<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:blogger='http://schemas.google.com/blogger/2008' xmlns:georss='http://www.georss.org/georss' xmlns:gd="http://schemas.google.com/g/2005" xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-1374807488486422555</id><updated>2024-09-04T15:34:30.920-07:00</updated><category term="HCI"/><category term="VMWARE"/><category term="VSAN"/><title type='text'>Virtualization &amp;amp; Storage</title><subtitle type='html'></subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default?redirect=false'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>9</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>25</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-8649953008836504929</id><published>2018-10-26T02:27:00.000-07:00</published><updated>2018-10-26T02:27:31.855-07:00</updated><category scheme="http://www.blogger.com/atom/ns#" term="HCI"/><category scheme="http://www.blogger.com/atom/ns#" term="VMWARE"/><category scheme="http://www.blogger.com/atom/ns#" term="VSAN"/><title type='text'>VSAN - Políticas de almacenamiento. Demostración en video.</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
En este video podemos ver como utilizar las políticas de almacenamiento en VSAN de forma dinámica y cambiar el almacenamiento de la VM sin apagarla.&lt;br /&gt;
&lt;br /&gt;
Podemos ver el tiempo que necesita para arrancar la VM, como creamos después una política que limita las IOPSy la VM tiene una respuesta mucho más lenta al arrancar y finalmente como al cambiar de nuevo la política con la VM en marcha vuelve a tner buen rendimiento.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;iframe allowfullscreen=&#39;allowfullscreen&#39; webkitallowfullscreen=&#39;webkitallowfullscreen&#39; mozallowfullscreen=&#39;mozallowfullscreen&#39; width=&#39;320&#39; height=&#39;266&#39; src=&#39;https://www.blogger.com/video.g?token=AD6v5dxcU3ysrJVfL-oLleA1FIIubRxW0wGKCfu-iHbIqiX4T0Rhj4XOECUJZWIqh1WfGJ5mql_BiVaDMBAQT1l88Q&#39; class=&#39;b-hbp-video b-uploaded&#39; frameborder=&#39;0&#39;&gt;&lt;/iframe&gt;&lt;/div&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;https://www.linkedin.com/in/raul-de-la-flor-valls-904a6448/&quot;&gt;
&lt;img border=&quot;0&quot; src=&quot;http://www.linkedin.com/img/webpromo/btn_myprofile_160x33.png&quot; id=&quot;linkedinImg&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/8649953008836504929/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2018/10/vsan-politicas-de-almacenamiento.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/8649953008836504929'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/8649953008836504929'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2018/10/vsan-politicas-de-almacenamiento.html' title='VSAN - Políticas de almacenamiento. Demostración en video.'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-7799011551655825411</id><published>2013-11-29T03:29:00.005-08:00</published><updated>2013-11-29T03:29:41.345-08:00</updated><title type='text'>EMC VNX 5200 VIA initialization fails writing sysadmin password</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
We just initialized a new VNX 5200 and after finishing we couldn&#39;t log in with the new sysadmin password we choose. However we could log as root and nasadmin.&lt;br /&gt;
&lt;br /&gt;
So we created a new global user &amp;nbsp;called temp from ssh connection to the CS and accessed unisphere with the new user and changed sysadmin password.&lt;br /&gt;
&lt;br /&gt;
Below &amp;nbsp;you can see the command we used:&lt;br /&gt;
&lt;br /&gt;
&lt;b&gt;&lt;i&gt;navicli -h spa security -adduser -user temp -password temp -scope 0 -role administrator&lt;/i&gt;&lt;/b&gt;&lt;br /&gt;
&lt;br /&gt;
