<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" media="screen" href="/~d/styles/rss2full.xsl"?><?xml-stylesheet type="text/css" media="screen" href="http://feeds.feedburner.com/~d/styles/itemcontent.css"?><rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:wfw="http://wellformedweb.org/CommentAPI/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:sy="http://purl.org/rss/1.0/modules/syndication/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/" version="2.0"><channel><title>Senti-Solutions.com</title> <link>http://www.senti-solutions.com</link> <description>Best pressure sensors in the world!</description> <lastBuildDate>Mon, 21 Mar 2011 09:05:54 +0000</lastBuildDate> <language>en</language> <sy:updatePeriod>hourly</sy:updatePeriod> <sy:updateFrequency>1</sy:updateFrequency> <atom10:link xmlns:atom10="http://www.w3.org/2005/Atom" rel="self" type="application/rss+xml" href="http://feeds.feedburner.com/Senti-solutionscom" /><feedburner:info xmlns:feedburner="http://rssnamespace.org/feedburner/ext/1.0" uri="senti-solutionscom" /><atom10:link xmlns:atom10="http://www.w3.org/2005/Atom" rel="hub" href="http://pubsubhubbub.appspot.com/" /><item><title>differential pressure</title><link>http://www.senti-solutions.com/116/differential-pressure/</link> <comments>http://www.senti-solutions.com/116/differential-pressure/#comments</comments> <pubDate>Fri, 04 Sep 2009 12:22:32 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[pressure sensor]]></category> <category><![CDATA[differential pressure]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=116</guid> <description><![CDATA[Pressure transmitter for the metering of differential pressure How do our differential pressure sensing element function? Study this in our summarization! The differential pressure in non-aggressive gasses and atmospheres can be grasp with the pressure sensor for the metering of differential pressure. The used metering item is a pressure detector produced into Si technology. The [...]
Related posts:<ol><li><a href='http://www.senti-solutions.com/108/absolute-pressure/' rel='bookmark' title='absolute pressure'>absolute pressure</a></li><li><a href='http://www.senti-solutions.com/114/relative-pressure/' rel='bookmark' title='relative pressure'>relative pressure</a></li></ol>]]></description> <content:encoded><![CDATA[<h2>Pressure transmitter for the metering of differential pressure</h2><div class="wp-caption alignright" style="width: 280px"><img class=" " title="differential pressure" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/ALDPS-LCD.png" alt="ALDPS LCD differential pressure" width="270" height="270" /><p class="wp-caption-text">differential pressure sensor with lcd</p></div><h3>How do our differential pressure sensing element function? Study this in our summarization!</h3><p>The differential pressure in non-aggressive gasses and atmospheres can be grasp with the pressure sensor for the metering of differential pressure. The used metering item is a pressure detector produced into Si technology. The pressure sensor use a wheatstone resistance bridge for the capturing of the pressure alteration which was diffused into the silicon crystal. The measurement signal gets temperature and pressure compensated by means of IC. Each pressure transducer will be calibrated during the assembling method. Through this a high reliability and correctness of the pressure sensor is guaranteed.</p><p>Dissimilar signals are ready for use as an output signal depending on application example. Besides the norm signals of 0 &#8230;. 10 V or 4 &#8230;. 20 mA the pressure transducers for differential pressure can also be delivered with a gSPI interface. It is also possible to deliver the differential pressure pressure sensors with mixed output signals so that the output signal can be chosen at the location of use by means of jumper.</p><p>The gSPI interface is a bus system. Up to 120 pressure transmitters can be achieved at this. The coupling of pressure detectors for differential pressure without gSPI interface is carried out by bus connection modules to the gSPI bus.</p><p>The pressure-metering transmitters are obstructed in a synthetic housing in IP65. The pressure-gauging sensor can alternatively be assembled with a 4-digit LCD for the indication of the measurement. The unity is also shown on the display as well as the measurement.</p><p>The pressure-metering transmitter can instead be distributed for differential pressure also in a extreme-grade steel execution. The differential pressure can be measured in liquids and aggressive conditions with that. At this version the gauging item consists of a pressure sensor established in thin film technology on a extreme-grade steel membrane. It is therefore guaranteed that all medium touching parts consist of exorbitant-grade steel completely. A wheatstone resistance bridge circuit is used for the detection also at this pressure sensor. By use of a semiconductor chip the measurement signal of the wheatstone bridge gets temperature and pressure compensated. Previous to delivery this pressure transducer is also calibrated to be able to attest a extreme precision and accuracy.</p><p>This pressure-measuring transducer can be delivered with the output signals 0 &#8230;. 10 V, 4 &#8230;. 20 mA or 0 &#8230;. 20 mA.</p><p>The use of these pressure sensors for differential pressure is carried out in the clean room, medication and filtering technique in ventilating systems and climate channels into paint spraying cabins or into canteen kitchens.</p><div class="wp-caption alignright" style="width: 280px"><img class=" " title="differential pressure" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/CALDPT-LCD.png" alt="CALDPT LCD differential pressure" width="270" height="253" /><p class="wp-caption-text">differential pressure sensor with lcd</p></div><p>Each differential pressure pressure sensor can be distributed on call with a calibrating certificate also with DKD-calibrating testification.</p><p><strong><span id="more-116"></span></strong></p><div class="wp-caption alignright" style="width: 280px"><img class=" " title="differential pressure" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/DDPTM-2.png" alt="DDPTM 2 differential pressure" width="270" height="227" /><p class="wp-caption-text">differential pressure sensor with lcd in high-grade steel</p></div><p><strong>Hints</strong></p><p>You may link to this page!</p><p>The pressure transducer is maintenance-free.</p><p>This page was arranged with care. It, even so, was not possible to take into account all conceivable function circumstances. If you should miss notes for your particular formulation, use the contact form for your questions.</p><p><strong>Indications for safety causes</strong></p><p>Notice the corresponding national safety regulations (e.g. DIN VDE 0100 part 410) absolutely for assembly, putting into operation and operation of these pressure sensors.</p><p><em>Mistakes and changes in the sense of technical improvements reserved.</em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>Related posts:<ol><li><a href='http://www.senti-solutions.com/108/absolute-pressure/' rel='bookmark' title='absolute pressure'>absolute pressure</a></li><li><a href='http://www.senti-solutions.com/114/relative-pressure/' rel='bookmark' title='relative pressure'>relative pressure</a></li></ol></p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/116/differential-pressure/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>relative pressure</title><link>http://www.senti-solutions.com/114/relative-pressure/</link> <comments>http://www.senti-solutions.com/114/relative-pressure/#comments</comments> <pubDate>Fri, 04 Sep 2009 10:48:59 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[pressure sensor]]></category> <category><![CDATA[relative pressure]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=114</guid> <description><![CDATA[Pressure transmitter for the gauging of relative pressure How do our relative pressure transmitter operate? Read this in our summarization! The relative pressure-measuring sensor can be distributed for relative pressure  in a high-grade steel execution. The relative pressure can be measured in liquids and aggressive media with that. At this construction the measuring element consists [...]
