaces the lost volume of the natural eye. The first account of placing an
implant in the socket, following enucleation, was in 1841. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Implants have been made of many different
materials, shapes, and types throughout the years. It also helps the artificial
eye to have some degree of movement&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
10. Naval dental school (1940), tested the use of acrylic
resin in fabricating a custom ocular prosthesis. Unlike a glass eye, an acrylic
eye was easy to fit and adjust, unbreakable, inert to ocular fluids, esthetical
good, longer lasting and easier to fabricate&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
11. Surgical procedures in the removal of an eye are
classified into three categories Evisceration- Removal of the contents of the
globe, but leaving the sclera and sometimes the cornea in place. Because the
extra-ocular muscles are left intact, good mobility of the prosthesis is
usually possible Enucleation- Removal of the eyeball itself Exenteration-
Removal of the entire contents of the orbit, including the extraocular muscles&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
12. Stock ocular prosthesis &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Stock acrylic resin eyes are supplied in three
basic shapes: oval, standard and three- cornered. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Each shape has three sizes: small, medium and
large, and they may be prepared for the right or the left eye.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
13. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The irises are
produced in three basic colours: brown, hazel and blue, and the individual
colours have been formulated so that they have some elasticity and overlapping
quality in matching effects. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The scleral
colours are also varied.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
14. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;One basic size of
iris (11.5 mm) is used, and it has a pupil opening of 3.5 mm. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Where possible, the stock eye should be made
to duplicate as closely as possible the superior fit and aesthetics of the
custom eye.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
15. impressions Dental impression materials such as
impression compound, dental waxes, irreversible hydrocolloids ,tissue conditioners
and elastomeric materials have been successfully used to register the
topography of the eye socket&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
16. Stock tray impression technique: • An impression is made
of the ocular defect using a disposable syringe, stock ocular trays and
irreversible hydrocolloid. •Stock acrylic resin impression trays available in
different sizes for ophthalmic impressions •Trays have a hollow handle which
accomodates an impression syringe&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
17. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;During the
procedure ,the patient should be seated in an upright position with the head
tilted backward at app 450 This position allows the natural positioning of the
palpebrae and surrounding tissue relative to the force of gravity.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
18. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The tray should
be placed into the defect to determine the proper orientation and fit without
overextension. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The tray is then removed
and the impression material is loaded in the syringe and sufficient material is
ejected to fill the concavity of the tray.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
19. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Ophthalmic
irreversible hydroclloid is mixed in a 30 ml medicine cup –app 5 ml of powder
to 5 cc of room temp water. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Alginate –
warm ,runny mix flow easily not distort the fatty tissues in the socket&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
20. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The tray is
reinserted and sufficient material is injected to elevate the lid contours
similar to the normal side. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;once filled
the patient is directed to move their eyes both up and done. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After the impression sets the assembly is
removed and examined for defects and voids.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
21. L. M. Sykes,Essop, Veres(J Prosthet Dent 1999;82:362-5.)
&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;described a procedure for fabricating
acrylic resin ocular custom-made conformers to maintain socketsize and contour.
&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;These custom-made ocular conformers act
as an interim measure and as valuable diagnostic indicators of problems
experienced by the patients..&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
22. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;While stock
conformers merely maintain the socket size and prevent scar tissue
contractures, the custom-made conformers can also be used to enlarge
unfavorably small sockets, stimulate eyelid movement, aid hygiene, help the
clinician develop the final shape for the definitive prosthesis, and reduce the
amount of postinsertion adjustments needed.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
23. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;If further
surgery is needed to deepen the socket bed or alter the eyelids, the socket is
enhanced by using the conformer as a surgical stent to maintain the mucosal
grafts in position and support the fornices.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
24. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Early settling
and sinking occurs with most patients, so that modifications to their
conformers are required to maintain an esthetic appearance and adequate eyelid
support.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
25. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;These advantages
and the ease of fabrication make custom-made conformers a viable initial
treatment option in patients with ocular defects&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
26. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The presence of
the custom-made conformer and its close approximation to the tissues in the
socket, stimulates the eyelid muscles to move, thus,exercising them and
preventing disuse atrophy. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Stock
conformers lack a close fit and therefore cannot stimulate eyelid movement&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
27. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Beumer et al
advocated placing a plastic stock conformer immediately into the socket to fit
the contours of the cavity and to fill the depths of the fornices. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;These were to be left in place while healing
occurs to reduce edema and to maintain the socket contours for the definitive
prosthesis&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
28. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Anesthetize the
socket with 1 or 2 drops of topical anesthetic &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Select an ocular special tray of the
appropriate size and try it into the socket to verify the fit.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
29. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;If the special
tray is not available, a tray can be fabricated at the chairside by heating a
small piece of modeling compound and adapting it to the area around the eye or
around a small rubber ball.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
30. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This should be
kept as thin as possible [2 to 3 mm].) &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Place a small tube in the center of the
compound and lute it into position with sticky wax. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The addition of a few small holes in the wax
aids retention of the impression material.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
31. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Hydrocolloid
material is mixed to a runny consistency by adding 1.5 parts warm water to 1
part powder. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Inject the hydrocolloid
down the tube into the socket under slight pressure while supporting the tray
in position, then allow the impression to set.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
32. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Remove the
impression and use it to pour a 2- piece split cast mold that is used to
fabricate the acrylic resin conformer. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once fabricated, the conformer can be fitted
immediately and adjusted at the chairside where needed, thus not allowing time
for the socket to shrink and scar tissues to contract.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
33. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Dismiss the
patient with instructions to wear the conformer continuously and only to be
removed for cleaning. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Severe pain or
discomfort must be reported immediately to ensure that necessary adjustments can
be made.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
34. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once the
clinician and patient are satisfied with the size and conformity of the
conformer, and the socket is well healed and dimensionally stable, a
conventional, definitive ocular prosthesis can be manufactured. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A duplicate of the modified conformer in wax
can be used as a template for the definitive prosthesis&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
35. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Alginate
impression material is expressed into the defect using a disposable syringe. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Next a perforated acrylic resin tray is loaded
and placed over the defect. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The impression
is first recovered from the lower, shallower sulcus first, then rotated out of
the deeper, upper sulcus. 38 External tray impression technique(Taylor)&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
36. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The impression is
boxed and poured in the dental stone up to the height of contour of the
impression. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A separating agent is placed
and the reminder of the impression is poured&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
37. Engelmier.R.L.Autoclavable custom made metal impression
trays to improve infection control.JPD 1987;58:121-2 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Has suggested casting a set of stock trays in
ticonium which is a non precious,removable partial denture alloy (Ticonium Co
,Albany,NY) which can be sterilized in an autoclave for reuse &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The impression material of choice is
ophthalmic alginate(Ophthalmic Moldite)&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
38. Ow,Amrith.Use of a tissue conditioner material to modify
a stock ocular prosthesis.JPD 1997;78:218-22 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Advocated the use of tissue conditioners as a
reline material because of its bio compatibilty and ease of manipulation. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Stock acrylic resin prosthesis is selected and
is modified by trimming its periphery to fit the eye socket
Visogel(Dentsply,England) is added and inserted for 20 mins.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
39. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Excess material
is removed and the ocular prosthesis is worn for 24-48 hrs &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;If the esthetics and adaptation are acceptable
,the prosthesis is relined with heat cure resin.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
40. Smith R M.Relining an ocular prosthesis-A case
report.JPD 1995;4:160-3 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Described a
reline procedure for an existing ocular prosthesis &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The ocular prosthesis is reduced in size until
it fit comfortably in the socket. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Melted
base plate wax is added to the borders until the ocular prosthesis is
positioned properly&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
41. Borders of modified prosthesis are shaped with baseplate
wax until proper gaze is establishcd&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
42. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The lid contours
and gaze were assessed and wax carved or added until the position of the ocular
prosthesis was satisfactory in all dimensions&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
43. Ocular prosthesis in place after borders are adjusted,
and gaze is established.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
44. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A thin layer of
Korrecta wax No.4 is added to the intaglio surface and the borders &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The prosthesis is then dipped into 123 0 F
water bath,inserted and left for 5 mins&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
45. Ocular prosthesis showing reline impression made with
Korecta-wax&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
46. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;During this time,
the patient was directed to take the prosthesis through a full range of motion.
