<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:blogger='http://schemas.google.com/blogger/2008' xmlns:georss='http://www.georss.org/georss' xmlns:gd="http://schemas.google.com/g/2005" xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-5258199284457172455</id><updated>2024-11-08T07:06:53.891-08:00</updated><title type='text'>VERIL TRANSFORMER</title><subtitle type='html'>&quot; To place SERVICE before PROFIT &quot;</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://veriltransformer.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5258199284457172455/posts/default?redirect=false'/><link rel='alternate' type='text/html' href='http://veriltransformer.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>Veril Transformer</name><uri>http://www.blogger.com/profile/05952253275306918091</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://3.bp.blogspot.com/_xtYS46MU4Ck/TMAB2WEzjaI/AAAAAAAAAAY/2TQk7euFGN4/S220/xformer+2-2.jpg'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>1</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-5258199284457172455.post-6123245693219393810</id><published>2010-10-21T02:48:00.000-07:00</published><updated>2010-10-21T04:41:11.133-07:00</updated><title type='text'>Dry Type Transformers</title><content type='html'>&lt;b&gt;&lt;i&gt;Dry-Type Transformers&lt;/i&gt;&lt;/b&gt; are for indoor and outdoor applications    in schools, hospitals, industrial plants, commercial buildings and    anywhere that safe and dependable power are important considerations.&lt;br /&gt;
&lt;br /&gt;
&lt;u&gt;&lt;i&gt;Dry-type transformers&lt;/i&gt;&lt;/u&gt; can have their windings insulated various ways. A    basic method is to preheat the conductor coils and then, when heated,    dip them in varnish at a high temperature. The coils are then baked to    cure the varnish. This process is an open-wound method and helps ensure    penetration of the varnish. Cooling ducts in the windings provide an    efficient and economical way to remove the heat produced by the    electrical losses of the transformer by allowing air to flow through the    duct openings. This dry-type insulation system operates satisfactorily    in most ambient conditions are also sealed with an epoxy resin mixture.&lt;br /&gt;
&lt;br /&gt;
Another version of the &lt;i&gt;&lt;b&gt;dry-type transformer&lt;/b&gt;&lt;/i&gt; is a cast coil insulation system.        It is used when addition coil        strength and protection are advisable. Theses type of        transformer are used in located&amp;nbsp; where environments        are harsh,&amp;nbsp; such as cement and chemical plants and        outdoor installations where moisture, salt spray,        corrosive fumes, dust, and metal particles can destroy        other types of dry-type transformers. These cast coil        units are better able to withstand heavy power surges,        such as frequent but brief overloads experienced by        transformers serving transit systems and various        industrial machinery. Cast coil units&amp;nbsp; are now being        used where previously only liquid-filled units were        available for harsh environments. They can have the same        high levels of BIL while still providing ample        protection of the coils and the leads going to the        terminals.&lt;br /&gt;
&lt;br /&gt;
Information on &lt;b&gt;&lt;i&gt;dry-type transformer&lt;/i&gt;&lt;/b&gt; loading from ANSI/EEE        C57.96-1989 indicates that you can have a 20-yr life        expectancy for the insulation system in a transformer.        For        dry-type transformers having a 220 (degrees) C,        insulating system and a winding hot-spot temperature of        220 (degrees) C, and with no unusual operating        conditions present, the 20 yr life expectancy is a        reasonable time fame. However, due to degradation of the        insulation, a transformer might fail before 20 years. Most 150 (degrees) C rise dry-type transformers are    build with 220 (degrees) C insulation systems. Operating such a    transformer at rated kVA on a continuous basis with a 30 (degrees) C    average ambient should equate to a &quot;normal&quot; useful life.&lt;br /&gt;
&lt;br /&gt;
The life of a    transformer increases appreciably if the operating temperature is lower    than the maximum temperature rating of the insulation. However, you    should recognize that the life expectancy of transformers operating at    varying temperatures is not accurately known. Fluctuating load    conditions and changes in ambient temperature make it difficult, if not    impossible, to arrive at such definitive information.&lt;br /&gt;
&lt;br /&gt;
Dry-type transformers are available in three general    classes of insulation. The main features of insulation are to provide    dielectric strength and to be be able to withstand certain thermal    limits. Insulation classes are 220(degrees) C (Class H). 185 (degrees) C    (Class F), and 150 (degrees) C (Class B). Temperature rise ratings are    based on full-load rise over ambient (usually 40 (degrees) C above    ambient and are 150 (degrees) C (available only with Class H    insulation), 115 (degrees) C (available with Class H and Class F    insulation) and 80 (degrees) C (available with Class H, F, and B    insulation). A 30 (degrees) C winding hot spot allowance is provided for    each class.&lt;br /&gt;
&lt;br /&gt;
The lower temperature rise transformers are more    efficient, particularly at loadings of 50% and higher. Full load losses    for 115 (degrees) C transformers are about 30% less that those of 150    (degrees) C transformers. And 80 (degrees) C transformers have losses    that are about 15% less than 115 (degrees) C transformers and 40% less    than 150 (degrees) C transformers. Full load losses for 150 (degrees) C    transformers range from about 4% to 5% to 30 kVA and smaller to 2% for    500 kVA and larger.&lt;br /&gt;
&lt;br /&gt;
When operated continuously at 65% or more of full load,    the 115 (degrees) C transformer will pay for itself over&amp;nbsp; the 150    (degrees) C transformer in 2 yrs or less( 1 yr. if operated at 90% of    full load). the 80 (degrees) C transformer requires operation at 75% or    more of full load for a 2-yr payback, and at 100% load to payback in 1    yr over the 150 (degrees) C transformer. If operated continuously at 80%    or more of full load, the 80 (degrees) C transformer will have a payback    over the 115 (degrees) C transformer in 2 yrs or less.&lt;br /&gt;
&lt;br /&gt;
You should note that at loadings below 50% of full load,        there is essentially no payback for either the 115        (degrees) C or the 80 (degrees) C transformer over the        150 (degrees) C transformer, Also at loadings below 40%        the lower temperature rise transformers become less        efficient that the 150 (degrees) C transformers. Thus,        not only is there no payback, but also the annual        operating cost is higher.&lt;br /&gt;
&lt;br /&gt;
&lt;div style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: large;&quot;&gt;&lt;a href=&quot;http://veriltransformer.webs.com/&quot;&gt;veriltransformer.webs.com&lt;/a&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://veriltransformer.blogspot.com/feeds/6123245693219393810/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://veriltransformer.blogspot.com/2010/10/dry-type-transformers.html#comment-form' title='3 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/5258199284457172455/posts/default/6123245693219393810'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/5258199284457172455/posts/default/6123245693219393810'/><link rel='alternate' type='text/html' href='http://veriltransformer.blogspot.com/2010/10/dry-type-transformers.html' title='Dry Type Transformers'/><author><name>Veril Transformer</name><uri>http://www.blogger.com/profile/05952253275306918091</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='30' height='32' src='http://3.bp.blogspot.com/_xtYS46MU4Ck/TMAB2WEzjaI/AAAAAAAAAAY/2TQk7euFGN4/S220/xformer+2-2.jpg'/></author><thr:total>3</thr:total></entry></feed>