Related posts:<ol><li><a href='http://www.senti-solutions.com/108/absolute-pressure/' rel='bookmark' title='absolute pressure'>absolute pressure</a></li><li><a href='http://www.senti-solutions.com/116/differential-pressure/' rel='bookmark' title='differential pressure'>differential pressure</a></li></ol>]]></description> <content:encoded><![CDATA[<h2>Pressure transmitter for the gauging of relative pressure</h2><div class="wp-caption alignright" style="width: 280px"><img class=" " title="relative pressure" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/BAPT-LCD.png" alt="BAPT LCD relative pressure" width="270" height="270" /><p class="wp-caption-text">relative pressure sensor with lcd</p></div><h3>How do our relative pressure transmitter operate? Read this in our summarization!</h3><p>The relative pressure-measuring sensor can be distributed for relative pressure  in a high-grade steel execution. The relative pressure can be measured in liquids and aggressive media with that. At this construction the measuring element consists of a pressure sensor established in thin film technology on a exorbitant-grade iron steel membrane. It is in consequence warranted that all medium touching parts consist of high-grade iron steel completely. A wheatstone resistance bridge is used for the measuring at this pressure detector. By use of a semiconductor chip the measurement signal of the wheatstone bridge gets temperature and pressure compensated. Previous to shipment this pressure transmitter is calibrated to be able to warrantee a high correctness and reliability.</p><p>This pressure-measuring transmitter can be distributed with the output signals 0 &#8230;. 10 V, 4 &#8230;. 20 mA or 0 &#8230;. 20 mA.</p><p>The use of these pressure sensors for relative pressure is carried out in pneumatics, process measuring technique and in the building technology. The pressure transmitter could also be delivered with an EEx-approval.</p><p>Each relative pressure pressure transmitter can be delivered on inquiry with calibrating testification also with DKD-calibrating testification.</p><p><span id="more-114"></span></p><div class="wp-caption alignright" style="width: 96px"><img class=" " title="relative pressure" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/RSPT.png" alt="RSPT relative pressure" width="86" height="270" /><p class="wp-caption-text">relative pressure sensor in high-grade steel</p></div><p><strong>Advices</strong></p><p>You may link to this page!</p><p>The pressure transmitter is maintenance-free.</p><p>This site was arranged with attention. It, however, was not possible to take into answer for all imaginable application circumstances. If you should consider to miss hints for your special formulation, use the contact form for your doubts.</p><p><strong>Notes for safety arguments</strong></p><p>Observe the corresponding national safety regulations (e.g. DIN VDE 0100 part 410) relatively for assembly, putting into operation and operation of these pressure sensors.</p><p><em>Mistakes and changes in the sense of technical improvementsreserved.</em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>Related posts:<ol><li><a href='http://www.senti-solutions.com/108/absolute-pressure/' rel='bookmark' title='absolute pressure'>absolute pressure</a></li><li><a href='http://www.senti-solutions.com/116/differential-pressure/' rel='bookmark' title='differential pressure'>differential pressure</a></li></ol></p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/114/relative-pressure/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>absolute pressure</title><link>http://www.senti-solutions.com/108/absolute-pressure/</link> <comments>http://www.senti-solutions.com/108/absolute-pressure/#comments</comments> <pubDate>Fri, 04 Sep 2009 09:26:49 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[pressure sensor]]></category> <category><![CDATA[absolut pressure]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=108</guid> <description><![CDATA[Pressure sensor for the measuring of absolute pressure How do our absolute pressure sensor work? Read this in our description! The barometric pressure in non-aggressive gasses and atmospheres can be grasped with the pressure sensor for the measuring of absolute pressure. The used measuring element is a pressure sensor produced into silicon technology. The pressure [...]
