<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:blogger='http://schemas.google.com/blogger/2008' xmlns:georss='http://www.georss.org/georss' xmlns:gd="http://schemas.google.com/g/2005" xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-9131656014548957926</id><updated>2024-11-01T12:41:56.815+02:00</updated><title type='text'>PLC (PAC) - SCADA   solutions</title><subtitle type='html'>PLC SCADA SOLUTIONS, TIPS, PROGRAMMING CODES ---&#xa;PLC ITEMS &amp;amp; CARDS FOR SALE AT MY PAGES ---&#xa;PLC CODE DEVELOPMENT</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://plc-scada-programming.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default?redirect=false'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><link rel='next' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default?start-index=26&amp;max-results=25&amp;redirect=false'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>33</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-6159589697109991181</id><published>2022-12-10T17:32:00.004+02:00</published><updated>2022-12-10T17:47:46.468+02:00</updated><title type='text'>Magelis XBTP021010 Controller 350€</title><content type='html'>&lt;p&gt;&amp;nbsp;&lt;span face=&quot;Skin-market-sans&quot; style=&quot;background-color: white; color: #333333; font-size: 18px; font-weight: 700;&quot;&gt;Magelis XBTP021010 Controller 350€&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj6wfqV5wwnzp15EkR4H5fcX3Txfxl4Rr9LQgKAHhBa34w12YpQZ5xUTRiaTnOETxXtgrmU3ibZjQswb3gd9BMAax7isZnltXV5eoDGnUXxNHxwUK5GDQg5CFwGNqa_rpDKRw-2f_h3GXjHfqk3pG2Eqc1L93r51SEZD6Gq0nn5ehU14riW3UyJd062RQ/s4608/20191006_101042.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;2592&quot; data-original-width=&quot;4608&quot; height=&quot;180&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj6wfqV5wwnzp15EkR4H5fcX3Txfxl4Rr9LQgKAHhBa34w12YpQZ5xUTRiaTnOETxXtgrmU3ibZjQswb3gd9BMAax7isZnltXV5eoDGnUXxNHxwUK5GDQg5CFwGNqa_rpDKRw-2f_h3GXjHfqk3pG2Eqc1L93r51SEZD6Gq0nn5ehU14riW3UyJd062RQ/s320/20191006_101042.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixlUffhpsVFk9vaSjaU5YJMRAZCVkqYyDnBDTzDWNjldBuIio6ak8m64wXgyBGsgzJRXERWoP0sWIbbhhwFErKdmfymZmr5pKwGfI5vavuj4pSO-ro7K2Vd58tRCP02C-4oAPg4FArIvT-VwDFOHoMIU6DsYRItBf2J0xAqnVJ3bfuWKMtHHmCWuQXpQ/s4608/20191006_100903.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;4608&quot; data-original-width=&quot;2592&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixlUffhpsVFk9vaSjaU5YJMRAZCVkqYyDnBDTzDWNjldBuIio6ak8m64wXgyBGsgzJRXERWoP0sWIbbhhwFErKdmfymZmr5pKwGfI5vavuj4pSO-ro7K2Vd58tRCP02C-4oAPg4FArIvT-VwDFOHoMIU6DsYRItBf2J0xAqnVJ3bfuWKMtHHmCWuQXpQ/s320/20191006_100903.jpg&quot; width=&quot;180&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;div style=&quot;text-align: center;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;ITEM CONDITION: NEW - FOR SALE - PRICE 350€ - POSTAGE NOT INCLUDED&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div style=&quot;text-align: center;&quot;&gt;&lt;b&gt;CONTACT&lt;/b&gt;&lt;br /&gt;&lt;div style=&quot;text-align: left;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;http://kontactr.com/user/jup71&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;/div&gt;&lt;p&gt;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://plc-scada-programming.blogspot.com/feeds/6159589697109991181/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://plc-scada-programming.blogspot.com/2022/12/magelis-xbtp021010-controller-400.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6159589697109991181'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6159589697109991181'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2022/12/magelis-xbtp021010-controller-400.html' title='Magelis XBTP021010 Controller 350€'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj6wfqV5wwnzp15EkR4H5fcX3Txfxl4Rr9LQgKAHhBa34w12YpQZ5xUTRiaTnOETxXtgrmU3ibZjQswb3gd9BMAax7isZnltXV5eoDGnUXxNHxwUK5GDQg5CFwGNqa_rpDKRw-2f_h3GXjHfqk3pG2Eqc1L93r51SEZD6Gq0nn5ehU14riW3UyJd062RQ/s72-c/20191006_101042.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-3274202205631237633</id><published>2022-12-10T17:18:00.003+02:00</published><updated>2022-12-10T17:34:16.138+02:00</updated><title type='text'> TSXSUP702 CARD 100€</title><content type='html'>&lt;p&gt;&amp;nbsp;&lt;span face=&quot;Skin-market-sans&quot; style=&quot;background-color: white; color: #333333; font-size: 18px; font-weight: 700;&quot;&gt;Pre-Owned* Telemecanique TSX-SUP-702&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhC-IhErU3hVHmH02PW6p2hzBWQDNw-Zd-je7tbEzUdK2LWJyMq6YsWh9JS2nWkTXK6fwTBCRGXcmziG568-v6hlsq05ZKm6L8hN1nz6nRp9rOdgP_J9b5swYo967MviFIXtVwGl19VXndf_2IHViHiIwwEmL0OfTFr084Zbs22SbI_D8PNmqJnc_wTfQ/s4608/20200104_172917.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;2592&quot; data-original-width=&quot;4608&quot; height=&quot;180&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhC-IhErU3hVHmH02PW6p2hzBWQDNw-Zd-je7tbEzUdK2LWJyMq6YsWh9JS2nWkTXK6fwTBCRGXcmziG568-v6hlsq05ZKm6L8hN1nz6nRp9rOdgP_J9b5swYo967MviFIXtVwGl19VXndf_2IHViHiIwwEmL0OfTFr084Zbs22SbI_D8PNmqJnc_wTfQ/s320/20200104_172917.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjvoUxWiiSno9IqjcGYzqCjYN631EVFXbZPHqKLQIr6-fqE5_Q-t3J2wGIcGabeSmJefeqxM_Jmt3fJKd96iJmTphLkn_j0ehCjKINJsQxjfZqZ-fhNnGurZQhMLtDvGayPunXvKaTKBM2TzGPuANS881uv3tsNnNa7JDVxUccdctd1nNwnH5IsFoy1DQ/s4608/20200104_172949.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;4608&quot; data-original-width=&quot;2592&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjvoUxWiiSno9IqjcGYzqCjYN631EVFXbZPHqKLQIr6-fqE5_Q-t3J2wGIcGabeSmJefeqxM_Jmt3fJKd96iJmTphLkn_j0ehCjKINJsQxjfZqZ-fhNnGurZQhMLtDvGayPunXvKaTKBM2TzGPuANS881uv3tsNnNa7JDVxUccdctd1nNwnH5IsFoy1DQ/w109-h320/20200104_172949.jpg&quot; width=&quot;109&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;span face=&quot;Skin-market-sans&quot; style=&quot;background-color: white; color: #333333; font-size: 18px; font-weight: 700;&quot;&gt;&lt;div style=&quot;color: black; font-size: medium; font-weight: 400; text-align: center;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;ITEM CONDITION: USED- FOR SALE - PRICE 100€ - POSTAGE NOT INCLUDED&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div style=&quot;color: black; font-size: medium; font-weight: 400; text-align: center;&quot;&gt;&lt;b&gt;CONTACT&lt;/b&gt;&lt;br /&gt;&lt;div style=&quot;text-align: left;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;http://kontactr.com/user/jup71&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;/div&gt;&lt;/span&gt;&lt;p&gt;&lt;/p&gt;</content><link rel='replies' type='application/atom+xml' href='http://plc-scada-programming.blogspot.com/feeds/3274202205631237633/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://plc-scada-programming.blogspot.com/2022/12/tsxsup702-card-100.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3274202205631237633'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3274202205631237633'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2022/12/tsxsup702-card-100.html' title=' TSXSUP702 CARD 100€'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhC-IhErU3hVHmH02PW6p2hzBWQDNw-Zd-je7tbEzUdK2LWJyMq6YsWh9JS2nWkTXK6fwTBCRGXcmziG568-v6hlsq05ZKm6L8hN1nz6nRp9rOdgP_J9b5swYo967MviFIXtVwGl19VXndf_2IHViHiIwwEmL0OfTFr084Zbs22SbI_D8PNmqJnc_wTfQ/s72-c/20200104_172917.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-2865439931737100544</id><published>2022-12-10T17:09:00.005+02:00</published><updated>2022-12-10T17:34:45.761+02:00</updated><title type='text'>TSXP87420 CARD CPU 350€</title><content type='html'>&lt;span&gt;&amp;nbsp; &amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;span face=&quot;Skin-market-sans&quot; style=&quot;background-color: white; color: #333333; font-size: 18px; font-weight: 700;&quot;&gt;TSXP87420 - TELEMECANIQUE - TSXP87 420/Processor Used&lt;/span&gt;&lt;div&gt;&lt;span face=&quot;Skin-market-sans&quot; style=&quot;background-color: white; color: #333333; font-size: 18px; font-weight: 700;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjdurTD9ergXluSCvL9fg2WoLoXnX43azfw23VYhKB6hEtDWq-GdQ5Bvj-RXubu0kQtGkB-OZt59MCZFanA2QjpEz9k6PuhnCtl2_7RF8V6X-UmkSmD5I-wTujHgXEdyNTZWvFy_ZhPufbrt8R8Tnl1HB4CaMuVQJjX00NgFFOXQnkYzUQ5sHE0XN6JVg/s3385/TSXP87420.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;2551&quot; data-original-width=&quot;3385&quot; height=&quot;241&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjdurTD9ergXluSCvL9fg2WoLoXnX43azfw23VYhKB6hEtDWq-GdQ5Bvj-RXubu0kQtGkB-OZt59MCZFanA2QjpEz9k6PuhnCtl2_7RF8V6X-UmkSmD5I-wTujHgXEdyNTZWvFy_ZhPufbrt8R8Tnl1HB4CaMuVQJjX00NgFFOXQnkYzUQ5sHE0XN6JVg/s320/TSXP87420.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhJaHlTdjBNjX9zZpB_1cZ2G2ORPxig-okhvK5hy9KmnMnqD2gvpxxAtuiENu3sxiIKDZBArVMJXHTZhFigIwSFHRgbMi0q2WdtvpbxfFH2ol7-QvlmvFIjzHQIA-BMyLDbMl5kAYfvpWkBP1ga6cq7sTBhkmKVM82RpO53dTQKnX7tZL0C6P9itCDEAw/s3813/TSXP87420_FRONT.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;1461&quot; data-original-width=&quot;3813&quot; height=&quot;172&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhJaHlTdjBNjX9zZpB_1cZ2G2ORPxig-okhvK5hy9KmnMnqD2gvpxxAtuiENu3sxiIKDZBArVMJXHTZhFigIwSFHRgbMi0q2WdtvpbxfFH2ol7-QvlmvFIjzHQIA-BMyLDbMl5kAYfvpWkBP1ga6cq7sTBhkmKVM82RpO53dTQKnX7tZL0C6P9itCDEAw/w504-h172/TSXP87420_FRONT.jpg&quot; width=&quot;504&quot; /&gt;&lt;/a&gt;&lt;/div&gt;&lt;br /&gt;&lt;span face=&quot;Skin-market-sans&quot; style=&quot;background-color: white; color: #333333; font-size: 18px; font-weight: 700;&quot;&gt;&lt;div style=&quot;color: black; font-size: medium; font-weight: 400; text-align: center;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;ITEM CONDITION: USED - FOR SALE - PRICE 350€ - POSTAGE NOT INCLUDED&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div style=&quot;color: black; font-size: medium; font-weight: 400; text-align: center;&quot;&gt;&lt;b&gt;CONTACT&lt;/b&gt;&lt;br /&gt;&lt;div style=&quot;text-align: left;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;http://kontactr.com/user/jup71&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;/div&gt;&lt;/span&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://plc-scada-programming.blogspot.com/feeds/2865439931737100544/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://plc-scada-programming.blogspot.com/2022/12/tsxp87420-card-cpu-for-sale-250.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/2865439931737100544'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/2865439931737100544'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2022/12/tsxp87420-card-cpu-for-sale-250.html' title='TSXP87420 CARD CPU 350€'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjdurTD9ergXluSCvL9fg2WoLoXnX43azfw23VYhKB6hEtDWq-GdQ5Bvj-RXubu0kQtGkB-OZt59MCZFanA2QjpEz9k6PuhnCtl2_7RF8V6X-UmkSmD5I-wTujHgXEdyNTZWvFy_ZhPufbrt8R8Tnl1HB4CaMuVQJjX00NgFFOXQnkYzUQ5sHE0XN6JVg/s72-c/TSXP87420.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-6642013326638930112</id><published>2017-10-23T19:57:00.001+03:00</published><updated>2022-12-10T18:04:00.519+02:00</updated><title type='text'>TSXSCP114 RS485 FOR SALE 60€</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhpC7lQZOeHxkDWMf7CqezoorccOjDIkVin_lf_THMmLoDpnFlm2xCZwyfnHxlmWG2eE0Ap2EI-hCnPAQ1IeLQ0UyS-lz29C0q1q4PmJs3A0PZqStiRRN7lefeT2IIzoDaFIc7tBmaT7yFH/s1600/20150830_130339.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;900&quot; data-original-width=&quot;1600&quot; height=&quot;180&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhpC7lQZOeHxkDWMf7CqezoorccOjDIkVin_lf_THMmLoDpnFlm2xCZwyfnHxlmWG2eE0Ap2EI-hCnPAQ1IeLQ0UyS-lz29C0q1q4PmJs3A0PZqStiRRN7lefeT2IIzoDaFIc7tBmaT7yFH/s320/20150830_130339.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;span style=&quot;color: blue;&quot;&gt;&lt;b&gt;TSXSCP114 RS485&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;br /&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;ITEM CONDITION: NEW - FOR SALE - PRICE 60€ - POSTAGE NOT INCLUDED&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;PAYPAL PAYMENT&lt;/a&gt;&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;
&lt;b&gt;CONTACT&lt;/b&gt;&lt;br /&gt;
&lt;div style=&quot;text-align: left;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;http://kontactr.com/user/jup71&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://plc-scada-programming.blogspot.com/feeds/6642013326638930112/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://plc-scada-programming.blogspot.com/2017/10/tsxscp114-rs485-for-sale-75.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6642013326638930112'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6642013326638930112'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2017/10/tsxscp114-rs485-for-sale-75.html' title='TSXSCP114 RS485 FOR SALE 60€'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhpC7lQZOeHxkDWMf7CqezoorccOjDIkVin_lf_THMmLoDpnFlm2xCZwyfnHxlmWG2eE0Ap2EI-hCnPAQ1IeLQ0UyS-lz29C0q1q4PmJs3A0PZqStiRRN7lefeT2IIzoDaFIc7tBmaT7yFH/s72-c/20150830_130339.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-1352025000560092983</id><published>2017-10-23T19:44:00.009+03:00</published><updated>2022-12-10T17:32:58.264+02:00</updated><title type='text'> TSXETY110 ETHERNET PREMIUM CARD 250€</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieZ4CFt4EQF4pfKS9ueSmV8PQTERyH6OpOXLBIYFWviS5mq08yZBoj2-u3BCgeObt4joFrzqjcidmRkTxUsj4XBipfjcdRdvd0CsHemAj5CZA99DDVuR4NlLXPqOh3iBjUaQI0xvBjJaeN/s1600/20160601_201221.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; data-original-height=&quot;900&quot; data-original-width=&quot;1600&quot; height=&quot;180&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieZ4CFt4EQF4pfKS9ueSmV8PQTERyH6OpOXLBIYFWviS5mq08yZBoj2-u3BCgeObt4joFrzqjcidmRkTxUsj4XBipfjcdRdvd0CsHemAj5CZA99DDVuR4NlLXPqOh3iBjUaQI0xvBjJaeN/s320/20160601_201221.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;TSXETY110 ETHERNET PREMIUM CARD&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;a href=&quot;https://www.blogger.com/goog_1305472899&quot;&gt;ITEM CONDITION: NEW - FOR SALE - PRICE 250€ - POSTAGE NOT INCLUDED&lt;/a&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;b&gt;CONTACT&lt;/b&gt;&lt;br /&gt;
&lt;div style=&quot;text-align: left;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;http://kontactr.com/user/jup71&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://plc-scada-programming.blogspot.com/feeds/1352025000560092983/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://plc-scada-programming.blogspot.com/2017/10/tsxety110-ethernet-premium-card-450.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/1352025000560092983'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/1352025000560092983'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2017/10/tsxety110-ethernet-premium-card-450.html' title=' TSXETY110 ETHERNET PREMIUM CARD 250€'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieZ4CFt4EQF4pfKS9ueSmV8PQTERyH6OpOXLBIYFWviS5mq08yZBoj2-u3BCgeObt4joFrzqjcidmRkTxUsj4XBipfjcdRdvd0CsHemAj5CZA99DDVuR4NlLXPqOh3iBjUaQI0xvBjJaeN/s72-c/20160601_201221.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-6614038277070360374</id><published>2017-10-23T19:28:00.002+03:00</published><updated>2017-10-23T19:28:30.329+03:00</updated><title type='text'>TSX07312422 FOR SALE 80€</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3WPJsi7KO1FNbaL1PapjkWcTFVEcNsrl6pyWWaqlYauCUFz7JvHfs87BvwbCUZlbMgpjLBzug09V_YWZjrFOokXQ829K0YxGrvt0yb3lQmbJToKZcyst-v-Gw3A4BclCjd4lOzR5vICs/s1600/SNC00179.jpg&quot; imageanchor=&quot;1&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3WPJsi7KO1FNbaL1PapjkWcTFVEcNsrl6pyWWaqlYauCUFz7JvHfs87BvwbCUZlbMgpjLBzug09V_YWZjrFOokXQ829K0YxGrvt0yb3lQmbJToKZcyst-v-Gw3A4BclCjd4lOzR5vICs/s320/SNC00179.jpg&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;TSX07312422 - TSX NANO 24Vdc 14INPUTS/10OUTPUTS RELAY&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;ITEM CONDITION: NEW - FOR SALE - PRICE 80€ - POSTAGE NOT INCLUDED&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;PAYPAL PAYMENT&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/strong&gt;
