<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electrically4U</title>
	<atom:link href="https://electrically4u.com/feed/" rel="self" type="application/rss+xml" />
	<link>https://electrically4u.com</link>
	<description>To Charge your Brain</description>
	<lastBuildDate>Thu, 06 Aug 2026 15:42:07 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.3</generator>

<image>
	<url>https://electrically4u.com/wp-content/uploads/2019/10/cropped-electrically4u22-copy-32x32.png</url>
	<title>Electrically4U</title>
	<link>https://electrically4u.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">167816574</site>	<item>
		<title>Four point starter &#8211; Construction and Working</title>
		<link>https://electrically4u.com/four-point-starter/</link>
					<comments>https://electrically4u.com/four-point-starter/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Thu, 06 Aug 2026 15:38:04 +0000</pubDate>
				<category><![CDATA[DC Motor]]></category>
		<category><![CDATA[dc motor]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=232086</guid>

					<description><![CDATA[Four point starter is also a protective starting device similar to three point starter, used in DC shunt and compound motors. It safely starts the motor by limiting the high starting current and provides protection against low voltage and overload conditions.

In a three point starter, the no volt release coil is connected in series with the shunt field winding and the field rheostat. Because of this, the same current flows through both the shunt field and the no volt release coil.]]></description>
		
					<wfw:commentRss>https://electrically4u.com/four-point-starter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">232086</post-id>	</item>
		<item>
		<title>Three point starter &#8211; Construction &#038; Working</title>
		<link>https://electrically4u.com/three-point-starter/</link>
					<comments>https://electrically4u.com/three-point-starter/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Sun, 02 Aug 2026 13:48:00 +0000</pubDate>
				<category><![CDATA[DC Motor]]></category>
		<category><![CDATA[dc motor]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=232015</guid>

					<description><![CDATA[A three point starter is a protective starting device used with DC shunt motors and compound motors to limit the high starting current and protect the motor from damage. Since the armature resistance of a DC motor is very low, connecting the motor directly to the power supply at the time of starting will draw a dangerously high current. ]]></description>
		
					<wfw:commentRss>https://electrically4u.com/three-point-starter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">232015</post-id>	</item>
		<item>
		<title>Need for Starter in DC Motor</title>
		<link>https://electrically4u.com/need-for-starter-in-dc-motor/</link>
					<comments>https://electrically4u.com/need-for-starter-in-dc-motor/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Thu, 30 Jul 2026 16:13:40 +0000</pubDate>
				<category><![CDATA[DC Motor]]></category>
		<category><![CDATA[dc motor]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231987</guid>

					<description><![CDATA[A starter is an essential device that is used to protect a DC motor during starting. The need for starter in DC motor arises because the motor draws a very large current when it is switched ON. This excessive starting current can damage the armature winding, commutator, and brushes, and may also cause a voltage drop in the electrical supply system. Therefore, a DC motor starter is used to limit the starting current and ensure smooth, safe, and reliable motor operation.]]></description>
		
					<wfw:commentRss>https://electrically4u.com/need-for-starter-in-dc-motor/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231987</post-id>	</item>
		<item>
		<title>Parallel Operation of DC Generators</title>
		<link>https://electrically4u.com/parallel-operation-of-dc-generators/</link>
					<comments>https://electrically4u.com/parallel-operation-of-dc-generators/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Mon, 27 Jul 2026 13:56:31 +0000</pubDate>
				<category><![CDATA[DC Generator]]></category>
		<category><![CDATA[dc generator]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231915</guid>

					<description><![CDATA[The Parallel Operation of DC Generators is widely used in power stations because it provides a reliable, efficient, and flexible power supply. Instead of installing one large generator to meet the maximum load demand, power plants use several smaller DC generators connected in parallel. These generators can operate individually or together depending on the electrical load. This arrangement improves system reliability, makes maintenance easier, and allows future expansion without replacing the existing system.]]></description>
		
					<wfw:commentRss>https://electrically4u.com/parallel-operation-of-dc-generators/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231915</post-id>	</item>
		<item>
		<title>Equalizer Rings in DC Machines</title>
		<link>https://electrically4u.com/equalizer-rings-in-dc-machines/</link>
					<comments>https://electrically4u.com/equalizer-rings-in-dc-machines/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Sat, 25 Jul 2026 13:36:07 +0000</pubDate>
				<category><![CDATA[DC Generator]]></category>
		<category><![CDATA[dc generator]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231901</guid>