Related posts:<ol><li><a href='http://www.senti-solutions.com/114/relative-pressure/' rel='bookmark' title='relative pressure'>relative pressure</a></li><li><a href='http://www.senti-solutions.com/116/differential-pressure/' rel='bookmark' title='differential pressure'>differential pressure</a></li></ol>]]></description> <content:encoded><![CDATA[<h2>Pressure sensor for the measuring of absolute pressure</h2><div class="wp-caption alignright" style="width: 280px"><img class=" " title="absolute pressure" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/BAPT-LCD.png" alt="BAPT LCD absolute pressure" width="270" height="270" /><p class="wp-caption-text">absolute pressure sensor with lcd</p></div><h3>How do our absolute pressure sensor work? Read this in our description!</h3><p>The barometric pressure in non-aggressive gasses and atmospheres can be grasped with the pressure sensor for the measuring of absolute pressure. The used measuring element is a pressure sensor produced into silicon technology. The pressure sensor use a wheatstone resistance bridge for the recording of the pressure change which was diffused into the silicon crystal. The measurement signal gets temperature and pressure compensated by means of microprocessor. Every pressure transmitter will be calibrated during the manufacturing process. Through this a high reliability and precision of the pressure sensor is guaranteed.</p><p>Different signals are available as an output signal depending on application case. Besides the norm signals of 0 &#8230;. 10 V or 4 &#8230;. 20 mA the pressure transmitters for absolute pressure can also be delivered with a gSPI interface. It is also possible to deliver the absolute pressure pressure sensors with composite output signals so that the output signal can be chosen at the site of usage by means of jumper.</p><p>The gSPI interface is a bus system. Up to 120 pressure transmitters can be operated at this. The connection of pressure sensors for absolute pressure without gSPI interface is carried out via bus coupler modules to the gSPI bus.</p><p>The pressure-measuring transducers are obstructed in a plastic housing in IP65. The pressure-measuring transmitter can optionally be equipped with a 4-digit LCD for the indication of the measurement. The unity is also displayed on the display besides the measurement.</p><p>The pressure-measuring transducer can alternatively be delivered for absolute pressure also in a high-grade steel execution. The absolute pressure can be detected in liquids and aggressive media with that. At this execution the measuring element consists of a pressure sensor found in thin film technology on a high-grade steel membrane. It is therefore guaranteed that all medium touching parts consist of high-grade steel completely. A wheatstone resistance bridge is used for the detection also at this pressure sensor. By use of a microprocessor the measurement signal of the wheatstone bridge gets temperature and pressure compensated. Before delivery this pressure transmitter is also calibrated to be able to guarantee a high precision and reliability.</p><p>This pressure-measuring transducer can be delivered with the output signals 0 &#8230;. 10 V, 4 &#8230;. 20 mA or 0 &#8230;. 20 mA.</p><p>The use of these pressure transmitters for absolute pressure is carried out in the clean room, medicine and filtering technique in ventilation and climate channels into paint spraying cabins or into canteen kitchens.</p><p>Every absolute pressure pressure transducer can be delivered on request with calibrating certificate also with DKD-calibrating certificate.</p><p><strong><span id="more-108"></span></strong></p><div class="wp-caption alignright" style="width: 96px"><img class=" " title="absolute pressure" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/RSPT.png" alt="RSPT absolute pressure" width="86" height="270" /><p class="wp-caption-text">absolute pressure sensor in high-grade steel</p></div><p><strong>Hints</strong></p><p>You may link to this page!</p><p>The pressure transmitter is maintenance-free.</p><p>This page was arranged with care. It, however, was not possible to take into account all conceivable application cases. If you should miss notes for your special formulation, use the contact form for your questions.</p><p><strong>Indications for safety reasons</strong></p><p>Observe the corresponding national safety regulations (e.g. DIN VDE 0100 part 410) absolutely for assembly, putting into operation and operation of these pressure sensors.</p><p><em>Mistakes and changes in the sense of technical improvements reserved.<br /> </em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>Related posts:<ol><li><a href='http://www.senti-solutions.com/114/relative-pressure/' rel='bookmark' title='relative pressure'>relative pressure</a></li><li><a href='http://www.senti-solutions.com/116/differential-pressure/' rel='bookmark' title='differential pressure'>differential pressure</a></li></ol></p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/108/absolute-pressure/feed/</wfw:commentRss> <slash:comments>1</slash:comments> </item> <item><title>pressure switch</title><link>http://www.senti-solutions.com/103/pressure-switch/</link> <comments>http://www.senti-solutions.com/103/pressure-switch/#comments</comments> <pubDate>Fri, 04 Sep 2009 09:11:21 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[pressure switch]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=103</guid> <description><![CDATA[Pressure switch for the metering of pressure How do our pressure switch function? Study this in our summarization! The pressure in non-aggressive gasses and atmospheres can be grasp with the pressure switch for the metering of pressure. The used metering item is a pressure detector produced into Si technology. The pressure sensor use a wheatstone [...]