&lt;div style=&quot;text-align: left;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;http://kontactr.com/user/jup71&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://plc-scada-programming.blogspot.com/feeds/6614038277070360374/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://plc-scada-programming.blogspot.com/2017/10/tsx07312422-for-sale-80.html#comment-form' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6614038277070360374'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6614038277070360374'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2017/10/tsx07312422-for-sale-80.html' title='TSX07312422 FOR SALE 80€'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3WPJsi7KO1FNbaL1PapjkWcTFVEcNsrl6pyWWaqlYauCUFz7JvHfs87BvwbCUZlbMgpjLBzug09V_YWZjrFOokXQ829K0YxGrvt0yb3lQmbJToKZcyst-v-Gw3A4BclCjd4lOzR5vICs/s72-c/SNC00179.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-503672520256206222</id><published>2016-02-22T20:44:00.000+02:00</published><updated>2017-10-23T19:30:33.109+03:00</updated><title type='text'>TSXAEM413 FOR SALE 100€</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
TSXAEM413 FOR SALE&lt;br /&gt;
100€&lt;br /&gt;
POSTAGE NOT INCLUDED&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi4O_sB8kSVjEpQQjbh8klq_krvD4ZkacngTxr4RdNUgYnOUuZt3_xFPG0oTPlinZiDhhnwGW7VzMGZJoqTvCCtYT25QVJu1CNn-hbqs1qcLQzhvKBqxdggsPgprpxczrZs_A7GUMrutJs/s1600/20160222_200632.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;180&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi4O_sB8kSVjEpQQjbh8klq_krvD4ZkacngTxr4RdNUgYnOUuZt3_xFPG0oTPlinZiDhhnwGW7VzMGZJoqTvCCtYT25QVJu1CNn-hbqs1qcLQzhvKBqxdggsPgprpxczrZs_A7GUMrutJs/s320/20160222_200632.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;span style=&quot;text-align: left;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;span style=&quot;text-align: left;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;span style=&quot;text-align: left;&quot;&gt;Contact at below address or leave a message. Thank you&lt;/span&gt;&lt;/div&gt;
http://kontactr.com/user/jup71&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/503672520256206222'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/503672520256206222'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2016/02/tsxaem413-for-sale.html' title='TSXAEM413 FOR SALE 100€'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi4O_sB8kSVjEpQQjbh8klq_krvD4ZkacngTxr4RdNUgYnOUuZt3_xFPG0oTPlinZiDhhnwGW7VzMGZJoqTvCCtYT25QVJu1CNn-hbqs1qcLQzhvKBqxdggsPgprpxczrZs_A7GUMrutJs/s72-c/20160222_200632.jpg" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-495168428200816750</id><published>2015-08-29T19:16:00.003+03:00</published><updated>2022-12-10T16:53:47.545+02:00</updated><title type='text'>TSX MICRO CARDS TSXAEZ-TSXDMZ28DR FOR SALE</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
For Sale Used Telemechanique Micro TSX cards&lt;br /&gt;
TSXAEZ802 8 Current Analog Input card =40€&lt;br /&gt;
TSXDMZ28DR 16Inputs/12Relay Outputs = 30€&lt;br /&gt;
For Sale Together or separate&lt;br /&gt;
Postage NOT included .&amp;nbsp;&lt;br /&gt;
AND others in http://books-mag-electronics.blogspot.gr/ ...Contact&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgs3lfOl41GVMw6NhZzUjhDKj2i8ECftHFbBHc3Z1fFS0mjNMe9OOxUbxghje3GbRLY3vkiKcEcUJVQOMsICqz5YSMae30U-C0Z-R8dhRlvvlMdXxTw0wY8uWC89PzHuZfun30vV6Fo5v_X/s1600/20150829_190123.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;180&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgs3lfOl41GVMw6NhZzUjhDKj2i8ECftHFbBHc3Z1fFS0mjNMe9OOxUbxghje3GbRLY3vkiKcEcUJVQOMsICqz5YSMae30U-C0Z-R8dhRlvvlMdXxTw0wY8uWC89PzHuZfun30vV6Fo5v_X/s320/20150829_190123.jpg&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgd3s47YAjP5suxlG1AhVytrHT06MYMu8GaJKbMtdAMYVuAxtT4MbZoOobMQOQOm-bkmzpbzHo198cXa_1GbTeVyaFXxKgNK-IpJVIdKZp_WIVyxn3oK-wYzh07Lcg4Zwshz7_e0elNJRWB/s1600/20150829_190145.jpg&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;320&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgd3s47YAjP5suxlG1AhVytrHT06MYMu8GaJKbMtdAMYVuAxtT4MbZoOobMQOQOm-bkmzpbzHo198cXa_1GbTeVyaFXxKgNK-IpJVIdKZp_WIVyxn3oK-wYzh07Lcg4Zwshz7_e0elNJRWB/s320/20150829_190145.jpg&quot; width=&quot;180&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
http://kontactr.com/user/jup71&lt;br /&gt;
&lt;br /&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/495168428200816750'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/495168428200816750'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2015/08/blog-post.html' title='TSX MICRO CARDS TSXAEZ-TSXDMZ28DR FOR SALE'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgs3lfOl41GVMw6NhZzUjhDKj2i8ECftHFbBHc3Z1fFS0mjNMe9OOxUbxghje3GbRLY3vkiKcEcUJVQOMsICqz5YSMae30U-C0Z-R8dhRlvvlMdXxTw0wY8uWC89PzHuZfun30vV6Fo5v_X/s72-c/20150829_190123.jpg" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-8476612398612631744</id><published>2011-04-07T16:45:00.005+03:00</published><updated>2015-01-03T00:07:54.037+02:00</updated><title type='text'>PRINTING TEMPERATURES USING ONLY PLC &amp; PRINTER</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;Printing 10 Temperatures using Only Twido PLC &amp;amp; PRINTER&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
In this Application a PLC Twido is used to print 10 temperatures directly to a &lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;u&gt;SERIAL&lt;/u&gt;&lt;/span&gt;&lt;/strong&gt; EPSON dot matrix Printer using the Port 2 as ASCII mode&lt;br /&gt;
Configuration Software Twido V3.5&lt;br /&gt;
Twido PLC CPU TWDLMDA40DTK&lt;br /&gt;
TWDNOZ232D Port 2 : ASCII&lt;br /&gt;
TWDXCPRTC&amp;nbsp;Real Time Clock&lt;br /&gt;
Analog cards 5 TWDALM3LT (2In MultiSensor/1Out)&lt;br /&gt;
The Inputs is configured as thermocouple J &lt;br /&gt;
The cable used for connection with the printer is the TSXPCX1031 in ascii mode&lt;br /&gt;
Configuration of the PLC Port2 &lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiYSJ-tMlzBNR8y9ziYWMqbFEQggSl1QXIG3nPpduvrQfSKueMaNJVg7NfDaS0dhLFxRyau26NcLEmKEC993dFcCfLGNY76DCA0LVBx548gKgFMEn0xSihFD1Nf_cOetA8WunqYRmqzM2i7/s1600/PrintingTemperatures.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiYSJ-tMlzBNR8y9ziYWMqbFEQggSl1QXIG3nPpduvrQfSKueMaNJVg7NfDaS0dhLFxRyau26NcLEmKEC993dFcCfLGNY76DCA0LVBx548gKgFMEn0xSihFD1Nf_cOetA8WunqYRmqzM2i7/s400/PrintingTemperatures.JPG&quot; height=&quot;236px&quot; width=&quot;400px&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
Configuration of Analog Cards&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhFCRXvSODVq313jRF73b1wP2kRNMmSDxGnaak9-B4U1GOjusn4SO6lFkM3P_Z8xJhZIaD1FvRAywgBpm_-6NIiXPWlnuN-xqwzjCRklq2s0d_gDIxvNu4Ylh0llr1HPjDmuRxoJXXP21VY/s1600/PrintingTemperatures1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhFCRXvSODVq313jRF73b1wP2kRNMmSDxGnaak9-B4U1GOjusn4SO6lFkM3P_Z8xJhZIaD1FvRAywgBpm_-6NIiXPWlnuN-xqwzjCRklq2s0d_gDIxvNu4Ylh0llr1HPjDmuRxoJXXP21VY/s400/PrintingTemperatures1.JPG&quot; height=&quot;211px&quot; r6=&quot;true&quot; width=&quot;400px&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
The PLC communication with the Printer is being done&amp;nbsp;using the command EXC&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhh2-wW3HYDtwfj2epXnsILxTFwhF72N0S6zjgd7TwfvWEBonCd6qP1jG9NdWzx_1zQK5AVs3nxt3SEqaRP8sYiWZovQf2_OSbqh8DSfvMtKjaE-tYIRzYuSZCcesSoEx3N6TM6bl94CYsc/s1600/Exc_Temp_Printing.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhh2-wW3HYDtwfj2epXnsILxTFwhF72N0S6zjgd7TwfvWEBonCd6qP1jG9NdWzx_1zQK5AVs3nxt3SEqaRP8sYiWZovQf2_OSbqh8DSfvMtKjaE-tYIRzYuSZCcesSoEx3N6TM6bl94CYsc/s400/Exc_Temp_Printing.JPG&quot; height=&quot;62px&quot; r6=&quot;true&quot; width=&quot;400px&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
The explanation of the EXC command is left for another post&lt;br /&gt;
&lt;br /&gt;
This application is written only for TWIDO PLC&lt;br /&gt;
&lt;br /&gt;
You could request for the program &lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;http://kontactr.com/pics/small.gif&quot; height=&quot;16px&quot; width=&quot;90px&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/8476612398612631744'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/8476612398612631744'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2011/04/printing-temperatures-using-only-plc.html' title='PRINTING TEMPERATURES USING ONLY PLC &amp; PRINTER'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiYSJ-tMlzBNR8y9ziYWMqbFEQggSl1QXIG3nPpduvrQfSKueMaNJVg7NfDaS0dhLFxRyau26NcLEmKEC993dFcCfLGNY76DCA0LVBx548gKgFMEn0xSihFD1Nf_cOetA8WunqYRmqzM2i7/s72-c/PrintingTemperatures.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-2473602882518481876</id><published>2011-04-07T14:52:00.003+03:00</published><updated>2015-01-03T00:09:29.991+02:00</updated><title type='text'>DAYLIGHT SIMULATION FISHTANK</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
This application simulate the daylight and night circle for artificial lighting &lt;br /&gt;
(fluroscents lamps) in a dark fishtank. The purpose is to control the intensity &lt;br /&gt;
of 2 fluroscent lamps during the day. So in a specific hour of the day the &lt;br /&gt;
lamps turn on slowly with a ramp-up during daybreak , then stay on &lt;br /&gt;
with full power for some time, then start to turn off slowly with a ramp down &lt;br /&gt;
during dusk period and finally stayed off in night period. &lt;br /&gt;
We use an analog voltage output (0 - 10V)&amp;nbsp;to control a fluroscent lamp rheostat. &lt;br /&gt;
&lt;br /&gt;
The ramp up period (04:00 till 08:00) &lt;br /&gt;
The steady state ON period (08:00 till 16)&lt;br /&gt;
The ramp down period (16:00 till 20:00 &lt;br /&gt;
The night Off period (20:00 till 04:00)&lt;br /&gt;
The above periods is fixed and cannot be changed. If other periods need we could change these fixed periods. The program could be expand using a XBT to change the periods, but this is left upon user request&lt;br /&gt;
&lt;br /&gt;
The configuration used is&lt;br /&gt;
Twido Software V3.5&lt;br /&gt;
We could use any Twido PLC with an analog card. In the application &lt;br /&gt;
TWDLMDA20DTK : CPU&lt;br /&gt;
TWDAMO1HT : Analog card 12 bits resolution&lt;br /&gt;
TWDXCPRTC Real Time Clock&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
In the application we use a 12 bits analog card &lt;br /&gt;
Steps/min=4095/4*60 = 17,0625steps/min&lt;br /&gt;
Voltage/min = 17,0625*10V/4095 = 0.0416667 Volts/min&lt;br /&gt;
&lt;br /&gt;
Use of the application is for dark fishtank (vivarium) not open one. Maybe the user could use the&amp;nbsp;program in various other applications&lt;br /&gt;
&lt;br /&gt;
You could request for the program &lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;http://kontactr.com/pics/small.gif&quot; height=&quot;16&quot; width=&quot;90&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/2473602882518481876'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/2473602882518481876'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2011/04/daylight-simulation-fishtank.html' title='DAYLIGHT SIMULATION FISHTANK'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-650376062946480905</id><published>2011-03-04T16:22:00.026+02:00</published><updated>2015-01-03T00:09:42.915+02:00</updated><title type='text'>PWM Function (MICRO - PREMIUM ) on PL7 software</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;PWM Function&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;script type=&quot;text/javascript&quot;&gt;
if(document.location.protocol==&#39;http:&#39;){
 var Tynt=Tynt||[];Tynt.push(&#39;cUTni6rOur4lD8adbi-bnq&#39;);Tynt.i={&quot;ap&quot;:&quot;Read more:&quot;};
 (function(){var s=document.createElement(&#39;script&#39;);s.async=&quot;async&quot;;s.type=&quot;text/javascript&quot;;s.src=&#39;http://tcr.tynt.com/ti.js&#39;;var h=document.getElementsByTagName(&#39;script&#39;)[0];h.parentNode.insertBefore(s,h);})();
}
&lt;/script&gt;&lt;br /&gt;
The PWM function supports regulation of a pulse width on a TOR output. &lt;br /&gt;
It is a function that formats the PID’s output.&lt;br /&gt;
The pulse width depends on the PID’s output (The PWM function’s INP input) &lt;br /&gt;
and the modulation period.&lt;br /&gt;
&amp;nbsp;The PID operation have been described in a previous post&lt;br /&gt;
The circuit diagram of the function’s operation is as follows:&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgZIEeYR75G6boSSujY3wptJfbxi8F6dL3l9Qd-7r6eC4tcMmssskhukIQCsgy0eWKn3JcdPDG57kkzzCvC4ytVmSIxOMy3yLoKat2AjyQwnWWTK4iNoSW59pzCrrsp8apIHjtG0cownjKp/s1600/PWM_Diagram.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;237&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgZIEeYR75G6boSSujY3wptJfbxi8F6dL3l9Qd-7r6eC4tcMmssskhukIQCsgy0eWKn3JcdPDG57kkzzCvC4ytVmSIxOMy3yLoKat2AjyQwnWWTK4iNoSW59pzCrrsp8apIHjtG0cownjKp/s400/PWM_Diagram.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
﻿To each TOP of the T_MOD modulation period, the activation period &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
in 10-3 second of the PW_O output is calculated according to the following formula:&lt;/div&gt;
State 1 of the gap (shown in 10-2 seconds) = INP * T_MOD / 1000&lt;br /&gt;
&lt;br /&gt;
The following timing diagram illustrates this formula:&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg127v85fAhyphenhyphen8JRWijZNxAiMjkgCLuB2PpVf8ak3lPY5u66v6jB9r60Lm3W4pzo4TFeSfaarbBG59ks7Ckkz8U7cuO_bdOIgRrVT2HJdJDa98NBhTiSvTM__9uiYt4_19xkofq2czIiD8hU/s1600/PWM_Diagram1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;241&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg127v85fAhyphenhyphen8JRWijZNxAiMjkgCLuB2PpVf8ak3lPY5u66v6jB9r60Lm3W4pzo4TFeSfaarbBG59ks7Ckkz8U7cuO_bdOIgRrVT2HJdJDa98NBhTiSvTM__9uiYt4_19xkofq2czIiD8hU/s400/PWM_Diagram1.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
Practical rules &lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
T_MOD = TS (where TS is the sampling period of the upstream PID),&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
The period of the current task (expressed in 10-3 second) is equal to:&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
(Required resolution)* 10 * T_MOD.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
The PID is in the MAST task, the MAST’s period is 50*10-3 s, &lt;br /&gt;
TS = 500*10-2 s and the required resolution is 1/50 &lt;br /&gt;
(a T_MOD period must contain at least 50 periods of the current task).&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;
T_MOD = TS = 500.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
The period of the task where the PWM is introduced must therefore be less &lt;br /&gt;
than 500 * 10 /50 =100 10-3 s.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
The PWM function can therefore be programmed in the MAST task.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