&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The ocular prosthesis was removed,
inspected for coverage, and wax added in deficient areas or the excess removed
as indicated.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
47. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The borders and
intaglio surface were covered completely by the Korecta-wax. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;If there were any show throughs, the underlying
surface was relieved and covered with more wax. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Again, the prosthesis was placed and worn for
5 minutes&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
48. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once the
dimensions are corrected kept in the patients eyes for 30 mins while he moved
it intermittently in all directions &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A
laboratory reline procedure is then performed .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
49. Ocular prosthesis relined with Crystal Clear acqlic
resin.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
50. Impression With Custom Ocular Tray Miller suggested that
a custom ocular tray is necessary in certain situations. For example, the
anophthalmic socket could be highly irregular or stock trays may not be
available. Miller BJ: Custom ocular impression trays. J Facial SomatoProsthet
1996;2:109-113&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
51. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Miller’s method
involves attaching a solid suction rod to the patient’s existing prosthesis,
conformer, or wax shell and investing it in an alginate mold. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After the alginate sets, the prosthesis,
conformer, or wax is removed and replaced with clear acrylic resin.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
52. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Perforations are
made in the resulting tray, and a tunnel is cut into the stem through which
impression material can be delivered. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;An
impression is made using injected alginate.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
53. Mark F. Mathews, DDS, Rick M. Smith, DDS, Alan J.
Sutton, DDS,and Ron Hudson .The Ocular Impression: A Review of the Literature
and Presentation of an lternate Technique .JPD December 2000, Volume 9, Number
4 1. The patient’s existing prosthesis or conformer was disinfected and lightly
lubricated&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
54. 2. Medicine cup was filled with quick set stone
(Whip-Mix Blue Mounting Stone; Whip- MixCorporation, Louisville,KY), and the
tissue side of the prosthesis was invested till the height of contour.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
55. 3. When set, the edges of the stone cast were notched. A
small amount of PVS putty (Reprosil Putty; DentsplyInternational Inc, Milford,
DE),was mixed and was adapted over the top of the prosthesis and into the
notched indices. Putty cope,was removed and a large, beveled sprue hole was cut
into its center and a small vent to the side.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
56. 4. The prosthesis were removed from the mold, The stone
surface was lubricated (Liquid Tin Foil Substitute; Robert B.Scott, Inc, Tampa,
FL), and the putty cope was replaced.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
57. 5.Chemical-cure polymethylmethacrylate (Great Lakes Co,
Chicago, IL),was mixed and poured into the mold .The assembly was placed in a
pressure pot for 20 minutes at 25 psi.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
58. 6.The acrylic resin tray was removed, trimed and thined
as needed. The tray was perforated approximate at pupil location with a 3- to
4-mm diameter hole. Multiple perforations were placed over the remainder of the
surface. The custom tray was then polished .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
59. The tray was repolished, and checked for rough spots.
Tray was checked for overextension and proper orientation. Now the barrel of
the 5-mL syringe was attached to the injection tube.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
60. 3 teaspoons water and 1 tablespoon of ophthalmic
alginate impression material was mixed(Robert B. Scott, Inc), and back loaded
in the syringe. Tray was seated and the alginate was injected. After the
alginate impression material was set, the impression was removed and was
checked for for acceptability&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
61. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;When set, the
alginate mold was removed with impression from the cup.The alginate mold was
partially sectioned,and the original impression was retrieved. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The different mixes of alginate will not adhere
to each other. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The second alginate
impression becomes a mold to form the wax blank. The alginate mold is poured in
the cup,with ivory wax (40/40 Ivory Wax; MDLDental Products Inc, Seattle, WA)
through the sprue hole created by the syringe tip.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
62. Upon cooling,the impression is removed from the cup to
retrieve the wax blan.The sprue is cut off, The wax trial ocular prosthesis is
shaped and polished. Try in of the wax trial prosthesis is done to assess fit,
contour, and comfort. The iris button is added to the pattern, and then it is
processed.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
63. Formulation of the cast &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Imp poured in two sections using a 30 ml cup
filled halfway with dental stone .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
64. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;D.stone is added
to the post.surface of the impression and then placed into the cup upto the ant
of the postr edge of the imp and allowed to set . &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;2 keyways are made ,1 each adjacent to the
region of the nasal and temporal canthus.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
65. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Stone is coated
with a seperating medium [tin foil substitute] allowed to dry. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Second half of the mold is poured with dental
stone leaving a funnel shaped hole around the stem of the tray .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
66. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The hole used as
a funnel to fill the mold with molten wax . &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After the d.stone has set ,2 halves of the
mold are separated and the imp material is removed .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
67. Wax pattern: &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The
melted wax is then poured through the funnel shaped hole and into the assembled
mold. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Soaking the mold in water for a
few minutes prior to filling it with molten wax will prevent the wax from
adhering to the stone.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
68. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After the wax has
cooled, the wax pattern is recovered. Once the wax pattern has been smoothed
and polished, it is ready to be tried in the eye socket.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
69. To insert the wax pattern, the upper lid is lifted, and
the superior edge of the pattern is placed behind the lid and gently pushed
upward.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
70. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;While drawing the
lower lid down, the inferior border of the pattern is seated in the inferior
fornix, and then the lower lid is released. The eye contours are checked.