No related posts.]]></description> <content:encoded><![CDATA[<h2>Pressure switch for the metering of pressure</h2><div class="wp-caption alignright" style="width: 280px"><img class=" " title="pressure switch" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/ALDPS2-LCD.png" alt="ALDPS2 LCD pressure switch" width="270" height="200" /><p class="wp-caption-text">pressure switch with lcd</p></div><h3>How do our pressure switch function? Study this in our summarization!</h3><p>The pressure in non-aggressive gasses and atmospheres can be grasp with the pressure switch for the metering of pressure. The used metering item is a pressure detector produced into Si technology. The pressure sensor use a wheatstone resistance bridge for the capturing of the pressure alteration which was diffused into the silicon crystal. The measurement signal gets temperature and pressure compensated by means of IC. Each pressure switch will be calibrated during the assembling method. Through this a high reliability and correctness of the pressure sensor is guaranteed.</p><p>Dissimilar signals are ready for use as an output signal depending on application example. Besides the norm signals of 0 &#8230;. 10 V or 4 &#8230;. 20 mA the pressure switch can also be delivered with a gSPI interface. It is also possible to deliver the pressure switch with mixed output signals so that the output signal can be chosen at the location of use by means of jumper.</p><p>The gSPI interface is a bus system. Up to 120 pressure transmitters and pressure switches can be achieved at this. The coupling of pressure switches without gSPI interface is carried out by bus connection modules to the gSPI bus.</p><p>The pressure-metering switch are obstructed in a synthetic housing in IP65. The pressure-gauging switch can alternatively be assembled with a 4-digit LCD for the indication of the measurement. The unity is also shown on the display as well as the measurement.</p><p>The pressure-metering transmitter can instead be distributed for pressure also in a extreme-grade steel execution. The pressure can be measured in liquids and aggressive conditions with that. At this version the gauging item consists of a pressure sensor established in thin film technology on a extreme-grade steel membrane. It is therefore guaranteed that all medium touching parts consist of exorbitant-grade steel completely. A wheatstone resistance bridge circuit is used for the detection also at this pressure sensor. By use of a semiconductor chip the measurement signal of the wheatstone bridge gets temperature and pressure compensated. Previous to delivery this pressure switch is also calibrated to be able to attest a extreme precision and accuracy.</p><p>This pressure-measuring switch can be delivered with the output signals 0 &#8230;. 10 V, 4 &#8230;. 20 mA or 0 &#8230;. 20 mA.</p><p>The use of these pressure switches is carried out in the clean room, medication and filtering technique in ventilating systems and climate channels into paint spraying cabins or into canteen kitchens.</p><p>Each pressure switch can be distributed on call with a calibrating certificate also with DKD-calibrating testification.</p><p><strong><span id="more-103"></span></strong></p><div class="wp-caption alignright" style="width: 280px"><img class=" " title="pressure switch" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/DDPTM-2.png" alt="DDPTM 2 pressure switch" width="270" height="227" /><p class="wp-caption-text">pressure switch with lcd in high-grade steel</p></div><p><strong>Hints</strong></p><p>You may link to this page!</p><p>The pressure switch is maintenance-free.</p><p>This page was arranged with care. It, even so, was not possible to take into account all conceivable function circumstances. If you should miss notes for your particular formulation, use the contact form for your questions.</p><p><strong>Indications for safety causes</strong></p><p>Notice the corresponding national safety regulations (e.g. DIN VDE 0100 part 410) absolutely for assembly, putting into operation and operation of these pressure switches.</p><p><em>Mistakes and changes in the sense of technical improvements reserved.</em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>No related posts.</p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/103/pressure-switch/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>Druckschalter</title><link>http://www.senti-solutions.com/48/druckschalter/</link> <comments>http://www.senti-solutions.com/48/druckschalter/#comments</comments> <pubDate>Mon, 31 Aug 2009 08:52:23 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[Druckschalter]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=48</guid> <description><![CDATA[Druckschalter zum Erfassen von Druck Wie arbeiten unsere Druckschalter? Erfahren Sie dies in unserer Zusammenfassung! Der Druck in nicht-aggressiven Gasen und Atmosphären kann mit dem Druckschalter erfasst werden. Als Druckaufnehmer wird ein Drucksensor verwendet. Dieser Drucksensor ist in Siliziumtechnologie hergestellt. Zur Detektion der Druckänderung wird eine Wheatstone-Widerstandsbrücke genutzt. Diese ist in die Siliziummembran des Drucksensors [...]