the resolution will be 1/100.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div align=&quot;left&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
﻿The PWM function is a standard PL7 function. As such, it is available from the&lt;br /&gt;
functions library.&lt;br /&gt;
From the language editors there, it is possible to use the help of a PWM &lt;br /&gt;
function’s input to facilitate its programming.&lt;br /&gt;
&lt;br /&gt;
From the PL7 menu Tools --&amp;gt; Library the next picture appears&lt;br /&gt;
&lt;br /&gt;
The illustration gives you a general idea of the Functions screen in the library&lt;br /&gt;
supporting the implementation of the PWM function.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjnkIcEUFlPVw1GLIePVhHi5Er1qyeb5w09Hx9XqEbxGf7EnRhzv0gIlEiAOcF4IoPENA2HhWVc8fbhrWUXsMfdt5bzsVsx_CR35ozIFxs1jAcBMSZA5xT3ya_04ucfOBFqMhbhWmxKAH-n/s1600/PWM_FunctionJPG.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;217&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjnkIcEUFlPVw1GLIePVhHi5Er1qyeb5w09Hx9XqEbxGf7EnRhzv0gIlEiAOcF4IoPENA2HhWVc8fbhrWUXsMfdt5bzsVsx_CR35ozIFxs1jAcBMSZA5xT3ya_04ucfOBFqMhbhWmxKAH-n/s400/PWM_FunctionJPG.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
The PWM function’s call syntax is:&lt;br /&gt;
PWM(INP,PW_0,PARA)&amp;nbsp; Equation 1&lt;br /&gt;
&lt;br /&gt;
For the Purpose of the example a Micro CPU TSX3722 used &lt;br /&gt;
with a TSXDSZ08T2 card&amp;nbsp; (8 Transistor Outs) in order to have &lt;br /&gt;
the digital output for the PWM output. &lt;br /&gt;
The selection of a Transistor Output was done because of&amp;nbsp;the long life time of the transistor. &lt;br /&gt;
Of course the developer has to use additional relays for the output &lt;br /&gt;
The following picture illustrate the configuration of the PLC&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2NQLmMwla-x3f_mdzePm9JktJgZtaGgT5JrJlBVCVhyphenhyphenP6uKXAPxm16VBUE487rXPbRG7Cf6oragG7MxzVNXDD2FhNNBFn82ngPymwamV8opwfj9SOB1NdtSLwjBAVNTckAACeJ97Rv4Qk/s1600/PWM_card.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;196&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg2NQLmMwla-x3f_mdzePm9JktJgZtaGgT5JrJlBVCVhyphenhyphenP6uKXAPxm16VBUE487rXPbRG7Cf6oragG7MxzVNXDD2FhNNBFn82ngPymwamV8opwfj9SOB1NdtSLwjBAVNTckAACeJ97Rv4Qk/s400/PWM_card.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
The PID operate﻿ function which explained in a previous post is&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEggc9tKZz6F5_jr6FTeZUK0Dn_yzkBxbBtRJfJRraPO_bcZa6NVLiGl-R7Ys0cn4QVuqnf_qqU4Eu3HJYwE5rcjsVffPY1ctDVmzyNVazrAHEuvoQ31rcZRrdfFti4p3ZVle7ml6MFQOpZe/s1600/PID_Function_Info.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;278&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEggc9tKZz6F5_jr6FTeZUK0Dn_yzkBxbBtRJfJRraPO_bcZa6NVLiGl-R7Ys0cn4QVuqnf_qqU4Eu3HJYwE5rcjsVffPY1ctDVmzyNVazrAHEuvoQ31rcZRrdfFti4p3ZVle7ml6MFQOpZe/s400/PID_Function_Info.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
Next the Allingment of the T_MOD (PWM) on the TS of the PID&amp;nbsp;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&amp;nbsp;which is&amp;nbsp;the %MW105 &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhHneiq7W47iNeMUYOEJVTtq1ohXdNpgBy9ot6qXnh_dklM1poHbI4RVZ2Zi5LO42sWiK3x9R0d56Mcc-L450d8EZWO-k2nADtxZ4hLSWxpk_l76NMFOBKJRNu5NYoLcP46pjomoE2NEQGq/s1600/PWM_InAssociate.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;86&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhHneiq7W47iNeMUYOEJVTtq1ohXdNpgBy9ot6qXnh_dklM1poHbI4RVZ2Zi5LO42sWiK3x9R0d56Mcc-L450d8EZWO-k2nADtxZ4hLSWxpk_l76NMFOBKJRNu5NYoLcP46pjomoE2NEQGq/s400/PWM_InAssociate.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&amp;nbsp;And Finally in the Mast Or Fast task the PWM Operate Function in&amp;nbsp;which the PWM output is the %Q3.0&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3xMqSyDhC_Np0j5AbY5JFx2MqMaCdfZhY4oiQOuo4bdIV_jh5AuY3giOOXSTFAiU79uvUkx_dqG2LoitBzpRoDkCF7jeZzIghMP6UU8vqT7VOsBbnpv9bRvE8gfz_rQgxYCkialZMBG9M/s1600/PWM.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;83&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg3xMqSyDhC_Np0j5AbY5JFx2MqMaCdfZhY4oiQOuo4bdIV_jh5AuY3giOOXSTFAiU79uvUkx_dqG2LoitBzpRoDkCF7jeZzIghMP6UU8vqT7VOsBbnpv9bRvE8gfz_rQgxYCkialZMBG9M/s400/PWM.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
Using the equation 1 &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
PWM(INP,PW_0,PARA)&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
INP = %MW52 &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
PW_0 = :%Q3.0&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
PARA = %MW90:5&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
The following Illustration&amp;nbsp;all the parameters explained&amp;nbsp;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhPqywTc16UVkBfmHHU47G-chSeEIPYIWi0JNk185Cyybtq_-IyCEN77lUQzWO4SstEdgEr4H-pScU3GXLtP3GIxBlhXgsY0AMq1JuO3YGCnb3gf9oOm416Lt3wdwQe_mbPCw5usH27Qac9/s1600/PWM_ParaTable.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;311&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhPqywTc16UVkBfmHHU47G-chSeEIPYIWi0JNk185Cyybtq_-IyCEN77lUQzWO4SstEdgEr4H-pScU3GXLtP3GIxBlhXgsY0AMq1JuO3YGCnb3gf9oOm416Lt3wdwQe_mbPCw5usH27Qac9/s400/PWM_ParaTable.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;&lt;u&gt;&amp;nbsp;NOTE FOR THE READER&lt;/u&gt; : THE ABOVE IS THE CONFIGURATION ONLY AND TYPICAL EXAMPLES ON HOW TO CONGIGURE THE PWM FUNCTION IN PL7 SOFTWARE. THE INFORMATION GIVEN ARE NOT A COMPLETE APPLICATION AND THE DEVELOPER MUST MAKE HIS OWN CALCULATIONS TO ACHIEVE&amp;nbsp;PWM CONTROL IN HIS SPECIFIC APPLICATION. IT&#39;S THE RESPONSIBILITY OF THE USER TO USE THE INFORMATION ABOVE CORRECTLY IN THE APPLICATION. IMPROPER USE MAY RESULT IN EQUIPMENT DAMAGE OR HUMAN INJURIES&lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;http://kontactr.com/pics/small.gif&quot; height=&quot;16&quot; width=&quot;90&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/650376062946480905'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/650376062946480905'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2011/03/pwm-function-micro-premium-on-pl7.html' title='PWM Function (MICRO - PREMIUM ) on PL7 software'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgZIEeYR75G6boSSujY3wptJfbxi8F6dL3l9Qd-7r6eC4tcMmssskhukIQCsgy0eWKn3JcdPDG57kkzzCvC4ytVmSIxOMy3yLoKat2AjyQwnWWTK4iNoSW59pzCrrsp8apIHjtG0cownjKp/s72-c/PWM_Diagram.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-6507140344250186909</id><published>2011-03-03T13:34:00.012+02:00</published><updated>2015-01-03T00:11:14.020+02:00</updated><title type='text'>PID Software function (MICRO - PREMIUM)  on PL7</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;PID Function&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
The PID function completes a PID correction via an analog measurement and&lt;br /&gt;
setpoint on the [0-10000] format and provides an analog command to the &lt;br /&gt;
same format.&lt;br /&gt;
&lt;br /&gt;
Available PID functions&lt;br /&gt;
&lt;br /&gt;
serial / parallel PID algorithm,&lt;br /&gt;
forward / backward action (according to the KP gain sign),&lt;br /&gt;
action derived from measurement or from distance,&lt;br /&gt;
high and low limitation of the setpoint to [0-10000],&lt;br /&gt;
high and low limitation of the output in automatic mode,&lt;br /&gt;
anti-saturation of the integral action,&lt;br /&gt;
Manual/Automatic operating modes without definitely changing,&lt;br /&gt;
PID access control through the dialog operator,&lt;br /&gt;
operating in integrator for (KP = TD =0).&lt;br /&gt;
&lt;br /&gt;
Here is the operating principle diagram of the PID function&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirJsFvfzz3VjDbt8GtTnCqafGZEXKr03zEqd0W6ohz2duR1W5Owyd1r2IoHVMy6z2RfeLhCA-5zFO1vnIqEMqXMSVkiq-trUrR51X_k4frwEw2OUiwFY1HIHoYB7K3Y9oQMRezQ6ODKdHn/s1600/PID+diagram.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;317&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirJsFvfzz3VjDbt8GtTnCqafGZEXKr03zEqd0W6ohz2duR1W5Owyd1r2IoHVMy6z2RfeLhCA-5zFO1vnIqEMqXMSVkiq-trUrR51X_k4frwEw2OUiwFY1HIHoYB7K3Y9oQMRezQ6ODKdHn/s400/PID+diagram.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
PID functions are standard PL7 functions. They are therefore available from the function library.&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
From the PL7 menu Tools --&amp;gt; Library the next picture appears&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgqXrMm1eTFMaEaudh46zAedKTT0NfNwhS-xLZqIbrgIWJIUCs44YsOraTf6JyMD35h86rGT9SQpjWaIkaMFr_6tqRQuxj0j87Y9Qtu-4FrF1oCBvY2_SEcJMumEDFxjBu0Hz5bfKtiuhLw/s1600/PID_Function.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;212&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgqXrMm1eTFMaEaudh46zAedKTT0NfNwhS-xLZqIbrgIWJIUCs44YsOraTf6JyMD35h86rGT9SQpjWaIkaMFr_6tqRQuxj0j87Y9Qtu-4FrF1oCBvY2_SEcJMumEDFxjBu0Hz5bfKtiuhLw/s400/PID_Function.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
The call syntax for the PID function is:&lt;/div&gt;
&lt;br /&gt;
PID(TAG,UNIT,PV,OUT,AUTO,PARA)&amp;nbsp;- &amp;nbsp;Equation 1&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
Note: A PID function can be entered in any periodic task (MAST or FAST). ﻿&lt;br /&gt;
&lt;br /&gt;
Call of PID function&amp;nbsp;. We are Opening in a PL7v4.5 Project (Micro or Premium) a Fast periodic Task section and insert an operate instruction. Right click inside the operate function to call for a function. &lt;br /&gt;
See the following picture&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixEM7ZHNPgHvoNKgeEYf9bMdOpAc7N3PyyvoRXh5F0sLmrZhCSHf6CdxxSUaXXmikLX5yzxtTBZVvNUqrRLoVQsjeL-LqNuVgKHgZ81sTFbnKTxol-S5SrSgiemMAgSTIi_YOhjGEmMcBm/s1600/PID_Function_Call.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;211&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixEM7ZHNPgHvoNKgeEYf9bMdOpAc7N3PyyvoRXh5F0sLmrZhCSHf6CdxxSUaXXmikLX5yzxtTBZVvNUqrRLoVQsjeL-LqNuVgKHgZ81sTFbnKTxol-S5SrSgiemMAgSTIi_YOhjGEmMcBm/s400/PID_Function_Call.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
The following illustration appears: &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixS2Qe9Y-6dFVIkjtwWt4Fqx_7pPt4Yd1r2vZspb9CBnuV7IOxVsW32y5FwQFgubUjYZ0DbPp7rRdstYiVCEtaW_m80PSsiPjKG-b_bUwdC12F7YcYD_dB-TCx_P9lKZOPa1E1IC29yx5e/s1600/PID_Function_Call2.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;258&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixS2Qe9Y-6dFVIkjtwWt4Fqx_7pPt4Yd1r2vZspb9CBnuV7IOxVsW32y5FwQFgubUjYZ0DbPp7rRdstYiVCEtaW_m80PSsiPjKG-b_bUwdC12F7YcYD_dB-TCx_P9lKZOPa1E1IC29yx5e/s400/PID_Function_Call2.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
Then fullfill with parameters the PID call in grey zone . See the following picture&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhecIlZaPB6g3dKQhJKvmUgnNCMPIz80tMPtY96toz6F8u3iKFPGgcoHvbxr2gLuNUWxyrYgaVLROiR8nGSVzsqHLDXspfOoyGEEw8jMJ8_k-uJwVoFxCTB10d6t5b_c82ExXJhtv0YSIob/s1600/PID_Function_Call3.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;256&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhecIlZaPB6g3dKQhJKvmUgnNCMPIz80tMPtY96toz6F8u3iKFPGgcoHvbxr2gLuNUWxyrYgaVLROiR8nGSVzsqHLDXspfOoyGEEw8jMJ8_k-uJwVoFxCTB10d6t5b_c82ExXJhtv0YSIob/s400/PID_Function_Call3.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
The following picture is the PID function fullfilled . Next we are going to analyze the parameters entered&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixlUWL2vkBJX2Ey2EQZwwD-l5kIV6Z5FCWKxbWW2IswVkwoLPCbBhnjlud-gy41CVenPsEezPWxv652Jmr8FM-lpq4InO1u5qvw7bYqDcfRTxMnAiX9D3Hymq55gn4duCr2AHEnLl3qQlh/s1600/PID_Function_Info.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;278&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixlUWL2vkBJX2Ey2EQZwwD-l5kIV6Z5FCWKxbWW2IswVkwoLPCbBhnjlud-gy41CVenPsEezPWxv652Jmr8FM-lpq4InO1u5qvw7bYqDcfRTxMnAiX9D3Hymq55gn4duCr2AHEnLl3qQlh/s400/PID_Function_Info.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;br /&gt;
As we can see the parameters are 6 and is the equation 1 . So.&lt;br /&gt;
&lt;br /&gt;
PID(TAG,UNIT,PV,OUT,AUTO,PARA)&lt;br /&gt;
TAG = %MB0:8&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Used by CCX17 . not neccessary &lt;br /&gt;
UNIT = %MB10:8&amp;nbsp;&amp;nbsp; Used by CCX17 . not neccessary &lt;br /&gt;
PV = %MW50&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Process value of the function&lt;br /&gt;
OUT = %MW52&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Analog PID output&lt;br /&gt;
AUTO = %M40&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Operating Mode &lt;br /&gt;
PARA = %MW100:43&amp;nbsp; PID Parameters &lt;br /&gt;
&lt;br /&gt;
Detailed Description of Parameters&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi59YpzSmd1MtGKMqNzfi0c8AMbyPsCqDzFOnK93ZT6_eTM5ltfHo5LxALG55x0KTyS9vznrE6-M0xW3OHQ-gRODHmhA_B_bqMZ3iC142sB5tM6AErLTad-PhG5S9iMSgBRAu0YHK2Up0-B/s1600/PID_para.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;231&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi59YpzSmd1MtGKMqNzfi0c8AMbyPsCqDzFOnK93ZT6_eTM5ltfHo5LxALG55x0KTyS9vznrE6-M0xW3OHQ-gRODHmhA_B_bqMZ3iC142sB5tM6AErLTad-PhG5S9iMSgBRAu0YHK2Up0-B/s400/PID_para.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhZZ387WpNpidpkFTyuLkKbAtxcjBdgv1TMFbwn2FU74kFs0vOiPMSwKQv6rpBXcX_T6AiuXg1apjHbqMCGq4eGDacA2q99d6xKHE4AmhIm_OMscbrHXqTQ-f6RSC9pTfj6-qHcg8_rut5R/s1600/PID_para2.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;640&quot; l6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhZZ387WpNpidpkFTyuLkKbAtxcjBdgv1TMFbwn2FU74kFs0vOiPMSwKQv6rpBXcX_T6AiuXg1apjHbqMCGq4eGDacA2q99d6xKHE4AmhIm_OMscbrHXqTQ-f6RSC9pTfj6-qHcg8_rut5R/s640/PID_para2.JPG&quot; width=&quot;408&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
As we could see from the 2nd table above the PID parameters like internal SP=Setpoint, Kp,Ti,Td,Ts &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
are&amp;nbsp;in the range of %MW100:43. &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
So for SP = %MW100 and so on&amp;nbsp;in which the developer should setup a value&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
On cold start, the PID resumes in manual, with the output at 0. &lt;br /&gt;
To impose automatic mode or a manual input not at zero after a cold start, &lt;br /&gt;
you must program the initialization sequence after the PID call.&lt;br /&gt;
&amp;nbsp; &lt;br /&gt;
Where the process control Human Machine Interface is used &lt;br /&gt;
(DEVAL_MMI = 0)&lt;br /&gt;
Where no Human Machine Interface is used DEVAL_MMI = 1.&lt;br /&gt;
&lt;br /&gt;
Examples.&amp;nbsp;In this example, the TAG and UNIT parameters are not applicable, &lt;br /&gt;
so you can simply enter the values.&lt;br /&gt;
&lt;br /&gt;
(* PID correction on temperature process control loop *)&lt;br /&gt;
PID(‘TEMP’,’DEGRES’,%MW10,%MW1&amp;gt;&amp;gt;&amp;nbsp; OPERATE FUNCTION&lt;br /&gt;
with PID(‘TEMP’,’DEGRES’,%MW10,%MW11,%M10,%MW20:43)&lt;br /&gt;
&lt;br /&gt;
(* PID correction on process control loop without built-in HMI&lt;br /&gt;
PID(‘ ’,’ ’,%MW10,%MW1&amp;gt;&amp;gt;&amp;nbsp;&amp;nbsp; OPERATE FUNCTION&lt;br /&gt;
with PID(‘ ’,’ ’,%IW3.1,%QW4.0,%M10,%MW20:43)&lt;br /&gt;
&lt;br /&gt;
&amp;nbsp; &lt;br /&gt;