					<description><![CDATA[Equalizer Rings in DC Machine are used in lap wound DC generators and DC motors to maintain equal current distribution among the parallel paths. They reduce brush sparking, improve commutation, and increase the efficiency of the machine. Since unequal pole flux can create different induced voltages in each parallel path, equalizer rings provide an alternative path for circulating current and ensure smooth operation.]]></description>
		
					<wfw:commentRss>https://electrically4u.com/equalizer-rings-in-dc-machines/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231901</post-id>	</item>
		<item>
		<title>Methods of Improving Commutation</title>
		<link>https://electrically4u.com/methods-of-improving-commutation/</link>
					<comments>https://electrically4u.com/methods-of-improving-commutation/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Fri, 24 Jul 2026 14:08:35 +0000</pubDate>
				<category><![CDATA[DC Generator]]></category>
		<category><![CDATA[dc generator]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231858</guid>

					<description><![CDATA[Methods of Improving Commutation are used in DC machines to ensure smooth current reversal in the armature coils without producing...]]></description>
		
					<wfw:commentRss>https://electrically4u.com/methods-of-improving-commutation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231858</post-id>	</item>
		<item>
		<title>Commutation in DC Machine</title>
		<link>https://electrically4u.com/commutation-in-dc-machine/</link>
					<comments>https://electrically4u.com/commutation-in-dc-machine/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Wed, 22 Jul 2026 08:34:11 +0000</pubDate>
				<category><![CDATA[DC Generator]]></category>
		<category><![CDATA[dc generator]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231830</guid>

					<description><![CDATA[Commutation in DC machine is one of the most important processes in electrical machine. It ensures that current flowing in...]]></description>
		
					<wfw:commentRss>https://electrically4u.com/commutation-in-dc-machine/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231830</post-id>	</item>
		<item>
		<title>Direct Memory Access</title>
		<link>https://electrically4u.com/direct-memory-access/</link>
					<comments>https://electrically4u.com/direct-memory-access/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Fri, 07 Nov 2025 05:28:10 +0000</pubDate>
				<category><![CDATA[Basics of Embedded System]]></category>
		<category><![CDATA[embedded system]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231681</guid>

					<description><![CDATA[Direct Memory Access (DMA) is a data transfer technique used in computer systems to move data directly between memory and...]]></description>
		
					<wfw:commentRss>https://electrically4u.com/direct-memory-access/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231681</post-id>	</item>
		<item>
		<title>Star Delta Transformation with solved problems</title>
		<link>https://electrically4u.com/star-delta-transformation/</link>
					<comments>https://electrically4u.com/star-delta-transformation/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Wed, 05 Nov 2025 10:42:35 +0000</pubDate>
				<category><![CDATA[Circuit Basics]]></category>
		<category><![CDATA[Electric circuit]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231643</guid>

					<description><![CDATA[Star delta transformation is a simple and useful technique used for solving complex networks. The three circuit elements, such as...]]></description>
		
					<wfw:commentRss>https://electrically4u.com/star-delta-transformation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231643</post-id>	</item>
		<item>
		<title>Kapp regulation diagram of transformer</title>
		<link>https://electrically4u.com/kapp-regulation-diagram-of-transformer/</link>
					<comments>https://electrically4u.com/kapp-regulation-diagram-of-transformer/#respond</comments>
		
		<dc:creator><![CDATA[Abragam Siyon Sing M]]></dc:creator>
		<pubDate>Sat, 27 Apr 2024 09:26:41 +0000</pubDate>
				<category><![CDATA[Transformer]]></category>
		<category><![CDATA[electrical engineering]]></category>
		<category><![CDATA[electrical machine]]></category>
		<category><![CDATA[transformer]]></category>
		<guid isPermaLink="false">https://electrically4u.com/?p=231348</guid>

					<description><![CDATA[The Kapp regulation diagram is a graphical method of determining the voltage regulation in a transformer. It was proposed by...]]></description>
		
					<wfw:commentRss>https://electrically4u.com/kapp-regulation-diagram-of-transformer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">231348</post-id>	</item>
	</channel>
</rss>