No related posts.]]></description> <content:encoded><![CDATA[<h2>Druckschalter zum Erfassen von Druck</h2><div class="wp-caption alignright" style="width: 280px"><img class=" " title="Druckschalter" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/ALDPS2-LCD.png" alt="ALDPS2 LCD Druckschalter" width="270" height="200" /><p class="wp-caption-text">Druckschalter mit LCD</p></div><h3>Wie arbeiten unsere Druckschalter? Erfahren Sie dies in unserer Zusammenfassung!</h3><p>Der Druck in nicht-aggressiven Gasen und Atmosphären kann mit dem Druckschalter erfasst werden. Als Druckaufnehmer wird ein Drucksensor verwendet. Dieser Drucksensor ist in Siliziumtechnologie hergestellt. Zur Detektion der Druckänderung wird eine Wheatstone-Widerstandsbrücke genutzt. Diese ist in die Siliziummembran des Drucksensors eindiffundiert. Mit einem Mikroprozessor wird das Messsignal Druck- und Temperatur kompensiert. Während der Herstellung wird jeder Druckschalter kalibriert. Mit diesen Maßnahmen kann eine hohe Genauigkeit und Zuverlässigkeit garantiert werden.</p><p>Verschiedene Signale stehen als Ausgangssignale in Abhängigkeit der Anwendung zur Verfügung. Neben den Signalen von 0 &#8230;. 10 V oder 4 &#8230;. 20 mA kann der Druckschalter auch mit einem gSPI Interface geliefert werden. Ebenfalls ist es möglich, den Druckschalter mit mehreren Ausgangssignalen zu liefern. Der Anwender hat dann am Einsatzort die Möglichkeit, dass Ausgangssignal mittels Jumper zu wählen.</p><p>Das gSPI Interface ist ein Bus System. Bis zu 120 Drucktransmitter und Druckschalter können daran angeschlossen werden. Druckschalter ohne gSPI Interface können mittels Buskoppler-Modulen an den gSPI Bus angeschlossen werden.</p><p>Die Druckschalter werden in einem Kunststoffgehäuse mit IP65 geliefert. Auf Wunsch kann der Druckschalter mit einem 4-Digit LCD als Anzeige für Messwerte ausgestattet werden.  Neben den Messwerten können auf dem Display auch die Einheiten angezeigt werden.</p><p>Der Druckschalter kann ebenfalls in einer Edelstahlausführung geliefert werden. Damit kann der Druck in Flüssigkeiten und aggressiven Umgebungen erfasst werden. Als Messelement wird bei dieser Ausführung ein Drucksensor verwendet, welcher aus einer Edelstahl-Membran mit in Dünnschicht-Technologie aufgebrachter Siliziumschicht besteht. Aus diesem Grund ist sichergestellt, dass alle medienberührenden Teile komplett aus Edelstahl bestehen. In die Siliziumschicht ist eine Wheatstone-Widerstandsbrücke integriert. Diese dient zur Detektion von Druckänderungen. Mit Hilfe eines Mikroprozessors wird das Messsignal Temperatur und Druck kompensiert. Im letzten Herstellungsprozess werden die Druckschalter kalibriert, um so eine hohe Zuverlässigkeit und Genauigkeit garantieren zu können.</p><p>Auch dieser Druckschalter kann mit den Ausgangssignalen 0 &#8230;. 10 V, 4 &#8230;. 20 mA oder 0 &#8230;. 20 mA geliefert werden.</p><p>Der Druckschalter findet in Reinräumen, der Medizin- sowie Filter- und Ventialtionstechnik, in Klimakammern oder Kantinenküchen Anwendung.</p><p>Bei Bedarf kann jeder Druckschalter mit einem Kalibrierzertifikat, auf Wunsch auch mit DKD-Kalibrierung, geliefert werden.</p><p><strong><span id="more-48"></span></strong></p><div class="wp-caption alignright" style="width: 280px"><img class=" " title="Druckschalter" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/DDPTM-2.png" alt="DDPTM 2 Druckschalter" width="270" height="227" /><p class="wp-caption-text">Druckschalter mit LCD in Edelstahl</p></div><p><strong>Hinweise</strong></p><p>Sie dürfen diese Seite gerne verlinken!</p><p>Der Drucktransmitter ist wartungsfrei.</p><p>Diese Seite wurde mit Sorgfalt zusammengestellt. Es war jedoch nicht möglich, alle erdenklichen Anwendungsfälle zu berücksichtigen. Sollten Sie also Hinweise für Ihre spezielle Aufgabenstellung vermissen, nutzen Sie das Kontaktformular für Ihre Fragen.</p><p><strong>Sicherheitshinweis</strong></p><p>Beachten Sie unbedingt bei Montage, Inbetriebnahme und Betrieb dieser Drucksensoren die entsprechenden nationalen Sicherheitsvorschriften (z.B. DIN VDE 0100 Teil 410).</p><p><em>Irrtum und Änderungen im Sinne von technischen Verbesserungen vorbehalten.</em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>No related posts.</p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/48/druckschalter/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>Relativdruck</title><link>http://www.senti-solutions.com/43/relativdruck/</link> <comments>http://www.senti-solutions.com/43/relativdruck/#comments</comments> <pubDate>Mon, 31 Aug 2009 08:33:06 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[Drucksensor]]></category> <category><![CDATA[Relativdruck]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=43</guid> <description><![CDATA[Relativ-Drucktransmitter zum Erfassen von Relativdruck Wie arbeiten unsere Relativ-Drucktransmitter? Lesen Sie dies in unserer Zusammenfassung! Der Relativ-Drucktransducer kann in einer Ausführung in Edelstahl bezogen werden. Der Relativdruck kann damit in Flüssigkeiten und agressiven Medien gemessen werden. Bei deiser Konstruktion besteht das Messelement des Drucksensor aus einer Edelstahlmembran mit aufgebrachter Dünnschicht in Silizium-Technologie. Deshalb ist sichergestellt, [...]