&lt;div style=&quot;text-align: left;&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;u&gt;&lt;strong&gt;NOTE FOR THE READER&lt;/strong&gt;&lt;/u&gt;&lt;/span&gt; : &lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;THE ABOVE IS THE CONFIGURATION ONLY AND TYPICAL EXAMPLES ON HOW TO CONGIGURE THE PID FUNCTION IN PL7 SOFTWARE. THE INFORMATION GIVEN ARE NOT A COMPLETE APPLICATION AND THE DEVELOPER MUST MAKE HIS OWN CALCULATIONS TO ACHIEVE PID CONTROL IN HIS SPECIFIC APPLICATION. &lt;/strong&gt;&lt;/span&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;IT&#39;S THE RESPONSIBILITY OF THE USER TO USE THE INFORMATION ABOVE CORRECT IN HIS APPLICATION. IMPROPER USE MAY RESULT IN EQUIPMENT DAMAGE OR HUMAN INJURIES&lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;http://kontactr.com/pics/small.gif&quot; height=&quot;16&quot; width=&quot;90&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6507140344250186909'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6507140344250186909'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2011/03/pid-software-function-micro-premium-on.html' title='PID Software function (MICRO - PREMIUM)  on PL7'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEirJsFvfzz3VjDbt8GtTnCqafGZEXKr03zEqd0W6ohz2duR1W5Owyd1r2IoHVMy6z2RfeLhCA-5zFO1vnIqEMqXMSVkiq-trUrR51X_k4frwEw2OUiwFY1HIHoYB7K3Y9oQMRezQ6ODKdHn/s72-c/PID+diagram.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-306905189553957061</id><published>2010-11-25T14:16:00.001+02:00</published><updated>2015-01-03T00:11:25.291+02:00</updated><title type='text'>IMPLEMENTING ALARM (LADDER) IN PLC</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
The following describe how to&amp;nbsp;implement simple&amp;nbsp;alarms in a PLC.&lt;br /&gt;
We used a MICRO PLC TSX3722 and a card &lt;br /&gt;
TSXDMZ28DR&amp;nbsp; (16Inputs/12Outputs) but any PLC could be used.&lt;br /&gt;
&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
Here is the electrical drawing&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEik5CVqb1H6hmaeiaC91IBAgtr0jU_DCbpHSG8mmjv7SDM2SG7eGbWzElPYGHMzD5w0EkOCiOUN6-R9hzsdGSs98SKdLnks_TO-lA9QJJkoGFoXIY6J78SQVRgrHG-UGzgvM9fucc2zGMOx/s1600/Alarm_Eplan.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEik5CVqb1H6hmaeiaC91IBAgtr0jU_DCbpHSG8mmjv7SDM2SG7eGbWzElPYGHMzD5w0EkOCiOUN6-R9hzsdGSs98SKdLnks_TO-lA9QJJkoGFoXIY6J78SQVRgrHG-UGzgvM9fucc2zGMOx/s400/Alarm_Eplan.JPG&quot; height=&quot;348&quot; j6=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
The implementation on the PLC is for each input . 2 Inputs used for this example.&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiPY6rsh1Xdgm9vGWymY74N8FwoLTP1gwRi2f78gEXmer_44r95g9Q0olrubqdeHt-4DT69XRQh5chm6dFyJPJFOn_CPsL0rcGjcYM_ZSZ4HAFiJfwyQlQGLNjDCGyGeB-Yno2AJYhzZ7Kd/s1600/Alarm_LD1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiPY6rsh1Xdgm9vGWymY74N8FwoLTP1gwRi2f78gEXmer_44r95g9Q0olrubqdeHt-4DT69XRQh5chm6dFyJPJFOn_CPsL0rcGjcYM_ZSZ4HAFiJfwyQlQGLNjDCGyGeB-Yno2AJYhzZ7Kd/s400/Alarm_LD1.JPG&quot; height=&quot;197&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
﻿&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
﻿The following images showing how to implement the HORN and the LIGHT signalling. &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjl4UIuUIvxNWevZNnYmBewtP4cqyXFPtcrpG45qtPDs7VR29JGbaOMohpsmsirXKf3T5xEz9pEcnAw6RD0Ko3ai_lDUNoyfbMSynwh_MvRnW1AHuyPKKhTEp3ty6SZyg5rBbGdNByB8CGA/s1600/Horn_LD1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjl4UIuUIvxNWevZNnYmBewtP4cqyXFPtcrpG45qtPDs7VR29JGbaOMohpsmsirXKf3T5xEz9pEcnAw6RD0Ko3ai_lDUNoyfbMSynwh_MvRnW1AHuyPKKhTEp3ty6SZyg5rBbGdNByB8CGA/s320/Horn_LD1.JPG&quot; height=&quot;155&quot; ox=&quot;true&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhivkTRMKfV6Llb2RyU0g15VRHrEOPBBxnUPgcdAg9kP2GcBf7lsTuIAeR47Aw-_POqLnUsqP0mtkvTZjYbWo_u6K-e9UYxJLHtFbrIH0v8vw_u4TL4e02J5aM2js2Fv52WRjjS4tznnJgu/s1600/Light_LD1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhivkTRMKfV6Llb2RyU0g15VRHrEOPBBxnUPgcdAg9kP2GcBf7lsTuIAeR47Aw-_POqLnUsqP0mtkvTZjYbWo_u6K-e9UYxJLHtFbrIH0v8vw_u4TL4e02J5aM2js2Fv52WRjjS4tznnJgu/s320/Light_LD1.JPG&quot; height=&quot;162&quot; ox=&quot;true&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
As the figures shows the auxiliarys bits are for the Horn indicator and the Alarm Inputs are for the LIGHT indicator. The programmer can also add as many alarms as he wish to this rungs either directly or as a sum of alarms. It is left to programmer how to achieve this, but consider the limitation of the rung when using a PLC like the MICRO As you could see there are 7 vertical and 11 horizontal positions. In the&amp;nbsp;figures several inputs as alarms (errors - thermal relay etc) and auxiliaries added to demonstrate how to add more than 7 vertical contacts.&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;http://kontactr.com/pics/small.gif&quot; height=&quot;16&quot; width=&quot;90&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/306905189553957061'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/306905189553957061'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/11/implementing-alarm-ladder-in-plc.html' title='IMPLEMENTING ALARM (LADDER) IN PLC'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEik5CVqb1H6hmaeiaC91IBAgtr0jU_DCbpHSG8mmjv7SDM2SG7eGbWzElPYGHMzD5w0EkOCiOUN6-R9hzsdGSs98SKdLnks_TO-lA9QJJkoGFoXIY6J78SQVRgrHG-UGzgvM9fucc2zGMOx/s72-c/Alarm_Eplan.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-5799551379601905039</id><published>2010-11-22T11:40:00.000+02:00</published><updated>2010-11-27T00:04:01.320+02:00</updated><title type='text'>PUMPS CIRCULATION FOR FOUNTAINS APPLICATION</title><content type='html'>PUMPS CIRCULATION FOR FOUNTAINS&lt;br /&gt;
&lt;br /&gt;
This is an application which consists of 3 pumps circulate per 2 a 4th filter pump and a 5th waste water pump for controlling a fountain. The application was developed with &lt;strong&gt;&lt;u&gt;&lt;span style=&quot;color: red;&quot;&gt;Zelio Logic SR2B201FU&lt;/span&gt;&lt;/u&gt;&lt;/strong&gt; with real time Clock and Display capabilities.&lt;br /&gt;
&lt;br /&gt;
The requirements are&lt;br /&gt;
&lt;br /&gt;
1) 3 Pumps working per 2 in circular rotation (1-2) , (2-3), (3-1) for scheduled time during the day&lt;br /&gt;
&lt;br /&gt;
2) 1 Filter Pump which running schedule &lt;br /&gt;
&lt;br /&gt;
3) 1 waste water Pump which run with a level sensor command&lt;br /&gt;
&lt;br /&gt;
4) 1 electrovalve which open with a filling level sensor&lt;br /&gt;
&lt;br /&gt;
5) 1 low level sensor protecting the 4 pumps for dry working&lt;br /&gt;
&lt;br /&gt;
6) 1 Voltage detector&lt;br /&gt;
&lt;br /&gt;
Schedule program for the 3 pumps with 1 zelio button is:&lt;br /&gt;
&lt;br /&gt;
1st program : (08:00 – 14:00) and (17:00 - 24:00)&lt;br /&gt;
&lt;br /&gt;
2nd program : (07:00 – 15:00) and (17:00 – 01:00)&lt;br /&gt;
&lt;br /&gt;
3rd program : (07:00 – 16:000 and (17:00 – 01:00)&lt;br /&gt;
&lt;br /&gt;
4th program : (07:00 – 01:00)&lt;br /&gt;
&lt;br /&gt;
Schedule for 4th filter pump is 2 hours stop/ 1 hour run per day&lt;br /&gt;
&lt;br /&gt;
&lt;strong&gt;&lt;u&gt;INPUTS&lt;/u&gt;&lt;/strong&gt;&lt;br /&gt;
&lt;br /&gt;
I1 waste water level sensor&amp;nbsp; - NO&lt;br /&gt;
&lt;br /&gt;
I2 Voltage Detector and Emergency Stop - NC&lt;br /&gt;
&lt;br /&gt;
I3 Dry (Low Level) sensor – Deenergise Pumps – except waste water pump&amp;nbsp; - NC&lt;br /&gt;
&lt;br /&gt;
I4 Filling level sensor (Valve activation) - NC&lt;br /&gt;
&lt;br /&gt;
I5 Thermal relay Pump No1 - NC&lt;br /&gt;
&lt;br /&gt;
I6 Thermal relay Pump No2 - NC&lt;br /&gt;
&lt;br /&gt;
I7 Thermal relay Pump No3 - NC&lt;br /&gt;
&lt;br /&gt;
I8 Thermal relay filter pump - NC&lt;br /&gt;
&lt;br /&gt;
I9 Thermal relay waste water pump - NC&lt;br /&gt;
&lt;br /&gt;
I10 Reset Button - NO&lt;br /&gt;
&lt;br /&gt;
Z1 Zelio Start and Select Schedule program button . Position 1 Stop. Other positions 2 to 5 schedule program running.&lt;br /&gt;
&lt;br /&gt;
NC : Normally close contact&amp;nbsp; - NO : Normally Open contact (external)&lt;br /&gt;
&lt;strong&gt;&lt;u&gt;OUTPUTS&lt;/u&gt;&lt;/strong&gt;&lt;br /&gt;
&lt;br /&gt;
O1 RUN Pump No1&lt;br /&gt;
&lt;br /&gt;
O2 RUN Pump No2&lt;br /&gt;
&lt;br /&gt;
O3 RUN Pump No3&lt;br /&gt;
&lt;br /&gt;
O4 RUN Filter Pump &lt;br /&gt;
&lt;br /&gt;
O5 RUN Waste water Pump&lt;br /&gt;
&lt;br /&gt;
O6 Filling Valve command OPEN&lt;br /&gt;
&lt;br /&gt;
O7 Alarm Horn&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;margin: 0cm 0cm 10pt;&quot;&gt;&lt;b style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;Note: The program needs a latch at the Z1 cam encoder in order to restart after a power failure. It is left upon the user to decide if this requirement will &lt;span style=&quot;mso-spacerun: yes;&quot;&gt;&amp;nbsp;&lt;/span&gt;be added . In this application the customer have chosen NOT to have that capability. A manual restart needed . Alarm with horn when power voltage fail &lt;/span&gt;&lt;/b&gt;&lt;/div&gt;&lt;div class=&quot;MsoNormal&quot; style=&quot;margin: 0cm 0cm 10pt;&quot;&gt;&lt;b style=&quot;mso-bidi-font-weight: normal;&quot;&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;You could request for the program &lt;/span&gt;&lt;/b&gt;&lt;/div&gt;&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img src=&quot;http://kontactr.com/pics/small.gif&quot; border=&quot;0&quot; width=&quot;90px&quot; height=&quot;16px&quot; /&gt;&lt;/a&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/5799551379601905039'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/5799551379601905039'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/11/pumps-circulation-for-fountains.html' title='PUMPS CIRCULATION FOR FOUNTAINS APPLICATION'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-6564447908313575810</id><published>2010-11-19T21:25:00.000+02:00</published><updated>2015-01-03T00:18:01.802+02:00</updated><title type='text'>MICRO TELEMECANIQUE P.L.C CONNECTION WITH PC THROUGH MODEMs - OLDER VERSION</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;u&gt;ATTENTION TO THE READER&lt;/u&gt;&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;u&gt;NOTE :&lt;/u&gt; THIS DOCUMENT IS MOST FOR EDUCATIONAL PURPOSE ONLY, AS THE APPLICATION WAS DEVELOPED WITH PRIOR VERSIONS OF MICRO - PL7 SOFTWARE AND WITH NO GENER MODEMS. THE RECOMMENDED CONNECTION IS THAT WITH GENER OR ETIC MODEMS OR ANY OTHER MODEM THAT SCHNEIDER ELECTRIC RECOMMEND. YOU COULD FIND THE APPLICATION WITH GENER MODEMS &lt;a href=&quot;http://www.global-download.schneider-electric.com/852575620060EFD9/all/852566B70073220C85256975002E9B06?OpenDocument&amp;amp;L=EL&amp;amp;p=537&amp;amp;idxUrl=repositoryGreece\\index.nsf&amp;amp;XID=225305&amp;amp;XHOST=http://logi5.xiti.com/&amp;amp;HOSTIP=http://www.global-download.schneider-electric.com/&amp;amp;OTrSer=http://www.download.schneider-electric.com/&quot;&gt;&lt;span style=&quot;color: blue;&quot;&gt;HERE&lt;/span&gt;&lt;/a&gt;&amp;nbsp;AND THE APPLICATION WITH ETIC MODEMS &lt;u&gt;&lt;a href=&quot;http://www.global-download.schneider-electric.com/852575620060EFD9/all/852566B70073220C852569B600438925?OpenDocument&amp;amp;L=EL&amp;amp;p=537&amp;amp;idxUrl=repositoryGreece\\index.nsf&amp;amp;XID=225305&amp;amp;XHOST=http://logi5.xiti.com/&amp;amp;HOSTIP=http://www.global-download.schneider-electric.com/&amp;amp;OTrSer=http://www.download.schneider-electric.com/&quot;&gt;&lt;span style=&quot;color: blue;&quot;&gt;HERE&lt;/span&gt;&lt;/a&gt;&lt;/u&gt; &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;
The Application files make it possible to implement communications of telemaintenance &lt;br /&gt;
and dialogue inter PLCs&lt;br /&gt;
&lt;br /&gt;
In this application&amp;nbsp;2 modems MultiTech Systems - Model MT2834ZDXle was used &lt;br /&gt;
For more information on the specific modem manuals of multitech&lt;br /&gt;
&lt;a href=&quot;http://www.multitech.com//DOCUMENTS/manuals&quot;&gt;&lt;span style=&quot;color: blue;&quot;&gt;http://www.multitech.com//DOCUMENTS/manuals&lt;/span&gt;&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
The settings - The AT commands&amp;nbsp;that modems must have&amp;nbsp;are:&lt;br /&gt;
&lt;br /&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;u&gt;MODEM PLC&lt;/u&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;strong&gt;ATV1B0$SB9600$MB9600$EB0&amp;amp;E0&amp;amp;E10&amp;amp;E3&amp;amp;E14E0Q1&amp;amp;D0%DC1&amp;amp;W&lt;/strong&gt;&lt;br /&gt;
&lt;br /&gt;
These commands can be send to the modem of the PLC with a program to communicate with PC, like the HyperTerminal, ProComm, etc.&lt;br /&gt;
The connection&amp;nbsp;cable modem - PLC is TSXPCX1130&lt;br /&gt;
In the Hardware Configuration of PLC programming port should have selected the following.&lt;br /&gt;
&lt;br /&gt;
Unitelway Link&lt;br /&gt;
Type Master&lt;br /&gt;
8 Data Bits&lt;br /&gt;
1 Stop Bit&lt;br /&gt;
Parity None&lt;br /&gt;
Τransmision speed 9600 bit s/s&lt;br /&gt;
Wait time&amp;nbsp;between 100 – 200 ms. For example, 140ms.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhxghcCq7IAoga1UahhISuFc8tCJBarYXUSAmuC1Gmp9z0A7GFzaonRYkqH4lpkkQKx2AzNeFX-DgFJYSmF2AH9CH059XZDmuxTxLPutT3oNM2PAOA58oAcFT69xkeXPdeTSJSzXdPKc2QL/s1600/PLCPC1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhxghcCq7IAoga1UahhISuFc8tCJBarYXUSAmuC1Gmp9z0A7GFzaonRYkqH4lpkkQKx2AzNeFX-DgFJYSmF2AH9CH059XZDmuxTxLPutT3oNM2PAOA58oAcFT69xkeXPdeTSJSzXdPKc2QL/s400/PLCPC1.JPG&quot; height=&quot;290&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
﻿&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;strong&gt;&lt;u&gt;MODEM P.C&lt;/u&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;br /&gt;
At PC Unitelway Driver must be choosen &quot;Modem&quot;&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj7sg30zjO7dlupvhpftsV6tLxIN-1KwXusxzNWG6O8r7gqzQfgr8f7J4kyLTNdust2KnR6x9_sPsYJndTuJgWaalGpcF09xfVA2vMstNFlrhrsG60IMTflbD6ckcH_S5pHaMzRouzU1zrR/s1600/PLCPC2.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj7sg30zjO7dlupvhpftsV6tLxIN-1KwXusxzNWG6O8r7gqzQfgr8f7J4kyLTNdust2KnR6x9_sPsYJndTuJgWaalGpcF09xfVA2vMstNFlrhrsG60IMTflbD6ckcH_S5pHaMzRouzU1zrR/s400/PLCPC2.JPG&quot; height=&quot;336&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
The settings – HAYES Initialization are&lt;br /&gt;
&lt;br /&gt;
&lt;strong&gt;ATV1E0B0$EB0&amp;amp;E0&amp;amp;E3&amp;amp;D0&amp;amp;S0$SB9600$MB9600X1D%DC1&lt;/strong&gt;&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj0VcWpWwu76C4JrlLxbSb-Q4WEFUbVreC5RU8W0kgRXYtjjq7gZ4ijuEDl3S6B2LR0OjeXtLWgbInG63Ht8O3_e5Q8puLcAimA1J3GvkAIs_38pHkoriZFFa0a4PgRpi3cds8GeExkiaQM/s1600/PLCPC3.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj0VcWpWwu76C4JrlLxbSb-Q4WEFUbVreC5RU8W0kgRXYtjjq7gZ4ijuEDl3S6B2LR0OjeXtLWgbInG63Ht8O3_e5Q8puLcAimA1J3GvkAIs_38pHkoriZFFa0a4PgRpi3cds8GeExkiaQM/s400/PLCPC3.JPG&quot; height=&quot;102&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
At the &quot;Telephone Number&quot; put the number you want to call which is connected with the remote PLC &lt;br /&gt;
Becareful if a telephone center exist.&lt;br /&gt;
&lt;br /&gt;
With OK go back to the previous image, and select the menu&lt;br /&gt;
&lt;br /&gt;
FILE&amp;nbsp;-&amp;gt; ADVANCED CONFIGURATION having the following options.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgOhyphenhyphenIfMp8_swVOj9UJ13pfuX3hZiv3wopYEkzMmLbX0vrvRFyyc_M06MQzlXsTHeOJW6W61QfFsJijzXL0dQd4q1LR-i9F5HeLifxUD-HYg2nrNCOQC05XSyYd5maggwNx-kzl3yaKx3e-/s1600/PLCPC4.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgOhyphenhyphenIfMp8_swVOj9UJ13pfuX3hZiv3wopYEkzMmLbX0vrvRFyyc_M06MQzlXsTHeOJW6W61QfFsJijzXL0dQd4q1LR-i9F5HeLifxUD-HYg2nrNCOQC05XSyYd5maggwNx-kzl3yaKx3e-/s400/PLCPC4.JPG&quot; height=&quot;255&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