Finally we could enter Unisphere with sysadmin and finish the installation.&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/7799011551655825411/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2013/11/emc-vnx-5200-via-initialization-fails.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/7799011551655825411'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/7799011551655825411'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2013/11/emc-vnx-5200-via-initialization-fails.html' title='EMC VNX 5200 VIA initialization fails writing sysadmin password'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-1422174599799417721</id><published>2013-09-26T23:42:00.001-07:00</published><updated>2013-09-26T23:42:02.980-07:00</updated><title type='text'>Error installing Exchange 2013 CU2 on Exchange 2007 organization</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Yesterday I installed for first time a new Exchange 2013 on a company with Exchange 2007. We have installed some new 2013 Exchange but this was the first migration.&lt;br /&gt;
&lt;br /&gt;
After accomplish all prerequisites on Microsoft guides we started to install and it ended on error.&lt;br /&gt;
&lt;br /&gt;
The error was &quot;length of the property is too long the maximum length is 64&quot; and it was close to a line referring to Offline Address Book.&lt;br /&gt;
&lt;br /&gt;
In Spanish the OAB was named &quot;Libreta de direcciones sin conexión de exchange&quot;.&lt;br /&gt;
&lt;br /&gt;
I googled a little and couldn&#39;t find any reference to this error and finally just tried something.&lt;br /&gt;
&lt;br /&gt;
I just renamed the OAB to &quot;OAB&quot; and tried again to install.&lt;br /&gt;
&lt;br /&gt;
This time installation finished OK!!!&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/1422174599799417721/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2013/09/error-installing-exchange-2013-cu2-on.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/1422174599799417721'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/1422174599799417721'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2013/09/error-installing-exchange-2013-cu2-on.html' title='Error installing Exchange 2013 CU2 on Exchange 2007 organization'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-4091077647536652463</id><published>2013-07-01T04:10:00.000-07:00</published><updated>2013-07-01T04:15:48.376-07:00</updated><title type='text'>EMC File  Replication VNX to VNXe</title><content type='html'>Recently we needed to configure File replication from a VNX array to a VNXe.&lt;br /&gt;
I searched EMC support and communities and it was a surprise that there was no documentation or guide.&lt;br /&gt;
&lt;br /&gt;
I have to look for the compatibility matrix again to see if it was possible.&lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;https://elabnavigator.emc.com/vault/pdf/EMC_VNXe_ESSM.pdf&quot;&gt;https://elabnavigator.emc.com/vault/pdf/EMC_VNXe_ESSM.pdf&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
Then I tried to do the inverse &amp;nbsp;one, VNXe to VNX as I had a manual.&lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;https://www.ndm.net/emcvnx/pdf/vnx/h8270-replicating-vnxe-cifs-nfs-shared-folders-vnx.pdf&quot;&gt;https://www.ndm.net/emcvnx/pdf/vnx/h8270-replicating-vnxe-cifs-nfs-shared-folders-vnx.pdf&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
At first time I had a problem establishing the trust &amp;nbsp;and finally it result I needed to add a route at DataMover level on the VNX since the two arrays are in different subnets.&lt;br /&gt;
&lt;br /&gt;
Once I got this solved I followed instructions and it worked fine. Also I tried to make a switch-over on replication and also worked.&lt;br /&gt;
&lt;br /&gt;
Now I created a Replication Destination on Shared Folders screen of the VNXe. The wizard asked which one was the origin and created a Shared folder mounted as only read and with the right size and protection size.&lt;br /&gt;
&lt;br /&gt;