Related posts:<ol><li><a href='http://www.senti-solutions.com/10/absolutdruck/' rel='bookmark' title='Absolutdruck'>Absolutdruck</a></li><li><a href='http://www.senti-solutions.com/37/differenzdruck/' rel='bookmark' title='Differenzdruck'>Differenzdruck</a></li></ol>]]></description> <content:encoded><![CDATA[<h2>Relativ-Drucktransmitter zum Erfassen von Relativdruck</h2><div class="wp-caption alignright" style="width: 280px"><img class=" " title="Relativdruck" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/BAPT-LCD.png" alt="BAPT LCD Relativdruck" width="270" height="270" /><p class="wp-caption-text">Relativ-Drucksensor mit LCD</p></div><h3>Wie arbeiten unsere Relativ-Drucktransmitter? Lesen Sie dies in unserer Zusammenfassung!</h3><p>Der Relativ-Drucktransducer kann in einer Ausführung in Edelstahl bezogen werden. Der Relativdruck kann damit in Flüssigkeiten und agressiven Medien gemessen werden. Bei deiser Konstruktion besteht das Messelement des Drucksensor aus einer Edelstahlmembran mit aufgebrachter Dünnschicht in Silizium-Technologie. Deshalb ist sichergestellt, dass alle Medien berührenden Teile komplett aus Edelstahl bestehen. Eine Wheatstone-Widerstansbrücke wird bei diesem Drucksensor zum Messen genutzt. Durch einen Mikrochip wird das Messsignal der Wheatstone-Widerstandsbrücke Temperatur und Druck kompensiert. Vor der Auslieferung der Relativ-Drucktransmitter werden diese kalibriert, um eine hohe Genauigkeit und Zuverlässigkeit sicher zu stellen.</p><p>Der Relativ-Drucktransmitter kann mit den Ausgangssignalen 0 &#8230;. 10 V, 4 &#8230;. 20 mA oder 0 &#8230;. 20 mA geordert werden.</p><p>Der Relativ-Drucksensor wird in der Pneumatik, der Prozess-Messtechnik und in der Gebäudetechnik eingesetzt und kann auch in einer EEx-Ausführung geliefert werden.</p><p>Jeder Relativ-Drucktransmitter kann auf Anfrage auch mit Kalibrierbeleg oder mit DKD-Kalibrierzertifikat geliefert werden.</p><p><strong><span id="more-43"></span></strong></p><div class="wp-caption aligncenter" style="width: 96px"><img class=" " title="Relativdruck" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/RSPT.png" alt="RSPT Relativdruck" width="86" height="270" /><p class="wp-caption-text">Relativ-Drucksensor in Edelstahl</p></div><p><strong>Hinweise</strong></p><p>Sie dürfen gerne zu dieser Seite Verlinken!</p><p>Der Drucktransmitter ist wartungsfrei.</p><p>Diese Seite wurde mit Sorgfalt zusammengestellt. Es war jedoch nicht möglich, alle erdenklichen Anwendungsfälle zu berücksichtigen. Sollten Sie also Hinweise für Ihre spezielle Aufgabenstellung vermissen, nutzen Sie das Kontaktformular für Ihre Fragen.</p><p><strong>Sicherheitshinweis</strong></p><p>Beachten Sie unbedingt bei Montage, Inbetriebnahme und Betrieb dieser Drucksensoren die entsprechenden nationalen Sicherheitsvorschriften (z.B. DIN VDE 0100 Teil 410).</p><p><em>Irrtümer und Änderungen im Sinne von technischen Verbesserungen vorbehalten.</em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>Related posts:<ol><li><a href='http://www.senti-solutions.com/10/absolutdruck/' rel='bookmark' title='Absolutdruck'>Absolutdruck</a></li><li><a href='http://www.senti-solutions.com/37/differenzdruck/' rel='bookmark' title='Differenzdruck'>Differenzdruck</a></li></ol></p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/43/relativdruck/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>Differenzdruck</title><link>http://www.senti-solutions.com/37/differenzdruck/</link> <comments>http://www.senti-solutions.com/37/differenzdruck/#comments</comments> <pubDate>Mon, 31 Aug 2009 08:14:47 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[Drucksensor]]></category> <category><![CDATA[Differenzdruck]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=37</guid> <description><![CDATA[Drucktransmitter für das Erfassen von Differenzdruck Wie unser Differenz-Drucksensor funktioniert? Erfahren Sie es in unserer Zusammenstellung! Der Differenzdruck in nicht-aggressiven Gasen und Umgebungen kann mittels eines Drucksensors für Differenzdruck erfasst werden. Der genutzte Differenz-Drucktransducer ist ein Drucksensor, welcher in Siliziumtechnologie hergestellt. Der Drucksensor nutzt eine Wheatstone-Widerstandsbrücke zum Erfassen der Druckänderung, welche in das Silizium eindiffundiert [...]
Related posts:<ol><li><a href='http://www.senti-solutions.com/10/absolutdruck/' rel='bookmark' title='Absolutdruck'>Absolutdruck</a></li><li><a href='http://www.senti-solutions.com/43/relativdruck/' rel='bookmark' title='Relativdruck'>Relativdruck</a></li></ol>]]></description> <content:encoded><![CDATA[<h2>Drucktransmitter für das Erfassen von Differenzdruck</h2><div class="wp-caption alignright" style="width: 280px"><img class=" " title="Differenzdruck" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/ALDPS-LCD.png" alt="ALDPS LCD Differenzdruck" width="270" height="270" /><p class="wp-caption-text">Differenz-Drucksensor mit LCD</p></div><h3>Wie unser Differenz-Drucksensor funktioniert? Erfahren Sie es in unserer Zusammenstellung!