CAUTION: To be connected via modems with PL7 V4.1 &amp;amp; V4.2 should have the following drivers:&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
UNI-TELWAY Win2000/98 V1.4 IE08&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
UNI-TELWAY WinNT4 V1.8 IE15&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
UNI-TELWAY Win95/Dos V7.8 IE18&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
UNI-TELWAY Dos V7.4 IE14&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
Also, the use of the modem in conjunction with Magelis terminals from the port TER - AUX is not possible because the Magelis not respond by changing the Parity to None, in which case their combined use is impossible. For the solution of this problem must be&amp;nbsp;used a modem that has the ability to pass 11bits (8 data, 1start, 1stop, odd parity), so then you need to configure it according to instructions and commands given in the manual.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
A Modem which has the above feature is that of the company GENER.&lt;/div&gt;
(Schneider Alliance) model GENindus&lt;br /&gt;
For more information you can visit GENER site. &lt;a href=&quot;http://www.gener.fr/&quot;&gt;&lt;span style=&quot;color: blue;&quot;&gt;www.gener.fr&lt;/span&gt;&lt;/a&gt;&lt;br /&gt;
For more information about PLC manuals visit &lt;a href=&quot;http://www.schneider-electric.com/&quot;&gt;&lt;span style=&quot;color: blue;&quot;&gt;http://www.schneider-electric.com&lt;/span&gt;&lt;/a&gt; &amp;nbsp;site&lt;br /&gt;
&lt;br /&gt;
The above description could be&amp;nbsp;altered to newest versions of PL7 software and Unitelway Driver&lt;br /&gt;
It is the rensponibility of the developer to use the above. &lt;br /&gt;
&lt;u&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;Note: The recommended connection is that Schneider Electric Support and this document is&amp;nbsp;NOT a replacement of the official supported documents or modems&lt;/span&gt;&lt;/strong&gt;&lt;/u&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6564447908313575810'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6564447908313575810'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/11/plc-connection-with-pc-through-modems.html' title='MICRO TELEMECANIQUE P.L.C CONNECTION WITH PC THROUGH MODEMs - OLDER VERSION'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhxghcCq7IAoga1UahhISuFc8tCJBarYXUSAmuC1Gmp9z0A7GFzaonRYkqH4lpkkQKx2AzNeFX-DgFJYSmF2AH9CH059XZDmuxTxLPutT3oNM2PAOA58oAcFT69xkeXPdeTSJSzXdPKc2QL/s72-c/PLCPC1.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-8288822071947105043</id><published>2010-11-16T23:11:00.000+02:00</published><updated>2015-01-03T00:18:24.591+02:00</updated><title type='text'>MAGELIS TERMINAL ADDITION IN UNITELWAY NETWORK TO A SLAVE PLC</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Suppose we want to insert a Magelis terminal to a Slave PLC which is connected to a network Unitel-way. To the Slave PLC have given an address AD0, which is defined in the network. To be able to&amp;nbsp;connect the Magelis&amp;nbsp;at the&amp;nbsp;Slave PLC, do the following: Select the Menu Configuration&amp;nbsp;-&amp;gt; Equipment Symbols ... and get the following picture (Fig. 1), &lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgzXym7H9tOayMg3gDatdx7bVEPtcuYqG_xnpWxYcHVnv6d0TR0C5pvptyqc9sAex8_9hIQ_AEefQm_qfpocv1MuTSKx88wyXn8Yh3MY6VQ3dHUvIVhMPTHPgZoZexAga9bV8RkzgY2zUIF/s1600/Magelis1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgzXym7H9tOayMg3gDatdx7bVEPtcuYqG_xnpWxYcHVnv6d0TR0C5pvptyqc9sAex8_9hIQ_AEefQm_qfpocv1MuTSKx88wyXn8Yh3MY6VQ3dHUvIVhMPTHPgZoZexAga9bV8RkzgY2zUIF/s400/Magelis1.JPG&quot; height=&quot;278&quot; px=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
Select &lt;strong&gt;Modify&lt;/strong&gt; and displays the next image (Fig. 2) which will change the existing usual (0,254,0,254,0) which referred to the master PLC, and give one another Symbol name of your choice.&lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhcs5DDBtmqgx73xsXWAYfj6JMbrHSWmDlKIelbJDeH8D5zoOKtYRoxB2VgvJVcgRiJSf6tlm4_rgsjcyVH4thsT4RB3BZCT_V5UIrHSXPxVwtuIoVaxgAo4P_Ol_D76Z2rYEtleJRHJukm/s1600/Magelis2.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhcs5DDBtmqgx73xsXWAYfj6JMbrHSWmDlKIelbJDeH8D5zoOKtYRoxB2VgvJVcgRiJSf6tlm4_rgsjcyVH4thsT4RB3BZCT_V5UIrHSXPxVwtuIoVaxgAo4P_Ol_D76Z2rYEtleJRHJukm/s1600/Magelis2.JPG&quot; px=&quot;true&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
A&amp;nbsp;simple network Unitel-way without PCMCIA card is not feasible to achieve the connection because the number of Slave PLCs is limited. The&amp;nbsp;addition of two or more terminals Magelis consists networks using Unitel-way card PCMCIA RS485 (TSXSCP114) adjustable to 32 Stations (Magelis - PLC)&lt;br /&gt;
&lt;br /&gt;
﻿In addition the cable XBTZ968 which is used for the connection between Magelis and Slave PLC must be modified or added by a serial cable specially constructed taking in mind the Slave PLC address (it is recommended&amp;nbsp;to constructed a serial cable to added to the existing XBTZ968)&lt;br /&gt;
&lt;br /&gt;
For further information how to achieve the connection please contact &lt;br /&gt;
&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;http://kontactr.com/pics/small.gif&quot; height=&quot;16px&quot; width=&quot;90px&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/8288822071947105043'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/8288822071947105043'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/11/magelis-terminal-addition-in-unitelway.html' title='MAGELIS TERMINAL ADDITION IN UNITELWAY NETWORK TO A SLAVE PLC'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgzXym7H9tOayMg3gDatdx7bVEPtcuYqG_xnpWxYcHVnv6d0TR0C5pvptyqc9sAex8_9hIQ_AEefQm_qfpocv1MuTSKx88wyXn8Yh3MY6VQ3dHUvIVhMPTHPgZoZexAga9bV8RkzgY2zUIF/s72-c/Magelis1.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-290144870574430806</id><published>2010-10-26T21:10:00.000+03:00</published><updated>2015-01-03T00:18:35.044+02:00</updated><title type='text'>TWIDO ZELIOS &amp; TESYS LU9GC3</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Description: How to connect Twido with tesys and zelios using TESYS LU9GC3 under Modbus RS485&lt;br /&gt;
&lt;br /&gt;
In 1st picture there is the connection of a Twido modbus (any Twido model) &lt;br /&gt;
1 :&amp;nbsp;Modbus RS485 Communication module LULC031&lt;br /&gt;
2 :&amp;nbsp;Connection cable VW3A8308R with RJ45 connector on each end. Used to connect TESYS and distribution unit&lt;br /&gt;
3 : Modbus distribution unit LU9GC3. Used to connect the Twido and multi TESYS starter controllers via RJ45 connectors&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiEy0biZ0_kRvDOEXJUTgXs35lsYnuBtPdUf_r_J8mO9nb7IgWlWa_Q96voIm0pu9DFXJ-tqms0xqUIyxdrUS_t7kt4HVJ-Nm9FbLErS50gAOphx3YKAiAK90Yg684RR5tIS1c38Js4c99M/s1600/tesys.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiEy0biZ0_kRvDOEXJUTgXs35lsYnuBtPdUf_r_J8mO9nb7IgWlWa_Q96voIm0pu9DFXJ-tqms0xqUIyxdrUS_t7kt4HVJ-Nm9FbLErS50gAOphx3YKAiAK90Yg684RR5tIS1c38Js4c99M/s400/tesys.JPG&quot; height=&quot;156&quot; n4=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&amp;nbsp;The 2nd picture is showing the internal wiring of the modbus distribution unit &lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjB1-m5CnaAnLMk9xWa36K2kTjU6Ps7hrrfA7VECUvdNPK80DpFzWzeiR7ux4dFXbKTRDnQPfa03emiKGVq3CdBUHAqxjM4ZIxwSbOwgOFnfkW-uxu31oxwqm0ppDD1BUzkjEuNfx5kJwMP/s1600/internalTesys.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjB1-m5CnaAnLMk9xWa36K2kTjU6Ps7hrrfA7VECUvdNPK80DpFzWzeiR7ux4dFXbKTRDnQPfa03emiKGVq3CdBUHAqxjM4ZIxwSbOwgOFnfkW-uxu31oxwqm0ppDD1BUzkjEuNfx5kJwMP/s400/internalTesys.JPG&quot; height=&quot;400&quot; n4=&quot;true&quot; width=&quot;225&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div align=&quot;left&quot; class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: left;&quot;&gt;
The 3rd picture is showing how to connect&amp;nbsp; a Twido Master cpu with 2 or more (up to 29slaves) slave Zelios (internal wiring) using the modbus spliter box Tesys LU9GC3. The polarization resistor must be manage by the master. &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: left;&quot;&gt;
Note . Resistors of 4,7KΩ are implanted inside Twido CPU .&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgOOqovAHbvLJL8F3l44UJxNen_fNwh2QdrHnrYQsVFpbe23m8VvAXTsmTcm4ybwmANgNTOpC94vGVfd5ll3uQe06xga6cez7ZVElQWrWDlFaQQ1m3E-qFEM7PmjqBM5Ld-7U3Qtq-BCXrQ/s1600/tesys1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgOOqovAHbvLJL8F3l44UJxNen_fNwh2QdrHnrYQsVFpbe23m8VvAXTsmTcm4ybwmANgNTOpC94vGVfd5ll3uQe06xga6cez7ZVElQWrWDlFaQQ1m3E-qFEM7PmjqBM5Ld-7U3Qtq-BCXrQ/s400/tesys1.JPG&quot; height=&quot;201&quot; n4=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
﻿At the 4th picture is showing the above implementation on how to connect them in reality. The modules that are neccessary to implement this connection are : &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
1 :&amp;nbsp;One Twido master Cpu (any model)&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
2 :&amp;nbsp;Two (or more)&amp;nbsp;Zelios with their modbus extension module SR3MBU01BD&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
3 :&amp;nbsp;One Tesys LU9GC3 modbus RS485 distibution unit &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
4&amp;nbsp;: Two cables VW3A8306R03&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
5 : A connector unit VW3A8306TF03&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
6 : Two termination resistors VW3A8306RC&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjLuIu_xh4EC_hVhQkWiLDWIZ3SvKNLAwNJr6J2Cj1OWFCOP3twP6jXvdfMngBpXnTOUbZyq6-IiRVWG2IEmF69Fetpq0BM_3Kxq1SJjSKAI7KBrxwYdWgKSHWw5ZSO_GW2GCTOH2z6tVqO/s1600/tesys3new.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjLuIu_xh4EC_hVhQkWiLDWIZ3SvKNLAwNJr6J2Cj1OWFCOP3twP6jXvdfMngBpXnTOUbZyq6-IiRVWG2IEmF69Fetpq0BM_3Kxq1SJjSKAI7KBrxwYdWgKSHWw5ZSO_GW2GCTOH2z6tVqO/s400/tesys3new.JPG&quot; height=&quot;198&quot; n4=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
The implementation of the program&amp;nbsp;will be&amp;nbsp;added&amp;nbsp;soon or in a next post&amp;nbsp;&lt;/div&gt;
&lt;div align=&quot;left&quot; class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/290144870574430806'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/290144870574430806'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/10/twido-tesys-lu9gc3.html' title='TWIDO ZELIOS &amp; TESYS LU9GC3'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiEy0biZ0_kRvDOEXJUTgXs35lsYnuBtPdUf_r_J8mO9nb7IgWlWa_Q96voIm0pu9DFXJ-tqms0xqUIyxdrUS_t7kt4HVJ-Nm9FbLErS50gAOphx3YKAiAK90Yg684RR5tIS1c38Js4c99M/s72-c/tesys.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-1763992728109888550</id><published>2010-10-25T22:44:00.001+03:00</published><updated>2015-01-03T00:18:49.722+02:00</updated><title type='text'>Programming/animating Twido via existing RS485 bus.</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Description:&lt;br /&gt;
- This document describes the possibility to connect Twidosoft to Twido on existing RS485 bus for programming or monitoring purposes using Modbus communication protocol. Primary (built-in) or additional RS485 communication adapter may be used.&lt;br /&gt;
&lt;br /&gt;
Hardware&lt;br /&gt;
One or more Twido controllers (optionally with additional RS485 communication adapter installed.)&lt;br /&gt;
TSXPCX1031 serial programming cable Or TSXPCX3030 USB programming cable&lt;br /&gt;
mini-DIN female connector&lt;br /&gt;
Software&lt;br /&gt;
MS Windows XP SP1 / SP2&lt;br /&gt;
Twidosoft v3.2&lt;br /&gt;
Twido fw. 3.20&lt;br /&gt;
&lt;br /&gt;
1. Tested configuration&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSdegSTwlVDh6mTqfiGWcyVib4e33SiRlTMwoWq65zUUkCXGv9KFJ-t991-5LLJeElvXXrRjcq904LkewcH_o0aFcpG-xApG5Rk0w7nNJJnArCaTtnTFlBXlQjpPNkNAytGf8AenRP_0es/s1600/twidors485.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSdegSTwlVDh6mTqfiGWcyVib4e33SiRlTMwoWq65zUUkCXGv9KFJ-t991-5LLJeElvXXrRjcq904LkewcH_o0aFcpG-xApG5Rk0w7nNJJnArCaTtnTFlBXlQjpPNkNAytGf8AenRP_0es/s400/twidors485.JPG&quot; height=&quot;135&quot; nx=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
You will need an adapter (mini-DIN to free wires) in order to connect TSXPCX 1031/3030 programming cable to screw terminal block.&lt;br /&gt;
Adapter wiring:&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj2BS4UHWrttfcLO6kblsUrtf2qoHLV5XHMK0kkXIN2HPocQ9l46Ne7KZJujqEycovH_eAwN9hS3nwu2eXPegCLEB366CTdX-fhk9iv-m9__g_IPdrNGC3VXxl8uKfsbny9_ZWGiIxrLT7g/s1600/twidors4851.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj2BS4UHWrttfcLO6kblsUrtf2qoHLV5XHMK0kkXIN2HPocQ9l46Ne7KZJujqEycovH_eAwN9hS3nwu2eXPegCLEB366CTdX-fhk9iv-m9__g_IPdrNGC3VXxl8uKfsbny9_ZWGiIxrLT7g/s400/twidors4851.JPG&quot; height=&quot;177&quot; nx=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
Create an adapter using spare mini DIN female connector.&lt;br /&gt;
&lt;br /&gt;
Use pins 1, 2, 7 (data+, data-, GND). It’s necessary to connect external 5V DC power supply to pins 8 (5V) &amp;amp; 7 (GND) to supply the RS232&amp;lt;-&amp;gt;RS485 converter inside the cable. It’s possible to use 5V from PS/2, USB or Twido’s mini DIN connector&lt;br /&gt;
&lt;br /&gt;
Notes: -When connecting to Port 1, pins 5 (DPT) and 7 (0V - GND) must be interconnected, otherwise Twido sets the port for communication with Twidosoft (Address 1, 19200kb/s, no Parity) and ignores the user setting.&lt;br /&gt;
&lt;br /&gt;
-Other modbus devices than Twido may also be present on the network.&lt;br /&gt;
&lt;br /&gt;
2. Setting up connection in Twidosoft&lt;br /&gt;
&lt;br /&gt;
You will need to modify the connection preferences: File – Preferences – Connections Management&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhu1XO5Fi2nfU2dxzQZk2wRHJH9V6zE1ev5p5sUscbb4YpAPGA1o0su7s0FfGfH9G_UAw1O7QzL6TYJBsIb9oqJeJve2IKI6EwzZZF_0O-tQcHeYAlqVuK3rVF29A22cd8kdT2nSuLxVvm0/s1600/twidors4852.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhu1XO5Fi2nfU2dxzQZk2wRHJH9V6zE1ev5p5sUscbb4YpAPGA1o0su7s0FfGfH9G_UAw1O7QzL6TYJBsIb9oqJeJve2IKI6EwzZZF_0O-tQcHeYAlqVuK3rVF29A22cd8kdT2nSuLxVvm0/s400/twidors4852.JPG&quot; height=&quot;96&quot; nx=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
Connection type: Serial for TSXPCX1031 serial programming cable&lt;br /&gt;
USB for TSXPCX3030 USB programming cable&lt;br /&gt;
&lt;br /&gt;
IP / Phone: Corresponding COM or USB port&lt;br /&gt;
P-Unit / Address: @ - This setting lets you choose the address before every connection.&lt;br /&gt;
Baud rate, Parity, Stop Bits....: Use the exact setting of the network you wish to connect to.&lt;br /&gt;
Confirm the changes, select your connection from the drop-down menu and confirm again.&lt;br /&gt;
&lt;br /&gt;
3. Connection&lt;br /&gt;
&lt;br /&gt;
Set the rotary switch on programming cable into position 1 – OTHER MULTI.&lt;br /&gt;
Click on the connect button.&lt;br /&gt;
Select the address of PLC you want to connect to.&lt;br /&gt;
Confirm.&lt;br /&gt;
&lt;br /&gt;
Note: The line must be silent while connected with Twidosoft. If there is any other communication, the connection will fail.&lt;br /&gt;
