<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:blogger='http://schemas.google.com/blogger/2008' xmlns:georss='http://www.georss.org/georss' xmlns:gd="http://schemas.google.com/g/2005" xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-832859679035038230</id><updated>2026-10-07T01:27:52.285-07:00</updated><category term="REFRIGERATION TOOLS AND EQUIPMENT"/><category term="Marine Refrigerated Container (Reefer) Training Module Year 2017"/><category term="Dhilreefer multilanguage"/><category term="starcool video"/><category term="Dhilreefer Worldwide translations"/><category term="danfoss animation"/><category term="Carrier Reefer Manual"/><category term="Reefer Container Special Custom Tools"/><category term="HVAC Animations"/><category term="Brazing"/><category term="Container logistics and supply chain terminology"/><category term="understanding relative humidity and dew point (link)"/><category term="Electric And Electronic"/><category term="Thermo King Reefer Manuals"/><category term="Kenali Mereka"/><category term="Daikin Reefer Manual"/><category term="HVAC Clinic"/><category term="Draft - Code of Practice for handling fresh fruit and vegetables in refrigerated shipping containers"/><category term="Pendidikan Penyaman Udara"/><category term="technology animation"/><category term="Dhilandroid"/><category term="Reefer Cargo Damage &amp; Claims"/><category term="Temperature And Control"/><category term="Dhil IT Techno"/><category term="Cold Truck &amp; Trailer"/><category term="Mitsubishi Reefer Manual"/><category term="Polymath Animations"/><category term="Container Structure Guide/ Reefer &#39;GP"/><category term="IICL Books .apk"/><category term="Gas And Pressure"/><category term="Computer &amp; Device Repair"/><category term="The Container Arts Of Architectures"/><category term="Reefer Commodity Control"/><category term="assembling a refrigeration system"/><category term="Gas Testing"/><category term="HVAC Books"/><category term="Handling Of Reefer Container"/><category term="Shipping Container House"/><category term="Sketch And Design"/><category term="StarCool Reefer Manuals"/><category term="Windows Run Commands"/><category term="DhilReefer Google Search Engine"/><category term="Electricity Animations"/><category term="Reefer Journal"/><category term="Reefer Software"/><category term="Container Depot Knowledge And Info"/><category term="DhilReefer: Comprehensive Theory And Practical Marine Refrigerated Container Study (Reefer Module)"/><category term="Dhilreefer Listing"/><category term="Electricity Motor Knowledge And Info"/><category term="Expansion Valves"/><category term="Gate In-Out Surveyor Reference"/><category term="Reefer Container Power Plug"/><category term="Refrigeration And HVAC Knowledge"/><category term="Container equipment data exchange (CEDEX)"/><category term="Controller"/><category term="Denso Reefer Manual"/><category term="Refrigerated Container Inspection"/><category term="Tools"/><category term="Ventilation"/><category term="greating"/><category term="2017 New Year Post"/><category term="Auto Setting And Adjustment"/><category term="Blogger profile"/><category term="Carrier TechLine ~ P6-5"/><category term="Carrier TechLine ~ Telematic"/><category term="Code select 571-1XX - 3XX"/><category term="Compressor"/><category term="Container ISO Codes"/><category term="Container and logistics terminology"/><category term="Cooling Tower"/><category term="Dehumidification"/><category term="Device &amp; Configuration"/><category term="Dhilreefer Video"/><category term="ENGLISH FOR TECHNICAL PURPOSES"/><category term="Gauge"/><category term="History Of"/><category term="Interrogator"/><category term="Logistics Glosarry"/><category term="MP4000 transformer"/><category term="Mariner - SeaPort"/><category term="Reefer Container Body Structure"/><category term="Reefer Container Business"/><category term="Reefer Container Knowledge And Info"/><category term="Reefer PTI - Pre Trip Inspection"/><category term="Reefer Un-plug Music"/><category term="Reefer Wiring"/><category term="Refrigeration tools"/><category term="Related Reefer Container Setting Temperature With Commodities"/><category term="S.O.P"/><category term="SMTP Server List"/><category term="Shipping Container Info"/><category term="Shipping Container Inspection"/><category term="Sistem Komputer"/><category term="Superheat"/><category term="Technical Committee"/><category term="Troubleshooting"/><category term="Visual survey"/><category term="happy ied 2017"/><title type='text'>Reefer container</title><subtitle type='html'>Reefer container GP knowledge base for all parties in the world</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://dhilreefer.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default?max-results=4&amp;redirect=false'/><link rel='alternate' type='text/html' href='http://dhilreefer.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><link rel='next' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default?start-index=5&amp;max-results=4&amp;redirect=false'/><author><name>Dhil Engineering @ DhilReefer</name><uri>http://www.blogger.com/profile/16600514842610410534</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='32' src='//blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiXKWebQg0ijXWQAIs5-cn7t0g42LjFW60zpZviOqAvgn56JMh5jY3IMvApCjF9cu50uEWH7d2XVWUNUGsiTFCX7M0cANjhqWmFme7UG5EWXit0J5WXwZfk1fbln7Hug/s113/AKedOLRCvEz7g7552hptGtJLrlf-QZvzauLUXzL_5n3z%3Ds900-c-k-c0x00ffffff-no-rj'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>908</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>4</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-832859679035038230.post-8944290706959483406</id><published>2025-11-16T07:30:15.171-08:00</published><updated>2025-11-16T07:30:17.575-08:00</updated><title type='text'>Cd18 