</h3><div class="wp-caption alignright" style="width: 280px"><img class=" " title="Differenzdruck" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/CALDPT-LCD.png" alt="CALDPT LCD Differenzdruck" width="270" height="253" /><p class="wp-caption-text">Differenz-Drucksensor mit LCD</p></div><p>Der Differenzdruck in nicht-aggressiven Gasen und Umgebungen kann mittels eines Drucksensors für Differenzdruck erfasst werden. Der genutzte Differenz-Drucktransducer ist ein Drucksensor, welcher in Siliziumtechnologie hergestellt. Der Drucksensor nutzt eine Wheatstone-Widerstandsbrücke zum Erfassen der Druckänderung, welche in das Silizium eindiffundiert ist. Das Messsignal wird mittels IC Temperatur und Druck kompensiert. Jeder Differenz-Drucktransducer wird am Ende des Montageprozesses kalibriert. Durch diese Maßnahme wird eine hohe Verlässlichkeit und Genauigkeit des Differenz-Drucksensor garantiert.</p><p>Der Differenz-Drucksensor kann mit unterschiedlichen Ausgangssignalen in Abhängigkeit der Anwendung hergestellt und bezogen werden. Außer den Normsignalen von 0 &#8230;. 10 V und 4 &#8230;. 20 mA kann der Differenz-Drucktransducer auch mit einem gSPI-Interface geliefert werden. Es ist ebenfalls möglich, den Drucktransmitter mit einem umschaltbaren Ausgangssignal zu liefern, so dass vor Ort mittels Jumper dieses geändert werden kann.</p><p>Das gSPI-Interface ist ein Bussystem. Bis zu 120 Drucktransmitter können an diesem betrieben werden. Differenz-Drucktransducer ohne gSPI-Interface können ebenfalls an diesem Bus betrieben werden. Sie werden mittels eines Buskoppler-Moduls an den gSPI-Bus angeschlossen.</p><p>Die Differenz-Drucktransmitter sind in Kunststoff-Gehäusen mit IP65. Alternativ können die Drucksensoren mit einem 4-digit LCD zum Anzeigen des Messwertes geliefert. Auf dem Display wird zusätzlich die Masseinheit dargestellt.</p><p>Der Druckmessumformer kann stattdessen auch mit einer Edelstahlmembran zur Messung von Differenzdruck geliefert werden. Damit kann der Differenzdruck in Flüssigkeiten und aggressiven Umgebungen erfasst werden. In dieser Ausführung besteht der Drucksensor aus einer Edelstahlmembran mit in Dünnschicht-Technologie aufgebrachtem Silizium. Aus diesem Grund ist sichergestellt, dass alle Medien berührenden Teile aus Edelstahl gefertigt sind. In das Silizium ist eine Wheatstone-Widerstandsbrücke integriert, welche zur Detektion der Druckänderungen genutzt wird. Das Messsignal der Wheatstone-Widerstandsbrücke wird mittels Mikroprozessor Temperatur und Druck kompensiert. Vor der Auslieferung der Differenz-Drucktransducer werden diese kalibriert, um eine hohe Zuverlässigkeit und Genauigkeit sicher zu stellen.</p><p>Es stehen Ausgangssignale mit 0 &#8230;. 10 V, 4 &#8230;. 20 mA sowie  0 &#8230;. 20 mA bei diesem Differenz-Drucktransmitter zur Verfügung.</p><p>Der Differenz-Drucksensor findet in Reinräumen, der Medizin- sowie Filter- und Ventialtionstechnik, in Klimakammern oder Kantinenküchen Anwendung.</p><p>Bei Bedarf kann jeder Differenz-Drucksensor mit einem Kalibrierzertifikat, auf Wunsch auch mit DKD-Kalibrierung, geliefert werden.</p><p><strong><span id="more-37"></span></strong></p><div class="wp-caption alignright" style="width: 280px"><img class=" " title="Differenzdruck" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/DDPTM-2.png" alt="DDPTM 2 Differenzdruck" width="270" height="227" /><p class="wp-caption-text">Differenz-Drucksensor mit LCD in Edelstahl</p></div><p><strong>Hinweise</strong></p><p>Sie dürfen diese Seite gerne verlinken!</p><p>Der Drucktransmitter ist wartungsfrei.</p><p>Diese Seite wurde mit Sorgfalt zusammengestellt. Es war jedoch nicht möglich, alle erdenklichen Anwendungsfälle zu berücksichtigen. Sollten Sie also Hinweise für Ihre spezielle Aufgabenstellung vermissen, nutzen Sie das Kontaktformular für Ihre Fragen.</p><p><strong>Sicherheitshinweis</strong><br /> Beachten Sie unbedingt bei Montage, Inbetriebnahme und Betrieb dieser Drucksensoren die entsprechenden nationalen Sicherheitsvorschriften (z.B. DIN VDE 0100 Teil 410).</p><p><em>Irrtum und Änderungen im Sinne von technischen Verbesserungen vorbehalten.</em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>Related posts:<ol><li><a href='http://www.senti-solutions.com/10/absolutdruck/' rel='bookmark' title='Absolutdruck'>Absolutdruck</a></li><li><a href='http://www.senti-solutions.com/43/relativdruck/' rel='bookmark' title='Relativdruck'>Relativdruck</a></li></ol></p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/37/differenzdruck/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>Absolutdruck</title><link>http://www.senti-solutions.com/10/absolutdruck/</link> <comments>http://www.senti-solutions.com/10/absolutdruck/#comments</comments> <pubDate>Sun, 30 Aug 2009 19:59:10 +0000</pubDate> <dc:creator>Carsten Köhler</dc:creator> <category><![CDATA[Drucksensor]]></category> <category><![CDATA[Absolutdruck]]></category><guid isPermaLink="false">http://www.senti-solutions.com/?p=10</guid> <description><![CDATA[Drucksensor zur Messung von Absolutdruck Wie funktionieren unsere Absolut-Drucktransmitter? Lesen Sie dies in unserer Beschreibung! Der barometrische Druck in nicht-aggressiven Gasen und Atmosphären kann mit dem Drucksensor zur Messung von Absolutdruck erfasst werden. Bei dem dabei eingesetzten Messelement handelt sich um einen in Siliziumtechnologie hergestellten Drucksensor. Dabei wird zur Erfassung der Druckänderung eine Wheatstone-Widerstands-Brücke eingesetzt, [...]