This connection is not suitable for firmware update (possible only through Port 1 with default comm. setting). Communication failure would result in a permanent damage to the controller&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/1763992728109888550'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/1763992728109888550'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/10/programminganimating-twido-via-existing.html' title='Programming/animating Twido via existing RS485 bus.'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhSdegSTwlVDh6mTqfiGWcyVib4e33SiRlTMwoWq65zUUkCXGv9KFJ-t991-5LLJeElvXXrRjcq904LkewcH_o0aFcpG-xApG5Rk0w7nNJJnArCaTtnTFlBXlQjpPNkNAytGf8AenRP_0es/s72-c/twidors485.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-3132758095567221346</id><published>2010-10-17T19:08:00.001+03:00</published><updated>2015-01-03T00:19:21.542+02:00</updated><title type='text'>MONITOR PRO TAG COUNT CLARIFICATION</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Hardware Standard PC&lt;br /&gt;
Software MS Windows XP SP2&lt;br /&gt;
Monitor Pro 7.2&lt;br /&gt;
Monitor Pro 7.6&lt;br /&gt;
&lt;br /&gt;
&lt;span style=&quot;font-family: Arial; font-size: x-small;&quot;&gt;&lt;span style=&quot;font-family: Arial; font-size: x-small;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;strong&gt;MONITOR PRO 7.6&lt;/strong&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEheQkUB-SncHq9wCK3zyrYqoMsUuBXCttYlavEHd5PVAwTGEhNUzjSvFQtj3nKUTcQYDmkl_1Fc2Ti8HNP3DdOM9UVs4iIS1XQikHOJ_pmiX6wouwC7oCw3p2HGjuXdLHZIc3tCUUF7AIDv/s1600/MONITORPRO76.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEheQkUB-SncHq9wCK3zyrYqoMsUuBXCttYlavEHd5PVAwTGEhNUzjSvFQtj3nKUTcQYDmkl_1Fc2Ti8HNP3DdOM9UVs4iIS1XQikHOJ_pmiX6wouwC7oCw3p2HGjuXdLHZIc3tCUUF7AIDv/s400/MONITORPRO76.JPG&quot; ex=&quot;true&quot; height=&quot;308&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
The total tag count can be found by right-clicking on the application in&lt;br /&gt;
Config Explorer, slide down to &quot;View&quot; and then open &quot;Application Size&quot;.&lt;br /&gt;
This returns the total number of tags the app is configured for and the total&lt;br /&gt;
number of user defined tags.&lt;br /&gt;
The total tag count restriction on a Monitor Pro Server is based on the&lt;br /&gt;
user-defined tags. Schneider Electric defined global tags such as&lt;br /&gt;
SECTIME are not considered user defined tags are excluded from the total&lt;br /&gt;
user defined tag count limit.&lt;br /&gt;
e.g. If a customer has a 1024 total tag count license then he can have 1024&lt;br /&gt;
user defined tags.&lt;br /&gt;
I/O tags are defined by the number of tags entered in a device driver,&lt;br /&gt;
Ioxlator, or ECI table. It is not based on the number of registers addressed&lt;br /&gt;
in the PLC. For example, if you wants to read HREG 40001 into MyTag1&lt;br /&gt;
and into MyTag2, that counts as 2 I/O tags even though you are reading&lt;br /&gt;
from the same register in the PLC. In other words if the user defined 5 read&lt;br /&gt;
tables with 10 tags each in his netdtl driver table, then he has configured&lt;br /&gt;
50 I/O tags.&lt;br /&gt;
&lt;br /&gt;
&lt;div align=&quot;left&quot;&gt;
&lt;br /&gt;
&lt;strong&gt;MONITOR PRO 7.2&lt;/strong&gt;&lt;/div&gt;
&lt;div align=&quot;left&quot;&gt;
&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjSB1LCTSZA_cn97mUyofqNACL2Y-5e49N3Gcq_OQuvtUl5gIgcKcRzEk3jJjlOHi_PRiV884CAlsQlYeLs8TO1NF43vjT2fjtoL9WfxpmSUqBSTsSyuqVDaSepj8_YrEeaC5u1hA2sRGBo/s1600/MONITORpRO72.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;strong&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjSB1LCTSZA_cn97mUyofqNACL2Y-5e49N3Gcq_OQuvtUl5gIgcKcRzEk3jJjlOHi_PRiV884CAlsQlYeLs8TO1NF43vjT2fjtoL9WfxpmSUqBSTsSyuqVDaSepj8_YrEeaC5u1hA2sRGBo/s400/MONITORpRO72.JPG&quot; ex=&quot;true&quot; height=&quot;288&quot; width=&quot;400&quot; /&gt;&lt;/strong&gt;&lt;/a&gt;&lt;/div&gt;
&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;/div&gt;
&lt;/div&gt;
&lt;div align=&quot;left&quot;&gt;
&lt;/div&gt;
The total tag count can be found by right-clicking on the application in&lt;br /&gt;
Config Explorer, slide down to &quot;View&quot; and then open &quot;Application Size&quot;.&lt;br /&gt;
This returns the total number of tags the app is configured for and the total&lt;br /&gt;
number of user defined tags.&lt;br /&gt;
The total tag count restriction on a Monitor Pro Server is based on the&lt;br /&gt;
user-defined tags. Schneider Electric defined global tags such as&lt;br /&gt;
SECTIME are not considered user defined tags are excluded from the total&lt;br /&gt;
user defined tag count limit.&lt;br /&gt;
e.g. If a customer has a 1024 total tag count license then he can have 1024&lt;br /&gt;
user defined tags.&lt;br /&gt;
I/O tags are defined by the number of tags entered in a device driver,&lt;br /&gt;
Ioxlator, or ECI table. It is not based on the number of registers addressed&lt;br /&gt;
in the PLC. For example, if you wants to read HREG 40001 into MyTag1&lt;br /&gt;
and into MyTag2, that counts as 2 I/O tags even though you are reading&lt;br /&gt;
from the same register in the PLC. In other words if the user defined 5 read&lt;br /&gt;
tables with 10 tags each in his netdtl driver table, then he has configured&lt;br /&gt;
50 I/O tags.&lt;br /&gt;
Unfortunately no tool exists to display the I/O tag count. The user has to&lt;br /&gt;
manually count his I/O entries.&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3132758095567221346'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3132758095567221346'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/10/monitor-pro-tag-count-clarification.html' title='MONITOR PRO TAG COUNT CLARIFICATION'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEheQkUB-SncHq9wCK3zyrYqoMsUuBXCttYlavEHd5PVAwTGEhNUzjSvFQtj3nKUTcQYDmkl_1Fc2Ti8HNP3DdOM9UVs4iIS1XQikHOJ_pmiX6wouwC7oCw3p2HGjuXdLHZIc3tCUUF7AIDv/s72-c/MONITORPRO76.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-4393411853817784743</id><published>2010-09-30T17:33:00.001+03:00</published><updated>2015-01-03T00:19:33.457+02:00</updated><title type='text'>ConneXium Ethernet Gateway TSXETG100</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj8ohA7D2kFVMXUd24q54gFLCEAFY99_zr4lhBUxQKkskobs7zrpp5rHgcG3OJl1Xtq-FjQPfYXTkB2MpYX8ZeXAYn7B5AQkpeggeVYwM6i1ZzKvqhH_zryeATT3eQ5iFO0usjtn1WRGNCv/s1600/TSXEtg100.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj8ohA7D2kFVMXUd24q54gFLCEAFY99_zr4lhBUxQKkskobs7zrpp5rHgcG3OJl1Xtq-FjQPfYXTkB2MpYX8ZeXAYn7B5AQkpeggeVYwM6i1ZzKvqhH_zryeATT3eQ5iFO0usjtn1WRGNCv/s320/TSXEtg100.JPG&quot; height=&quot;320&quot; px=&quot;true&quot; width=&quot;312&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
Mount the unit.&lt;br /&gt;
&lt;br /&gt;
❏ Determine the control power method and connect the power.&lt;br /&gt;
❏ Configure the Ethernet communications settings with a web browser (using an Ethernet crossover&lt;br /&gt;
cable) or with HyperTerminal (using a null modem cable, which is included in the TCSEAK0100&lt;br /&gt;
configuration kit [sold separately]).&lt;br /&gt;
❏ Configure the serial ports.&lt;br /&gt;
❏ Configure the device list.&lt;br /&gt;
❏ Wire the serial ports.&lt;br /&gt;
&lt;br /&gt;
&lt;strong&gt;DESCRIPTION&lt;/strong&gt;&lt;br /&gt;
&lt;br /&gt;
1. 24 Vdc control power connection&lt;br /&gt;
2. 10/100BaseTx (802.3af) connection&lt;br /&gt;
3. LEDs:&lt;br /&gt;
&lt;br /&gt;
Ethernet:&lt;br /&gt;
• LK: Active link&lt;br /&gt;
• TX: Transmitting data&lt;br /&gt;
• RX: Receiving data&lt;br /&gt;
• 100: Link speed. 100 Mb = ON, 10 Mb = OFF&lt;br /&gt;
&lt;br /&gt;
Serial:&lt;br /&gt;
• RS485: RS485 mode = ON, RS232 mode = OFF&lt;br /&gt;
• TX: Transmitting data&lt;br /&gt;
• RX: Receiving data&lt;br /&gt;
&lt;br /&gt;
Power/Status&lt;br /&gt;
4. DIN rail release&lt;br /&gt;
5. Reset button (press to reboot the ETG; no data is lost)&lt;br /&gt;
6. RS485 connection&lt;br /&gt;
7. Dip switches&lt;br /&gt;
8. RS232 connection&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh5X8f8Mdc7IRSIkAN3J9MGoGK7anAw0_qmGrZ3SjpnVQJcbUMAweJxkuqSEv6vugiuK4V_5l2FXl-uZtmgq6PGHOoKzhFwNf4ugnj9SEYoTIPuuNG8eOavu8D_mAuiAWesVLmus7lSSTGS/s1600/Table1.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh5X8f8Mdc7IRSIkAN3J9MGoGK7anAw0_qmGrZ3SjpnVQJcbUMAweJxkuqSEv6vugiuK4V_5l2FXl-uZtmgq6PGHOoKzhFwNf4ugnj9SEYoTIPuuNG8eOavu8D_mAuiAWesVLmus7lSSTGS/s400/Table1.JPG&quot; height=&quot;248&quot; px=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;Ethernet Setup Using HyperTerminal&lt;/span&gt;&lt;/strong&gt;&lt;/div&gt;
&lt;br /&gt;
1. Attach a null modem cable (see below).&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
NOTE: The RJ45 to DB9 adapter and the Ethernet crossover cable are included in the &lt;br /&gt;
TCSEAK0100 configuration kit &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj6Hx_zI_5m2GwK8jUuteFSXEOq1SiJsS3rQfjI-Lk1Hln79vDFKpeUcISAqZ6hYEHOivajkf2-lF7_d24GYYZwSpTOM0F9oOgycmUxq55uPEuzPTbToCujwzDOEapujHS70VMhqSJ4HsDp/s1600/Connexium.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj6Hx_zI_5m2GwK8jUuteFSXEOq1SiJsS3rQfjI-Lk1Hln79vDFKpeUcISAqZ6hYEHOivajkf2-lF7_d24GYYZwSpTOM0F9oOgycmUxq55uPEuzPTbToCujwzDOEapujHS70VMhqSJ4HsDp/s400/Connexium.JPG&quot; height=&quot;180&quot; px=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
2. Click Start &amp;gt; Run, then type hypertrm.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
3. In the Name text box, type a name for the new connection (for example, ETG config), then click OK.&lt;/div&gt;
4. In the Connect using drop-down list box, select the computer COM port you will be using, then click OK.﻿&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
5. Set the COM properties as follows: Bits per second = 19200, Data bits = 8, Parity = None, Stop bits =1, and Flow control = None.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
6. Click OK.&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
7. Start the ETG Setup Utility:&lt;/div&gt;
a. Cycle power or press the reset button on the ETG.&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
b. While the green Power/Status LED blinks rapidly, press Enter on the computer keyboard to access&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
the setup utility. See Table 2 for a description of the setup options.&lt;/div&gt;
A B NOTE: The Power/Status LED stops blinking after 5 seconds.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi6xnNEHStvdj2_7mijBZfMhnx74yHSTue4PxycSrUVPrAMZI6eE_RWcvnatdkWVKVMhG2w2GigQU84dR3JQswtXBDt0KmHsXdCzPnVF2toRuKSA3wgYcaJ8Ou16b7GyDOTTXFA_8NKa0tq/s1600/table2.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi6xnNEHStvdj2_7mijBZfMhnx74yHSTue4PxycSrUVPrAMZI6eE_RWcvnatdkWVKVMhG2w2GigQU84dR3JQswtXBDt0KmHsXdCzPnVF2toRuKSA3wgYcaJ8Ou16b7GyDOTTXFA_8NKa0tq/s400/table2.JPG&quot; height=&quot;280&quot; px=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div align=&quot;left&quot;&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgkOwr2cvJk5Dc8DdLCAfutbL-6LQSOxPvu3NaCq55LJLOpppSsFghyphenhyphen_zm0ZsOx140Fhs5R-Bt7TL_aVkc8_XlkjvXfpaKT4Gps8QTDl3qmHt_H-YfXLcKJQMWsJkFcT27_RNTgBlsrGq8G/s1600/tabl3_4.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgkOwr2cvJk5Dc8DdLCAfutbL-6LQSOxPvu3NaCq55LJLOpppSsFghyphenhyphen_zm0ZsOx140Fhs5R-Bt7TL_aVkc8_XlkjvXfpaKT4Gps8QTDl3qmHt_H-YfXLcKJQMWsJkFcT27_RNTgBlsrGq8G/s400/tabl3_4.JPG&quot; height=&quot;308&quot; px=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;RS232 Serial Port&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;
&lt;br /&gt;
NOTE: The ETG pinout for the RJ45 (RS232) is compliant with the EIA/TIA-561 standard. &lt;br /&gt;
To ensure proper connections with other Schneider Electric products, examine the wiring for each device. See the wiring instructions on the ETG100 Technical Library CD for more information, &lt;br /&gt;
or contact your local Schneider Electric support representative.&lt;br /&gt;
&lt;br /&gt;
The RS232 port is used to configure the ETG network parameters, and also can be used for serial&lt;br /&gt;
communication using Modbus. The ETG RS232 port is wired as a data terminal equipment (DTE) &lt;br /&gt;
device and uses a standard RJ45 connector.&lt;br /&gt;
&lt;br /&gt;
NOTE: An RJ45 to DB9 adapter is included in the TCSEAK0100 configuration kit (sold separately) &lt;br /&gt;
for use with an Ethernet crossover cable.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg0UzLvha1gRwEPtM05dg7Z3vZgXBhAnXluLhwbVpSrrxR-y9DtLdrac_ODFfh7HoYto8CYxnGIxgkks_n_cnkwBd65jr9isLXt2zlcEBmHQnaPX8ejhr1ZMLij8X1feZZxMEV4CvGT7MRf/s1600/table5.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg0UzLvha1gRwEPtM05dg7Z3vZgXBhAnXluLhwbVpSrrxR-y9DtLdrac_ODFfh7HoYto8CYxnGIxgkks_n_cnkwBd65jr9isLXt2zlcEBmHQnaPX8ejhr1ZMLij8X1feZZxMEV4CvGT7MRf/s400/table5.JPG&quot; height=&quot;152&quot; px=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEim-EnNf1nFCtYpE1ueZQumrHi5ANBfts6EI9KtM8_N_J9xj68rga7sbptV3pm-VhvuzOu_dwXDlxNtp-iWTgPHdp2yLW_9O6EHN7C-Y_LhUXDI9v8tvkv9jKTr6TaAtwlS6_dpJcpdd-un/s1600/table6.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEim-EnNf1nFCtYpE1ueZQumrHi5ANBfts6EI9KtM8_N_J9xj68rga7sbptV3pm-VhvuzOu_dwXDlxNtp-iWTgPHdp2yLW_9O6EHN7C-Y_LhUXDI9v8tvkv9jKTr6TaAtwlS6_dpJcpdd-un/s400/table6.JPG&quot; height=&quot;400&quot; px=&quot;true&quot; width=&quot;382&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/4393411853817784743'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/4393411853817784743'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/09/connexium-ethernet-gateway-tsxetg100.html' title='ConneXium Ethernet Gateway TSXETG100'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj8ohA7D2kFVMXUd24q54gFLCEAFY99_zr4lhBUxQKkskobs7zrpp5rHgcG3OJl1Xtq-FjQPfYXTkB2MpYX8ZeXAYn7B5AQkpeggeVYwM6i1ZzKvqhH_zryeATT3eQ5iFO0usjtn1WRGNCv/s72-c/TSXEtg100.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-6387129853585843252</id><published>2010-09-28T18:00:00.092+03:00</published><updated>2015-01-03T00:19:41.460+02:00</updated><title type='text'>VIJEO LOOK V2.6 FULL UNINSTALL</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
The Puprose of this&amp;nbsp;post is to provide information how to &lt;br /&gt;
perform full uninstall or how to reinstall Vijeo Look software.&lt;br /&gt;
Standard PC with the Vijeo Look V2.6 requirements with MS Windows XP SP2&lt;br /&gt;
Vijeo Look 2.6 (any package tags size)&lt;br /&gt;
&amp;nbsp; &lt;br /&gt;
It could happen that Vijeo Look software package is corrupted and must be reinstalled. To perform reinstallation&amp;nbsp;you have to uninstall all software components and manually delete few files located on “C:” drive like “Vijeo Look”, “OFS” folders&amp;nbsp;in the “Program Files” folder, and windows registry keys.&amp;nbsp; &lt;br /&gt;
&lt;br /&gt;
Before doing uninstallation first is mandatory to backup your current license to USB Flash Disk.&lt;br /&gt;
Then launch Start-&amp;gt;Control Panel-&amp;gt;Add or Remove Programs and uninstall following components:&lt;br /&gt;
Vijeo Look V2.6 &lt;br /&gt;
SA PLC USB Driver&lt;br /&gt;
SA MODBUS Driver&lt;br /&gt;
SA UNITELWAY WDM Driver&lt;br /&gt;
SA Driver Manager&lt;br /&gt;
OPC Factory Server&lt;br /&gt;
OFS Configuration Tool&lt;br /&gt;
Microsoft SQL Server Desktop Engine&lt;br /&gt;
Microsoft .NET Framework 1.1 (including all language packs)&lt;br /&gt;