Pressure points and areas of discomfort is noted and relieved&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
71. Iris position &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The
iris should be bilaterally symmetrical; therefore, accurate placement of the
custom- painted iris disk on the scleral wax pattern is critical. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The gaze and the position of the iris is
determined .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
72. McArthur RD: Aids for positioning prosthetic eyes in
orbital prosthesis. J Prosthet Dent 1977;37:320-326 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;McArthur described methods for positioning the
artificial eye in the orbital prosthesis using an ocular locator and fixed
caliper. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This determined the placement
of the prosthetic eye in the mediolateral and supero-inferior planes.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
73. Benson P: The fitting and fabrication of a custom resin
artificial eye. J Prosthet Dent 1977;38:532-539 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Benson suggested a method for fabricating
aBenson suggested a method for fabricating a custom-made acrylic resin ocular
prosthesiscustom-made acrylic resin ocular prosthesis in which he determined
the size and positionin which he determined the size and position of the iris
byof the iris by visual judgment.visual judgment. Because irisBecause iris
positioning is a technique-sensitivepositioning is a technique-sensitive
procedure, visual assessment alone may notprocedure, visual assessment alone
may not be accurate.be accurate.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
74. Roberts.A.An instrumeny to achieve pupil alignment in
eye prosthesis.JPD 22;4:1969 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Roberts has
suggested the use of aRoberts has suggested the use of a
pupillometerpupillometer for precise alignment of the pupilfor precise
alignment of the pupil in the eye prosthesis. Though the advocatedin the eye
prosthesis. Though the advocated method may be more precise, it may not
bemethod may be more precise, it may not be feasible to use the pupillometer in
everyfeasible to use the pupillometer in every clinical set-upclinical set-up &lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
75. The iris should be bilaterally symmetrical; therefore,
accurate placement of the custom- painted iris disk on the scleral wax pattern
is critical.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
76. Satyabodh S. Guttal, Narendra P. Patil. A Simple Method
of Positioning the Iris Disk on a Custom-Made Ocular Prosthesis. A Clinical
Report.JOP ;17: (2008) 223–227 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The
transparent graph grid was used in this method to attach the iris disk.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
77. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;During the trial
of the scleral wax pattern, certain guidelines were marked on the patient’s
face with an indelible pencil ,a vertical midline was marked considering the
stable anatomical landmarks and prominent points on the face&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
78. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The midline was
marked passing through the forehead crease, glabella, tip of the nose, and
chin. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The distance from the right eye
medial canthus to the midline and left eye medial canthus to the midline was
measured. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This distance standardized the
midline marking and was used to reposition the grid template each time during
the try-in visit.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
79. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The patient was
asked to gaze straight at an object kept 4 feet away. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The operator then marked the vertical lines
coinciding with the medial and distal extremities of the iris of natural eye.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
80. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Similarly, the
horizontal lines referring to the center, inferior, and superior limits of the
iris were marked. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The facial markings
were transferred to the grid template by placing it on the patient’s face.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
81. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Markings were
also made on the transparent grid template, on the X-axis from A through H
starting from the midline, and on the left side A1 to H1; similarly, on the
Y-axis from 1 through 7 and 11 to 71. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The distance between each marking was 1 cm on
both X and Y axes.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
82. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;These markings
were transposed onto the side of defect. This can be done either directly on
the patient’s face or on the facial moulage &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The markings were transferred onto the
sculpted scleral wax pattern, and the iris button attached to the wax pattern&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
83. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The method
described in this article involves a simple procedure for positioning the iris
in a prosthetic eye &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The accurate
placement of the iris and pupil component in the ocular prosthesis simulated
the conversational gaze&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
84. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Thus, the use of
a transparent grid template helped to accurately locate and position the iris
on the custom-made ocular prosthesis rather than relying purely on the visual
assessment, the latter being subjective with possible interobserver errors&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
85. Paper Iris Disk Technique When the wax pattern is
determined to be appropriate, it is flasked and processed in scleral resin. The
scleral blank is then finished, and it is polished using pumice and acrylic
resin polish&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
86. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The scleral blank
is tried in and the middle of the pupil is marked while the patient gazes
directly at the clinician. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The size of
the iris is measured using a millimeter measurement gauge or optical scale. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The outline of the iris is then marked on the
scleral blank using Carmen red ink.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
87. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This ink will
transfer to the investing stone, facilitating the appropriate placement of the
corneal prominence. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The blank is tried
in again to verify the location and size of the iris.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
88. The location of the iris will transfer to the investment
and a scraper can then be used to create the corneal prominence of the
prosthesis in the investment&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
89. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A disk of
ordinary artist&#39;s watercolor paper is punched out using a die. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The size selected should be 1 mm smaller than
the measured size of the iris. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This will
allow the iris to appear to be the appropriate size because the corneal
prominence will cause a slight magnification of the iris disk patient&#39;s iris.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
90. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A good selection
of colors for this purpose includes ultra-marine blue, yellow ochre, burnt
sienna, burnt umber, yellow oxide, titanium white. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Colors should be mixed and reapplied in a
layering fashion to mimic the colored striations in the patient’s iris.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
91. Medial canthus Pupil IRIS ANATOMY&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
92. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Begin by painting
the darkest color, the area toward the outer edge of the iris ring (limbus). &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The color of the limbus varies from eye to
eye, but it usually is a combination of gray and iris body color.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
93. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;In the natural
eye, it can appear as a shadow from the overlapping sclera, covering the edge
of the cornea. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Next the collarette is
painted. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;It is usually a lighter color
than the body of the iris. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A black spot
should be painted in the center of the disk to represent the pupil&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
94. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The diameter
should mimic the natural pupil under indoor light conditions. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This will make size appear relatively
appropriate under most conditions.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
95. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After the paint
has dried, a drop of water is applied to create the magnification of the
corneal prominence and the color matched.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
96. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Using a flat-end
bur, a flat surface is prepared in the scleral blank for the iris painting. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A sprue wax is luted to the prepared flat
surface and tried in.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
97. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The orientation
of the surface is adjusted until the sprue points directly at the observer
while the patient looks directly into the observer&#39;s eye. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This will ensure that the prosthesis and the
natural eye will have the same gaze&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
98. •Using a large abrasive stone, the entire anterior
surface of the scleral blank is reduced at least 1 mm. •The remainder of the
prosthesis is then painted to match the sclera of the natural eye.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
99. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Fine red
embroidery threads are placed on the scleral painting to mimic the blood
vessels of the patient&#39;s natural eye. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The entire scleral portion is then coated with
monomer polymer syrup to keep the blood-vessel fibers in place and allowed to
set.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
100. Once the monomer-polymer syrup has set, the scleral
blank is replaced into the flask, and the iris painting is placed on the flat
section.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
101. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Clear ocular
acrylic resin is mixed and placed into the mold space and the flask trial
packed. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once trial packed, the flash is
removed and the location of the painting verified to ensure that it has not
moved during trial packing.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
102. BLACK IRIS DISK TECHNIQUE &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The natural eye is observed closely and the
diameter of the iris is estimated using a millimeter measurement gauge or optical
scale. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Ocular discs, which are used in
the iris painting, are available in half- mm sized increments, ranging from 11
mm to 13 mm. 120&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
103. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;They come in
black or clear, and either with or without pupil apertures. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Clear corneal buttons are available in the
same sizes as the discs. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The buttons can
also be purchased with pupils of various sizes already in place.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
104. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The technique
employed in painting the disk produces a three-dimensional effect. oil pigments
are employed in this technique but are mixed with a monomer-polymer syrup
during the painting process. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This mixing
procedure provides some degree of translucency in the iris painting and permits
rapid drying of the pigments&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
105. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The basic eye
color or background color is observed along with the limbus color. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The background color is applied to the disk
first, using brush strokes from the center toward the periphery.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
106. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After the
background color is applied and dried, a coat of the clear syrup is applied and
allowed to dry. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Characteristic
striations are applied over the clear layer and allowed to dry. A second clear
layer is then applied and further characterization accomplished&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
107. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After the second
layer is dried, the limbus color is matched around the periphery of the disk
and a third clear layer applied. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The
color around the pupil is applied over the last clear layer and the final color
evaluated with the water interface. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After a satisfactory color match has been
obtained, a final clear layer is applied and allowed to stand for 15 minutes.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
108. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A single droplet
of the monomer-polymer syrup is then placed in the center of the iris disk and
the lens button is gently placed and centered. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The positioning of the iris-lens assembly on
the wax scleral pattern is the most important phase in fabrication of the
prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
109. Fix the lens button to the scleral pattern in a manner
such that the apparent gaze of both natural and artificial eyes is on the same
object, or parallel to one another and in the same plane.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
110. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The size of the
lens assembly selected should be large enough to include the limbus. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The lens assembly is placed in a slight
depression in the scleral pattern, and a thin layer of wax should be brought up
over the curvature of the lens assembly.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
111. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This thin layer
of wax will allow the opaque white scleral acrylic resin to flow up over the
edge curvature of the lens assembly during the packing procedure, forming a
very thin, translucent layer.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
112. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The finished
pattern is then invested in a small two-piece brass flask. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The resulting scleral blank is deflasked,
trimmed, and polished&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
113. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The position and
gaze of the artificial eye is again observed. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The sclera is slightly roughened using
sandpaper disks in preparation for adding the simulated vasculature. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Rayon-thread fibrils are placed onto the
surface of the sclera using the monomer- polymer syrup.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
114. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The pattern and
type of vessels ( tortuous, straight, branched) of the opposite eye are
reproduced. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The colors found in the
sclera are usually yellow and blue, or combinations of these. Greens and browns
can also be present.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
115. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The scleral
painting begins with the application of a wash of yellow comparable to that
found on the patient&#39;s natural eye. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Next, blue is added, which is usually located
inferior and superior to the iris. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Finally, any characteristic details present in
the natural eye are added.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
116. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once complete, a
coat of monomer and polymer is applied to the sclera. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The eye is now ready for the final processing,
the application of a layer of clear acrylic resin&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
117. The prosthesis is cleaned and placed in socket. The fit
of the artificial eye are evaluated and adjustments are made as necessary.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
118. Digital imaging in the fabrication of ocular prostheses
Ioli-Ioanna Artopoulou, DDS, MS,a Patricia C. Montgomery,b Peggy J. Wesley,
CDA,c (J Prosthet Dent 2006;95:327-30.) &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Using digital imaging in the fabrication of
the ocular prostheses presents several advantages compared to the conventional
oil paint and monopoly iris painting technique&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
119. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The digital
image provides acceptable esthetic results be cause it closely replicates the
patient’s iris with minimal color adjustments and modifications. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The described technique is simple, decreases
treatment time, and requires minimal artistic skills, which are necessary in
the iris painting technique .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
120. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;However, special
digital photography equipment and settings, as well as computer software that allows
for image adjustments, are required.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
121. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Make an
impression of the anophthalmic socket with a stock acrylic resin tray designed
for ophthalmic impressions (Factor II Inc) using the ophthalmic irreversible
hydrocolloid (J-603 Special Formula Alginate; Factor II Inc).&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
122. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Pour a master
cast and fabricate a wax pattern using baseplate wax (Truwax Baseplate Wax;
Dentsply Intl, York, Pa).&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
123. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Evaluate the wax
pattern in the patient, and evaluate and finalize the sculpting following the
eye socket contours and lids configuration&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
124. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Make a digital
photograph of the patient’s iris using a digital camera (Canon EOS Digital
Rebel; Canon Inc, Tokyo, Japan) with a macro lens (Canon Macro Lens EF 100 mm
f/2.8 USM; Canon Inc) and a ring flash (Canon Macro Ring Lite Flash MR-14EX;
Canon Inc) attached. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Set the shutter
speed to 125 seconds, the aperture to F 16, and the sensitivity to ISO 640&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
125. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Evaluate the
photograph and compare it to the patient’s iris. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Using graphics software (Photoshop &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;7.0; Adobe Systems Inc, San Jose, Calif),
adjust for slight differences in color, brightness, contrast, or hue, and
format the image.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
126. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Print the final
image on 20-lb white paper with brightness87 (HP Office; Hewlett- Packard, Palo
Alto, Calif) using a laser printer with a color-ink print cartridge&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
127. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Cover the paper
iris with 3 light coats of water-resistant spray (Workable Fixatif; Krylon,
Solon, Ohio) used for artwork, and attach it to the ocular disk. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Use monopoly syrup (J-305 Monopoly
Syrup;Factor II Inc) to position the ocular button (Factor II Inc) on the iris,
and paint around the edges of the button and the disk to achieve maximum seal&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
128. Ocular button positioned on paper iris using monopoly
syrup&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
129. Disk assembly attached to wax pattern and ready for
trial insertion&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
130. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Attach the disk
assembly to the wax pattern and evaluate it in the patient. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Process the selected scleral acrylic resin at
the same temperatures, using the procedure previously described for the
conventional technique&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
131. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After
characterization is added, reprocess the ocular prosthesis with clear acrylic
(Factor II Inc) using the previously described temperatures. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Pumice and polish the completed eye and insert
it&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
132. COMPLICATIONS IN FITTNG ANOPHTHALMIC SOCKET Ptosis:
Superior eyelid ptosis is a frequent problem in the restoration of an
anophthalmic patient. Pseudoptosis is due to the loss of volume between the
implant and the lids after removal of the eye.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
133. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;If the
physiological function of the eyelids is intact, correction of Pseudoptosis is
achieved by increasing the volume of the prosthesis in the socket. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This condition usually occurs whenever a
small, poorly fitted prostheses is used.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
134. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A simple
technique of correcting Pseudoptosis is to make a larger prosthesis that will
thrust forward and separate the eyelids&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
135. Persistent ptosis requires modification of the ocular
prosthesis to correct for a deficient levator muscle, which causes the upper
eyelid to droop..&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
136. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Attempts aimed
at increasing the size of the ocular prosthesis, as seen in Pseudoptosis, will
not correct the problem in persistent ptosis. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The tension on the superior lid forces the
larger prosthesis downward, thus depressing the lower eyelid, deflecting the
gaze downward and creating patient discomfort&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
137. A thin transparent shelf can be made across the front
surface of the eye to hold the upper eyelid at the desired open position. The
shelf is 3 to 4 mm wide and is placed along the upper limbus.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
138. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This
modification of the prosthesis works well for ptosis caused by a superiorly
migrated, large, spherical implant with limited socket space between the
implant and the upper eyelid. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The major
drawback to the shelf is that eye cannot blink or close. The weight of the
upper eyelid and the action of the orbicularis muscle may press the eye
downward.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
139. This may be corrected by adding material to the
inferior tissue surface of the prosthesis to contour it backward and upward.
The surface above the shelf can be reduced to decrease the weight of the
prosthesis and to create space for a tight upper eyelid.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
140. Ectropion: - Inferior displacement of the implant can
lead to the loss of the inferior fornix and cause ectropion of the lower lid.
Patients have difficulty with retention of the prosthesis, since it has a
tendency to slip down and out over the everted lower lid.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
141. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This is
rectified by extending a thin lower edge that will press downward upon the
tarsus, and rotate it into a more vertical plane, thus creating a lower fornix.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
142. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The lower edge
should be rounded and at least 1 mm in thickness so it will not cut into the
socket. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The lower fornix will deepen
within minutes of modification, and insertion of the prosthesis and retention
will improve&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
143. Sagging lower eyelid: The weight of the prosthesis, and
the contraction force of the upper eyelid on the prosthesis can cause a
downward displacement of the lower eyelid, causing it to droop.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
144. Degenerative disease may also weaken the lower eyelid,
causing it to droop. By removing resin from the mid inferior margin of the
prosthesis, downward pressure against the middle of the lower fornix is
relieved.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
145. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Wax is added to
extend the nasal and temporal aspects of the inferior margin to create pressure
in the medial and lateral areas of the lid. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This directs the weight of the prosthesis
where the lower eyelid is strongest, near the palpebral ligaments. These
modifications tilt the tarsus of the lower eyelid favorably so that the eyelid
margin is elevated.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
146. Ocular implants are classified as 1. Integrated 2. Semi
- integrated 3. Non-integrated and 1. Buried or 2. Non-buried&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
147. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Integrated
implants are designed to improve prosthesis motility by coupling to the
overlying prosthesis. Implants is exposed through the conjunctiva to be
directly coupled to the prosthesis with a peg, pin, screw or other method.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
148. Semi-integrated ocular implants consist of an acrylic
resin implant with 4 protruding mounds on the anterior surface. These acrylic
resin mounds on the implant protrude against the encapsulating tissue. When an
ocular prosthesis is made, a counter contour to the implant is formed on the
posterior surface of the prosthesis. Nonintegrated implant This is done by
placing a hollow or solid acrylic resin sphere ranging from 10 to 22mm in
diameter.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
149. The placement of an orbital implant into an enucleated
socket was first described by Frost in 1886&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
150. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Soil described
an improved surgical method of placing the orbital implant deep within the
muscle cone, and buried beneath the posterior layer of Tenon’s capsule,
following the enucleation of the eye .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
151. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The optic nerve
and its associated vessels are severed and tied close to the posterior wall of
the capsule. The implant is placed and the posterior portion of Tenon’s capsule
is closed over the implant providing the first layer of closure.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
152. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Next, the
anterior portion of Tenon’s capsule and conjunctiva are then closed to form the
second and third layers over the implant. The horizontal rectus muscles are
then attached to the medial and lateral fornix.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
153. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;It is the
movement of the fomix in the enucleated socket that provides the motility to
the artificial eye. For example, as a person looks up. the inferior fomix
shortens, the superior fornix deepens and the prosthesis revolves upward&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
154. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;By utilizing the
posterior layer of Tenon’s capsule,a larger implant can be placed deep within
the muscle cone decreasing the incidence of implant migration and reducing the
tension on the anterior Tenon’s capsule sutures.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
155. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The larger
implant reduces the volume deficit in the superior and inferior sulcus.
