Radio frequency ID, or RFID, technology can interfere with medical equipment, according to a study published in The Journal of the American Medical Association.

The study by six Dutch scientists has found electromagnetic interference (EMI) generated by the track-and-trace chips has the potential to cause disruption to medical devices, posing a potential hazard to patients.

RFID-tagged wristbands are currently used in some hospitals to ensure the correct procedures are carried out on patients. But the future of healthcare is likely to involve far more RFID-style technology, according to a recent report by Ofcom, which included a prediction that in-body and on-body wireless networks could become the norm for monitoring patients over the next decade.

The Dutch scientists looked at both active (that is, information transmitting) and passive (that is, requiring a reader device) RFID systems and found 34 'incidents' were triggered out of 123 EMI tests. Twenty-two of those incidents were classed as 'hazardous', two as 'significant' and 10 as 'light', according to a critical-care adverse-events scale. The average distance between the RFID reader and the medical device in all the EMI incidents was 30cm.

Passive RFID systems caused more incidents than active signals: 26 incidents in 41 EMI tests (63 percent), compared to eight incidents in 41 EMI tests (20 percent).

A report abstract states: "In a controlled, non-clinical setting, RFID induced potentially hazardous incidents in medical devices. Implementation of RFID in the critical-care environment should require on-site EMI tests and updates of international standards."

The tests took place during May 2006 at the Academic Medical Centre in the University of Amsterdam using an active 125kHz RFID system and passive 868MHz RFID system in the proximity of 41 medical devices in 17 categories with 22 different manufacturers. Three tests were carried out on each piece of medical equipment.

Credit: RFID could disrupt medical devices, say researchers from silicon.com

  • Email
  • Trackback
  • Clip Link
  • Print friendlyPrint with Konica

Did you find this article useful?
0 out of 2 people found this useful


Full Talkback thread

0 comments

Company/Topic Alerts

Create a new alert from the list below:




On The Road Blog

Mobile Operating Systems: MOPS At a Gl...

Mobile Operating Systems: At a Glance Author: Eric Everson, Founder MyMobiSafe Since posting my blog exposing the security Google G1 security issue, I have received a few emails... More

Post a comment

VoxOx Update

In the 10 days since I first wrote about the new VoxOx program, I have continued trying to use it. The news, thus far, is not good. I did finally get past the "boo boo" and get registered.... More

Post a comment

Google Beware: Hackers Set Sights On A...

Google Beware: Hackers Set Sights On Android G1 Handsets Author: Eric Everson, MyMobiSafe.com Could the security concerns surrounding Google’s Open Source Mobile Operating System... More

Post a comment