Software Revision Number</title><content type='html'>Cd18 displays the software revision number</content><link rel='replies' type='application/atom+xml' href='http://dhilreefer.blogspot.com/feeds/8944290706959483406/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/832859679035038230/8944290706959483406' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/8944290706959483406'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/8944290706959483406'/><link rel='alternate' type='text/html' href='http://dhilreefer.blogspot.com/2025/11/cd18-software-revision-number.html' title='Cd18 Software Revision Number'/><author><name>Dhil Engineering @ DhilReefer</name><uri>http://www.blogger.com/profile/16600514842610410534</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='32' src='//blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiXKWebQg0ijXWQAIs5-cn7t0g42LjFW60zpZviOqAvgn56JMh5jY3IMvApCjF9cu50uEWH7d2XVWUNUGsiTFCX7M0cANjhqWmFme7UG5EWXit0J5WXwZfk1fbln7Hug/s113/AKedOLRCvEz7g7552hptGtJLrlf-QZvzauLUXzL_5n3z%3Ds900-c-k-c0x00ffffff-no-rj'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-832859679035038230.post-413486431194759363</id><published>2025-11-16T07:29:32.839-08:00</published><updated>2025-11-16T07:29:35.309-08:00</updated><title type='text'>Cd17 Relative Humidity (%)</title><content type='html'>Cd17 displays the humidity sensor (HS) reading, as a percent value.</content><link rel='replies' type='application/atom+xml' href='http://dhilreefer.blogspot.com/feeds/413486431194759363/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/832859679035038230/413486431194759363' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/413486431194759363'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/413486431194759363'/><link rel='alternate' type='text/html' href='http://dhilreefer.blogspot.com/2025/11/cd17-relative-humidity.html' title='Cd17 Relative Humidity (%)'/><author><name>Dhil Engineering @ DhilReefer</name><uri>http://www.blogger.com/profile/16600514842610410534</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='32' src='//blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiXKWebQg0ijXWQAIs5-cn7t0g42LjFW60zpZviOqAvgn56JMh5jY3IMvApCjF9cu50uEWH7d2XVWUNUGsiTFCX7M0cANjhqWmFme7UG5EWXit0J5WXwZfk1fbln7Hug/s113/AKedOLRCvEz7g7552hptGtJLrlf-QZvzauLUXzL_5n3z%3Ds900-c-k-c0x00ffffff-no-rj'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-832859679035038230.post-6034629693490654651</id><published>2025-11-16T07:28:59.472-08:00</published><updated>2025-11-16T07:29:02.103-08:00</updated><title type='text'>Cd16 Compressor Motor / Unit Run Time Hour Meter</title><content type='html'>Unit Run Time Hour Meter&lt;div&gt;&lt;br&gt;&lt;/div&gt;&lt;div&gt;Cd16 displays the compressor motor hours. Press the ENTER key while in Cd16 to view unit run time. Total hours are recorded in increments of 10 hours (i.e., 3000 hours is displayed as 300).&lt;/div&gt;&lt;div&gt;&lt;br&gt;&lt;/div&gt;&lt;div&gt;Press and hold the ENTER key for 5 seconds to reset the Compressor Motor Hour Meter display. The Unit Run Time Hour Meter cannot be reset.&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://dhilreefer.blogspot.com/feeds/6034629693490654651/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/832859679035038230/6034629693490654651' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/6034629693490654651'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/6034629693490654651'/><link rel='alternate' type='text/html' href='http://dhilreefer.blogspot.com/2025/11/cd16-compressor-motor-unit-run-time.html' title='Cd16 Compressor Motor / Unit Run Time Hour Meter'/><author><name>Dhil Engineering @ DhilReefer</name><uri>http://www.blogger.com/profile/16600514842610410534</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='32' src='//blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiXKWebQg0ijXWQAIs5-cn7t0g42LjFW60zpZviOqAvgn56JMh5jY3IMvApCjF9cu50uEWH7d2XVWUNUGsiTFCX7M0cANjhqWmFme7UG5EWXit0J5WXwZfk1fbln7Hug/s113/AKedOLRCvEz7g7552hptGtJLrlf-QZvzauLUXzL_5n3z%3Ds900-c-k-c0x00ffffff-no-rj'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-832859679035038230.post-3033739756732949406</id><published>2025-11-16T06:52:26.598-08:00</published><updated>2025-11-16T06:52:29.037-08:00</updated><title type='text'>Cd15 Digital Unloader Valve / Digital Loader Valve</title><content type='html'>Cd15 displays the status of the digital unloader valve (DUV) as Open or Closed.&lt;div&gt;&lt;br&gt;&lt;/div&gt;&lt;div&gt;For PrimeLINE EDGE units (571-3xx models) the status of the digital loader valve (DLV) can also be displayed. To display the DLV status, press and hold the ENTER key for 3 seconds and continue to hold. When the key is released, the display switches back to the DUV.&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://dhilreefer.blogspot.com/feeds/3033739756732949406/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment/fullpage/post/832859679035038230/3033739756732949406' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/3033739756732949406'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/832859679035038230/posts/default/3033739756732949406'/><link rel='alternate' type='text/html' href='http://dhilreefer.blogspot.com/2025/11/cd15-digital-unloader-valve-digital.html' title='Cd15 Digital Unloader Valve / Digital Loader Valve'/><author><name>Dhil Engineering @ DhilReefer</name><uri>http://www.blogger.com/profile/16600514842610410534</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='32' height='32' src='//blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgiXKWebQg0ijXWQAIs5-cn7t0g42LjFW60zpZviOqAvgn56JMh5jY3IMvApCjF9cu50uEWH7d2XVWUNUGsiTFCX7M0cANjhqWmFme7UG5EWXit0J5WXwZfk1fbln7Hug/s113/AKedOLRCvEz7g7552hptGtJLrlf-QZvzauLUXzL_5n3z%3Ds900-c-k-c0x00ffffff-no-rj'/></author><thr:total>0</thr:total></entry></feed>