preventing enophthalmos which can be produced by smaller implants. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Postoperative complications may develop during
the first weeks following surgery.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
156. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Early extrusion
of the implant may occur secondary to orbital hematoma formation and infection,
traumatic manipulation of the tissues, or placement of too large an implant.
thus creating excess tension on Tenon’s capsule&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
157. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The technique of
wrapping the orbital implant with fresh or preserved scleral tissue is thought
to be a deterrent for extrusion and migration of the implant and it is a
technique used quite frequently with enucleation &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;After enucleation. a plastic conformer and
corticosieroid antibiotic ointment is placed in the socket.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
158. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The conformer
should fit the contour of the socket and fill the depths of the fomices. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The conformer should not be removed by the
patient, and should be unnecessary, as it is designed with drainage holes to
allow mucoid discharge to escape and for insertion of postoperative medication.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
159. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The plastic
conformer is left in place for 4 to 6 weeks to reduce edema and maintain the
socket contours for the prosthetic eye. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Following healing of the anophthalmic socket,
a stock or custom eye should be placed temporarily for cosmetic and
psychological reasons.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
160. CRITERIA FOR SUCCESS OF CRANIOFACIAL OSSEOINTEGRATED
IMPLANTS According to “Swedish council on Technology assessment in Health
care”. The criteria for success is as follows. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Implants are immobile as verified by clinical
examination. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;No prolonged symptoms, such
as pain, infection, tactile disorders or nerve damage should be present in
connection with the implants.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
161. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Penetrated soft
tissue should be free from irritation in at least 85% of regular out patient
postoperative checks. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;At least 95% of
the temporal bone implants and at least 75% of other extraoral implants should
be functional after 5 years.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
162. The orbital defect &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The ideal defect is circumscribed fully by
bony orbital rim. The eyebrow should be intact. The soft tissue defining the
defect should be thin and immobile. The surface with in the defect may be lined
with a skin graft or even a free tissue flap.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
163. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;An orbital
defect may be the result of a congential anomaly (facial cleft), trauma
(gunshot wound, road traffic accident) or surgery. Even with the advent of
microscovascular surgery and free tissue transfers, surgical reconstruction
alone cannot fully restore this area. Prosthetic rehabilitation is needed.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
164. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;If the defect is
more extensive, bone and softissue grafting should be considered to restore
missing portions of the orbital rim, zygoma, or temporal or midface regions
before implant placement. The surgical restoration of contour can contribute to
a less extensive prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
165. Implant Placement &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Implants are commonly placed in the orbital
rim most often superiorly and laterally. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Placement in the inferior rim is desirable if
the shape of the defect and access permit.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
166. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This improves
the stability and retention of prosthesis. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;In larger defects extending beyond the orbital
rim, implants can be placed in the zygoma or maxilla. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Evan a single implant can help stabilize and
retain a prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
167. Surgical Positioner &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Actual placement of the implants is guided by
a surgical positioner. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This is an
acrylic resin prototype of the prosthesis that is used intraoperatively. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;It indicates the ideal position for implant
placement.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
168. It also serves as guide for selection of the retentive
mechanism and later as a time saving reference for the shape of the prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
169. The surgical positioner also helps determine if
preprosthetic surgery is needed before implant placement. Most often, the
lateral superior aspect of the orbital rim needs reduction to place an implant
at the location and remain with in guidelines of the positioner .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
170. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Implant
angulation should be parallel to the frontal plane of the face or be inward
slightly. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A protrusive angulation can
interfere with positioner contour and require compromise of the ideal shape of
the prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
171. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;At the same time
implant should not be over- angulated inward because prosthetic access for
fabrication of retentive mechanism can be hampered. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This is true especially in smaller shallow
defects when a soft-tissue flap has been used to close the opening of the
defect.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
172. Abutment selection and retention systems &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The shortest abutment that protrudes to 1 to 2
mm above the level of skin should be selected at second-stage surgery. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This can minimize stress to the implant and
still allow for hygiene and prosthetic access. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A shorter abutment takes up less space in
conjunction with the retentive mechanisms.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
173. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;At second-stage
surgery, the gauze strip surgical dressing should be wrapped carefully around
the abutments and under the healing caps so that close adaptation of skin to
the abutment and underlying bone is achieved.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
174. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Rubenstein
reported that orbital prostheses were fabricated with a wider variety of
attachments than any other type of bone- anchored facial prosthesis : bar
clips, magnets, ball studs or a combination of types.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
175. Bar-clip systems yield the highest retentive forces. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;good retention for large defects, especially
when there are implants in only the superior orbital rim. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;When implants are splinted together by the
bar, loading can be shared among them.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
176. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This type of
system permits retention and support beyond the actual position of implant. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;At least two implants must be used for this
system, but three or more spread in a slight arch are preferred to control and
distribute forces&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
177. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Because the
mechanism takes up more space than individual magnets, care must be taken that
the bar does not interfere with the ideal position of the ocular prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
178. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;REQUIREMENTS of
the bar system so as not to stress the implants.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
179. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Impression
making and bar construction can be difficult, especially if the implants are
excessively divergent (more than 350 ) or widely distributed around the orbital
defect. Asymmetric withdrawl of the prosthesis can result in amplification of
loads to the implants.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
180. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Some divergence
of implants is desirable to offer stability of the prosthesis against
horizontal forces&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
181. Use is limited: &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;when the implants are divergent, and they can
introduce forces that are not along the axis of the implants. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Like the bar-clip system, a prosthesis with
ball attachments can be more difficult for the patient to place than one with
magnetic attachment.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
182. No retention system is ideal for all situations; each
case must be evaluated to select the optimal one&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
183. PROSTHETIC TECHNIQUES: I) Fabrication of the ocular
prosthesis: Ocular prosthesis is made in conjunction with the surgical
positioner because its shape and position relate to the overall shape of the
orbital prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
184. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A stock eye
piece can be used. However, custom fabrication yields the best aesthetic
results. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A pyramidal index of acrylic
resin is incorporated on to the back surface of the eyepiece to aid in
registering its position in the wax prototype and for subsequent mold making.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
185. II) Impression making: Impression making for an orbital
prosthesis varies depending on the anatomic configuration of the orbital
defect, location of implants and type of retention system selected&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
186. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;If individual
magnets are used for retention, the MAGNACAPs are threaded into the abutments,
and the transfer magnets are placed on them. These can be connected with
autopolymerising resin to stablize them in impression.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
187. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The impression
can be made using irreversible hydrocolloid, a silicone rubber . The impression
should include the entire midface to provide adequate references and landmarks
for accurate sculpting&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
188. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Orientation
lines are marked on the patient indelible pencil and will be transferred to the
cast to aid this process. After removal of the impression and disinfection,
LAB- ANALOGUE CAPS are placed against the transfer magnets and the impression
is poured in dental stone.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
189. III Design and Fabrication of resin plate The resin
plate retains the retentive components in a rigid base and provides stability
for the prosthesis. In most cases, it should be as small as possible so as not
to interfere with the placement of the ocular prosthesis&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
190. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Magnets are
placed on the lab-analogue caps on the cast. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Wax is used to block out the defect and the
abutments&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
191. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The resin
engages this area to help retain the magnets in the plate. The area is bordered
with boxing wax, and clear autopolymerising acrylic resin is poured over the
area, covering the magnets and engaging the retentive rim. The thickness should
be minimal and uniform to control distortion&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
192. A sprinkle on method can be used to apply the resin to
better control the thickness of the plate. Alternatively, colourless urethane
dimethacrylate visible light cure resin can be used to fabricate the plate. It
is cured initially on the cast with a handheld light and then placed in the
curing unit to complete curing.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
193. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The processed
plate is shaped not to interfere with the ideal contour of the prosthesis. It
is adjusted on cast and then tried on the patient. Complete engagement of
retentive elements should be verified&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
194. IV Sculpting the wax prototype: This is where art takes
over from science. To achieve a life like orbital prosthesis, attention to
anatomy and surface detail is important. Input from the patient and family
members is encouraged during this process.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
195. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;To begin the
sculpting process, the ocular prosthesis is attached to resin plate with soft
utility wax while both are on the mastercast, using the orientation lines as a
guide. When the prosthesis is transferred to the patient, depth, position, and
gaze are evaluated relative to natural eye.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
196. V Mold making: A three – piece mold of white improved
dental stone is made : tissue side, eyepiece and outer surface.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
197. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once the wax
prototype is completed, its outline is marked on the cast with indelible pencil
. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;An impression of the defect extending
beyond the margins of the prosthesis is made with duplicating silicone
elastomer and resin forced with plaster backing.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
198. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The periphery of
this impression is poured in stone so that the center of the defect is left
open. Registration keys are placed in the tissue side of the mold.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
199. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Lab-analogues of
magnetic caps are placed on the magnets with in the resin plate.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
200. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The wax
prototype is seated back on the cast by using the transferred pencil line as
guide for orientation, and the margins are sealed. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Skin surface detail can be refined at this
time&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
201. Stone is poured into the back of the wax prototype
through the opening of the cast .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
202. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once set, wax
spacers to facilitate later mold seperation are placed in the first piece of
the mold, a seperator is applied to the stone surface, paper tape or wax is
used to box the mold, and the top portion or outer surface of the mold is
poured .&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
203. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Once the stone
has set, the mold is separated and the eyepiece and resin plate are removed.