When I tried to set a new replication from VNX as I entered the VNXe as destination the Unisphere screen failed.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;/div&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj34Vj-1isARFQH8jpD81sUJN5b89S4wd_1yOCBaUrWBX-Xi76GBZYqbla4HQ17kBJhpgKIec73jtUIhIV-XEhavHIfJvmTeaLw9-FiFHDNkjk119iEJY2FGLz6K8xp0y8FHeADr0XMODk/s869/screnshot1.jpg&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;445&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj34Vj-1isARFQH8jpD81sUJN5b89S4wd_1yOCBaUrWBX-Xi76GBZYqbla4HQ17kBJhpgKIec73jtUIhIV-XEhavHIfJvmTeaLw9-FiFHDNkjk119iEJY2FGLz6K8xp0y8FHeADr0XMODk/s869/screnshot1.jpg&quot; width=&quot;640&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;span style=&quot;font-family: &amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;; font-size: 11.0pt; mso-ansi-language: ES; mso-bidi-font-family: &amp;quot;Times New Roman&amp;quot;; mso-bidi-language: AR-SA; mso-fareast-font-family: Calibri; mso-fareast-language: ES; mso-fareast-theme-font: minor-latin;&quot;&gt;&lt;br /&gt;&lt;!--[endif]--&gt;&lt;/span&gt;
&lt;span style=&quot;font-family: &amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;; font-size: 11.0pt; mso-ansi-language: ES; mso-bidi-font-family: &amp;quot;Times New Roman&amp;quot;; mso-bidi-language: AR-SA; mso-fareast-font-family: Calibri; mso-fareast-language: ES; mso-fareast-theme-font: minor-latin;&quot;&gt;I then tried to look for info about doing it on commands from Control Station and I found a blog where some one had the same problem. Thanks to Jon Austin by the way.&lt;/span&gt;&lt;br /&gt;
&lt;span style=&quot;font-family: &amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;; font-size: 11.0pt; mso-ansi-language: ES; mso-bidi-font-family: &amp;quot;Times New Roman&amp;quot;; mso-bidi-language: AR-SA; mso-fareast-font-family: Calibri; mso-fareast-language: ES; mso-fareast-theme-font: minor-latin;&quot;&gt;&lt;br /&gt;&lt;/span&gt;
&lt;a href=&quot;http://www.integrateddatastorage.com/blog/2011/11/04/fun-with-darts/&quot;&gt;http://www.integrateddatastorage.com/blog/2011/11/04/fun-with-darts/&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
The main problem was how to know the destination FS ID on the vnxe system.&lt;br /&gt;
&lt;br /&gt;
So I connected to ssh on both arrays.&lt;br /&gt;
&lt;br /&gt;
On vnxe I logged as service and entered the service password which was the same that admin one.&lt;br /&gt;
I executed &amp;nbsp;&lt;i&gt;&lt;span style=&quot;color: blue;&quot;&gt;svc_service_shell &lt;/span&gt;&lt;/i&gt;so I could use commands on the VNXe.&lt;br /&gt;
I don&#39;t know the password for that since some one form &amp;nbsp;support put it the day before for other thing and there is a time when it expires. It looks like it takes a couple of days until it expires.&lt;br /&gt;
&lt;br /&gt;
Then I executed&lt;i&gt;&lt;span style=&quot;color: blue;&quot;&gt;&amp;nbsp;/nas/bin/nas_fs -list&lt;/span&gt;&lt;/i&gt; &amp;nbsp;so I could see the ID for the replication FS.&lt;br /&gt;
&lt;br /&gt;
After I logged on &amp;nbsp;VNX CS with ssh as nasadmin user&lt;br /&gt;
&lt;br /&gt;
I executed&amp;nbsp;&lt;span style=&quot;color: blue; font-style: italic;&quot;&gt;&amp;nbsp;nas_cel -interconnect -list &lt;/span&gt;so I could see the interconnect id (VNXe SPA) &amp;nbsp;where the destination FS was published.&lt;br /&gt;
&lt;br /&gt;
and &amp;nbsp;finally executed this command and finally got replication started!!!&lt;br /&gt;
&lt;br /&gt;
&lt;span style=&quot;color: blue;&quot;&gt;&lt;i&gt;&amp;nbsp;nas_replicate -create FS_Name -source -fs id=13 -destination -fs id=42 -interconnect id=20004 &amp;nbsp;-source_interface ip=x.x.x.x -destination_interface ip=x.x.x.x -max_time_out_of_sync 10 -overwrite&lt;/i&gt;&lt;/span&gt;&lt;br /&gt;
&lt;br /&gt;
Overwrite option was needed because it fails other way.&lt;br /&gt;
&lt;br /&gt;
That was all, after 20 hours file system is replicated and working fine.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;br /&gt;</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/4091077647536652463/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2013/07/emc-file-replication-vnx-to-vnxe.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/4091077647536652463'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/4091077647536652463'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2013/07/emc-file-replication-vnx-to-vnxe.html' title='EMC File  Replication VNX to VNXe'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj34Vj-1isARFQH8jpD81sUJN5b89S4wd_1yOCBaUrWBX-Xi76GBZYqbla4HQ17kBJhpgKIec73jtUIhIV-XEhavHIfJvmTeaLw9-FiFHDNkjk119iEJY2FGLz6K8xp0y8FHeADr0XMODk/s72-c/screnshot1.jpg" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-304514322217717268</id><published>2012-10-15T03:13:00.000-07:00</published><updated>2012-10-15T03:13:36.823-07:00</updated><title type='text'>Error 3221684229 Installing Exchange 2007 (Mailbox Role) - On Windows Server 2008 R2 and  OWA not working</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Hi,&lt;br /&gt;