Java 2 Runtime Environment Standard Edition&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjJ1yggpB4Ecuya6evl5c2riUYRDVhQ6AvsMqML_6kCKeAwNb57DgtNffo6t2GMzAr6Yr49nbbCIts6FTEenBY4PovX5qeKtaQDhjNsxAAMGXNSsYluGUPVE8SoC8PyEWUTB-_aaYXXbQEW/s1600/vijeo.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;215&quot; r6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjJ1yggpB4Ecuya6evl5c2riUYRDVhQ6AvsMqML_6kCKeAwNb57DgtNffo6t2GMzAr6Yr49nbbCIts6FTEenBY4PovX5qeKtaQDhjNsxAAMGXNSsYluGUPVE8SoC8PyEWUTB-_aaYXXbQEW/s400/vijeo.jpg&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
The following picture could see the drivers to be uninstall&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieSwOCg_04_9dYnYuurOpzdRgMKng4o1FjcKti8PPyA_2NeykvCJdA32zLIsG-rPQh3HEWqwOKTmnNbz0MzuZGg3xW4x75HZgM-aBXGWbNZFel0_BwO4hZiAaNG-BEm0UTJSFlJJ6Lj4gn/s1600/Drivers_Install.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;216&quot; r6=&quot;true&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEieSwOCg_04_9dYnYuurOpzdRgMKng4o1FjcKti8PPyA_2NeykvCJdA32zLIsG-rPQh3HEWqwOKTmnNbz0MzuZGg3xW4x75HZgM-aBXGWbNZFel0_BwO4hZiAaNG-BEm0UTJSFlJJ6Lj4gn/s400/Drivers_Install.JPG&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
And so on....After unistallation of all packages, restart the PC. &lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
Then delete manually following folders if still exist:&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
C:\Program Files\Schneider Electric\Vijeo Look&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
C:\Program Files\Schneider Electric\OFS&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
C:\Program Files\Schneider Electric\Database Manager&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
Launch Windows Regedit and delete following entries:&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
HKEY_LOCAL_MACHINE\SOFTWARE\Schneider electric\Vijeo Look&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
HKEY_LOCAL_MACHINE\SOFTWARE\Schneider Electric\OFS&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
HKEY_LOCAL_MACHINE\SOFTWARE\Schneider Electric\CDOFS&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
HKEY_LOCAL_MACHINE\SOFTWARE\Schneider Automation SAS\OFS Configuration Tool&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
HKEY_LOCAL_MACHINE\SOFTWARE\Schneider Automation SAS\OPC Factory Server&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
Delete manually all files that fit following masks (where “?” means any character) and are located in c:\windows\ folder&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
164???s&lt;/div&gt;
169???s&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&lt;br /&gt;
Vijeo Look is fully uninstalled now.&lt;/div&gt;
&lt;br /&gt;
If you would like to install Vijeo Look again, you can continue as described:&lt;br /&gt;
&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none;&quot;&gt;
&amp;nbsp;Start the standard installation procedure.&lt;/div&gt;
After Vijeo Look installation you must launch “Vijeo Look” before you will start other programs (Registration Tool, OPC Factory Server,OFS Configuration Tool or others).&lt;br /&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; text-align: left;&quot;&gt;
You can restore your license using Vijeo Look Registration Tool. &lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; text-align: left;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; text-align: left;&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;&lt;u&gt;NOTE&lt;/u&gt; : This is for educational purpose only &lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; text-align: left;&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;This procedure describe how to uninstall Vijeo Look V2.6 from the PC. &lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;This is &lt;/strong&gt;&lt;/span&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;not a recommendation of official Schneider Electric manuals &lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;on how to install &lt;/strong&gt;&lt;/span&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;or uninstall Vijeo Look V2.6 &lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; text-align: left;&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;The user must has knowledge on PC registry to delete the proper entries that described. &lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;
&lt;div style=&quot;border-bottom: medium none; border-left: medium none; border-right: medium none; border-top: medium none; text-align: left;&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;Failure or wrong entries deleted may corrupt the PC registry which&amp;nbsp;could&amp;nbsp;result in a PC malfunction&lt;/strong&gt;&lt;/span&gt;.&lt;/div&gt;
&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6387129853585843252'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/6387129853585843252'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/09/vijeo-look-v26-full-uninstall_28.html' title='VIJEO LOOK V2.6 FULL UNINSTALL'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjJ1yggpB4Ecuya6evl5c2riUYRDVhQ6AvsMqML_6kCKeAwNb57DgtNffo6t2GMzAr6Yr49nbbCIts6FTEenBY4PovX5qeKtaQDhjNsxAAMGXNSsYluGUPVE8SoC8PyEWUTB-_aaYXXbQEW/s72-c/vijeo.jpg" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-1311859127131661824</id><published>2010-09-11T19:05:00.001+03:00</published><updated>2015-01-03T00:20:14.295+02:00</updated><title type='text'>TWIDO with CANopen multi turn Encoder</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
This&amp;nbsp;example describes configuration of Twido PLC with Osicoder XCC-3510PS84CB CANopen multi-turn absolute encoder.&lt;br /&gt;
&lt;br /&gt;
Hardware Any Twido controller except&lt;br /&gt;
TWDLC•A1•DRF&lt;br /&gt;
&lt;br /&gt;
TWDNCO1M CANopen master SV2.0&lt;br /&gt;
Osicoder XCC-3510PS84CB Absolute&lt;br /&gt;
CANopen encoder&lt;br /&gt;
Software Twidosoft 3.5&lt;br /&gt;
Windows XP SP2&lt;br /&gt;
&lt;br /&gt;
1. Tested configuration&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgynZA8y23bU3Zr5PKfrmzRN2-1YmATiEKzSP0oweQ-mHIeGFYSlOI1NMbWmWim7M6DyYF4YTe0aGTZetTVwiucRhvWq43Xd4XxPKGSkc4FhY5qtQUWLYueQmcUwUTbRupQplOra92JCBWp/s1600/Twidoencoderf.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgynZA8y23bU3Zr5PKfrmzRN2-1YmATiEKzSP0oweQ-mHIeGFYSlOI1NMbWmWim7M6DyYF4YTe0aGTZetTVwiucRhvWq43Xd4XxPKGSkc4FhY5qtQUWLYueQmcUwUTbRupQplOra92JCBWp/s400/Twidoencoderf.JPG&quot; height=&quot;177&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
2. Features&lt;br /&gt;
&lt;br /&gt;
XCC-3510PS84CB in default configuration sends information about actual position on reception of synchronisation message.&lt;br /&gt;
Twido CANopen master doesn’t support SYNC object. Therefore it’s necessary to switch XCC-3510PS84CB to send information about position cyclically. This is done by writing a value in milliseconds to 16bit object 6200h sub0 (Cyclic timer). That makes the encoder send position value with selected period ranging from 1 to 65535ms.Writing of Cyclic timer value is done via Service Data Object (SDO). It requires a communication table to be created in internal memory of Twido and then sent using CAN_CMDx command. It’s necessary to repeat this procedure after every power cycle of Twido and/or encoder.&lt;br /&gt;
&lt;br /&gt;
REQUEST for the code to &lt;a href=&quot;mailto:jupiter071@gmail.com&quot;&gt;&lt;span style=&quot;color: red;&quot;&gt;jupiter071@gmail.com&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/1311859127131661824'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/1311859127131661824'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/09/twido-with-canopen-multi-turn-encoder.html' title='TWIDO with CANopen multi turn Encoder'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgynZA8y23bU3Zr5PKfrmzRN2-1YmATiEKzSP0oweQ-mHIeGFYSlOI1NMbWmWim7M6DyYF4YTe0aGTZetTVwiucRhvWq43Xd4XxPKGSkc4FhY5qtQUWLYueQmcUwUTbRupQplOra92JCBWp/s72-c/Twidoencoderf.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-3978496484513820716</id><published>2010-09-09T22:25:00.000+03:00</published><updated>2015-01-03T00:20:28.350+02:00</updated><title type='text'>CONNECTING PLC WITH GSM MODEM FOR ALARM ANNOUNCEMENT</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;ASSOCIATION PLC&amp;nbsp;WITH GSM-MODEM&lt;/span&gt;&lt;/strong&gt; &lt;br /&gt;
&lt;br /&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;SMS MISSION FOR ERRORS&amp;nbsp;REPORT&lt;/strong&gt;&lt;/span&gt; &lt;br /&gt;
&lt;br /&gt;
How can we have remotely, when&amp;nbsp;an&amp;nbsp;alarm&amp;nbsp;happens, the&amp;nbsp;report of&amp;nbsp;the error&amp;nbsp;in the installation? &lt;br /&gt;
Simply, by sending an SMS message alarm from PLC in our mobile. &lt;br /&gt;
&lt;br /&gt;
Below we describe the logic and message sending,&amp;nbsp;reporting an&amp;nbsp;error. &lt;br /&gt;
&lt;br /&gt;
The&amp;nbsp;SmsAlarm.stx program shows us how can we send SMS and find errors. In this program we are able to recognize only three errors, for example. Of course we can identify more, and that depends on the application and severity of errors (Alarms). It is in the hands of each developer to create in the&amp;nbsp;PLC a database-constants, which correspond to specific error-Alarms. &lt;br /&gt;
&lt;br /&gt;
Also this example is not binding, except the codes to send in GSM - MODEM to send the SMS message. Thus it can be changed depending on the application except for certain items to be analyzed. &lt;br /&gt;
&lt;br /&gt;
The application has been made on a series PLC MICRO TSX37. Communication with the GSM MODEM is through the cable programming TSXPCX1031 with the trimmer in option 3. We also need an additional cable, which you must build yourself, but it is very simple. &lt;br /&gt;
On the side of GSM - MODEM a male connector VGA 15-pin must be used, while on the side of the PLC, to connect the cable TSXPCX1031 must&amp;nbsp;be used&amp;nbsp;a male serial connector 9-pin, and the connections are: &lt;br /&gt;
&lt;br /&gt;
9 – pin 15 – pin&lt;br /&gt;
&lt;br /&gt;
5&amp;nbsp;&amp;lt;--&amp;gt;&amp;nbsp;9&lt;br /&gt;
&lt;br /&gt;
3 &amp;lt;--&amp;gt;&amp;nbsp;6&lt;br /&gt;
&lt;br /&gt;
2&amp;nbsp;&amp;lt;--&amp;gt;&amp;nbsp;2&lt;br /&gt;
&lt;br /&gt;
So Simple &lt;br /&gt;
&lt;br /&gt;
The GSM - MODEM that we have chosen is from the company WAVECOM &lt;br /&gt;
The model has code order WMOD2B - M1203A. For anyone interested in more information , on the Site Wavecom.com, can find the manual of the product. &lt;br /&gt;
&lt;br /&gt;
The program distinguish two PRINT_CHAR&amp;nbsp;commands. &lt;br /&gt;
&lt;br /&gt;
In the first command &lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjI0KJS-3Op5-jGWGNzbIQRewjn1gG9B4yYeUvrH-QvXdd44fQtRbMVDav1B52RVWm8DfNnDKa3Hzi0Lg-NVMck_-pc7-FYwt2RpcC2krxMOsufON7TJEO4RusBMNaZYjbymeVX0dmLjaMW/s1600/100.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjI0KJS-3Op5-jGWGNzbIQRewjn1gG9B4yYeUvrH-QvXdd44fQtRbMVDav1B52RVWm8DfNnDKa3Hzi0Lg-NVMck_-pc7-FYwt2RpcC2krxMOsufON7TJEO4RusBMNaZYjbymeVX0dmLjaMW/s400/100.JPG&quot; height=&quot;22&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
After selecting a channel in the PLC, (ADR # 0.0.SYS - From TER) the code AT + CMGS is the command necessary for the GSM - MODEM, to send SMS, while the numbers where&amp;nbsp;are between &quot;&amp;nbsp; &quot; is the number of mobile in which we send out the SMS. The Code $R (CR = 0D - Ascii Hex) is the Return. &lt;br /&gt;
The % MW120: 4 is the reference words for communication, which you can change. &lt;br /&gt;
&lt;br /&gt;
NOTE: The channel selection (ADR # 0.0.SYS - From TER),&amp;nbsp;the code, the phone number, and the code $R is absolutely binding and must be placed exactly as you can see them in the command. &lt;br /&gt;
&lt;br /&gt;
In the second command, and after a delay of 500ms (TP = 500ms) as noted in the program &lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh_xMv5hHJrwNS7sfbcdk3w6WNMUjsWyZe4Y7htvXVmIVqpXAnZKU7Q_5IyvDf_FKApCXxqjPPFApSqxgR0V0FpC4Wqp4kr9UeMgDlyfehzCJuyv7QVQiVjgNkJ8wZgZ5tAwuvnA8ffKcLf/s1600/100.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh_xMv5hHJrwNS7sfbcdk3w6WNMUjsWyZe4Y7htvXVmIVqpXAnZKU7Q_5IyvDf_FKApCXxqjPPFApSqxgR0V0FpC4Wqp4kr9UeMgDlyfehzCJuyv7QVQiVjgNkJ8wZgZ5tAwuvnA8ffKcLf/s400/100.JPG&quot; height=&quot;27&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
The %MB200: 20 is equivalent to %MW100: 10. In these words, placed as seen in the program, the initial&amp;nbsp;commands &amp;nbsp;(the&amp;nbsp;command Operate), the constants&amp;nbsp;describe the current message that we want to send. That&amp;nbsp;we&amp;nbsp;putting&amp;nbsp;in %KWs the message we want to send (from the Application Browser select Variables--&amp;gt; Constants --&amp;gt; Words). Caution should be taken, each character must be written with the corresponding HEX code from the ASCII table. Something else to&amp;nbsp;pay attention, is that we must engage a specific length of characters and must in the end of each message to devote a %MW to write the code 16#1A00, which &lt;ctrl-z iex=&quot;&quot;&gt;is necessary to convey the message (close this message). &lt;br /&gt;
&lt;br /&gt;
Also in the Hardware Configuration of the PLC in COMMs must be chosen for the Channel 0 &quot;Character Mode&quot; as shown in the program. &lt;br /&gt;
&lt;br /&gt;
&amp;nbsp;Care must be taken from the developer in every application the code used. It is the rensponsibility of the developer to use the code properly in his application&lt;br /&gt;
&lt;br /&gt;
You could&amp;nbsp;REQUEST for&amp;nbsp;the code &lt;br /&gt;
&lt;a href=&quot;http://kontactr.com/user/jup71&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;http://kontactr.com/pics/small.gif&quot; height=&quot;16px&quot; width=&quot;90px&quot; /&gt;&lt;/a&gt;&lt;/ctrl-z&gt;&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3978496484513820716'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3978496484513820716'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/09/association-plc-gsm-modem-sms-mission.html' title='CONNECTING PLC WITH GSM MODEM FOR ALARM ANNOUNCEMENT'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjI0KJS-3Op5-jGWGNzbIQRewjn1gG9B4yYeUvrH-QvXdd44fQtRbMVDav1B52RVWm8DfNnDKa3Hzi0Lg-NVMck_-pc7-FYwt2RpcC2krxMOsufON7TJEO4RusBMNaZYjbymeVX0dmLjaMW/s72-c/100.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-5761495221697964405</id><published>2010-08-19T22:06:00.000+03:00</published><updated>2015-01-03T00:20:47.518+02:00</updated><title type='text'>UNITELWAY NETWORK</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;u&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;UNITELWAY NETWORK&lt;/span&gt;&lt;/strong&gt;&lt;/u&gt;&lt;/div&gt;
&lt;br /&gt;
Suppose we want to exchange information between two PLCs via network UNITELWAY. The following figure (Fig.1) shows a circuit of both PLC.&amp;nbsp;Two TSXPACC01 placed to protect the TER entrances&amp;nbsp;of each PLC by exogenous risk factors (hypertension, overvoltage etc.) and are very necessary&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixTozYpBcpnLFmYTHUgRVIw_tRcsSZyDyTQzzDiZGXSEzFDBObpIwexSjzfYW2zHY1ryJVsp4PwdRyv841d7b1A1rbYwW61AqSFnWt7m96ZIq8ind7R3DVuRh8H5v7f00YcJoL_mkNq8gK/s1600/40.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixTozYpBcpnLFmYTHUgRVIw_tRcsSZyDyTQzzDiZGXSEzFDBObpIwexSjzfYW2zHY1ryJVsp4PwdRyv841d7b1A1rbYwW61AqSFnWt7m96ZIq8ind7R3DVuRh8H5v7f00YcJoL_mkNq8gK/s400/40.JPG&quot; height=&quot;298&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
Figure 1&lt;/div&gt;
&lt;br /&gt;
At the following figure (Fig.2), we can see the configuration needed to addressing the 1st PLC &lt;br /&gt;