The mold is cleaned with boiling water and detergent to remove all wax residue&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
204. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Before casting
the prosthesis, silicone elastomer is used to make a mold of the outer surface
of the resin plate while it is in place of on the tissue side of the mold. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The impression material should be applied with
a syringe around the edges to capture the ledge on the tissue side of the
plate.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
205. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Then a two piece
silicone mold is of the eyepiece and this is poured in stone. This stone
reproduction is used in the mold in place of resin eyepiece during processing
to protect it from damage. These steps allow the resin plate and prosthesis to
be remade without the patient and the prosthesis present, when a replacement
prosthesis is necessary.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
206. Maintenance of Prosthesis &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;To maintain the health of the implants and
surrounding soft tissue and to preserve the prosthesis and retention mechanism.
&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Bone anchored facial prosthesis does
require more care on the patient’s part and closer professional follow-up than
one retained with adhesive.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
207. HOME CARE AFTER ABUTMENT CONNECTION &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Follow up management actually begins once the
abutments have been placed. After the initial healing period and once a
surgical dressing is no longer needed, the patient should be instructed to
clean this area on a daily basis&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
208. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The purpose is
to remove cellular material on the skin or abutment, which can come from the
interface of the epithelium and abutment. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;This is performed with a soft, end tuft nylon
bristle toothbrush, an interproximal dental brush or a cotton swab. To
facilitate cleaning the area should be moistened first with an even mixture of
hydrogen peroxide and water to soften any dried debris&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
209. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;When checking
abutment tightness, an abutment clamp should be placed on the abutment body to
provide countertorque so that undue force is not placed on the implant.If the
abutment loosens, complete seating should be verified before retightening. This
is done with an abutment holder.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
210. HOME CARE AFTER PROSTHESIS PLACEMENT &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;On the day that the prosthesis is given to the
patient, adequate time should be allotted for instructions on placing and
removing the prosthesis as well as proper maintenance of the prosthesis,
abutments, and surrounding skin areas. This information should be written and
given to the patient, and all steps should be demonstrated.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
211. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;patient should
be careful when removing the prosthesis so that the thin margins do not tear
and the silicone rubber does not separate from the resin plate&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
212. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;At night, the
prosthesis should be removed and cleaned. The patients should wash their hands
first to decrease chances of soiling the prosthesis during handling. All
surfaces of the prosthesis should be cleaned gently with a soft, nylon-bristle
toothbrush and mild soap and water&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
213. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The prosthesis
should be patted dry with a towel and placed in a covered container. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;A denture cup or similar type of covered
container can be used.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
214. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Should be stored
away from extreme heat or direct sunlight, which can cause degradation and
discolouration of the prosthetic material. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The prosthesis should not be worn during sleep
so that air can circulate around the abutments to help maintain skin health&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
215. conclusion The goal of any prosthetic treatment is to
return the patient to society with a normal appearance and reasonable motility
of the prosthetic eye. The disfigurement resulting from loss of eye can cause
significant psychological, as well as social consequences. However with the
advancement in ophthalmic surgery and ocular prosthesis, patient can be
rehabilitated very effectively.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
216. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The maxillofacial
Prosthodontist should provide prosthetic treatment to the best of his ability
and should also consider psychological aspects and if necessary the help of
other specialist should be taken into consideration.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
217. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Sophistication
in the surgical and prosthetic reconstruction of structural and functional
defects in the craniomaxillofacial region improves the final rehabilitation
results, if carefully planned, unbiased rehabilitation regimens are established&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
218. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Bone anchored
implant retention offers patients who wear facial prosthesis increased
security, especially with large defects or where the prosthesis rests on highly
mobile tissues. Perspiration and vigorous physical activity will not affect the
retention of bone- anchored prosthesis.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
219. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Independence
from reliance on adhesives for retention frees the patient from tedious task of
applying and removing adhesive at each application and removal of prosthesis.
It prolongs the life of prosthesis, because the edges are not subjected to
excessive handling. &lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
220. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;The implant team must develop a co- ordinated
treatment plan that is delivered in an efficient manner. As much attention
should be paid to the fitting and care of soft tissues as to issues of hardware
articulation and registration.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
221. A commitment of follow-up for the clinical evaluation
of implant tissues and the maintenance and periodic replacement of the facial
prosthesis are a team responsibility and in the best interests of the patient.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
222. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Textbook of
Medical Physiology – GUYTON AND HALL &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Review of Medical Physiology - WILLAM F.
GANONG &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Medical Physiology – CHAUDHARY
REFERENCES&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
223. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Clinical
Maxillofacial Prosthetics - THOMAS D. TAYLOR &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Maxillo Facial Rehabilitation – Prosthodontic
and surgical consideration JOHN BEUMER &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Prosthetic rehabilitation-Keith.F.Thomas&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
224. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;L. M.
Sykes,Essop, Veres(J Prosthet Dent 1999;82:362-5.) &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Engelmier.R.L.Autoclavable custom made metal
impression trays to improve infection control.JPD 1987;58:121-2 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Ow,Amrith.Use of a tissue conditioner material
to modify a stock ocular prosthesis.JPD 1997;78:218-22&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
225. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Smith R
M.Relining an ocular prosthesis-A case report.JPD 1995;4:160-3 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Miller BJ: Custom ocular impression trays. J
Facial SomatoProsthet 1996;2:109-113 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Mark F. Mathews, DDS, Rick M. Smith, DDS, Alan
J. Sutton, DDS,and Ron Hudson .The Ocular Impression: A Review of the
Literature and Presentation of an lternate Technique .JPD December 2000, Volume
9, Number 4&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
226. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;McArthur RD:
Aids for positioning prosthetic eyes in orbital prosthesis. J Prosthet Dent
1977;37:320- 326 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Benson P: The fitting
and fabrication of a custom resin artificial eye. J Prosthet Dent
1977;38:532-539 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Roberts.A.An instrumeny
to achieve pupil alignment in eye prosthesis.JPD 22;4:1969&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
227. &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Satyabodh S.
Guttal, Narendra P. Patil. A Simple Method of Positioning the Iris Disk on a
Custom-Made Ocular Prosthesis. A Clinical Report.JOP ;17: (2008) 223–227 &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;Digital imaging in the fabrication of ocular
prostheses Ioli-Ioanna Artopoulou, DDS, MS,a Patricia C. Montgomery,b Peggy J.