&lt;br /&gt;
this post is composed by a couple of issues that can appear when migrating exchange 2003 to 2007.&lt;br /&gt;
Since Exchange 2007 is an old software if you install it today on a Windows 2008 R2 Server you can get this error:&amp;nbsp;Error 3221684229 Installing Exchange 2007 Mailbox Role.&lt;br /&gt;
&lt;br /&gt;
I found this post that helped me out.&lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;http://www.petenetlive.com/KB/Article/0000262.htm&quot;&gt;http://www.petenetlive.com/KB/Article/0000262.htm&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
Solution as easy as running the installer on Vista &amp;nbsp;compatibility mode.&lt;br /&gt;
&lt;br /&gt;
This generated next problem, it was a typical install and all roles where installed except the mailbox.&lt;br /&gt;
After changing compatibility mode I added Mailbox Role.&lt;br /&gt;
&lt;br /&gt;
Then we starting trying the server and OWA web page appeared but it didn&#39;t&amp;nbsp;authenticate.&lt;br /&gt;
Finally I found two posts that help me out:&lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;http://exchangeserverpro.com/modifying-exchange-server-2007-roles-breaks-outlook-web-access#comment-10670&quot;&gt;http://exchangeserverpro.com/modifying-exchange-server-2007-roles-breaks-outlook-web-access&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;http://itproafrica.com/technology/exchange/owa-broken-on-exchange-2007-on-windows-2008-red-x-appear-instead-of-web-pages/&quot;&gt;http://itproafrica.com/technology/exchange/owa-broken-on-exchange-2007-on-windows-2008-red-x-appear-instead-of-web-pages/&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
We needed to install Exchange SP3 and review IIS prerequisites.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;&lt;/div&gt;
</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/304514322217717268/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/10/error-3221684229-installing-exchange.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/304514322217717268'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/304514322217717268'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/10/error-3221684229-installing-exchange.html' title='Error 3221684229 Installing Exchange 2007 (Mailbox Role) - On Windows Server 2008 R2 and  OWA not working'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-5251283046895000776</id><published>2012-07-30T23:57:00.001-07:00</published><updated>2012-07-30T23:57:04.305-07:00</updated><title type='text'>VMWARE VIEW Problem  cloning master image for linked clones on v5.1</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
On a small new&amp;nbsp;installation of Vmware View 5.1 we had problems when creating linked clone pools.&lt;br /&gt;
It is a lab install on SATA disk and cloning takes about 70 minutes.&lt;br /&gt;
It always finished with an error &quot;Connection Server - View Composer Fault: VC operation exceeded the task
 timeout limit of 0 mins set by the View Composer for &amp;lt;VM 
instance&amp;gt;&quot;&lt;br /&gt;
So after googling a lite bit I &amp;nbsp;founf some post on Vmware communities&amp;nbsp;&amp;nbsp; that solved the problem.&lt;br /&gt;
&lt;br /&gt;
&lt;a href=&quot;http://communities.vmware.com/message/2063937&quot;&gt;http://communities.vmware.com/message/2063937&lt;/a&gt;&lt;br /&gt;
&lt;br /&gt;
Thanks to&amp;nbsp;hettefagh I could solve my problem.&lt;br /&gt;
&lt;br /&gt;
Here you can read the solution:&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
1. Stopped the View Composer service.&lt;br /&gt;
&lt;div style=&quot;height: 8pt; min-height: 8pt; padding: 0px;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
2.