This picture listed for the Master PLC. To display the image below, do the following steps: &lt;br /&gt;
In the PL7 Application Browser, application has already created, select Configuration&amp;nbsp;--&amp;gt;&lt;br /&gt;
Hardware Configuration. &lt;br /&gt;
The Hardware appears and double-click on the shape of the TER which is displayed below the image. &lt;br /&gt;
In&amp;nbsp;option &quot;select CHANNEL&quot; select CHANNEL 0. &lt;br /&gt;
If PLC&amp;nbsp;PCMCIA card is installed and we want to use it then select CHANNEL 1. &lt;br /&gt;
Next&amp;nbsp;choose the type of communication that used, in this case UniTelWay. &lt;br /&gt;
Then choose the&amp;nbsp;&quot;Type&quot; --&amp;gt;&amp;nbsp;Type Master. &lt;br /&gt;
Below the latter option see this option &quot;Number of slaves&quot; = 8 indicating the number of Slave PLC, from 4 to 8 Addresses Slaves. (A PLC can&amp;nbsp;have&amp;nbsp;from 1 to 3&amp;nbsp;addresses depending on the application. The position 0 is bound by the Master CPU, and the 1,2,3&amp;nbsp; for a device programmer (eg PC) . &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjkaMCH75uySgfaRZznJyQhybrE3QvGcf_2ARiMaq9Gr3-MbQqns807Wfh21k6rQnDY4bC1g48tZRmoEYLKBDU_A_ewQF2EfViwCROfofKcmVSt-XyCfAmKrigD1P65HXJOSOH8I8fWKf1d/s1600/41.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjkaMCH75uySgfaRZznJyQhybrE3QvGcf_2ARiMaq9Gr3-MbQqns807Wfh21k6rQnDY4bC1g48tZRmoEYLKBDU_A_ewQF2EfViwCROfofKcmVSt-XyCfAmKrigD1P65HXJOSOH8I8fWKf1d/s400/41.JPG&quot; height=&quot;286&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
Figure 2&lt;/div&gt;
&lt;br /&gt;
Whole can be connected up to 5 Slave PLC, but if you connect a Magelis terminal, then limited to 3 Slave PLCs, because Magelis binds 2 Addresses. &lt;br /&gt;
If you use PCMCIA card then the total number of Slave addresses is about 98. &lt;br /&gt;
Below we see Figure 3, which refers to the Slave PLC. &lt;br /&gt;
We make the same&amp;nbsp;adjustments&amp;nbsp;but&amp;nbsp;also&amp;nbsp;set the option &quot;Server Address AD0&quot; to&amp;nbsp;6.&lt;br /&gt;
It is best to begin the addressing of PLCs by&amp;nbsp;this specific address (if other used).&lt;br /&gt;
We can introduce a Magelis terminal to the existing network. &lt;br /&gt;
In this example we will follow the specified address and we will see how to put together the basic commands for data exchange. &lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjZvFjRtANOOZg7CWzQVpTyXQabzvOpTEmgrvHIRjHRQPbIIRjZmOthMXDAGh61F60C3hmYictq_c6Ce_FXYv7D4ti4vLjRG371uPSvp7Z6pJcDYB-ktxR7YMbHHydmA9g13QQuJtHoVAYi/s1600/42.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjZvFjRtANOOZg7CWzQVpTyXQabzvOpTEmgrvHIRjHRQPbIIRjZmOthMXDAGh61F60C3hmYictq_c6Ce_FXYv7D4ti4vLjRG371uPSvp7Z6pJcDYB-ktxR7YMbHHydmA9g13QQuJtHoVAYi/s400/42.JPG&quot; height=&quot;283&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
Figure 3 &lt;/div&gt;
&lt;br /&gt;
The following figure (Fig.4) shows the commands necessary to achieve communication between the PLC network UNITEL-WAY&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhxgJZPP0HiUqeTTZwM1D94I3EJKdUUk22wst9_BI7EWn-D2hhtXnZbT2omPO5J77oFU8AhwfJ5iEQP8CZh2QcnVJ8Qcve0uaFNWdUd2L3ceRirp40K4BYRwM_EerTXE6tNFFopEmWwowyA/s1600/43.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhxgJZPP0HiUqeTTZwM1D94I3EJKdUUk22wst9_BI7EWn-D2hhtXnZbT2omPO5J77oFU8AhwfJ5iEQP8CZh2QcnVJ8Qcve0uaFNWdUd2L3ceRirp40K4BYRwM_EerTXE6tNFFopEmWwowyA/s400/43.JPG&quot; height=&quot;210&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
Figure 4&lt;/div&gt;
&lt;br /&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;Suppose you want to read three words from the Slave PLC using the command &lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;READ_VAR (ADR # 0.0.6, &#39;% MW&#39;, 1,3,% MW10: 3,% MW200: 4)&lt;/strong&gt;&lt;/span&gt; &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
ADR # 0.0.6: the destination address (Slave PLC), Module = 0, Channel = 0, Ad0 = 6 &lt;br /&gt;
&lt;br /&gt;
&#39;% MW&#39;: is the type of data (internal words) &lt;br /&gt;
&lt;br /&gt;
1:% MW1 is the Slave PLC 1st % MW &lt;br /&gt;
&lt;br /&gt;
3 is the total number of words to be read from the Slave PLC &lt;br /&gt;
&lt;br /&gt;
So you read the following 3 words - % MW1,% MW2,% MW3. &lt;br /&gt;
&lt;br /&gt;
%MW10: 3: is the area in the Master PLC to place the above three words &lt;br /&gt;
i.e positions % MW10,% MW11,% MW12, respectively. &lt;br /&gt;
&lt;br /&gt;
%MW200: 4: activity bit, report, length. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;Now suppose that we want to write three words to Slave PLC using the command &lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;WRITE_VAR (ADR # 0.0.6, &#39;% MW&#39;, 20,3,% MW30: 3,% MW250: 4) &lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
ADR # 0.0.6: the destination address (Slave PLC), Module = 0, Channel = 0, AD0 = 6 &lt;br /&gt;
&lt;br /&gt;
&#39;%MW&#39;: is the type of data (internal words) &lt;br /&gt;
&lt;br /&gt;
20 means the %MW20 the Slave PLC 20th % MW &lt;br /&gt;
&lt;br /&gt;
3 is the total number of words will be written to the Slave PLC &lt;br /&gt;
&lt;br /&gt;
So you write the following 3 words % MW20,% MW21,% MW22. &lt;br /&gt;
&lt;br /&gt;
% MW30: 3: is the area in the Master PLC from where they would write the above three words in the Slave PLC, ie positions% MW30,% MW31,% MW32, respectively. &lt;br /&gt;
&lt;br /&gt;
% MW250: 4: activity bit, report, length. &lt;br /&gt;
&lt;br /&gt;
MASTER - SLAVE &lt;br /&gt;
&lt;br /&gt;
READ &lt;br /&gt;
&lt;br /&gt;
% MW10: 3&amp;nbsp; &amp;lt;-- % MW1: 3 &lt;br /&gt;
&lt;br /&gt;
WRITE &lt;br /&gt;
&lt;br /&gt;
% MW30: 3 -- &amp;gt; % MW20: 3 &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg_0EgWQ2-KvHC3vJ0RPoPyoq2MqyfH8_rKtYTuu6ppS1r0xmt-hbvd4yCKNXaJFmHBuddvSSh15sgtrOgq3SlVxxyAZtGOFzi5VIRrVO27rkAMh_SgDRMuDLBpydZ0SLZJecXRB318TlRv/s1600/44.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg_0EgWQ2-KvHC3vJ0RPoPyoq2MqyfH8_rKtYTuu6ppS1r0xmt-hbvd4yCKNXaJFmHBuddvSSh15sgtrOgq3SlVxxyAZtGOFzi5VIRrVO27rkAMh_SgDRMuDLBpydZ0SLZJecXRB318TlRv/s400/44.JPG&quot; height=&quot;231&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
Figure 5&lt;/div&gt;
&lt;br /&gt;
In Figure 5 we see the internal view of TSXPACC01&lt;br /&gt;
&lt;br /&gt;
S1: Selector of how the PLC (Master or Slave) which is attached the TSXPACC01&lt;br /&gt;
S2: Selector finish line BUS.&lt;br /&gt;
JA and JB:&amp;nbsp;connectors TSXCSA 100/200/500 cable of the BUS.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEig9BIJB9ikLcHRrZlN_uvKK0YH9P-wzccmRRXFrRSkyenggv7QQPlysdMtJ-1lYhtUBIef_0G3zoVc-4VNDHLalFu4Hb7gRq5oMXXRqmigNni7l2aRK5ppiexE7BFSkTSCiPhskBNX7uID/s1600/45.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEig9BIJB9ikLcHRrZlN_uvKK0YH9P-wzccmRRXFrRSkyenggv7QQPlysdMtJ-1lYhtUBIef_0G3zoVc-4VNDHLalFu4Hb7gRq5oMXXRqmigNni7l2aRK5ppiexE7BFSkTSCiPhskBNX7uID/s400/45.JPG&quot; height=&quot;187&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
Figure 6&lt;/div&gt;
&lt;br /&gt;
Specific configuration options in our example.&lt;br /&gt;
For the Master PLC:&amp;nbsp;S1 place&amp;nbsp;in OFF postion&amp;nbsp;and S2 in the NOT OFF.&lt;br /&gt;
For the Slave PLC: S1 = NOT OFF, S2 = NOT OFF.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiQsAcPMg1TOOHUsYBvvQ-DnfZ1-9fp54j7qvVX1WvtA6YMjPY3-buuBCVxB3NW2ZtpIOftgz3S1QvG0qjTPkJabS_AB_FJT03PvZIxzLCnwzZ4H4axQn6-geSLRPfSgy44oal5Arrh4smu/s1600/46.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiQsAcPMg1TOOHUsYBvvQ-DnfZ1-9fp54j7qvVX1WvtA6YMjPY3-buuBCVxB3NW2ZtpIOftgz3S1QvG0qjTPkJabS_AB_FJT03PvZIxzLCnwzZ4H4axQn6-geSLRPfSgy44oal5Arrh4smu/s320/46.JPG&quot; ox=&quot;true&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
Figure 7&lt;/div&gt;
&lt;br /&gt;
In Figure 7 we see how to connect the cable&amp;nbsp;at the&amp;nbsp;interior connectors of&amp;nbsp;the&lt;br /&gt;
TSXPACC01, and at figure 8 the communication connectors of the TSX P ACC01&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgypDXgJ0br-yeBh8Yt_en-ByHCmiNnfIBAfjA-iP7d7J6OsE0XSo0uqX27DCjmb7ZRDRxVw5RiYC4Ogbhr5CmdVZJ39kO7qsA-l8RHGBsJjictVh-yU6DHDf5ftVj_ZlphxzbbPIGKtb-Q/s1600/47.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgypDXgJ0br-yeBh8Yt_en-ByHCmiNnfIBAfjA-iP7d7J6OsE0XSo0uqX27DCjmb7ZRDRxVw5RiYC4Ogbhr5CmdVZJ39kO7qsA-l8RHGBsJjictVh-yU6DHDf5ftVj_ZlphxzbbPIGKtb-Q/s320/47.JPG&quot; ox=&quot;true&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
Figure 8&lt;/div&gt;
&lt;div align=&quot;left&quot; class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
Summary:&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
This is an example of how to use the READ_VAR and WRITE_VAR commands and also how to configure the PLCs to form a UNITELWAY network. This code should be altered or inserted respectively in your specific application. It is your rensponsibility to use the example properly in your applications&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: left;&quot;&gt;
For more info visit Schneider Electric Site &lt;/div&gt;
&lt;div align=&quot;left&quot; class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div align=&quot;left&quot; class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/5761495221697964405'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/5761495221697964405'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/08/unitelway-network.html' title='UNITELWAY NETWORK'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEixTozYpBcpnLFmYTHUgRVIw_tRcsSZyDyTQzzDiZGXSEzFDBObpIwexSjzfYW2zHY1ryJVsp4PwdRyv841d7b1A1rbYwW61AqSFnWt7m96ZIq8ind7R3DVuRh8H5v7f00YcJoL_mkNq8gK/s72-c/40.JPG" height="72" width="72"/></entry><entry><id>tag:blogger.com,1999:blog-9131656014548957926.post-3438071899069976589</id><published>2010-08-19T21:01:00.000+03:00</published><updated>2015-01-03T00:23:47.963+02:00</updated><title type='text'>MICRO TSX37 USE OF INCREMENTAL ENCODER WITH INTEGRATED COUNTER AT CHANNEL 11.</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;MICRO TSX37 &lt;/strong&gt;&lt;/span&gt;&lt;/div&gt;
&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;USE OF INCREMENTAL ENCODER WITH INTEGRATED COUNTER AT CHANNEL 11.&lt;/strong&gt;&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
At following figure 1 is the connection of the P.L.C with TELEFAST 2 &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgMf8Sr0jdiozg1VN6TORH9JbHPVykTqTXRwGO-Vn7ZrOZs7SPjVvQalHPjQcwcCCuj9zqXehhfuWvewdA9VAp_HWvbrFJy-3HuKEfcjemAteKrr-oaPlRFTZqK9jSYbY7UWHdDSunDttRX/s1600/30.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgMf8Sr0jdiozg1VN6TORH9JbHPVykTqTXRwGO-Vn7ZrOZs7SPjVvQalHPjQcwcCCuj9zqXehhfuWvewdA9VAp_HWvbrFJy-3HuKEfcjemAteKrr-oaPlRFTZqK9jSYbY7UWHdDSunDttRX/s400/30.JPG&quot; height=&quot;242&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
Figure 1&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiifl0EECtLgxim8oWik8pb6jDpGYDHCVj-k32bhM76g_cYmFA4OtyNRRmM_dbH6SWzgJXrUMR7qZKvf_9fHPkyGoOsKxzcd1ZB25-BpXj4SxZns6Kha07ERbVkZ9AIPAhrl0pQWCtP_JCt/s1600/32.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiifl0EECtLgxim8oWik8pb6jDpGYDHCVj-k32bhM76g_cYmFA4OtyNRRmM_dbH6SWzgJXrUMR7qZKvf_9fHPkyGoOsKxzcd1ZB25-BpXj4SxZns6Kha07ERbVkZ9AIPAhrl0pQWCtP_JCt/s320/32.JPG&quot; height=&quot;145&quot; ox=&quot;true&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
Figure 2&lt;/div&gt;
&lt;br /&gt;
At our example we used P.L.C Micro TSX3722 and encoder XCC1510PR01K &lt;br /&gt;
with 11-30V/push-pull/100cpt &lt;br /&gt;
&lt;br /&gt;
In Fig. 2 connection with the sensors, which is similar with those of the ENCODER&lt;br /&gt;
Cables and color of encoder and TELEFAST 2&lt;br /&gt;
&lt;br /&gt;
RED = 24Vdc - 26 &lt;br /&gt;
BLACK = 0V - 27&lt;br /&gt;
GREEN = Α - 4&lt;br /&gt;
BROWN = Α - 1&lt;br /&gt;
YELLOW = Β - 8&lt;br /&gt;
ORANGE = Β - 10&lt;br /&gt;
And we connect the Α-, Β-, και 0V together. Ζ and Preset are Not Connected.&lt;br /&gt;
&lt;br /&gt;
The small program is analysed&lt;br /&gt;
The small code program named INCOUNTERUPDOWN.STX and you could download it &lt;a href=&quot;http://www.box.net/shared/0yjfeu5fvs&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: red;&quot;&gt;HERE&lt;/span&gt;&lt;/strong&gt;&lt;/a&gt;&lt;br /&gt;
We use two Setpoints (High &amp;amp; Low). When passed from High setpoint an output is activated %Q2.1. Then when the rotation of the movement will inversed, then passing through Low setpoint another output will be activated %Q2.0, and finally when under 15 steps ouputs are zeroing. &lt;br /&gt;
We used %MD0 for the Highsetpoint and %MD2 for Lowsetpoint which are give values at the following&lt;br /&gt;
&lt;br /&gt;
%MD0=%MD0.11.10 Value of High Setpoint &lt;br /&gt;
%MD2=%MD0.11.12 Value of Low Setpoint όπου&lt;br /&gt;
0 = Module&lt;br /&gt;
11 = Counter0&lt;br /&gt;
&lt;br /&gt;
Making Enable the Counter setting the %Q0.11 with a contact %Ι1.4&lt;br /&gt;
&lt;br /&gt;
Making Preset the Counter setting the %Q0.11.1 with a contact π.χ %Ι1.7&lt;br /&gt;
&lt;br /&gt;
Making Reset Preset τthe Counter setting the %Q0.11:X1&lt;br /&gt;
&lt;br /&gt;
With %I0.11.9 we know every momment the direction of movement of the Εncoder. &lt;br /&gt;
&lt;br /&gt;
%I0.11.7 (Current Value &amp;gt;Highsetpoint) Encoder Value has passed the Highsetpoint&lt;br /&gt;
&lt;br /&gt;
%I0.11.8 (Current Value&amp;gt;Lowsetpoint). Encoder Value has passed the Lowsetpoint&lt;br /&gt;
&lt;br /&gt;
Finally with WRITE_PARAM %CH0.11 we could change the High and Low setpoints giving values at %MD0 &amp;amp; %MD2.&lt;br /&gt;
&lt;br /&gt;
In the following figure 3 is the Hardware Configuration of the PLC Internal Counter.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhH4_HJ0VT-LzgiFeoNYJqaV_yCnaIjeVKtqoukxgV4_BoOJe-XG1dlLaQYVEUL-c9StawkJbPAZqgUDxL2fO_CJo_v8FnUnqAIkckXVCmiv5nCSWvoIiBLXaurf6x0chBgXiqecUOSAIZ6/s1600/31.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhH4_HJ0VT-LzgiFeoNYJqaV_yCnaIjeVKtqoukxgV4_BoOJe-XG1dlLaQYVEUL-c9StawkJbPAZqgUDxL2fO_CJo_v8FnUnqAIkckXVCmiv5nCSWvoIiBLXaurf6x0chBgXiqecUOSAIZ6/s400/31.JPG&quot; height=&quot;258&quot; ox=&quot;true&quot; width=&quot;400&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
Figure 3&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
Use of the Incremental encoder is only applied at Counter0 (CNT1 – CHANNEL 11) &lt;br /&gt;
&lt;br /&gt;
For more info visit the site &lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;sch&lt;/strong&gt;&lt;/span&gt;&lt;a href=&quot;http://www.schneider-electric.com/sites/corporate/en/products-services/automation-control/automation-control.page&quot;&gt;&lt;span style=&quot;color: red;&quot;&gt;&lt;strong&gt;neider-electric&lt;/strong&gt;&lt;/span&gt;&lt;/a&gt; at the category&lt;br /&gt;
P.L.C Micro . Hardware Installation Counting.&lt;/div&gt;
</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3438071899069976589'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/9131656014548957926/posts/default/3438071899069976589'/><link rel='alternate' type='text/html' href='http://plc-scada-programming.blogspot.com/2010/08/micro-tsx37-use-of-incremental-encoder.html' title='MICRO TSX37 USE OF INCREMENTAL ENCODER WITH INTEGRATED COUNTER AT CHANNEL 11.'/><author><name>jupiter</name><uri>http://www.blogger.com/profile/04656165336824838326</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgMf8Sr0jdiozg1VN6TORH9JbHPVykTqTXRwGO-Vn7ZrOZs7SPjVvQalHPjQcwcCCuj9zqXehhfuWvewdA9VAp_HWvbrFJy-3HuKEfcjemAteKrr-oaPlRFTZqK9jSYbY7UWHdDSunDttRX/s72-c/30.JPG" height="72" width="72"/></entry></feed>