Wesley, CDA,c (J Prosthet Dent 2006;95:327-30.)&lt;/div&gt;
&lt;!--[if gte mso 9]&gt;&lt;xml&gt;
 &lt;o:OfficeDocumentSettings&gt;
  &lt;o:AllowPNG/&gt;
 &lt;/o:OfficeDocumentSettings&gt;
&lt;/xml&gt;&lt;![endif]--&gt;&lt;!--[if gte mso 9]&gt;&lt;xml&gt;
 &lt;w:WordDocument&gt;
  &lt;w:View&gt;Normal&lt;/w:View&gt;
  &lt;w:Zoom&gt;0&lt;/w:Zoom&gt;
  &lt;w:TrackMoves/&gt;
  &lt;w:TrackFormatting/&gt;
  &lt;w:PunctuationKerning/&gt;
  &lt;w:ValidateAgainstSchemas/&gt;
  &lt;w:SaveIfXMLInvalid&gt;false&lt;/w:SaveIfXMLInvalid&gt;
  &lt;w:IgnoreMixedContent&gt;false&lt;/w:IgnoreMixedContent&gt;
  &lt;w:AlwaysShowPlaceholderText&gt;false&lt;/w:AlwaysShowPlaceholderText&gt;
  &lt;w:DoNotPromoteQF/&gt;
  &lt;w:LidThemeOther&gt;EN-US&lt;/w:LidThemeOther&gt;
  &lt;w:LidThemeAsian&gt;X-NONE&lt;/w:LidThemeAsian&gt;
  &lt;w:LidThemeComplexScript&gt;ML&lt;/w:LidThemeComplexScript&gt;
  &lt;w:Compatibility&gt;
   &lt;w:BreakWrappedTables/&gt;
   &lt;w:SnapToGridInCell/&gt;
   &lt;w:WrapTextWithPunct/&gt;
   &lt;w:UseAsianBreakRules/&gt;
   &lt;w:DontGrowAutofit/&gt;
   &lt;w:SplitPgBreakAndParaMark/&gt;
   &lt;w:EnableOpenTypeKerning/&gt;
   &lt;w:DontFlipMirrorIndents/&gt;
   &lt;w:OverrideTableStyleHps/&gt;
  &lt;/w:Compatibility&gt;
  &lt;m:mathPr&gt;
   &lt;m:mathFont m:val=&quot;Cambria Math&quot;/&gt;
   &lt;m:brkBin m:val=&quot;before&quot;/&gt;
   &lt;m:brkBinSub m:val=&quot;&amp;#45;-&quot;/&gt;
   &lt;m:smallFrac m:val=&quot;off&quot;/&gt;
   &lt;m:dispDef/&gt;
   &lt;m:lMargin m:val=&quot;0&quot;/&gt;
   &lt;m:rMargin m:val=&quot;0&quot;/&gt;
   &lt;m:defJc m:val=&quot;centerGroup&quot;/&gt;
   &lt;m:wrapIndent m:val=&quot;1440&quot;/&gt;
   &lt;m:intLim m:val=&quot;subSup&quot;/&gt;
   &lt;m:naryLim m:val=&quot;undOvr&quot;/&gt;
  &lt;/m:mathPr&gt;&lt;/w:WordDocument&gt;
&lt;/xml&gt;&lt;![endif]--&gt;&lt;!--[if gte mso 9]&gt;&lt;xml&gt;
 &lt;w:LatentStyles DefLockedState=&quot;false&quot; DefUnhideWhenUsed=&quot;true&quot;
  DefSemiHidden=&quot;true&quot; DefQFormat=&quot;false&quot; DefPriority=&quot;99&quot;
  LatentStyleCount=&quot;267&quot;&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;0&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Normal&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;heading 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 7&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 8&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;9&quot; QFormat=&quot;true&quot; Name=&quot;heading 9&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 7&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 8&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; Name=&quot;toc 9&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;35&quot; QFormat=&quot;true&quot; Name=&quot;caption&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;10&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Title&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;1&quot; Name=&quot;Default Paragraph Font&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;11&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Subtitle&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;22&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Strong&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;20&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Emphasis&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;59&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Table Grid&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; UnhideWhenUsed=&quot;false&quot; Name=&quot;Placeholder Text&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;1&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;No Spacing&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; UnhideWhenUsed=&quot;false&quot; Name=&quot;Revision&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;34&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;List Paragraph&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;29&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Quote&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;30&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Intense Quote&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 1&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 2&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 3&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 4&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 5&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;60&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Shading Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;61&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light List Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;62&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Light Grid Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;63&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 1 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;64&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Shading 2 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;65&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 1 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;66&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium List 2 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;67&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 1 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;68&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 2 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;69&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Medium Grid 3 Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;70&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Dark List Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;71&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Shading Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;72&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful List Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;73&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; Name=&quot;Colorful Grid Accent 6&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;19&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Subtle Emphasis&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;21&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Intense Emphasis&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;31&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Subtle Reference&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;32&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Intense Reference&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;33&quot; SemiHidden=&quot;false&quot;
   UnhideWhenUsed=&quot;false&quot; QFormat=&quot;true&quot; Name=&quot;Book Title&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;37&quot; Name=&quot;Bibliography&quot;/&gt;
  &lt;w:LsdException Locked=&quot;false&quot; Priority=&quot;39&quot; QFormat=&quot;true&quot; Name=&quot;TOC Heading&quot;/&gt;
 &lt;/w:LatentStyles&gt;
&lt;/xml&gt;&lt;![endif]--&gt;&lt;!--[if gte mso 10]&gt;
&lt;style&gt;
 /* Style Definitions */
 table.MsoNormalTable
 {mso-style-name:&quot;Table Normal&quot;;
 mso-tstyle-rowband-size:0;
 mso-tstyle-colband-size:0;
 mso-style-noshow:yes;
 mso-style-priority:99;
 mso-style-parent:&quot;&quot;;
 mso-padding-alt:0in 5.4pt 0in 5.4pt;
 mso-para-margin-top:0in;
 mso-para-margin-right:0in;
 mso-para-margin-bottom:10.0pt;
 mso-para-margin-left:0in;
 line-height:115%;
 mso-pagination:widow-orphan;
 font-size:11.0pt;
 font-family:&quot;Calibri&quot;,&quot;sans-serif&quot;;
 mso-ascii-font-family:Calibri;
 mso-ascii-theme-font:minor-latin;
 mso-hansi-font-family:Calibri;
 mso-hansi-theme-font:minor-latin;
 mso-bidi-language:AR-SA;}
&lt;/style&gt;
&lt;![endif]--&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/3385641375932701268/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/ocular-prosthesis-presentation.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/3385641375932701268'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/3385641375932701268'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/ocular-prosthesis-presentation.html' title='Ocular prosthesis Presentation'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-7637499219999598971</id><published>2020-04-11T14:06:00.001+05:30</published><updated>2020-04-11T14:06:53.748+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="artificial eyelashes price"/><title type='text'>artificial eyelashes price</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
&lt;span style=&quot;-webkit-text-stroke-width: 0px; background-color: white; color: #3c4043; display: inline !important; float: none; font-family: arial, sans-serif; font-size: 14px; font-style: normal; font-variant-caps: normal; font-variant-ligatures: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration-color: initial; text-decoration-style: initial; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px;&quot;&gt;Buy false &amp;amp;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;em style=&quot;-webkit-text-stroke-width: 0px; background-color: white; color: #52565a; font-family: arial, sans-serif; font-size: 14px; font-style: normal; font-variant-caps: normal; font-variant-ligatures: normal; font-weight: bold; letter-spacing: normal; orphans: 2; text-align: left; text-decoration-color: initial; text-decoration-style: initial; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px;&quot;&gt;fake eyelash&lt;/em&gt;&lt;span style=&quot;-webkit-text-stroke-width: 0px; background-color: white; color: #3c4043; display: inline !important; float: none; font-family: arial, sans-serif; font-size: 14px; font-style: normal; font-variant-caps: normal; font-variant-ligatures: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration-color: initial; text-decoration-style: initial; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px;&quot;&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;products from the leading cosmetic brands, Revlon, Eylure, Manicare, Ardell &amp;amp; more, in Priceline&#39;s online Makeup store&lt;/span&gt;&lt;/h4&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