 Made a backup copy of C:\Program Files (x86)\VMware\VMware View Composer\SviWebService.exe.config and saved in the same folder.&lt;br /&gt;
&lt;div style=&quot;height: 8pt; min-height: 8pt; padding: 0px;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
3. Edited the SviWebService.exe.config and changed the line&lt;br /&gt;
&lt;div style=&quot;height: 8pt; min-height: 8pt; padding: 0px;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&amp;lt;VirtualCenter PropertyCollectorTimeout=&quot;60&quot; /&amp;gt;&lt;br /&gt;
&lt;div style=&quot;height: 8pt; min-height: 8pt; padding: 0px;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
to read&lt;br /&gt;
&lt;div style=&quot;height: 8pt; min-height: 8pt; padding: 0px;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&amp;lt;VirtualCenter PropertyCollectorTimeout=&quot;60&quot; VcTaskTimeout=&quot;90&quot; /&amp;gt;&lt;br /&gt;
&lt;div style=&quot;height: 8pt; min-height: 8pt; padding: 0px;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
4. Saved the change and restarted Composer.&amp;nbsp; Confirmed the service is running again without error.&lt;br /&gt;
&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/5251283046895000776/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/07/vmware-view-problem-cloning-master.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/5251283046895000776'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/5251283046895000776'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/07/vmware-view-problem-cloning-master.html' title='VMWARE VIEW Problem  cloning master image for linked clones on v5.1'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-2355296803627608874</id><published>2012-03-07T08:58:00.000-08:00</published><updated>2012-03-07T08:59:25.717-08:00</updated><title type='text'>Esxi5 disconnected and responding ping.</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
&lt;br /&gt;
Recently we have some serious problems on a small project implementation.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
We had 2 Cisco UCS C200 M2 servers, 2 Cisco MDS9148 and a EMC VNX5100 storage array.&lt;br /&gt;
The servers used Qlogic 8GB Fiber channel cards. The problem&amp;nbsp;appeared&amp;nbsp;always on heavy storage use (backup tasks mostly), but it could be once a week.&lt;br /&gt;
&lt;br /&gt;
When&amp;nbsp;accessing&amp;nbsp;to the esxi console you could write user and password but you could not enter.&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;separator&quot; style=&quot;clear: both; text-align: center;&quot;&gt;
&lt;a href=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjBpfdj3jOiSvaaph82xHdAYFVCHWjgQO9V487uUZBCh3lWGcc0fZKpQmZKTB3HJ5aTw5R9kZTrrKsUeMPwLWAn4-Di36YxQ-wfjvKG4Lp5U7u5HG4xehClilYmtNwCb6e7fDldhf8LIiU/s1600/Captura.JPG&quot; imageanchor=&quot;1&quot; style=&quot;margin-left: 1em; margin-right: 1em;&quot;&gt;&lt;img border=&quot;0&quot; height=&quot;145&quot; src=&quot;https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjBpfdj3jOiSvaaph82xHdAYFVCHWjgQO9V487uUZBCh3lWGcc0fZKpQmZKTB3HJ5aTw5R9kZTrrKsUeMPwLWAn4-Di36YxQ-wfjvKG4Lp5U7u5HG4xehClilYmtNwCb6e7fDldhf8LIiU/s320/Captura.JPG&quot; width=&quot;320&quot; /&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
After that you needed to restart the Esxi and Virtual Machines were down.&lt;br /&gt;
&lt;br /&gt;
I&amp;nbsp;opened&amp;nbsp;a SR on VMware but solved the problem before they answer.&lt;br /&gt;
&lt;br /&gt;
After looking at vmkernel.log I searched on Google for info about errors appearing and finally I founded a KB Article that was very interesting:&lt;br /&gt;
&lt;br /&gt;
&lt;h2&gt;

&lt;a href=&quot;http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;amp;cmd=displayKC&amp;amp;externalId=1030265&quot;&gt;vHBAs and other PCI devices may stop responding in ESX/ESXi 4.1 and ESXi 5.0 when using Interrupt Remapping&lt;/a&gt;&lt;/h2&gt;