Related posts:<ol><li><a href='http://www.senti-solutions.com/37/differenzdruck/' rel='bookmark' title='Differenzdruck'>Differenzdruck</a></li><li><a href='http://www.senti-solutions.com/43/relativdruck/' rel='bookmark' title='Relativdruck'>Relativdruck</a></li></ol>]]></description> <content:encoded><![CDATA[<div id="attachment_20" class="wp-caption alignright" style="width: 280px"><img class="size-full wp-image-20    " title="Absolutdruck" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/BAPT-LCD.png" alt="BAPT LCD Absolutdruck" width="270" height="270" /><p class="wp-caption-text">Absolut-Drucksensor mit LCD</p></div><h2>Drucksensor zur Messung von Absolutdruck</h2><h3>Wie funktionieren unsere Absolut-Drucktransmitter? Lesen Sie dies in unserer Beschreibung!</h3><p>Der barometrische Druck in nicht-aggressiven Gasen und Atmosphären kann mit dem Drucksensor zur Messung von Absolutdruck erfasst werden. Bei dem dabei eingesetzten Messelement handelt sich um einen in Siliziumtechnologie hergestellten Drucksensor. Dabei wird zur Erfassung der Druckänderung eine Wheatstone-Widerstands-Brücke eingesetzt, welche in das Siliziumkristall eindiffundiert wurde. Deren Messsignal wird mittels Mikroprozessor temperatur- und druckkompensiert. Dabei wird jeder Drucktransmitter während des Herstellungsprozesses einer Kalibrierung unterzogen. Dadurch wird eine hohe Zuverlässigkeit und Genauigkeit des Drucksensors garantiert.</p><p>Als Ausgangssignal stehen je nach Anwendungsfall verschiedene Signale zur Verfügung. Neben den Normsignalen von 0 &#8230; 10 V oder 4 &#8230; 20 mA können die Drucktransmitter für Absolutdruck auch mit einem gSPI-Interface geliefert werden. Ebenfalls ist es möglich, Absolutdruck Drucksensoren mit kombinierten Ausgangssignalen zu liefern, so dass am Einsatzort mittels Jumper das Ausgangssignal gewählt werden kann.</p><p>Das gSPI-Interface ist ein Bussystem. An diesem können bis zu 120 Drucktransmitter betrieben werden. Der Anschluß von Drucksensoren  für Absolutdruck ohne gSPI-Interface erfolgt über Buskopplermodule an den gSPI-Bus.</p><p>Die Druckmessumformer werden in einem Kunststoffgehäuse in IP65 verbaut. Optional kann der Druckmessumformer mit einem 4-stelligen LCD zur Anzeige des Messwerts ausgestattet werden. Neben dem Messwert wird auch die Einheit auf dem Display angezeigt.</p><p>Alternativ kann der Druckmessumformer für Absolutdruck auch in einer Edelstahlausführung geliefert werden. Damit kann der Absolutdruck in Flüssigkeiten und aggressiven Medien detektiert werden. Bei dieser Ausführung besteht das Messelement aus einem in Dünnfilmtechnologie auf einer Edelstahlmembran aufgebrachten Drucksensor. Somit wird garantiert, dass alle medienberührenden Teile komplett aus Edelstahl bestehen. Auch bei diesem Drucksensor wird eine Wheatstone-Widerstands-Brücke zur Detektion eingesetzt. Durch Einsatz eines Mikroprozessors wird das Messsignal der Wheatstone-Brücke temperatur- und druckkompensiert. Auch dieser Drucksensor wird vor Auslieferung einer Kalibrierung unterzogen, um eine hohe Genauigkeit und Zuverlässigkeit garantieren zu können.</p><p>Dieser Druckmessumformer kann mit den Ausgangssignalen  0 &#8230; 10 V, 4 &#8230; 20 mA oder 0 &#8230; 20 mA geliefert werden.</p><p>Der Einsatz dieser Drucktransmitter für Absolutdruck erfolgt in der Reinraum-, Medizin- und Filtertechnik, in Lüftungs- und Klimakanälen, in Spritzkabinen oder in Großküchen.</p><p>Jeder Absolutdruck Drucksensor kann auf Wunsch mit Kalibrierzertifikat, auch mit DKD-Kalibrierzertifikat, geliefert werden.</p><p><span id="more-10"></span></p><div class="wp-caption aligncenter" style="width: 96px"><img class=" " title="Absolutdruck" src="http://www.senti-solutions.com/wp-content/uploads/2009/08/RSPT.png" alt="RSPT Absolutdruck" width="86" height="270" /><p class="wp-caption-text">Absolut-Drucksensor in Edelstahl</p></div><p><strong>Hinweise</strong><br /> Sie dürfen diese Seite gerne Verlinken!</p><p>Der Drucktransmitter ist wartungsfrei.</p><p>Diese Seite wurde mit Sorgfalt zusammengestellt. Es war jedoch nicht möglich, alle erdenklichen Anwendungsfälle zu berücksichtigen. Sollten Sie also Hinweise für Ihre spezielle Aufgabenstellung vermissen, nutzen Sie das Kontaktformular für Ihre Fragen.</p><p><strong>Sicherheitshinweis</strong><br /> Beachten Sie unbedingt bei Montage, Inbetriebnahme und Betrieb dieser Drucksensoren die entsprechenden nationalen Sicherheitsvorschriften (z.B. DIN VDE 0100 Teil 410).</p><p><em>Irrtümer und Änderungen im Sinne von technischen Verbesserungen vorbehalten.</em></p><p><script type="text/javascript">google_ad_client = "pub-5562079894310570";
/* 468x15, Erstellt 30.08.09 */
google_ad_slot = "2952855625";
google_ad_width = 468;
google_ad_height = 15;</script> <script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js"></script></p> Note: There is a print link embedded within this post, please visit this post to print it.<p>Related posts:<ol><li><a href='http://www.senti-solutions.com/37/differenzdruck/' rel='bookmark' title='Differenzdruck'>Differenzdruck</a></li><li><a href='http://www.senti-solutions.com/43/relativdruck/' rel='bookmark' title='Relativdruck'>Relativdruck</a></li></ol></p>]]></content:encoded> <wfw:commentRss>http://www.senti-solutions.com/10/absolutdruck/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> </channel> </rss><!-- Dynamic page generated in 2.149 seconds. --><!-- Cached page generated by WP-Super-Cache on 2012-04-23 04:55:19 -->