&lt;br /&gt;
Topics related to artificial eyelashes price&lt;/h4&gt;
&lt;ul style=&quot;text-align: left;&quot;&gt;
&lt;li&gt;How much do fake lashes cost?&lt;/li&gt;
&lt;li&gt;Which fake lashes are the best?&lt;/li&gt;
&lt;li&gt;Do I put mascara on before fake lashes?&lt;/li&gt;
&lt;li&gt;Do eyelash extensions ruin your natural lashes?&lt;/li&gt;
&lt;li&gt;eyelashes price in amazon&lt;/li&gt;
&lt;li&gt;mac eyelashes price&lt;/li&gt;
&lt;li&gt;revlon false eyelashes price in india&lt;/li&gt;
&lt;li&gt;eyelashes glue price&lt;/li&gt;
&lt;li&gt;eyelashes online price&lt;/li&gt;
&lt;li&gt;eyelashes curler price&lt;/li&gt;
&lt;li&gt;eyelash curler&lt;/li&gt;
&lt;li&gt;eyelash extensions&lt;/li&gt;
&lt;li&gt;how to apply eyelashes&lt;/li&gt;
&lt;li&gt;artificial eye lashes&lt;/li&gt;
&lt;li&gt;pac eyelashes&lt;/li&gt;
&lt;li&gt;huda beauty eyelashes&lt;/li&gt;
&lt;/ul&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/7637499219999598971/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eyelashes-price.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7637499219999598971'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/7637499219999598971'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eyelashes-price.html' title='artificial eyelashes price'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-1353318994651250577</id><published>2020-04-07T23:21:00.004+05:30</published><updated>2020-04-07T23:21:58.123+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="artificial eye Wikipedia"/><title type='text'>Artificial eye Wikipedia</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Artificial eye may refer to:&lt;br /&gt;&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
&amp;nbsp;&amp;nbsp;&amp;nbsp; Visual prosthesis, functioning implant designed to restore sight&lt;/h4&gt;
A
 visual prosthesis, often referred to as a bionic eye, is an 
experimental visual device intended to restore functional vision in 
those suffering from partial or total blindness. Many devices have been 
developed, usually modeled on the cochlear implant or bionic ear 
devices, a type of neural prosthesis in use since the mid-1980s. The 
idea of using electrical current (e.g., electrically stimulating the 
retina or the visual cortex) to provide sight dates back to the 18th 
century, discussed by Benjamin Franklin,Tiberius Cavallo, and Charles 
LeRoy.&amp;nbsp;&lt;br /&gt;
&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Ocular prosthesis, non-functioning cosmetic replacement for a lost eye&lt;/h4&gt;
&lt;br /&gt;
An
 ocular prosthesis, artificial eye or glass eye is a type of 
craniofacial prosthesis that replaces an absent natural eye following an
 enucleation, evisceration, or orbital exenteration. The prosthesis fits
 over an orbital implant and under the eyelids. Though often referred to
 as a glass eye, the ocular prosthesis roughly takes the shape of a 
convex shell and is made of medical grade plastic acrylic. A few ocular 
prostheses today are made of cryolite glass. A variant of the ocular 
prosthesis is a very thin hard shell known as a scleral shell which can 
be worn over a damaged or eviscerated eye. Makers of ocular prosthetics 
are known as ocularists. An ocular prosthesis does not provide vision; 
this would be a visual prosthesis. Someone with an ocular prosthesis is 
altogether blind on the affected side and has monocular (one sided) 
vision.&lt;br /&gt;
&lt;br /&gt;
&lt;h4 style=&quot;text-align: left;&quot;&gt;
Topics&amp;nbsp; Related&amp;nbsp; to&amp;nbsp; artificial eye Wikipedia&lt;/h4&gt;
&lt;ul style=&quot;text-align: left;&quot;&gt;
&lt;li&gt;Who invented artificial eye?&lt;/li&gt;
&lt;li&gt;How does an artificial eye work?&lt;/li&gt;
&lt;li&gt;Are artificial eyes possible?&lt;/li&gt;
&lt;li&gt;How do you make fake eyes?&lt;/li&gt;
&lt;li&gt;prosthetic eye movement&lt;/li&gt;
&lt;li&gt;prosthetic eye care&lt;/li&gt;
&lt;li&gt;prosthetic eye cost&lt;/li&gt;
&lt;li&gt;artificial eye disadvantages&lt;/li&gt;
&lt;li&gt;do glass eyes move&lt;/li&gt;
&lt;li&gt;custom prosthetic eyes&lt;/li&gt;
&lt;li&gt;bionic eye&lt;/li&gt;
&lt;li&gt;prosthetic eye for sale&lt;/li&gt;
&lt;/ul&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/1353318994651250577/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-wikipedia.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/1353318994651250577'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/1353318994651250577'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/artificial-eye-wikipedia.html' title='Artificial eye Wikipedia'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-4409890699271034124</id><published>2020-04-07T01:01:00.000+05:30</published><updated>2020-04-07T01:01:14.071+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Making an Artificial Eye"/><title type='text'>  Making an Artificial Eye</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;Take an impression of the eye socket. Impression is encased in dental stone, which is very similar to plaster of paris. We obtain a wax piece that constitutes a pattern for the artificial eye. An iris button, similar to the pupil, iris, and cornea of the front of the eye is chosen and built into the wax pattern.&lt;br /&gt;
&lt;br /&gt;When satisfied with the wax pattern, we make a final mold of dental stone around it in a fiberglass flask. A thin layer of plastic is ground, filed and sanded from the front surface of the eye.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
We then make a painting shell by placing a clear polyethylene. The coloring of the artificial eye is done with the greatest of care. When the color is judged to be correct, the eye is returned to the final mold and the layer of transparent acrylic is cured onto the front surface to protect the color.&lt;br /&gt;
&lt;br /&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/4409890699271034124/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/making-artificial-eye.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/4409890699271034124'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/4409890699271034124'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/making-artificial-eye.html' title='  Making an Artificial Eye'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-2804738247654065957</id><published>2020-04-07T00:59:00.002+05:30</published><updated>2020-04-07T01:00:27.666+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="Good Artificial Eyes"/><title type='text'>Good Artificial Eyes</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
The aims with all artificial eye treatment is to help the patient 
through the operation of eye removal and to ensure the patient is happy 
with its appearance, its comfort and the psychology of having an eye 
socket without a natural eye.&lt;br /&gt;
&lt;br /&gt;
The perfect artificial eye is one which: Is comfortable&lt;br /&gt;
Shows good movement Looks normal to the observer Is easy to look after&lt;br /&gt;
&lt;br /&gt;
A magnified image of an eye with AMD&lt;br /&gt;Age-related macular degeneration (AMD)&lt;br /&gt;
Four stages of Retinal Pigmentosa&lt;br /&gt;&amp;nbsp;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/2804738247654065957/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/good-artificial-eyes.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/2804738247654065957'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/2804738247654065957'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/good-artificial-eyes.html' title='Good Artificial Eyes'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-3322876698640921979.post-525803305302581241</id><published>2020-04-07T00:58:00.005+05:30</published><updated>2020-04-07T00:58:29.940+05:30</updated><category scheme="http://www.blogger.com/atom/ns#" term="WHO IS ELIGIBLE ?"/><title type='text'>WHO IS ELIGIBLE ?</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Those who had a severe Retinal Pigmentosa&lt;br /&gt;Those who are suffering from age-related macular degeneration&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://ocularistindia.blogspot.com/feeds/525803305302581241/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/who-is-eligible.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/525803305302581241'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/3322876698640921979/posts/default/525803305302581241'/><link rel='alternate' type='text/html' href='http://ocularistindia.blogspot.com/2020/04/who-is-eligible.html' title='WHO IS ELIGIBLE ?'/><author><name>Unknown</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry></feed>