&lt;div&gt;
&lt;br /&gt;
Also I founded at Vmware &amp;nbsp;communities &amp;nbsp;&amp;nbsp;some&amp;nbsp;&amp;nbsp;threads&amp;nbsp;with same case:&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
&lt;a href=&quot;http://communities.vmware.com/message/1983041&quot;&gt;http://communities.vmware.com/message/1983041&lt;/a&gt;&amp;nbsp;(Cisco servers)&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
&lt;a href=&quot;http://communities.vmware.com/thread/341512&quot;&gt;http://communities.vmware.com/thread/341512 &lt;/a&gt;&amp;nbsp;(IBM, Supermicro)&amp;nbsp;&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
We execute the actions in the KB and everything is working fine after 20 days.&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;div&gt;
Hope this helps others on searching solutions!!&lt;/div&gt;
&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/2355296803627608874/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/03/esxi5-disconnected-and-responding-ping.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/2355296803627608874'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/2355296803627608874'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/03/esxi5-disconnected-and-responding-ping.html' title='Esxi5 disconnected and responding ping.'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><media:thumbnail xmlns:media="http://search.yahoo.com/mrss/" url="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjBpfdj3jOiSvaaph82xHdAYFVCHWjgQO9V487uUZBCh3lWGcc0fZKpQmZKTB3HJ5aTw5R9kZTrrKsUeMPwLWAn4-Di36YxQ-wfjvKG4Lp5U7u5HG4xehClilYmtNwCb6e7fDldhf8LIiU/s72-c/Captura.JPG" height="72" width="72"/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-9152650577971095162</id><published>2012-02-24T00:51:00.002-08:00</published><updated>2012-02-24T00:51:46.737-08:00</updated><title type='text'>VMWARE Data Recovery Plugin: Error could not connect to the Data Recovery Service on the Appliance</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Some times after&amp;nbsp;installing Data Recovery Plugin you can&#39;t connect to the appliance. You get this message:&amp;nbsp;&amp;nbsp;&lt;i&gt;Error could not connect to the Data Recovery Service on the Appliance.&lt;/i&gt;&lt;br /&gt;
The curious thing is that you can&#39;t connect from vSphere client installed on VCenter or other desktops.&lt;br /&gt;
I found a solution on Vmware communities. You need to rename some dlls and it will work again.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-indent: 35.4pt;&quot;&gt;
&lt;i&gt;&lt;span lang=&quot;EN-US&quot; style=&quot;color: #1f497d; font-family: &amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;; font-size: 11.0pt; mso-ansi-language: EN-US;&quot;&gt;Renaming &amp;nbsp;C:\Windows\System32\libeay32.dll and
C:\Windows\System32\ ssleay32.dll and rebooting - all works fine.&lt;/span&gt;&lt;/i&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-indent: 35.4pt;&quot;&gt;
&lt;i&gt;&lt;span lang=&quot;EN-US&quot; style=&quot;color: #1f497d; font-family: &amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;; font-size: 11.0pt; mso-ansi-language: EN-US;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/i&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-indent: 35.4pt;&quot;&gt;
&lt;span lang=&quot;EN-US&quot;&gt;&lt;span style=&quot;color: #1f497d; font-family: Calibri, sans-serif;&quot;&gt;&lt;span style=&quot;font-size: 11pt;&quot;&gt;I found that on this&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 15px;&quot;&gt;thread&lt;/span&gt;&lt;span style=&quot;font-size: 11pt;&quot;&gt;: &amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;a href=&quot;http://communities.vmware.com/thread/328337&quot; style=&quot;font-family: &#39;Times New Roman&#39;, serif; font-size: 12pt;&quot;&gt;http://communities.vmware.com/thread/328337&lt;/a&gt;3&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;text-indent: 35.4pt;&quot;&gt;
&lt;br /&gt;&lt;/div&gt;
&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/9152650577971095162/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/02/vmware-data-recovery-plugin-error-could.html#comment-form' title='1 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/9152650577971095162'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/9152650577971095162'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/02/vmware-data-recovery-plugin-error-could.html' title='VMWARE Data Recovery Plugin: Error could not connect to the Data Recovery Service on the Appliance'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>1</thr:total></entry><entry><id>tag:blogger.com,1999:blog-1374807488486422555.post-6272688088396564913</id><published>2012-02-22T09:06:00.000-08:00</published><updated>2012-02-22T09:28:08.855-08:00</updated><title type='text'>error mounting  replica LUNS on VMWARE  ESXi5</title><content type='html'>&lt;div dir=&quot;ltr&quot; style=&quot;text-align: left;&quot; trbidi=&quot;on&quot;&gt;
Hi,&lt;br /&gt;
&lt;br /&gt;
a days ago I had some problems trying to test replicas between two EMC arrays connected to different vSphere 5 clusters.&lt;br /&gt;
I openned a request with EMC and they told me replica was fine.&lt;br /&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;color: black;&quot;&gt;
I tried to mount the datastore by using esxcli the next command:    &lt;i&gt;&lt;br /&gt;&lt;/i&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;color: black;&quot;&gt;
&lt;i&gt;esxcli storage vmfs snapshot mount -u &quot;4xxxxxx-99xxx-b555-001xxxxxx8&quot;&lt;/i&gt;&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;color: black;&quot;&gt;
It faulted with error and redirected me to vmkernel.log.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;color: black;&quot;&gt;
I reviewed vmkernel.log and I saw an error “Denying reservation access on an ATS-only vol”, I search for this error (and many others).&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot; style=&quot;color: black;&quot;&gt;
Finally I got this KB article on Vmware. It is not really same case but I tried it on a  nonproduction server and finally VMFS5  datastore could be mounted.&lt;/div&gt;
&lt;div class=&quot;MsoNormal&quot;&gt;
&lt;a href=&quot;http://kb.vmware.com/selfservice/search.do?cmd=displayKC&amp;amp;docType=kc&amp;amp;externalId=2006858&quot;&gt;&lt;span lang=&quot;EN-US&quot;&gt;http://kb.vmware.com/selfservice/search.do?cmd=displayKC&amp;amp;docType=kc&amp;amp;externalId=2006858&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;
&lt;br /&gt;
After disabling these features I finally could mount snapshots of replica, and the replica itself when testing promote.&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://raul-storage-virtualization.blogspot.com/feeds/6272688088396564913/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/02/cant-mount-replica-luns-on-esxi5.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/6272688088396564913'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/1374807488486422555/posts/default/6272688088396564913'/><link rel='alternate' type='text/html' href='http://raul-storage-virtualization.blogspot.com/2012/02/cant-mount-replica-luns-on-esxi5.html' title='error mounting  replica LUNS on VMWARE  ESXi5'/><author><name>Anonymous</name><uri>http://www.blogger.com/profile/02129302443328310732</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='https://img1.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry></feed>